26<br />
Maintenance <strong>and</strong> Troubleshooting<br />
The following information describes how to service <strong>and</strong> maintain the <strong>MagicStream</strong> ®<br />
<strong>Laminar</strong>.<br />
Filter Cleaning<br />
Perform routine maintenance on the filter to ensure trouble-free <strong>Laminar</strong><br />
operation. Be careful to keep debris out of the discharge plumbing when<br />
cleaning the filter. If debris gets into the filter discharge line to the laminar,<br />
follow this procedure:<br />
1. Remove the laminar by unscrewing the two deck housing lid retaining<br />
screws.<br />
2. Remove the deck housing lid <strong>and</strong> laminar unit <strong>and</strong> place on the deck.<br />
3. Disconnect the supply union <strong>and</strong> turn on the <strong>Laminar</strong> supply pump until the<br />
water runs clear.<br />
4. Reattach the union, place the laminar back in the deck housing <strong>and</strong> check<br />
the alignment of the stream.<br />
5. Replace the deck housing lid retaining screws.<br />
Clogged <strong>Laminar</strong> (Poor Stream Quality)<br />
If the laminar orifice becomes clogged with debris, follow this procedure:<br />
1. Remove the <strong>Laminar</strong> by unscrewing the two deck housing lid retaining<br />
screws.<br />
2. Remove the deck housing lid <strong>and</strong> <strong>Laminar</strong> unit <strong>and</strong> place on the deck.<br />
Disconnect the supply union.<br />
3. Using a garden hose, place the hose over the jet nozzle <strong>and</strong> force water<br />
backward through the unit <strong>and</strong> out the 3/4” open union. This will clear most<br />
of the debris.<br />
NOTE: Do not insert anything into the laminar orifice! This may permanently<br />
damage the laminar stream.<br />
MAGICSTREAM ® <strong>Laminar</strong> <strong>Installation</strong> <strong>and</strong> User’s <strong>Guide</strong>