09.04.2014 Views

Socket relays.pdf

Socket relays.pdf

Socket relays.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3<br />

MRC series<br />

C3-X1x<br />

11-pin power relay, 1-pole, double make, according to IEC 67-I-18a<br />

Type<br />

C3-X1x/ ... V<br />

Power <strong>relays</strong> for DC application<br />

1 pole, NO, double make<br />

Maximum contact load 10 A/250 V AC 1 7 A/110 V DC1<br />

10 A/30 V DC 1 1,2 A/220 V DC1<br />

Contacts<br />

Material Standard Code 0 AgNi<br />

Rated current<br />

10 A<br />

Switch-on current max. (20 ms)<br />

30 A<br />

Switching voltage max.<br />

250 V<br />

AC load (Fig 1)<br />

2,5 kVA<br />

DC load see Fig. 2<br />

Coil<br />

Coil resistance see table; tolerance ± 10 %<br />

Pick-up voltage<br />

≤ 0,8 x U N<br />

Release voltage<br />

≥ 0,1 x U N<br />

Nominal power<br />

2,4 VA (AC)/1,3 W (DC)<br />

4<br />

1<br />

3<br />

8<br />

11<br />

9<br />

Connection diagram<br />

Gap:<br />

><br />

2<br />

3 mm<br />

6<br />

(1,7 + 1,7)<br />

A1 A3<br />

ON (+) OFF (+)<br />

A2 (-)<br />

10<br />

Fig. 1<br />

DC1 110V<br />

3 9<br />

DC1 220V<br />

2<br />

A1(+)<br />

AC voltage endurance<br />

A2<br />

10<br />

3<br />

Imán<br />

Coil table VAC Ω mA VDC Ω mA<br />

24 65 100 24 443 54<br />

48 286 50 48 1K7 27<br />

115 1K7 21 110 9K2 12<br />

230 6K8 10 220 36K1 6<br />

Insulation<br />

Contact open<br />

Contact/contact<br />

Contact/coil<br />

Insulation resistance at 500 V<br />

Insulation, IEC 61810-1<br />

Volt rms, 1 min<br />

2500 V<br />

2,5 kV<br />

2,5 kV<br />

≥1 GΩ<br />

2,5 kV/3<br />

Specifications<br />

Ambient temperature operation/storage -40 (no ice).…60 ºC /-40 ... 80 °C<br />

Pick-up time/bounce time<br />

20 ms/≤ 3 ms<br />

Release time/bounce time<br />

10 ms/≤ 1 ms<br />

Mechanical life ops<br />

AC: 10 Mill./DC: 20 Mill.<br />

DC voltage endurance at rated load<br />

≥ 100000 switching cycles<br />

Switching frequency at rated load<br />

≤ 1200/ops/h<br />

Protection class<br />

IP40<br />

Weight<br />

90 g<br />

Standard types<br />

VAC 50 Hz/60 Hz: 24, 48, 115 (120), 230 (240)<br />

LED<br />

RC Suppresor<br />

C3-X10/AC ... V<br />

C3-X10X/AC ... V<br />

C3-X10R/AC ... V<br />

10<br />

switching cycles x10 6<br />

1<br />

0,1<br />

kVA 0,5 1 1,5 2 2,5<br />

Amps.<br />

Fig. 2 DC load limit curve<br />

10<br />

1<br />

Dimensions [mm]<br />

AC1<br />

AC1<br />

Cos ϕ AC15 0,4<br />

DC13 110V<br />

DC13 220V<br />

DC1<br />

L/R 40 ms<br />

0,1<br />

Volt 25 75 125 175 225<br />

A2<br />

10<br />

11<br />

1<br />

2<br />

A1<br />

VDC 24, 48, 110, 220<br />

LED<br />

Free wheeling diode<br />

Polarity and free wheeling diode<br />

C3-X10/DC ... V<br />

C3-X10X/DC ... V<br />

C3-X10DX/DC ... V<br />

C3-X10FX/DC ... V<br />

58.5<br />

66<br />

35<br />

9<br />

8<br />

7<br />

6<br />

35<br />

5<br />

4<br />

AC/DC bridge rectifier 24 V, 48 V, 60 V<br />

C3-X10BX/UC ... V<br />

"..." Enter the voltage for full type designation<br />

Accessories<br />

<strong>Socket</strong>:<br />

Optional accessories (blanking plug):<br />

S3-B, S3-S, S3-L, S3-P, S3-P0, S3-MP, S3-MS<br />

SO-NP, SO-OP<br />

Technical approvals, conformities<br />

IEC 61810; EN 60947<br />

20 | 0410 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.