Directional Filter Combiner<br />

87.5 ... 108 MHz, 10 kW<br />

General<br />

The directional filter combiners enable several transmitters<br />

to be connected to one common output.<br />

The design offers an exp<strong>and</strong>able system which is<br />

constructed in a modular <strong>for</strong>m. The configuration<br />

provides the best frequency response <strong>and</strong> optimum<br />

isolation between the inputs.<br />

Design <strong>and</strong> Construction<br />

This combiner consists of two temperature stabilised<br />

3-pole b<strong>and</strong>-pass filters, two 3-dB couplers <strong>and</strong> a<br />

balancing load.<br />

One input is narrowb<strong>and</strong> (NB) in accordance with the<br />

frequency response of the b<strong>and</strong>-pass filters. The<br />

second input is broadb<strong>and</strong> (BB) within the operating<br />

frequency range of the 3-dB coupler.<br />

The directional filter combiner may be extended by<br />

adding further combiners – directional filter combiners<br />

as well as starpoint combiners.<br />

Any heat produced is dissipated into the surroundings<br />

via heat sinks. Thus the combiner is maintenance free<br />

<strong>and</strong> especially safe to operate.<br />

The b<strong>and</strong>-pass filters must be tuned to the operating<br />

channel. Tuning may be done at our factory or can be<br />

carried out on site.<br />

Clear tuning instructions <strong>and</strong> also any special tools<br />

necessary are supplied along with the combiner.<br />

728 393 <strong>FM</strong> Directional filter combiner, 10 kW<br />

Technical Data<br />

Type No. 728 393<br />

Output<br />

Inputs Narrowb<strong>and</strong> input (NB) Broadb<strong>and</strong> input (BB)<br />

Frequency range 87.5 ... 108 MHz 87.5 ... 108 MHz<br />

tuned to one channel free choice of channel<br />

Insertion loss (1 < 0.3 ... 0.4 dB < 0.15 dB<br />

Input power 10 kW 50 kW<br />

Channel spacing<br />

> 0.8 MHz<br />

Isolation<br />

> 35 dB (NB to BB-input)<br />

> 55 dB (BB to NB-input)<br />

VSWR<br />

< 1.1 (at pass b<strong>and</strong>)<br />

< 1.25 (at stop b<strong>and</strong>)<br />

Impedance<br />

50 Ω<br />

Temperature range –20 °C ... +50 °C<br />

Connectors<br />

1 5/8″ EIA-flange (NB-input)<br />

3 1/8″ EIA-flange (BB-input <strong>and</strong> Output)<br />

Colour<br />

RAL 7032 (grey)<br />

Weight<br />

290 kg<br />

Dimensions (l x w x h)<br />

1150 mm x 695 mm x 1435 mm<br />

Packing size (l x w x h)<br />

1350 mm x 870 mm x 1620 mm<br />

CH 1<br />

Narrowb<strong>and</strong> input<br />

(NB)<br />

Load<br />

~<br />

~<br />

CH 2<br />

Broadb<strong>and</strong> input<br />

(BB)<br />

(1 Insertion loss <strong>and</strong> isolation values refer to the min. channel spacing of 0.8 MHz.<br />