vacon nxl the easy and impressive ac drive
vacon nxl the easy and impressive ac drive
vacon nxl the easy and impressive ac drive
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
first-class usability<br />
The basic settings can be programmed by simply launching <strong>the</strong> V<strong>ac</strong>on NXL start-up wizard.<br />
Only four steps are required, <strong>and</strong> <strong>the</strong> <strong>drive</strong> is ready to run.<br />
START-UP WIZARD<br />
=Push <strong>the</strong> button<br />
START MODE rpm n I n (A)<br />
+<br />
rpm<br />
A<br />
+<br />
+<br />
-<br />
+<br />
+<br />
-<br />
ENTER<br />
reset<br />
-<br />
ENTER<br />
reset<br />
-<br />
ENTER<br />
reset<br />
-<br />
ENTER<br />
reset<br />
1 Push 5 seconds 2 Select <strong>the</strong> 3 Accept<br />
4 Tune 5 Accept<br />
6 Tune Accept<br />
to <strong>ac</strong>tivate (in<br />
mode. See<br />
n(rpm)<br />
7<br />
I(A)<br />
stop mode)<br />
table below!<br />
P2.1.1Min. Freq (Hz)<br />
P2.1..2 Max.Freq (Hz)<br />
P2.1.3 Acc time (s)<br />
P2.1.4 Dec time (s)<br />
P2.1.5 Current limit(A)<br />
P2.1.6 Motor Un (V)<br />
P2.1.7 Motor fn(Hz)<br />
P2.1.11Start funct.<br />
P2.1.12 Stop funct.<br />
P2.1.13 U/f optimization<br />
P2.1.14 I/0 ref<br />
P2.1.21 Auto restart<br />
P3.1 Control pl<strong>ac</strong>e<br />
M<br />
St<strong>and</strong>ard<br />
Fan<br />
Pump<br />
0<br />
Hz<br />
20<br />
Hz<br />
20<br />
Hz<br />
0<br />
Hz<br />
High<br />
performance<br />
50<br />
Hz<br />
50<br />
Hz<br />
50<br />
Hz<br />
50<br />
Hz<br />
3<br />
s<br />
20<br />
s<br />
5<br />
s<br />
1<br />
s<br />
3<br />
s<br />
20<br />
s<br />
5<br />
s<br />
1<br />
s<br />
I *1,5 400<br />
H<br />
V<br />
I *1,1 400<br />
L<br />
V<br />
I *1,1 400<br />
L<br />
V<br />
I *1,8 400<br />
H<br />
V<br />
50<br />
Hz<br />
50<br />
Hz<br />
50<br />
Hz<br />
50<br />
Hz<br />
0= 0=<br />
Ramp Coasting<br />
0= 0=<br />
Ramp Coasting<br />
0=<br />
Ramp<br />
1=<br />
Ramp<br />
0= 0=<br />
Ramp Coasting<br />
0=<br />
Not<br />
used<br />
0=<br />
Not<br />
used<br />
0=<br />
Not<br />
used<br />
1=<br />
automatic<br />
torque<br />
boost<br />
0=<br />
Ai1<br />
0-10V<br />
0=<br />
Ai1<br />
0-10V<br />
0=<br />
Ai1<br />
0-10V<br />
0=<br />
Ai1<br />
0-10V<br />
0=<br />
Not<br />
used<br />
0=<br />
Not<br />
used<br />
0=<br />
Not<br />
used<br />
0=<br />
Not<br />
used<br />
I/O<br />
I/O<br />
I/O<br />
I/O<br />
For example: These settings are made automatically<br />
if <strong>the</strong> fan mode is selected.<br />
The instructions to install, connect <strong>and</strong> program <strong>the</strong> V<strong>ac</strong>on<br />
NXL are included in <strong>the</strong> credit-card size Quick Guide att<strong>ac</strong>hed<br />
to e<strong>ac</strong>h unit.<br />