Becker & Hickl GmbH
Becker & Hickl GmbH
Becker & Hickl GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Becker</strong> & <strong>Hickl</strong> <strong>GmbH</strong><br />
Technology Leader in Photon Counting<br />
2013
About bh<br />
Technology Leader in Photon Counting<br />
Founded in 1993, <strong>Becker</strong> & <strong>Hickl</strong> have introduced a proprietary time-correlated single-photon counting principle that made TCSPC more<br />
than 100 times faster than the existing devices. Moreover, bh introduced a multi-dimensional TCSPC process that records the photons not<br />
only versus the time in the signal period, but also versus other parameters, such as experiment time, wavelength, or spatial coordinates. The<br />
bh devices are designed to record multi-dimensional photon distributions, time-resolved images, sequences of photon distributions, or multidimensional<br />
time-tag data. The bh TCSPC products are complemented by bh picosecond diode lasers, detector modules, multi-spectral<br />
detector assemblies, and experiment control modules. Based on these components <strong>Becker</strong> & <strong>Hickl</strong> supply their own confocal fluorescence<br />
lifetime laser scanning microscope and FLIM upgrade kits for laser scanning microscopes of various manufacturers. Moreover, bh is supplier<br />
of TCSPC modules for commercial time-domain optical tomography instruments. bh market activities include currently 5 workshops around<br />
the world yearly and the distribution of more than 1200 pages of TCSPC literature.<br />
1993 Introduction of multidimensional TCSPC. Introduction of fast TAC/ADC conversion. TCSPC becomes 100 times faster than it was before. SPC-<br />
300 modules with 32 or 128 simultaneously recording detector channels. Time channel width 820 fs. Saturated count rate 3 MHz.<br />
1994 SPC-330 modules. Improved IRF width.<br />
Routers for parallel operation of detectors.<br />
1995 SPC-430 modules. Continuous Flow mode for infinite sequential recording. Saturated count rate 8 MHz. First single-molecule applications.<br />
Resolution of bursts, lifetime analysis within bursts.<br />
1996 SPC-432 modules. Introduction of Time-Tag recording for single molecule spectroscopy.<br />
First version of PML-16 sixteen channel PMT module<br />
1996 SPC-535 modules. First implementation of TCSPC FLIM. First FLIM applications.<br />
PMS-300 gated photon counter and multichannel scaler<br />
1997 SPC-630 modules. Introduction of PCI bus. Modules contain time-tag mode, standard photon distribution modes, and continuous flow mode.<br />
PMH-100 detector module simplifies system setup.<br />
1998 SPC-730 modules. Introduction of TCSPC FLIM. Scan Sync In and Scan Sync out mode. First applications in FLIM microscopy.<br />
MSA-300 multichannel scaler. 100 MHz count rate, 5 ns channel width.<br />
1999 SPC-134 four-channel packages for optical tomography. Devices contain continuous flow mode, standard photon distribution modes, and time-tag<br />
mode. Saturated sustained count rate 32 MHz.<br />
SPC-130 TCSPC board for industrial applications.<br />
2000 FLIM upgrade kits for Zeiss LSM 510 NLO microscopes.<br />
SPCImage FLIM data analysis software.<br />
MSA-1000 multichannel scaler. 1 ns resolution, count rate 1000 MHz.<br />
BHL-600 red and NIR picosecond diode lasers.<br />
New SPCM software introduces autosave, auto-accumulate, and automatic page stepping functions<br />
2001 SPC-830 modules. Fast DMA bus interface. Saturated sustained count rate 8 MHz. Standard photon distribution modes, FLIM modes, time-tag<br />
recording. For the first time, FLIM and single-molecule techniques were combined in one instrument.<br />
DCC-100 detector controller solves the problem of detector overload.<br />
PMC-100 cooled detector modules. Internal preamplifier, internal high-voltage generator, overload shutdown. System setup is greatly simplified.<br />
Detector-Shutter modules for non-descanned ports of multiphoton microscopes.<br />
2002 FLIM systems for Leica, Olympus, and Biorad laser scanning microscopes.<br />
First multi-spectral FLIM<br />
BHLP-700 NIR picosecond diode lasers. Up to 10 mW at 785 nm.<br />
BDL-405 UV picosecond diode lasers.<br />
DDG-100 pulse generator for multiplexed operation of lasers and SPC modules.<br />
First demonstration of double-exponential FRET imaging.<br />
2003 SPC-144 four-channel TCSPC Imaging Package. Saturated sustained count rate 40 MHz.<br />
BDL-375, 440, and 473 picosecond diode lasers<br />
PML-16 multi-wavelength detector<br />
Online FCS, PCH, and MCS trace calculation in the time-tag mode of the bh TCSPC modules<br />
2004 Simple-Tau 140 and Simple-Tau 830 compact TCSPC systems.<br />
MW-FLIM, first multi-spectral NDD FLIM systems for multiphoton microscopes.<br />
Macro-time synchronisation of several TCSPC modules. First full correlation down to the picosecond region.<br />
2005 New PML-16 sixteen channel detector. Internal high-voltage generator, overload shutdown, control via DCC-100.<br />
High-efficiency single-mode fibre coupling of BDL picosecond diode lasers<br />
FLIM upgrade kits for confocal laser scanning microscopes based on bh BDL-SM lasers and bh TCSPC technology.<br />
W. <strong>Becker</strong>, Advanced Time-Correlated Single Photon Counting Techniques published by Springer.<br />
First edition of BH TCSPC Handbook. 360 pages, 364 references.<br />
2006 High-power CW mode for BDL-SMC picosecond diode lasers.<br />
Second edition of bh TCSPC Handbook. 387 pages, 387 references.<br />
2007 DCS-120 confocal laser scanning systems. Complete fluorescence-lifetime laser scanning microscopes.<br />
DPC-230 16 channel photon correlator, 160 ps resolution.<br />
SPC-154 package and SPC-150 modules. Standard photon distribution modes, continuous flow mode, TCSPC imaging, continuous-flow imaging,<br />
imaging in the time-tag mode. Imaging in time-tag mode for SPC-140 and SPC-830.<br />
2008 FLIM systems for Zeiss LSM 710 microscopes. NDD FLIM systems for Leica SP2 MP and SP5 MP microscopes. Simple-Tau 152 and -154 two<br />
and four channel TCSPC systems. 3rd edition of bh TCSPC Handbook.<br />
2009 GaAsP hybrid detectors. 8-channel parallel TCSPC and TCSPC FLIM systems<br />
2010 Eight-channel SPAD detector. GaAsP hybrid detectors in all bh FLIM systems. Z stack FLIM. 4th edition of bh TCSPC Handbook<br />
2011 Phosphorescence Lifetime imaging (PLIM) in DCS-120 and Zeiss LSM 710 FLIM systems. Fluorescence Lifetime-Transient Scanning (FLITS)<br />
DCS-120 Wideband, DCS-120 Multiphoton, and DCS-120 Macro FLIM systems<br />
2012 DCS-120 electronic alignment, NIR FLIM, FLITS integrated in DCS-120 and LSM 710 FLIM systems, 5th edition of bh TCSPC Handbook<br />
2 bh catalog 2012
Modular TCSPC systems<br />
1500 TCSPC Systems Worldwide<br />
SPC-630 TCSPC module<br />
Multi-dimensional photon distribution mode<br />
Photon stream (parameter tag) mode; buffer size 256 k photons<br />
Multi-detector / multi-wavelength operation<br />
FCS in combination with fluorescence lifetime<br />
Burst-integrated fluorescence lifetime detection<br />
Fast unlimited sequential recording<br />
Fast multiplexing of excitation sources<br />
Total recordable count rate 4 MHz, saturated count rate 8 MHz<br />
Time channel width 813 fs<br />
Each channel expandable for up to 8 detectors<br />
16-channel multi-wavelength detection with PML-SPEC assembly<br />
SPC-830 TCSPC module<br />
Multi-dimensional photon distribution mode<br />
Photon stream (parameter tag) mode; buffer size 8 M photons<br />
Multi-detector / multi-wavelength operation<br />
Triggered MCS (phosphorescence) mode<br />
Synchronisation of channels for photon correlation<br />
Fast scanning: single- and multi-wavelength FLIM module for laser scanning<br />
microscopes<br />
FCS in combination with fluorescence lifetime<br />
Burst-integrated fluorescence lifetime detection<br />
Fast sequential recording<br />
Fast multiplexing of excitation sources<br />
Total recordable count rate 4 MHz, saturated count rate 8 MHz<br />
Time channel width 813 fs<br />
Expandable with up to 8 detectors or 16-channel multispectral detection<br />
16-channel multi-wavelength detection with PML-SPEC assembly<br />
SPC-134 Four-Channel TCSPC package<br />
Four fully parallel TCSPC channels<br />
Multi-dimensional photon distribution mode<br />
Photon stream (parameter tag) mode; buffer size 8 M photons<br />
Multi-detector / multi-wavelength operation<br />
Synchronisation of channels for photon correlation<br />
FCS in combination with fluorescence lifetime<br />
Burst-integrated fluorescence lifetime detection<br />
Unlimited fast sequential recording: TCSPC module for DOT systems<br />
Fast multiplexing of excitation sources<br />
Total recordable count rate 20 MHz<br />
Each channel expandable for up to 8 detectors<br />
SPC-154 Four-Channel TCSPC package<br />
Four fully parallel TCSPC channels<br />
Multi-dimensional photon distribution mode<br />
Multi-detector / multi-wavelength operation<br />
Photon stream (parameter tag) mode; buffer size 2 M photons<br />
Triggered MCS (phosphorescence) mode<br />
Synchronisation of channels for photon correlation<br />
Fast scanning: High-speed FLIM module for laser scanning microscopes<br />
FCS in combination with fluorescence lifetime<br />
Burst-integrated fluorescence lifetime detection<br />
Unlimited fast sequential recording: TCSPC module for DOT systems<br />
Fast multiplexing of excitation sources<br />
Total recordable count rate 20 MHz, saturated count rate 40 MHz<br />
Each channel expandable for up to 8 detectors<br />
SPC-130 low cost TCSPC Modules<br />
Standard fluorescence lifetime, TCSPC FLIM, Diffuse optical tomography, Singlemolecule<br />
spectroscopy<br />
Rugged design<br />
Overvoltage-protected inputs<br />
Photon distribution, time-tag, sequential-recording modes<br />
Low price, especially at large order volumes<br />
SPC-130-EM TCSPC Modules<br />
Improved SPC-130 with fast bus interface and larger memory<br />
Standard fluorescence lifetime, TCSPC FLIM, Diffuse optical tomography, Singlemolecule<br />
spectroscopy<br />
Rugged design<br />
Photon distribution, time-tag, sequential-recording modes<br />
Also available as SPC-134 EM 4-module package<br />
SPC-150: High-end performance at reasonable cost<br />
Multi-dimensional photon distribution mode<br />
Photon stream (parameter tag) mode; buffer size 2 M photons<br />
Multi-detector / multi-wavelength operation<br />
Triggered MCS (phosphorescence) mode<br />
High-speed FLIM module for laser scanning microscopes<br />
FCS in combination with fluorescence lifetime<br />
Burst-integrated fluorescence lifetime detection<br />
Unlimited fast sequential recording: TCSPC module for DOT systems<br />
Fast multiplexing of excitation sources<br />
Recordable count rate 5 MHz, saturated count rate 10 MHz<br />
Expandable with up to 8 detectors or 16-channel multispectral detection<br />
bh catalog 2013 3
Technology Leader in Photon Counting<br />
Simple-Tau Compact TCSPC and TCSPC FLIM Systems<br />
Simple-Tau 830 compact TCSPC systems<br />
Recording by one SPC-830 TCSPC module<br />
Detector control via DCC-100 detector controller card<br />
Compact FLIM systems for laser scanning microscopy<br />
General time-resolved fluorescence spectroscopy<br />
Single-molecule spectroscopy<br />
Combined FCS and fluorescence lifetime systems<br />
Burst-integrated fluorescence lifetime experiments<br />
Compatible with bh multispectral FLIM detectors<br />
Simple-Tau 150 compact TCSPC systems<br />
One SPC-150 TCSPC channel<br />
One DCC-100 detector controller<br />
Portable DOT systems<br />
High-Speed FLIM systems<br />
Compatible with bh multispectral FLIM detectors<br />
Part of bh DCS-120 confocal scanning FLIM systems<br />
Part of bh FLIM systems for Zeiss LSM 510 and LSM 710 family<br />
Part of bh NDD FLIM systems for Leica SP2 and SP5 MP<br />
Simple-Tau 152 compact TCSPC systems<br />
Two parallel SPC-150 TCSPC channels<br />
One DCC-100 detector controller<br />
Portable DOT systems<br />
High-Speed FLIM systems<br />
Part of bh DCS-120 confocal scanning FLIM systems<br />
Part of bh FLIM systems for Zeiss LSM 510 and LSM 710 family<br />
Simple-Tau 154 compact TCSPC systems<br />
Four parallel SPC-150 TCSPC channels<br />
Portable DOT systems<br />
Ultra-High-Speed parallel multispectral FLIM systems<br />
Simple-Tau 130 compact TCSPC systems<br />
Simple-Tau 130 EM compact TCSPC systems<br />
One SPC-130 or SPC-130 EM TCSPC channel<br />
One DCC-100 detector controller<br />
Standard fluorescence lifetime applications<br />
Anti-bunching measurements<br />
Multi-Tau 8-Channel TCSPC systems<br />
Eight SPC-150 or SPC-130 TCSPC modules controlled from a standard Pentium PC<br />
Portable DOT systems<br />
Ultra-High-Speed FLIM systems<br />
Picosecond Photon Correlators<br />
DPC-230 16 Channel Picosecond Photon Correlator<br />
Recording of absolute photon times in 16 channels<br />
Fluorescence correlation down to ps times<br />
FCS combined with fluorescence decay<br />
3-channel reversed-start-stop TCSPC mode for PMT inputs<br />
15-channel reversed start-stop mode for LVTTL SPAD inputs<br />
15-channel multiscaler mode<br />
TCSPC FLIM Mode<br />
Multiscaler FLIM mode<br />
Autocorrelation / Cross correlation within 16 LVTTL or 4 CFD channels<br />
Simple-Tau DPC System<br />
Lap-top based compact system<br />
DPC-230 16 Channel Picosecond Photon Correlator<br />
Optional:<br />
DCC-100 detector controller card<br />
GVD-120 scan controller card<br />
4 bh catalog 2013
Multichannel Scalers<br />
1500 TCSPC Systems Worldwide<br />
MSA-300 Multichannel Scaler<br />
Recording of luminescence decay functions in the ns, and µs range<br />
Time-of-flight mass spectroscopy<br />
Lidar<br />
Time resolution 5 ns per time channel<br />
Maximum count rate 100 MHz<br />
Compact Simple-Tau MSA systems available<br />
PMS-400 Gated Photon Counter and Multichannel Scaler<br />
Dated detection of optical signals<br />
Luminescence decay in the µs and ms range<br />
Chemoluminescence<br />
Two parallel recording channels<br />
Gating down to 1 ns<br />
Multiscaler operation down to 300 ns per channel<br />
Simple-Tau MSA systems<br />
Lap-top based compact MSA-1000 or MSA-300 systems<br />
1,2, or 3 MSA-1000 modules<br />
1,2, 0r 3 MSA-300 modules<br />
DCC-100 detector controller<br />
Recording of luminescence decay functions in the ns, and µs range<br />
Time-of-flight mass spectroscopy<br />
Lidar<br />
Detectors and Detector Assemblies<br />
100<br />
mA/W<br />
-20<br />
-6 -1<br />
10<br />
-4<br />
-0<br />
-3<br />
1<br />
0.1<br />
PMC-100<br />
Cathode Radiant Sensitivity<br />
0.01<br />
200 300 400 500 600 700 800 900nm<br />
PMC-100 cooled PMT modules<br />
Cathode versions for UV to NIR region<br />
Internal PMT voltage generation<br />
IRF width 150 ps<br />
Ultra-stable IRF up to recorded count rates of 5 MHz<br />
Internal preamplifier<br />
Overload shutdown<br />
Power supply and control via DCC-100 detector controller<br />
Adapters for Zeiss LSM NDD ports, Zeiss LSM confocal ports, Leica SP2 and SP5<br />
RLD Ports, bh DCS-120 confocal FLIM system<br />
Part of the bh modular FLIM and modular DOT systems<br />
PMZ-100 PMT modules for FLIM Systems of Zeiss LSM 710<br />
Microscopes<br />
Adapter for Confocal (DC) port<br />
Adapter for non-descanned detection (NDD) port<br />
Internal PMT voltage generation<br />
IRF width 150 ps<br />
Ultra-stable IRF up to recorded count rates of 5 MHz<br />
Internal preamplifier<br />
Overload shutdown<br />
Power supply and control via DCC-100 detector controller<br />
PML-16 C 16-Channel TCSPC detectors<br />
16-channel PMT with routing electronics and internal HV power supply<br />
Simultaneous detection in 16 channels<br />
Connects directly to all bh SPC modules<br />
Power supply and control via DCC-100 detector controller<br />
IRF width 150 to 200 ps<br />
Part of bh multispectral TCSPC FLIM detectors<br />
HPM-100 hybrid detector modules<br />
GaAsP versions: 40% detection efficiency throughout visible spectrum<br />
GaAs versions: 15% detection efficiency up to 850 nm<br />
No afterpulsing<br />
GaAsP versions: 130 ps IRF width<br />
Multialkali versions: 50 ps IRF width<br />
Internal high-voltage generator, controlled via bh DCC-100<br />
Active area 3 mm diameter<br />
C-Mount adapter<br />
Adapter to bh DCS-120 confocal scanning FLIM system<br />
Adapter to NDD port of Zeiss LSM 510 and LSM 710 NLO microscopes<br />
Adapter to RLD port of Leica SP2 MP and SP5 MP microscopes<br />
bh catalog 2013 5
Technology Leader in Photon Counting<br />
Single-photon avalanche photodiode modules (SPADs)<br />
id Quantique id-100-20 and -50 SPADs<br />
Direct-coupled and fibre-coupled versions<br />
Ultra-high efficiency in visible region<br />
IRF width 40 ps<br />
Active areas of 20µm, 50µm<br />
Stable IRF over count rate<br />
Dark count rates
Detector Electronics<br />
1500 TCSPC Systems Worldwide<br />
DCC-100 detector controller<br />
Power supply for two detectors<br />
Power supply of thermoelectric coolers<br />
Gain control and overload shutdown<br />
Control of shutters or other actuators<br />
Control of bh detector / shutter assemblies<br />
Power control of bh BHLP and BDL lasers<br />
Part of the bh modular FLIM, modular DOT, and Simple-Tau systems<br />
HVM-3000 High-Voltage module for PMTs and MCP-PMTs<br />
Small size, attaches directly to PMT or MCP<br />
SHV connector, connects directly to Hamamatsu R3809U MCP PMTs<br />
+12 V power supply via bh DCC-100 detector controller<br />
Output voltage -400 to -3000 V, controlled via DCC-100 detector controller<br />
HRT-41 four-channel router<br />
Connects up to four PMC-100, H7422 or R3809U detectors to one TCSPC channel<br />
All detectors are detecting simultaneously<br />
HRT-81 eight-channel router<br />
Connects up to eight PMC-100, H7422 or R3809U detectors to one TCSPC channel<br />
All detectors are detecting simultaneously<br />
HRT-82 eight-channel router<br />
Connects up to eight SPAD modules to one TCSPC channel<br />
All detectors are detecting simultaneously<br />
HFAC-26 Preamplifiers<br />
For R3809U MCP PMT, H7422 modules, and other PMTs<br />
Power supply from SPC or DCC module<br />
Overload shutdown in conjunction with DCC-100 controller<br />
Overload thresholds 0.1µA, 0,3µA, 1µA, 2µA, 3µA, 10µA<br />
HFAH-26 Preamplifiers<br />
Low-noise<br />
For R3809U MCP PMT, H7422 modules, and other PMTs<br />
Power supply from SPC or DCC module<br />
Overload shutdown in conjunction with DCC-100 controller<br />
PHD-400 PIN Photodiode modules<br />
For synchronisation of TCSPC experiments with lasers<br />
Power supply from SPC or DCC module<br />
Detector area 0.25 mm 2<br />
Current indicator for easy alignment<br />
Experiment Control<br />
DDG-200 Digital Delay Generator<br />
Multiplexing of lasers and routing into TCSPC Modules<br />
Multiplexing rate up to 100 kHz<br />
Non-overlapping multiplexing<br />
On-times programmable individually<br />
Part of the bh modular DOT systems<br />
Part of bh FLIM / PLIM system for Zeiss LSM 710 NLO<br />
Integrated in bh SPCM TCSPC instrument control software<br />
GVD-120 Scan Controller Card<br />
Generation of scan signals for galvanometer mirrors and piezo stages<br />
Controls also two bh BDL-SMC ps diode lasers<br />
Dual-axis control<br />
Frame scan, line scan, point operation<br />
Cycloid flyback<br />
Extremely high scan rates<br />
Laser beam blanking<br />
Fully digital signal generation<br />
Independent of software response times<br />
Pixel times down to 0.5 µs<br />
Pixel numbers up to 2048x2048<br />
Scan area definition interacts with images of SPCM software<br />
Part of bh DCS-120 confocal scanning systems<br />
Fully Integrated into SPCM software of bh TCSPC modules<br />
bh catalog 2013 7
Technology Leader in Photon Counting<br />
Picosecond Diode Lasers<br />
New! BDS-SM series picosecond diode lasers<br />
Small-size OEM Module<br />
Dimensions 40 mm x 40 mm x 110 mm<br />
405 nm, 440 nm, 473 nm, 488 nm, 510 nm, 640 nm, 685nm, 785nm<br />
Free-beam or single-mode fibre output<br />
Pulse width down to 52 ps<br />
Pulse repetition rate 50 MHz<br />
CW equivalent power 0.25 to 1.2 mW<br />
Fast on / off / multiplexing capability<br />
All electronics integrated<br />
No external driver unit<br />
Simple +12 V power supply<br />
BDL-SMC Series Picosecond / CW diode lasers<br />
375 nm, 405 nm, 440 nm, 473 nm, 488 nm, 510 nm, 640 nm, 685nm, 785nm<br />
Beam corrector removes astigmatism and makes beam circular<br />
Interfaces with commonly used fibre couplers<br />
Repetition rate 20, 40, 80 MHz<br />
High-Power CW mode<br />
Pulse width typically 40 to 80 ps<br />
Fast on/off/multiplexing capability<br />
Fast electronic power control<br />
405 nm: 1 mW from single-mode fibre<br />
440, 473, 488, 640 nm: 0.4 mW from single-mode fibre<br />
Part of the bh modular FLIM systems for laser scanning microscopes<br />
The BDL-SMC lasers were designed in cooperation with Lasos <strong>GmbH</strong>, Jena<br />
Single-Mode Fibre Coupling<br />
Point-Source fibre coupler and fibre<br />
up to 70% coupling efficiency<br />
Fibres with FC output or with collimated output<br />
Part of DCS-120 Confocal Scanning FLIM Systems<br />
Easy Power supply and Control<br />
Power supply from simple wall mounted +12V power supply or from DCS box<br />
All laser electronics integrated laser head<br />
Interfaces directly with GVD-100 scan controller<br />
BDL-405-SMCP, BDL-440-SMCP, BDL-473-SMCP, BDL-488-<br />
SMCP picosecond diode lasers with fibre pigtails<br />
Single-mode fibre pigtail<br />
Single-mode fibre permanently attached to laser<br />
No fibre alignment required<br />
405 nm, 440 nm, 473 nm, 488 nm, 640 nm<br />
Designed in cooperation with Lasos <strong>GmbH</strong>, Jena<br />
BHL-600 picosecond diode lasers<br />
Wavelengths from 635 nm to 1300 nm<br />
Repetition rate 50 MHz<br />
Short pulse width typ. 40 to 50 ps<br />
Power typ. 0.3 mW<br />
All driver electronics integrated<br />
Simple wall mounted +12V power supply<br />
BHLP-700 picosecond diode lasers<br />
Wavelengths from 635 nm to 875 nm<br />
Repetition rate 50 MHz<br />
High power: Up to 10 mW at 785 nm, 5mW at 685 nm<br />
Pulse width typ. 80 ps at power
Fluorescence Lifetime Microscopy<br />
1500 TCSPC Systems Worldwide<br />
DCS-120 Confocal Scanning FLIM Systems<br />
Complete Confocal Laser Scanning FLIM microscopes<br />
FLIM upgrade for existing conventional microscopes<br />
Scanning by fast galvano mirrors<br />
Two fully confocal detection channels<br />
One or two input channels for bh BDL-SMC picosecond diode lasers<br />
Laser wavelengths 405 nm, 440 nm, 473, 488 nm, 640 nm<br />
High excitation power by beam-profile-corrected laser couplers<br />
One or two detection channels, parallel acquisition<br />
Channel separation by dichroic or polarising beamsplitters<br />
Individually selectable pinholes<br />
Individually selectable filters<br />
High efficiency by direct-coupled detectors<br />
GaAsP hybrid detectors<br />
16-channel multi-wavelength detector module<br />
Z-stack FLIM acquisition with Zeiss Axio Observer Z1<br />
New! Simultaneous fluorescence and phosphorescence lifetime imaging (PLIM)<br />
New! Fluorescence lifetime-transient scanning (FLITS)<br />
New! Multiphoton (MP) version<br />
New! Wideband (WB) version: Lasers freely swappable, compatible with tuneable<br />
lasers<br />
New! Electronic alignment<br />
New! DCS-120 Macro System<br />
FLIM of macroscopic objects<br />
Scan field up to 15 mm diameter<br />
Scanning by fast galvano mirrors<br />
Two fully confocal detection channels<br />
Laser wavelengths 405 nm, 440 nm, 473, 488 nm, 640 nm<br />
Wideband version for tuneable excitation<br />
GaAsP hybrid detectors<br />
FLIM Systems for Zeiss LSM 710 Family Microscopes<br />
LSM 710 NLO, LSM 780 NLO, LSM 7MP Multiphoton Microscopes<br />
LSM 710, LSM 780 Confocal Microscopes<br />
LSM 710, LSM 780 In Tune systems<br />
Multiphoton NDD FLIM<br />
Multiphoton NDD multispectral FLIM<br />
Confocal FLIM<br />
Confocal multispectral FLIM<br />
Confocal FCS, multiphoton FCS<br />
Fast preview mode<br />
Time-series FLIM<br />
Confocal Intune tuneable excitation FLIM and FCS<br />
Z Stack FLIM<br />
Unprecedented efficiency by GaAsP hybrid detectors<br />
Acquisition by 1, 2, 3 or 4 parallel TCSPC FLIM channels<br />
New! Simultaneous fluorescence and phosphorescence lifetime imaging (PLIM)<br />
New! Fluorescence lifetime-transient scanning (FLITS)<br />
New! Integrated version - operated from LSM 710 keyboard<br />
FLIM Systems for Zeiss LSM 510 NLO Multiphoton<br />
Microscopes<br />
Non-descanned detection<br />
Detectors connected to Zeiss NDD switch box<br />
All options of NDD light path available<br />
Single-wavelength NDD FLIM<br />
Dual-wavelength NDD FLIM<br />
Multi-spectral NDD FLIM<br />
HPM-100-40 hybrid detectors<br />
ROI and Zoom functions of LSM 510 available<br />
Works at any scan rate of LSM 510<br />
Ultra-high time resolution: 30 ps IRF with MCP detector<br />
Fast acquisition, fast preview mode<br />
Full overload protection of detectors<br />
One or two parallel SPC-830 or SPC-150 TCSPC channels<br />
PC based systems or Simple-Tau<br />
Controlled by Zeiss LSM 510 in conjunction with bh SPCM software<br />
FLIM Systems for Zeiss LSM 510 Confocal Microscopes<br />
Excitation by bh BDL-405 SMC picosecond diode laser<br />
Confocal detection<br />
Single wavelength detection<br />
Multi-spectral detection<br />
ROI and Zoom functions of LSM 510 available<br />
Works at any scan rate of LSM 510<br />
Fast Acquisition, fast preview mode<br />
Overload protection of detectors<br />
PC based systems or Simple-Tau<br />
Controlled by Zeiss LSM 510 in conjunction with bh SPCM software<br />
bh catalog 2013 9
Technology Leader in Photon Counting<br />
FLIM Systems for Leica SP2, SP5, SP8 Microscopes<br />
bh TCSPC technique fully integrated into Leica systems<br />
Confocal detection<br />
Direct (RLD) detection for multiphoton microscopes<br />
Single wavelength detection<br />
Multi-spectral detection<br />
FCS capability<br />
ROI and Zoom functions of SP2 and SP5 available<br />
Works at any scan rate of SP2 and SP5<br />
Wavelength scan function of SP2 applicable<br />
Fast Acquisition, fast preview mode<br />
Full overload protection of detectors<br />
Controlled by Leica SP2 or SP5 in conjunction with bh SPCM software<br />
Non-Descanned FLIM Systems for Leica SP2 MP,<br />
SP5 MP, SP8 MP Microscopes<br />
Non-descanned detection via Leica RLD port<br />
1 detector coupled directly to RLD port<br />
2 detectors via external beamsplitter<br />
Simple-Tau 150 or 152 TCSPC systems<br />
Acquisition in 1 or 2 parallel TCSPC FLIM channels<br />
bh PMC-100-1 cooled PMT modules<br />
New! HPM-100-40 hybrid detectors<br />
bh MW FLIM multi-spectral FLIM detector<br />
ROI and Zoom functions of SP2 and SP5 available<br />
Works at any scan rate of SP2 and SP5<br />
Wavelength scan function of SP2 applicable<br />
Fast acquisition, fast preview mode<br />
FLIM Systems for Olympus FV1000 and FV300 Confocals<br />
Excitation by bh BDL-405 SMC or BDL-473 SMC picosecond diode laser<br />
High efficiency by direct coupling of detectors<br />
Single-wavelength detection: PMT, MCP-PMT, or Hybrid PMT<br />
Multi-wavelength detection: bh PML-SPEC detector<br />
Full overload protection of detectors<br />
ROI and Zoom functions of FV1000 or FV300 available<br />
Works at any scan rate<br />
FCS capability<br />
Non-descanned FLIM Systems for Olympus FV1000 and<br />
FV300 Multiphoton Microscopes<br />
Multiphoton FV1000 and FV300 systems with inverted microscopes<br />
High efficiency by non-descanned FLIM detection<br />
Deep-tissue imaging capability<br />
Single-wavelength detection: PMT, MCP-PMT, or Hybrid PMT<br />
Multi-spectral FLIM by bh MW FLIM detector<br />
Full overload protection of detectors<br />
ROI and Zoom functions of FV1000 or FV300 available<br />
Works at any scan rate<br />
10 bh catalog 2013
1500 TCSPC Systems Worldwide<br />
Time-Domain Diffuse Optical Tomography<br />
Modular DOT systems<br />
Several BHLP-700 lasers of different wavelengths multiplexed<br />
Time-of -flight distributions in four wavelength channels and four spatial channels<br />
Four parallel detectors<br />
Four parallel TCSPC channels<br />
DDG-200 digital delay generator<br />
SPC-154 or SPC-134 TCSPC packages<br />
Detector control via DCC-100 cards<br />
Saturated count rates up to 40 MHz<br />
Multiplexing periods of lasers individually programmable<br />
Unlimited sequential recording by continuous flow mode<br />
Acquisition rate up to 20 time-of-flight distributions per second<br />
Connecting Electronics<br />
Delay Switch Box<br />
32 step passive delay line<br />
Delay from 0 to 31.5 ns in 0.5 ns steps<br />
Transmits any signal waveform<br />
Signal Bandwidth 1 GHz<br />
No noise, no jitter<br />
No external power supply needed<br />
Settings persist when box is disconnected from USB<br />
Easy adjustment of TCSPC SYNC path length<br />
Control integrated in bh SPCM TCSPC operating software<br />
BOB-4 Signal Distribution Box<br />
Distributes scan clock signals to four SPC modules<br />
Combines routing signals and other control signals into 15-pin control inputs of four SPC-130,<br />
-140, and -150 modules<br />
Auxiliary +12V input for power supply of amplifiers, routers, detectors<br />
BOB-1 Signal Distribution Box<br />
Combines routing signals and other control signals into 15-pin control inputs of one SPC-130,<br />
-140, and -150 module<br />
Auxiliary +12V input for power supply of amplifiers, routers, detectors<br />
DCS Connection Box<br />
Power supply and control of two bh BDL-SMC ps diode lasers<br />
Connects scan clocks and laser multiplexing signals of GVD-120 scan controller into two<br />
SPC-150 or SPC-830 modules and two BDL-SMC diode lasers<br />
Connects routing signals of two bh multi-spectral FLIM detectors into SPC modules<br />
Cables and Adapters<br />
A-PPI-D passive pulse inverters<br />
1:3, 1:4 power splitters and combiners<br />
Attenuators<br />
SMA cables<br />
SMA-to SMA adapters<br />
SMA-to BNC adapters<br />
Power supply cables for detectors<br />
Interface cables for bh FLIM systems for various laser scanning microscopes<br />
A reasonable set of cables and adapters is delivered with each bh SPC module or Simple-Tau<br />
system<br />
bh catalog 2013 11
Technology Leader in Photon Counting<br />
TCSPC Literature from the Technology Leader<br />
Wolfgang <strong>Becker</strong><br />
Advanced Time-Correlated Single Photon Counting<br />
Techniques<br />
400 pages, 349 figures, 557 references<br />
Springer 2005, ISBN 3-540-26047-1<br />
Please contact bh for your personal copy<br />
Wolfgang <strong>Becker</strong><br />
The bh TCSPC Handbook<br />
5th Edition, 2012<br />
690 pages, 771 figures, 823 references<br />
Available from www.becker-hickl.com<br />
Please contact bh for printed copies<br />
DCS-120 Confocal Scanning FLIM Systems<br />
Edition 2012<br />
204 pages, 165 references, 273 figures<br />
Available from www.becker-hickl.com<br />
Modular FLIM Systems for Zeiss<br />
LSM 510 and LSM 710 Laser Scanning Microscopes<br />
5th edition, August 2012<br />
258 pages, 330 figures, 243 references<br />
Available from www.becker-hickl.com<br />
Leica MP-FLIM and D-FLIM<br />
Fluorescence Lifetime Microscopy Systems<br />
63 pages, 58 figures, 101 references<br />
Available from www.becker-hickl.com<br />
Modular FLIM Systems for Olympus Laser Scanning<br />
Microscope Fluo View FV1000<br />
103 pages, 106 figures, 104 references<br />
Available from www.becker-hickl.com<br />
BDL-SMC NUV and Blue Picosecond Diode Lasers<br />
User Handbook<br />
41 pages, 46 figures, 23 references<br />
Available from www.becker-hickl.com<br />
DPC-230 16 Channel Photon Correlator<br />
User Handbook<br />
April 2008<br />
66 pages, 89 figures, 31 references<br />
Available from www.becker-hickl.com<br />
PML-16-C 16 Channel Detector Head for<br />
Time-Correlated Single Photon Counting<br />
User Handbook<br />
39 pages, 40 figures, 28 references<br />
Available from www.becker-hickl.com<br />
12 bh catalog 2013
Instrument Software<br />
1500 TCSPC Systems Worldwide<br />
SPCM Data Acquisition Software for<br />
bh TCSPC modules<br />
One software for all bh TCSPC modules<br />
Full access to all functions of the boards<br />
Configurable for different instrument configurations<br />
Easy change between different configurations<br />
Parallel operation of up to four SPC or DPC modules<br />
Online display of images and curves<br />
Online calculation of FCS, PCH, and MCS traces<br />
Online fit of FCS curves<br />
Page stepping<br />
Accumulation and autosave functions<br />
Oscilloscope mode<br />
Single and repeat mode<br />
Sequential modes<br />
Imaging modes<br />
Time tag mode<br />
Time tag imaging mode<br />
Integrated scanner control<br />
Interaction of scanner control with display cursors<br />
2D and 3D display modes<br />
3D Curve mode, colour-intensity mode<br />
Software gating of image display<br />
Display of multi-wavelength FLIM images<br />
Saving, loading, and conversion of photon distributions,<br />
images, and time-tag data<br />
Loading of predefined setups<br />
2D and 3D data processing functions<br />
Automatic interaction with SPCImage FLIM data analysis<br />
Scanner control via GVD-120 card<br />
Z-Axis drive of Zeiss Axio Observer<br />
Emulation mode for working without SPC hardware<br />
Runs under Windows 2000, NT, XP, Vista<br />
The SPCM software is free. It can be downloaded from<br />
www.becker-hickl.com.<br />
Operating Software for DCC-100 Detector<br />
controller<br />
Safe operation of PMTs, PMT Modules, and MCPs<br />
Control of high voltage of PMT modules or high voltage power<br />
supplies<br />
Control of shutters<br />
Control of coolers<br />
DCC panel can be placed anywhere within SPCM or MSA<br />
software panels<br />
Runs under windows 2000, NT, XP, Vista<br />
The DCC software is free. It can be downloaded from<br />
www.becker-hickl.com.<br />
bh catalog 2013 13
Technology Leader in Photon Counting<br />
Operating Software for bh Multichannel Scalers<br />
Setting of system parameters<br />
Configuration of measurement sequences<br />
Data display<br />
Data processing<br />
Load and save of measurement data and setup parameters<br />
Operation of up to four modules<br />
Emulation mode to work without hardware<br />
Runs under windows 2000, NT, XP, Vista<br />
The MSA and PMS software is free. It can be downloaded from www.beckerhickl.com<br />
at any time.<br />
Data Analysis Software<br />
SPCImage FLIM Data Analysis Software<br />
Deconvolution of single curves and FLIM data<br />
Single, double, and triple-exponential decay analysis<br />
Single and double-exponential FRET<br />
Display of lifetime images<br />
Display of FRET images<br />
Display of lifetimes, amplitudes, intensities or ratios of these<br />
parameters<br />
Histograms of lifetimes, amplitudes, intensities or ratios of these<br />
parameters<br />
Export of lifetime data<br />
Export of images<br />
Direct interaction with SPCM software<br />
Optispec FLIM Data Analysis Software<br />
Deconvolution of single curves and FLIM data<br />
Single, double, and triple-exponential decay analysis<br />
Single and double-exponential FRET<br />
Automatic processing of multi-curve data<br />
Automatic processing of multi-spectral FLIM data<br />
Automatic processing of sequential FLIM measurements<br />
Global fitting of selected parameters<br />
Display of lifetime images<br />
Display of FRET images<br />
Display of lifetimes, amplitudes, intensities or ratios of these<br />
parameters<br />
Histograms of lifetimes, amplitudes, intensities or ratios of these<br />
parameters<br />
Export of lifetime data<br />
Export of images<br />
Direct interaction with SPCM software<br />
DLL and Lab View Libraries for TCSPC and Multiscaler Modules<br />
DLL libraries are available for most bh data acquisition and experiment control modules.<br />
We recommend, however, to check whether the desired effects can be obtained by using the hardware<br />
control features of our modules. Please contact bh for details.<br />
14 bh catalog 2013
1500 TCSPC Systems Worldwide<br />
Design, Manufacturing and Quality Management<br />
A Strong Partnership<br />
bh and Dorazil form an alliance since 1993. Located in the same building, our<br />
companies closely cooperate at all stages through schematics design, hybrid<br />
circuit design, board layout, and computer-aided manufacturing and testing.<br />
Continuous quality management through the complete design and<br />
manufacturing flow results in high reliability and short delivery time both for<br />
prototypes and large order quantities.<br />
Continuous flow from design into manufacturing<br />
Hybrid-circuit, FPGA, and PCB design<br />
Electronics running off the mill<br />
High-density automatic SMD placement<br />
Automatic soldering<br />
ROHS lead-free<br />
Thin film and thick film hybrid circuits<br />
In-house manufacturing<br />
Automatic placement of components<br />
Automatic chip bonding<br />
ISO 9000 certified<br />
Quality management though whole manufacturing process<br />
Uncompromised quality at any number of pieces<br />
bh catalog 2013 15
<strong>Becker</strong> & <strong>Hickl</strong> <strong>GmbH</strong><br />
Nahmitzer Damm 30, 12277 Berlin, Germany<br />
Tel. +49 / 30 / 787 56 32 Fax. +49 / 30 / 787 57 34<br />
email: info@becker-hickl.com<br />
www.becker-hickl.com