Chapter 2: NMX Alert Format<br />
where<br />
arg1 = elapsed time since NaqsServer was last started<br />
arg2 = number of packets received in past 24 hours (or since startup)<br />
arg3 = percentage of packets received which were retransmitted packets<br />
arg4 = number of instruments from which packets were received in past 24 hours<br />
arg5 = total number of instruments in NaqsServer configuration<br />
arg6 = list of stations from which packets were received in the past 24 hours<br />
arg7 = list of stations from which NO packets were received in the past 24 hours<br />
2.3.2.4 RbfOpenFail<br />
2.3.2.5 RbfWriteFail<br />
2.3.2.6 RbfWriteOk<br />
This message is issued if one or more ringbuffers cannot be opened properly when<br />
NaqsServer starts up.<br />
sourceID NaqsServer (or configured ID)<br />
classID RbfOpenFail<br />
format string File open failed on %1 / %2 ringbuffers. See Naqs log.<br />
arguments /arg1/arg2<br />
where arg1 = number of ringbuffers which could not be opened<br />
arg2 = number of ringbuffers which NaqsServer attempted to open<br />
This message is issued when there is an error writing to a ringbuffer.<br />
sourceID NaqsServer (or configured ID)<br />
classID RbfWriteFail<br />
format string Ringbuffer write failure on %1, rc = %2, count = %p.<br />
arguments /arg1/arg2<br />
where arg1 = name of channel for which write failed<br />
arg2 = integer error code from program<br />
This message is issued when a ringbuffer write succeeds after previously being failed.<br />
sourceID NaqsServer (or configured ID)<br />
classID RbfWriteOk<br />
format string Ringuffer write succeeded on %1 after %p failures.<br />
arguments /arg1<br />
where arg1 = name of channel<br />
2.3.2.7 InstrumentOffline<br />
This message is issued when Naqs has not received any data for 10 minutes from one<br />
or more instruments that were previously online.<br />
sourceID NaqsServer (or configured ID)<br />
classID InstrumentOffline<br />
format string NaqsServer has stopped receiving from %1%r\<br />
Currently receiving from %2 / %3 instruments %r\<br />
14602R4<br />
<strong>Nanometrics</strong> <strong>Data</strong> <strong>Formats</strong><br />
2003-11-07 <strong>Reference</strong> <strong>Guide</strong><br />