<strong>40</strong> <strong>Series</strong> <strong>Ball</strong> <strong>Valves</strong> 7<br />

Pneumatic Actuators<br />

Swagelok rack and pinion pneumatic<br />

actuators are compact, lightweight, easily<br />

mountable, and can be operated with<br />

standard shop air. For technical data,<br />

including pressure-temperature ratings<br />

and materials of construction, see the<br />

Rack and Pinion Pneumatic Actuators for<br />

Swagelok <strong>Ball</strong> <strong>Valves</strong> catalog, <strong>MS</strong>-06-87.<br />

1/8 in.<br />

NPT<br />

➀ S = spring return<br />

D = double acting<br />

4 mounting<br />

holes 0.34<br />

(8.6) dia<br />

O (S)➀<br />

N (D)➀<br />

B<br />

M<br />

K L D<br />

C<br />

A<br />

Q<br />

G<br />

J<br />

E<br />

F<br />

H<br />

1/8 in.<br />

NPT<br />

Dimensions<br />

Valve <strong>Series</strong><br />

41, 41-A, 41X,<br />

42, 42-A, 42X<br />

43, 43-A,<br />

43X, 43Y<br />

43, 43-A,<br />

43X, 43Y<br />

44, 44-A, 44X<br />

45, 45-A,<br />

45X, 45Y<br />

Actuator<br />

Model<br />

-131<br />

-151<br />

-133<br />

-153<br />

Dimensions, in. (mm)<br />

A B C D E F G H J K L M N O Q<br />

2.81<br />

(71.4)<br />

2.91<br />

(73.9)<br />

0.34<br />

(8.6)<br />

3.72<br />

(94.5)<br />

4.13<br />

(104) 0.48<br />

4.25<br />

(108)<br />

2.00<br />

(50.8)<br />

1.75<br />

(44.5)<br />

3.04<br />

(77.2)<br />

1.73<br />

(43.9)<br />

1.31<br />

(33.3)<br />

0.<strong>60</strong><br />

(15.2)<br />

0.52<br />

(13.2)<br />

0.31<br />

(7.9)<br />

1.46<br />

(37.1)<br />

1.25<br />

(31.8)<br />

4.09<br />

(104)<br />

4.91<br />

(125)<br />

1.80<br />

(45.7)<br />

2.30<br />

(58.4)<br />

2.00<br />

(50.8)<br />

2.31<br />

(58.7)<br />

4.07<br />

(103)<br />

2.32<br />

(58.9)<br />

1.75<br />

(44.5)<br />

0.75<br />

(19.1)<br />

0.81<br />

(20.6)<br />

0.44<br />

(11.2)<br />

2.16<br />

(54.9)<br />

1.56<br />

(39.6)<br />

5.89<br />

(150)<br />

7.86<br />

(200) 2.56<br />

(12.2) 2.19<br />

(65.0)<br />

(55.6)<br />

Actuator Pressure at Maximum System Pressure<br />

Required pressures based on valve performance using<br />

pressurized air or nitrogen.<br />

Actuator<br />

Model<br />

-131<br />

(90°)<br />

-151<br />

(180°)<br />

-133<br />

(90°)<br />

-153<br />

(180°)<br />

Actuator<br />

Designator<br />

-31<br />

-51<br />

-33<br />

-53<br />

Actuation Modes<br />

Double Acting Spring Return<br />

Valve<br />

Single Dual Single Dual<br />

<strong>Series</strong> Minimum Actuator Pressure, psig (bar)<br />

41, 41-A,<br />

42, 42-A<br />

20 (1.4) 35 (2.5) <strong>60</strong> (4.2) 70 (4.9)<br />

43, 43-A, 43Y 50 (3.5) 80 (5.6) 80 (5.6) —<br />

41X, 42X 20 (1.4) 35 (2.5) <strong>60</strong> (4.2) 70 (4.9)<br />

43X 50 (3.5) 80 (5.6) 70 (4.9) —<br />

43, 43-A, 43Y 20 (1.4) 35 (2.5) 65 (4.5) 75 (5.2)<br />

44, 44-A 25 (1.8) 50 (3.5) 70 (4.9) 90 (6.3)<br />

45, 45-A, 45Y <strong>60</strong> (4.2) 100 (6.9) 90 (6.3) —<br />

43X 20 (1.4) 35 (2.5) 65 (4.5) 70 (4.9)<br />

44X 25 (1.8) 50 (3.5) 70 (4.9) 80 (5.6)<br />

45X <strong>60</strong> (4.2) 100 (6.9) 85 (5.9) —<br />

Other Actuator Options<br />

For Field Assembly or Factory Assembly<br />

■ Electric Actuators<br />

For information, see the Swagelok Electric Actuators—141<br />

and 142 <strong>Series</strong> catalog, <strong>MS</strong>-<strong>01</strong>-35.<br />

■ Solenoid <strong>Valves</strong><br />

For information, see the Swagelok Solenoid <strong>Valves</strong> for<br />

Electropneumatically Actuated <strong>Ball</strong> <strong>Valves</strong> catalog, <strong>MS</strong>-02-41.<br />

■ Limit Switches<br />

indicate actuator position by means of an electrical signal. They<br />

meet a variety of NEMA ratings such as NEMA 4 (weatherproof)<br />

and NEMA 7 (explosion proof). For more information, see the<br />

Swagelok Limit Switches catalog, <strong>MS</strong>-06-39.<br />

■ Position Indicators<br />

provide visual status of a valve.<br />

■ ISO 5211-Compliant Actuator Mounting Bracket Kits<br />

For information, see the Swagelok Actuated <strong>Ball</strong> Valve<br />

Selection Guide, <strong>MS</strong>-02-136.<br />

Ordering Information<br />

Factory-Assembled Actuators<br />

Typical Ordering Number<br />

S S - 4 3 S 4 - 3 1 D<br />

Valve Ordering Number<br />

For dual-mounted assemblies<br />

(two valves mounted to one<br />

actuator), add DM to the<br />

ordering number.<br />

Example: SS-43S4-31DDM<br />

Actuators for Field Assembly<br />

Typical Ordering Number<br />

M S - 1 3 1 - D A<br />

Actuator Model<br />

Determine valve series,<br />

then select actuator model<br />

(see Actuator Pressure table).<br />

Mounting Bracket Kits<br />

Valve <strong>Series</strong> Actuator Model<br />

41, 41-A,<br />

42, 42-A<br />

-131<br />

41X, 42X -151<br />

43, 43-A -131<br />

43X -151<br />

43, 43-A -133<br />

43X -153<br />

43Y<br />

44, 44-A<br />

Actuator Designator<br />

Determine valve series,<br />

then select actuator<br />

model (see Actuator<br />

Pressure table).<br />

Ordering Number<br />

<strong>MS</strong>-MB-41 ➀<br />

<strong>MS</strong>-MB-43<br />

<strong>MS</strong>-MB-43-133<br />

-131 <strong>MS</strong>-MB-43Y<br />

-133<br />

44X -153<br />

45, 45-A -133<br />

45X -153<br />

<strong>MS</strong>-MB-43Y-133<br />

<strong>MS</strong>-MB-44 ➁<br />

<strong>MS</strong>-MB-45<br />

45Y -133 <strong>MS</strong>-MB-45Y<br />

Actuation Mode<br />

D = double acting<br />

C = spring return,<br />

normally closed<br />

O = spring return,<br />

normally open<br />

S = spring return,<br />

3- and 4-way valves<br />

Actuation Mode<br />

DA = double acting<br />

SR = spring return<br />

➀ 42 series valves with<br />

VCO or VCR end<br />

connections mounted to<br />

an actuator are only<br />

available factory<br />

assembled.<br />

➁ 44 series valves with<br />

VCR end connections<br />

require kit<br />

<strong>MS</strong>-MB-44-VCR.