You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Titration</strong> <strong>Softw</strong><strong>are</strong><br />
Key New Features at a Glance<br />
LabX titration 3.0<br />
Smartcodes <br />
Label your samples with a bar code and<br />
LabX will find the corresponding titration<br />
method for every sample. The method is<br />
encoded in the Smartcode and<br />
automatically selected when read in with<br />
the barcode reader. Efficient operation is<br />
combined with advanced security (LabX<br />
pro only).<br />
Active series editing<br />
Waiting or active sample series can be<br />
modified with the sample data editor:<br />
non-processed samples can be edited,<br />
added or deleted or the sequence within<br />
a series can be changed. Flexibility is<br />
further improved with smart drag-anddrop<br />
and copy-paste functionality that<br />
also allows to change the sequence of<br />
queued sample series.<br />
Immediate information<br />
The Online screen shows all measured<br />
data immediately in easily legible<br />
numbers and letters next to the online<br />
curve. The user is always informed and<br />
has direct access to all tasks with the<br />
new Karl Fischer toolbar. Operation and<br />
information is fast and direct.<br />
Karl Fischer titration<br />
The new line of METTLER TOLEDO Karl<br />
Fischer titrators is fully supported.<br />
Volumetric and coulometric Compact as<br />
well as the Excellence T70 and T90<br />
titrators with volumetric Karl Fischer<br />
functionality <strong>are</strong> controlled by the PC<br />
softw<strong>are</strong> offering simple and secure One<br />
Click water determination.<br />
LabX titration 3.0 with<br />
<strong>Titration</strong> Compact line<br />
The new Karl Fischer titrators of the Compact line and<br />
the existing Excellence titrators in version 3.0 <strong>are</strong> fully<br />
supported as well as the older DL series.<br />
• New KF toolbar for direct start of sample, concentration,<br />
blank or drift determinations and stop of KF<br />
method and KF series.<br />
• Direct sample data entry and choice of Rondo starting<br />
position after method start including Shortcut<br />
functionality.<br />
• Result and formula proposals in the Method editor<br />
• All three sample IDs <strong>are</strong> displayed in Online View,<br />
Reports and Report tree.<br />
• Create a new result in the recalculation dialog<br />
• Windows ® Vista support.
LabX Smartcodes : Three simple and secure steps to your titration result (LabX pro only)<br />
Step 1:<br />
Assign sample bar code to<br />
a titration method with the<br />
Smartcode table<br />
Use the sample ID for method<br />
assignment<br />
Step 2:<br />
Scan the sample‘s bar code<br />
with bar code scanner<br />
The assigned method is automatically<br />
started on a T70, T90, C30 or<br />
V30 titrator. The sample weight is<br />
transferred from a connected balance<br />
via dialog. Each new sample<br />
using the same method is added to<br />
a series.<br />
Step 3:<br />
Your titration result is<br />
safely stored in the<br />
LabX result data base<br />
Control charts and individual<br />
search filters provide efficient result<br />
management.<br />
List of new features of LabX titration pro and light version 3.0<br />
Abstract<br />
New KF specific features<br />
Description<br />
Support of specific KF resources such as KF titration stands (Stromboli, Manual titration stand), TTL-Homogenizer (V30,<br />
T70, T90), RS232-C Homogenizer (T70, T90) and Solvent Control (C30, V30, T70, T90, monitoring of solvent usable life,<br />
capacity and number of samples).<br />
KF method functionality Sample specific METTLER TOLEDO methods with tested parameters for immediate use for volumetric (V30, T70, T90)<br />
and coulometric (C30) Karl Fischer titrators including Stromboli automation and external extraction/dissolution. Standard<br />
method templates for volumetric (V20, V30, T70, T90) and coulometric (C20, C30) Karl Fischer titrations for easy method<br />
development.<br />
Expanded result management<br />
Rinse multiple burettes<br />
Automatic renumbering of samples after generation of new results during a running sample series.<br />
The simultaneous rinsing of up to four burettes can be started in OneClick. The required Dosing units <strong>are</strong> selected in the<br />
manual funtion ‘Rinse Multiple Burettes’ and a Shortcut is defined. If more than four burettes <strong>are</strong> selected the first four <strong>are</strong><br />
rinsed according to the defined cycles followed by the simultaneous rinsing of the remaining burettes.<br />
Quality certificate ISO9001<br />
Environment certificate ISO14001<br />
Internet: www.mt.com<br />
Worldwide service<br />
Subject to technical changes<br />
© 06/2008 <strong>Mettler</strong>-<strong>Toledo</strong> AG<br />
Printed in Switzerland 51725117<br />
MarCom Analytical<br />
www.mt.com<br />
For more information