Certificate of Compliance<br />
Certificate: 2262749 (LR 38879C) Master Contract: 173688<br />
Project: 2262749 Date Issued: 2010/01/28<br />
Issued to:<br />
<strong>Power</strong>-<strong>One</strong>, Inc<br />
740 Calle Plano<br />
Camarillo, CA 93012<br />
USA<br />
Attention: Ms. Editha Vergara<br />
The products listed below are eligible to bear the CSA<br />
Mark shown with adjacent indicators 'C' and 'US' for<br />
Canada and US or with adjacent indicator 'US' for<br />
US only or without either indicator for Canada only.<br />
Issued by:<br />
Gwang-Yeol Park, Eng.<br />
Gwang-Yeol Park, Eng.<br />
PRODUCTS<br />
CLASS 5311 11<br />
CLASS 5311 91<br />
- POWER SUPPLIES - Component Type(CSA 60950-1-07-2nd Ed)<br />
- POWER SUPPLIES - Component Type(UL 60950-1-2nd Ed)Certified to<br />
U.S.Stds<br />
DC-DC <strong>Power</strong> Supply, Model 20/40 IMX (standard type) and KMX (custom type) series.<br />
For details related to rating, size, configuration, etc., reference should be made to the CSA Certification Record<br />
or the Descriptive Report.<br />
Notes:<br />
1. “G” suffix may be followed by a dash (-) and suffix letters and/or numbers denoting non-safety-critical<br />
options (unless described otherwise in the report) such as, but not limited to, open frame, positive or negative<br />
shut down, non-standard pin configuration, increased electric strength, etc.<br />
2. Any combination of input voltage and output voltages shown above creates a valid model number.<br />
3. In addition to model(s) listed above, following custom model number(s) may be used with the exact model<br />
number listed below: Custom Model Designation: 40KMX35MMTH-S1. (Input Voltage Rating: 18-75 V dc;<br />
48/60 V dc nominal. Output Ratings: 6V @ 1.97A, -7.3V @ 130mA, 7.3V @ 1.55A, 14V @ 30mA.)<br />
CONDITIONS OF ACCEPTABILITY<br />
1. All secondary output circuits are SELV and are not hazardous energy levels.<br />
DQD 507 Rev. 2009-09-01
Certificate: 2262749 (LR 38879C) Master Contract: 173688<br />
Project: 2262749 Date Issued: 2010/01/28<br />
2. All models are intended to be supplied from an isolated secondary circuit.<br />
3. The input/output connectors are not acceptable for field wiring and are only intended for connection to<br />
mating connectors of the internal wiring inside the end-use product. The acceptability of these and the mating<br />
connectors relative to secureness, insulation materials, and temperatures shall be considered.<br />
4. A suitable Electrical, Fire and Mechanical enclosure shall be provided.<br />
5. All models were submitted and tested for a maximum manufacturer’s recommended ambient<br />
operating temperature of 110ºC for -8 models and 71ºC for -9 models, and 80ºC for 40KMX35MMTH-<br />
S1, 40KMX35MMTH-S2 and 40KMX35MTTJ-S2 models. Consideration should be given to measure the<br />
temperatures on the unit when the converter is installed in the end-use equipment.<br />
6. The maximum working voltage present is 77 V rms, 150 V pk for Model 40IMX35D15D15-8Z, and<br />
83 V rms, 212 V pk for model 40KMX35MMTH-S1. The Electric Strength Tests in the end product shall be<br />
based on these values.<br />
7. The units were tested for an input voltage range per the tables in the Nomenclature and Electrical<br />
ratings section of this report with zero tolerance. If used outside these voltage ranges, additional testing may be<br />
required.<br />
8. Special enclosure consideration should be given to the end-use installation. Hazardous voltage<br />
is available on the surface of the PWB. The end-use product should be reviewed to determine whether<br />
accessibility requirements are met for the end-use product.<br />
9. Special spacing consideration should be given to the end-use product as the spacings between the unit<br />
and mounting surface have not been evaluated.<br />
10. Abnormal and Component Failure Tests on all models except 20IMX35 and 20KMX35 were conducted<br />
with the power supply input protected by certified fuse, rated F, 125 V dc, 5 A. If a fuse rated greater than 5 A<br />
is used, additional testing may be required.<br />
Component Failure test on models 20IMX35 and 20KMX35 were conducted with input protected by<br />
certified fuse, rated 125 V dc, 8 A. If a fuse rated greater than 8 A is used and not certified, additional testing<br />
may be required.<br />
11. For the purpose of applying insulation requirements, the input to this DC to DC converter is identified as<br />
TNV-2 or SELV, therefore, basic insulation based on 75 V dc input is provided between the input and output of<br />
the converter. An additional evaluation is needed if the source is other than TNV-2 or SELV.<br />
12. Model 40KMX35MTTJ-S2 has been evaluated for operational altitude of 4500 m. Per IEC60664-1:<br />
1992 Table A.2. Altitude Correction Factor is 1.4 for the higher Altitude and not intended for use in vehicles, on<br />
board ships or aircraft.<br />
APPLICABLE REQUIREMENTS<br />
CAN/CSA-C22.2 No 60950-1-07 - Information Technology Equipment - Safety - Part 1: General Requirements<br />
ANSI/UL 60950-1, Second Edition - Information Technology Equipment - Safety - Part 1: General<br />
Requirements<br />
DQD 507 Rev. 2009-09-01
Descriptive Report<br />
and Test Results<br />
Edition 1:<br />
January 28, 2010; Project 2262749 - Vancouver<br />
Issued by Gwang-Yeol Park, Eng.<br />
MASTER CONTRACT: 173688 (LR 38879C)<br />
REPORT: 2262749<br />
PROJECT: 2262749<br />
Contents: Certificate of Compliance - Pages 1 to 2<br />
Supplement to Certificate of Compliance - Page 1<br />
Descriptive Report and Tests - Pages 1 to 8<br />
Attachment 1 - List of Critical Components (4 pages)<br />
Attachment 2 - Photographs (6 pages)<br />
Attachment 3 - Schematics (21 pages) – Not for publication<br />
(Engineering use only)<br />
Bi-Nat CSA 60950-1-03/UL 60950-1 Design Manual, Rev. 2.2<br />
PRODUCTS<br />
CLASS 5311 11 - POWER SUPPLIES - Component Type (CSA 60950-1-07-2 nd Ed)<br />
CLASS 5311 91 - POWER SUPPLIES - Component Type (UL 60950-1-2 nd Ed) - Certified to U.S. Standards<br />
Component type power supplies intended for use with Information Technology and Business Equipment, where<br />
the suitability of the combination is to be determined by CSA International.<br />
DC-DC <strong>Power</strong> Supply, Model 20/40 IMX (standard type) and KMX (custom type) series; specified as follows:<br />
Typical Model designation:<br />
40 IMX 35 D05 D05 - 9Z<br />
I II III IV V VI<br />
I - Input Voltage Ratings: 20 = 09-36 V dc<br />
40 = 18-75 V dc; 48/60 V dc nominal<br />
II - Model Series: IMX or KMX<br />
III - Maximum Output <strong>Power</strong>: 35 = 35 Watts<br />
BI-NAT CSA 60950-1-03/UL 60950-1, 1 st Edition Rev. 2.2 DESIGN MANUAL (ISSUED WITH REPORT<br />
2196792) IS AN INTEGRAL PART OF THIS REPORT<br />
This report shall not be reproduced, except in full, without the approval of CSA International.<br />
2262749 Report_2262749.doc\dw<br />
DQD 507.10 Rev. 2008-11-28
MASTER CONTRACT: 173688 (LR 38879C)<br />
REPORT: 2262749<br />
PROJECT: 2262749<br />
Page No: 2<br />
Date Issued: January 28, 2010<br />
IV - Output Voltage Rating:<br />
V - Output Voltage rating:<br />
1)<br />
-03 = 3 Volts dc<br />
1)<br />
-05 = 5 Volts dc<br />
2)<br />
D05 = 5 Volts dc<br />
2)<br />
D12 = 12 Volts dc<br />
2)<br />
D15 = 15 Volts dc<br />
3)<br />
D05 = 5 Volts dc<br />
3)<br />
D12 = 12 Volts dc<br />
3)<br />
D15 = 15 Volts dc<br />
VI - Options Suffix: (May Be Combined)<br />
8 = -40 to 110ºC (Operating ambient temperature range)<br />
9 = -40 to 71ºC (Operating ambient temperature range)<br />
i = Inhibit<br />
Z = Open Frame<br />
1) - Output No. 1 for models with triple output.<br />
2) - Output No. 1 and 4 for models with quad outputs.<br />
3) - Output No. 2 and 3 for models with quad outputs.<br />
Notes:<br />
1. “G” suffix may be followed by a dash (-) and suffix letters and/or numbers denoting non-safety-critical<br />
options (unless described otherwise in the report) such as, but not limited to, open frame, positive or<br />
negative shut down, non-standard pin configuration, increased electric strength, etc.<br />
2. Any combination of input voltage and output voltages shown above creates a valid model number.<br />
3. In addition to model(s) listed above, following custom model number(s) may be used with the exact<br />
model number listed below:<br />
Custom Model Designation: 40KMX35MMTH-S1. (Input Voltage Rating: 18-75 V dc; 48/60 V dc<br />
nominal. Output Ratings: 6V @ 1.97A, -7.3V @ 130mA, 7.3V @ 1.55A, 14V @ 30mA.)<br />
APPLICABLE REQUIREMENTS<br />
CAN/CSA-C22.2 No 60950-1-07 Information Technology Equipment - Safety - Part 1: General<br />
Requirements<br />
ANSI/UL 60950-1, Second Edition Information Technology Equipment - Safety - Part 1: General<br />
Requirements<br />
CONDITIONS OF ACCEPTABILITY<br />
1. All secondary output circuits are SELV and are not hazardous energy levels.<br />
2. All models are intended to be supplied from an isolated secondary circuit.<br />
3. The input/output connectors are not acceptable for field wiring and are only intended for connection to<br />
mating connectors of the internal wiring inside the end-use product. The acceptability of these and the<br />
mating connectors relative to secureness, insulation materials, and temperatures shall be considered.<br />
2262749 Report_2262749.doc\dw<br />
DQD 507.10 Rev. 2008-11-28
MASTER CONTRACT: 173688 (LR 38879C)<br />
REPORT: 2262749<br />
PROJECT: 2262749<br />
Page No: 3<br />
Date Issued: January 28, 2010<br />
4. A suitable Electrical, Fire and Mechanical enclosure shall be provided.<br />
5. All models were submitted and tested for a maximum manufacturer’s recommended ambient operating<br />
temperature of 110ºC for -8 models and 71ºC for -9 models, and 80ºC for 40KMX35MMTH-S1,<br />
40KMX35MMTH-S2 and 40KMX35MTTJ-S2 models. Consideration should be given to measure the<br />
temperatures on the unit when the converter is installed in the end-use equipment.<br />
6. The maximum working voltage present is 77 V rms, 150 V pk for Model 40IMX35D15D15-8Z, and<br />
83 V rms, 212 V pk for model 40KMX35MMTH-S1. The Electric Strength Tests in the end product shall<br />
be based on these values.<br />
7. The units were tested for an input voltage range per the tables in the Nomenclature and Electrical ratings<br />
section of this report with zero tolerance. If used outside these voltage ranges, additional testing may be<br />
required.<br />
8. Special enclosure consideration should be given to the end-use installation. Hazardous voltage is<br />
available on the surface of the PWB. The end-use product should be reviewed to determine whether<br />
accessibility requirements are met for the end-use product.<br />
9. Special spacing consideration should be given to the end-use product as the spacings between the unit and<br />
mounting surface have not been evaluated.<br />
10. Abnormal and Component Failure Tests on all models except 20IMX35 and 20KMX35 were conducted<br />
with the power supply input protected by certified fuse, rated F, 125 V dc, 5 A. If a fuse rated greater<br />
than 5 A is used, additional testing may be required.<br />
Component Failure test on models 20IMX35 and 20KMX35 were conducted with input protected by<br />
certified fuse, rated 125 V dc, 8 A. If a fuse rated greater than 8 A is used and not certified, additional<br />
testing may be required.<br />
11. For the purpose of applying insulation requirements, the input to this DC to DC converter is identified as<br />
TNV-2 or SELV, therefore, basic insulation based on 75 V dc input is provided between the input and<br />
output of the converter. An additional evaluation is needed if the source is other than TNV-2 or SELV.<br />
12. Model 40KMX35MTTJ-S2 has been evaluated for operational altitude of 4500 m. Per IEC60664-1: 1992<br />
Table A.2. Altitude Correction Factor is 1.4 for the higher Altitude and not intended for use in vehicles,<br />
on board ships or aircraft.<br />
MARKINGS<br />
Marking Method:<br />
- CSA accepted and UL recognized adhesive nameplate, suitable for the surface to which it is applied.<br />
Marking consists of Company Name and Series identification etched in PWB trace patterns.<br />
- Due to insufficient surface to which a CSA Mark can be applied after all other necessary markings have<br />
been applied (i.e. free, markable surface less than 1 cm 2 ), the CSA Mark may be applied to the smallest<br />
unit of packaging containing the certified product.<br />
Note: Refer to the Design Manual for other marking option.<br />
2262749 Report_2262749.doc\dw<br />
DQD 507.10 Rev. 2008-11-28
Declaration of Conformity<br />
CE MARKING<br />
We, <strong>Power</strong>-<strong>One</strong>, Inc.,740 Calle Plano, Camarillo, CA. 93012 USA<br />
declare under our sole responsibility that the products;<br />
<strong>Power</strong> Supply Model:<br />
IMX35, KMX35 Series<br />
to which this declaration relates, is/are in compliance with the following document(s):<br />
Quality Standard(s): ISO 9001, EN 29001<br />
Directive:<br />
DIR 2006/95/EC, Low Voltage Directive<br />
Product Safety Standard(s): EN 60950-1: 2006<br />
IEC 60950-1: 2005<br />
(Licensed by a Notified Body to the European Union )<br />
These component level power supplies are intended exclusively for inclusion within other<br />
equipment by an industrial assembly operation or by professional installers per the<br />
Installation Instructions provided with the power supplies.<br />
Camarillo, Ca. June 29, 2010<br />
(Manufacturer) (Place) (Date)<br />
Robert P. White Jr.<br />
Director of Safety and<br />
Environmental Compliance