Certificate of Compliance<br />

Certificate: 2262749 (LR 38879C) Master Contract: 173688<br />

Project: 2262749 Date Issued: 2010/01/28<br />

Issued to:<br />

<strong>Power</strong>-<strong>One</strong>, Inc<br />

740 Calle Plano<br />

Camarillo, CA 93012<br />

USA<br />

Attention: Ms. Editha Vergara<br />

The products listed below are eligible to bear the CSA<br />

Mark shown with adjacent indicators 'C' and 'US' for<br />

Canada and US or with adjacent indicator 'US' for<br />

US only or without either indicator for Canada only.<br />

Issued by:<br />

Gwang-Yeol Park, Eng.<br />

Gwang-Yeol Park, Eng.<br />

PRODUCTS<br />

CLASS 5311 11<br />

CLASS 5311 91<br />

- POWER SUPPLIES - Component Type(CSA 60950-1-07-2nd Ed)<br />

- POWER SUPPLIES - Component Type(UL 60950-1-2nd Ed)Certified to<br />

U.S.Stds<br />

DC-DC <strong>Power</strong> Supply, Model 20/40 IMX (standard type) and KMX (custom type) series.<br />

For details related to rating, size, configuration, etc., reference should be made to the CSA Certification Record<br />

or the Descriptive Report.<br />

Notes:<br />

1. “G” suffix may be followed by a dash (-) and suffix letters and/or numbers denoting non-safety-critical<br />

options (unless described otherwise in the report) such as, but not limited to, open frame, positive or negative<br />

shut down, non-standard pin configuration, increased electric strength, etc.<br />

2. Any combination of input voltage and output voltages shown above creates a valid model number.<br />

3. In addition to model(s) listed above, following custom model number(s) may be used with the exact model<br />

number listed below: Custom Model Designation: 40KMX35MMTH-S1. (Input Voltage Rating: 18-75 V dc;<br />

48/60 V dc nominal. Output Ratings: 6V @ 1.97A, -7.3V @ 130mA, 7.3V @ 1.55A, 14V @ 30mA.)<br />

CONDITIONS OF ACCEPTABILITY<br />

1. All secondary output circuits are SELV and are not hazardous energy levels.<br />

DQD 507 Rev. 2009-09-01


Certificate: 2262749 (LR 38879C) Master Contract: 173688<br />

Project: 2262749 Date Issued: 2010/01/28<br />

2. All models are intended to be supplied from an isolated secondary circuit.<br />

3. The input/output connectors are not acceptable for field wiring and are only intended for connection to<br />

mating connectors of the internal wiring inside the end-use product. The acceptability of these and the mating<br />

connectors relative to secureness, insulation materials, and temperatures shall be considered.<br />

4. A suitable Electrical, Fire and Mechanical enclosure shall be provided.<br />

5. All models were submitted and tested for a maximum manufacturer’s recommended ambient<br />

operating temperature of 110ºC for -8 models and 71ºC for -9 models, and 80ºC for 40KMX35MMTH-<br />

S1, 40KMX35MMTH-S2 and 40KMX35MTTJ-S2 models. Consideration should be given to measure the<br />

temperatures on the unit when the converter is installed in the end-use equipment.<br />

6. The maximum working voltage present is 77 V rms, 150 V pk for Model 40IMX35D15D15-8Z, and<br />

83 V rms, 212 V pk for model 40KMX35MMTH-S1. The Electric Strength Tests in the end product shall be<br />

based on these values.<br />

7. The units were tested for an input voltage range per the tables in the Nomenclature and Electrical<br />

ratings section of this report with zero tolerance. If used outside these voltage ranges, additional testing may be<br />

required.<br />

8. Special enclosure consideration should be given to the end-use installation. Hazardous voltage<br />

is available on the surface of the PWB. The end-use product should be reviewed to determine whether<br />

accessibility requirements are met for the end-use product.<br />

9. Special spacing consideration should be given to the end-use product as the spacings between the unit<br />

and mounting surface have not been evaluated.<br />

10. Abnormal and Component Failure Tests on all models except 20IMX35 and 20KMX35 were conducted<br />

with the power supply input protected by certified fuse, rated F, 125 V dc, 5 A. If a fuse rated greater than 5 A<br />

is used, additional testing may be required.<br />

Component Failure test on models 20IMX35 and 20KMX35 were conducted with input protected by<br />

certified fuse, rated 125 V dc, 8 A. If a fuse rated greater than 8 A is used and not certified, additional testing<br />

may be required.<br />

11. For the purpose of applying insulation requirements, the input to this DC to DC converter is identified as<br />

TNV-2 or SELV, therefore, basic insulation based on 75 V dc input is provided between the input and output of<br />

the converter. An additional evaluation is needed if the source is other than TNV-2 or SELV.<br />

12. Model 40KMX35MTTJ-S2 has been evaluated for operational altitude of 4500 m. Per IEC60664-1:<br />

1992 Table A.2. Altitude Correction Factor is 1.4 for the higher Altitude and not intended for use in vehicles, on<br />

board ships or aircraft.<br />

APPLICABLE REQUIREMENTS<br />

CAN/CSA-C22.2 No 60950-1-07 - Information Technology Equipment - Safety - Part 1: General Requirements<br />

ANSI/UL 60950-1, Second Edition - Information Technology Equipment - Safety - Part 1: General<br />

Requirements<br />

DQD 507 Rev. 2009-09-01


Descriptive Report<br />

and Test Results<br />

Edition 1:<br />

January 28, 2010; Project 2262749 - Vancouver<br />

Issued by Gwang-Yeol Park, Eng.<br />

MASTER CONTRACT: 173688 (LR 38879C)<br />

REPORT: 2262749<br />

PROJECT: 2262749<br />

Contents: Certificate of Compliance - Pages 1 to 2<br />

Supplement to Certificate of Compliance - Page 1<br />

Descriptive Report and Tests - Pages 1 to 8<br />

Attachment 1 - List of Critical Components (4 pages)<br />

Attachment 2 - Photographs (6 pages)<br />

Attachment 3 - Schematics (21 pages) – Not for publication<br />

(Engineering use only)<br />

Bi-Nat CSA 60950-1-03/UL 60950-1 Design Manual, Rev. 2.2<br />

PRODUCTS<br />

CLASS 5311 11 - POWER SUPPLIES - Component Type (CSA 60950-1-07-2 nd Ed)<br />

CLASS 5311 91 - POWER SUPPLIES - Component Type (UL 60950-1-2 nd Ed) - Certified to U.S. Standards<br />

Component type power supplies intended for use with Information Technology and Business Equipment, where<br />

the suitability of the combination is to be determined by CSA International.<br />

DC-DC <strong>Power</strong> Supply, Model 20/40 IMX (standard type) and KMX (custom type) series; specified as follows:<br />

Typical Model designation:<br />

40 IMX 35 D05 D05 - 9Z<br />

I II III IV V VI<br />

I - Input Voltage Ratings: 20 = 09-36 V dc<br />

40 = 18-75 V dc; 48/60 V dc nominal<br />

II - Model Series: IMX or KMX<br />

III - Maximum Output <strong>Power</strong>: 35 = 35 Watts<br />

BI-NAT CSA 60950-1-03/UL 60950-1, 1 st Edition Rev. 2.2 DESIGN MANUAL (ISSUED WITH REPORT<br />

2196792) IS AN INTEGRAL PART OF THIS REPORT<br />

This report shall not be reproduced, except in full, without the approval of CSA International.<br />

2262749 Report_2262749.doc\dw<br />

DQD 507.10 Rev. 2008-11-28


MASTER CONTRACT: 173688 (LR 38879C)<br />

REPORT: 2262749<br />

PROJECT: 2262749<br />

Page No: 2<br />

Date Issued: January 28, 2010<br />

IV - Output Voltage Rating:<br />

V - Output Voltage rating:<br />

1)<br />

-03 = 3 Volts dc<br />

1)<br />

-05 = 5 Volts dc<br />

2)<br />

D05 = 5 Volts dc<br />

2)<br />

D12 = 12 Volts dc<br />

2)<br />

D15 = 15 Volts dc<br />

3)<br />

D05 = 5 Volts dc<br />

3)<br />

D12 = 12 Volts dc<br />

3)<br />

D15 = 15 Volts dc<br />

VI - Options Suffix: (May Be Combined)<br />

8 = -40 to 110ºC (Operating ambient temperature range)<br />

9 = -40 to 71ºC (Operating ambient temperature range)<br />

i = Inhibit<br />

Z = Open Frame<br />

1) - Output No. 1 for models with triple output.<br />

2) - Output No. 1 and 4 for models with quad outputs.<br />

3) - Output No. 2 and 3 for models with quad outputs.<br />

Notes:<br />

1. “G” suffix may be followed by a dash (-) and suffix letters and/or numbers denoting non-safety-critical<br />

options (unless described otherwise in the report) such as, but not limited to, open frame, positive or<br />

negative shut down, non-standard pin configuration, increased electric strength, etc.<br />

2. Any combination of input voltage and output voltages shown above creates a valid model number.<br />

3. In addition to model(s) listed above, following custom model number(s) may be used with the exact<br />

model number listed below:<br />

Custom Model Designation: 40KMX35MMTH-S1. (Input Voltage Rating: 18-75 V dc; 48/60 V dc<br />

nominal. Output Ratings: 6V @ 1.97A, -7.3V @ 130mA, 7.3V @ 1.55A, 14V @ 30mA.)<br />

APPLICABLE REQUIREMENTS<br />

CAN/CSA-C22.2 No 60950-1-07 Information Technology Equipment - Safety - Part 1: General<br />

Requirements<br />

ANSI/UL 60950-1, Second Edition Information Technology Equipment - Safety - Part 1: General<br />

Requirements<br />

CONDITIONS OF ACCEPTABILITY<br />

1. All secondary output circuits are SELV and are not hazardous energy levels.<br />

2. All models are intended to be supplied from an isolated secondary circuit.<br />

3. The input/output connectors are not acceptable for field wiring and are only intended for connection to<br />

mating connectors of the internal wiring inside the end-use product. The acceptability of these and the<br />

mating connectors relative to secureness, insulation materials, and temperatures shall be considered.<br />

2262749 Report_2262749.doc\dw<br />

DQD 507.10 Rev. 2008-11-28


MASTER CONTRACT: 173688 (LR 38879C)<br />

REPORT: 2262749<br />

PROJECT: 2262749<br />

Page No: 3<br />

Date Issued: January 28, 2010<br />

4. A suitable Electrical, Fire and Mechanical enclosure shall be provided.<br />

5. All models were submitted and tested for a maximum manufacturer’s recommended ambient operating<br />

temperature of 110ºC for -8 models and 71ºC for -9 models, and 80ºC for 40KMX35MMTH-S1,<br />

40KMX35MMTH-S2 and 40KMX35MTTJ-S2 models. Consideration should be given to measure the<br />

temperatures on the unit when the converter is installed in the end-use equipment.<br />

6. The maximum working voltage present is 77 V rms, 150 V pk for Model 40IMX35D15D15-8Z, and<br />

83 V rms, 212 V pk for model 40KMX35MMTH-S1. The Electric Strength Tests in the end product shall<br />

be based on these values.<br />

7. The units were tested for an input voltage range per the tables in the Nomenclature and Electrical ratings<br />

section of this report with zero tolerance. If used outside these voltage ranges, additional testing may be<br />

required.<br />

8. Special enclosure consideration should be given to the end-use installation. Hazardous voltage is<br />

available on the surface of the PWB. The end-use product should be reviewed to determine whether<br />

accessibility requirements are met for the end-use product.<br />

9. Special spacing consideration should be given to the end-use product as the spacings between the unit and<br />

mounting surface have not been evaluated.<br />

10. Abnormal and Component Failure Tests on all models except 20IMX35 and 20KMX35 were conducted<br />

with the power supply input protected by certified fuse, rated F, 125 V dc, 5 A. If a fuse rated greater<br />

than 5 A is used, additional testing may be required.<br />

Component Failure test on models 20IMX35 and 20KMX35 were conducted with input protected by<br />

certified fuse, rated 125 V dc, 8 A. If a fuse rated greater than 8 A is used and not certified, additional<br />

testing may be required.<br />

11. For the purpose of applying insulation requirements, the input to this DC to DC converter is identified as<br />

TNV-2 or SELV, therefore, basic insulation based on 75 V dc input is provided between the input and<br />

output of the converter. An additional evaluation is needed if the source is other than TNV-2 or SELV.<br />

12. Model 40KMX35MTTJ-S2 has been evaluated for operational altitude of 4500 m. Per IEC60664-1: 1992<br />

Table A.2. Altitude Correction Factor is 1.4 for the higher Altitude and not intended for use in vehicles,<br />

on board ships or aircraft.<br />

MARKINGS<br />

Marking Method:<br />

- CSA accepted and UL recognized adhesive nameplate, suitable for the surface to which it is applied.<br />

Marking consists of Company Name and Series identification etched in PWB trace patterns.<br />

- Due to insufficient surface to which a CSA Mark can be applied after all other necessary markings have<br />

been applied (i.e. free, markable surface less than 1 cm 2 ), the CSA Mark may be applied to the smallest<br />

unit of packaging containing the certified product.<br />

Note: Refer to the Design Manual for other marking option.<br />

2262749 Report_2262749.doc\dw<br />

DQD 507.10 Rev. 2008-11-28


Declaration of Conformity<br />

CE MARKING<br />

We, <strong>Power</strong>-<strong>One</strong>, Inc.,740 Calle Plano, Camarillo, CA. 93012 USA<br />

declare under our sole responsibility that the products;<br />

<strong>Power</strong> Supply Model:<br />

IMX35, KMX35 Series<br />

to which this declaration relates, is/are in compliance with the following document(s):<br />

Quality Standard(s): ISO 9001, EN 29001<br />

Directive:<br />

DIR 2006/95/EC, Low Voltage Directive<br />

Product Safety Standard(s): EN 60950-1: 2006<br />

IEC 60950-1: 2005<br />

(Licensed by a Notified Body to the European Union )<br />

These component level power supplies are intended exclusively for inclusion within other<br />

equipment by an industrial assembly operation or by professional installers per the<br />

Installation Instructions provided with the power supplies.<br />

Camarillo, Ca. June 29, 2010<br />

(Manufacturer) (Place) (Date)<br />

Robert P. White Jr.<br />

Director of Safety and<br />

Environmental Compliance