09.04.2014 Views

Socket relays.pdf

Socket relays.pdf

Socket relays.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

QRC series<br />

C7-W1x<br />

4-pin, miniature relay, 1-pole, tungsten contact, faston<br />

Type:<br />

C7-W1x/ ... V<br />

Power relay for high inrush current<br />

1 pole normally open<br />

Maximum contact load: 10 A/250 V AC 6 A/250 V AC5a/b<br />

Recommended minimum contact load: 10 mA/10 V<br />

Contacts<br />

Material Standard Code 0 AgNi/W<br />

Rated current<br />

10 A<br />

Switch-on current max. (2,5 ms)<br />

500 A<br />

Switching voltage max.<br />

250 V<br />

AC load (Fig 1)<br />

2,5 kVA<br />

DC load see fig. 2<br />

Connection diagram<br />

4<br />

7<br />

A1(+)<br />

3 4 7<br />

A1(+<br />

DC1<br />

Coil<br />

Coil resistance see table; tolerance ± 10 %<br />

Pick-up voltage<br />

≤ 0,8 x U N<br />

Release voltage<br />

≥ 0,1 x U N<br />

Nominal power<br />

1,5 VA (AC)/1,5 W (DC)<br />

Coil table VAC Ω mA VDC Ω mA<br />

24 153 62 12 99 121<br />

48 611 31 24 388 61<br />

115 3K6 13 48 1K5 32<br />

230 14K5 6,5 110 8K 14<br />

Insulation<br />

Contact open<br />

Contact/coil<br />

Insulation resistance at 500 V<br />

Insulation, IEC 61810-1<br />

Volt rms, 1 min<br />

1000 V<br />

2,5 kV<br />

≥1 GΩ<br />

2,5 kV<br />

Specifications<br />

Ambient temperature operation/storage -40 (no ice).…60 ºC /-40 ... 80 °C<br />

Pick-up time/bounce time<br />

20 ms/≤ 3 ms<br />

Release time/bounce time<br />

10 ms/≤ 1 ms<br />

Mechanical life ops<br />

AC: 10 Mill./DC: 20 Mill.<br />

DC voltage endurance at rated load<br />

≥ 100000 switching cycles<br />

Switching frequency at rated load ≤ 1200/h<br />

Protection class<br />

IP40<br />

Weight<br />

43 g<br />

Standard types<br />

VAC 50 Hz/60 Hz: 24, 48, 115 (120), 230 (240)<br />

LED<br />

C7-W10/AC ... V<br />

C7-W10X/AC ... V<br />

switching cycles x10 6<br />

10<br />

Operations x10 6<br />

Fig. 1<br />

10<br />

1<br />

1<br />

5<br />

A2<br />

8<br />

AC voltage endurance<br />

ACI<br />

AC1<br />

Cos ϕ AC15 0,4<br />

0,1<br />

kVA 0,5 1 1,5 2 2,5<br />

Fig. 2<br />

AC voltage endurance<br />

AC5 AC5 a/b a/b<br />

0,1<br />

VA 250 500 750 1000<br />

Dimensions [mm]<br />

DC1<br />

DC13<br />

A2<br />

8<br />

VDC 12, 24, 48, 110<br />

LED<br />

Free wheeling diode<br />

Polarity and free wheeling diode<br />

AC/DC bridge rectifier 24 V, 48 V, 60 V<br />

"..." Enter the voltage for full type designation<br />

Accessories<br />

<strong>Socket</strong>:<br />

Optional accessories (blanking plug):<br />

C7-W10/DC ... V<br />

C7-W10X/DC ... V<br />

C7-W10DX/DC ... V<br />

C7-W10FX/DC ... V<br />

C7-W10BX/UC ... V<br />

S7-M, S7-I/O, S7-L, S7-P, S7-P0<br />

S9-NP, S9-OP<br />

4.75 4.75<br />

4.70 4.70<br />

FASTON .187 FASTON .187<br />

5.90<br />

Technical approvals, conformities<br />

2<br />

C.I.<br />

37.5<br />

37.5<br />

2<br />

C.I. Lloyd´s<br />

IEC 61810; EN 60947<br />

28<br />

4.05<br />

7.25<br />

6.10<br />

1<br />

3<br />

5<br />

28<br />

7<br />

A<br />

RELECO<br />

21<br />

10<br />

4.05<br />

1<br />

3<br />

5<br />

21<br />

10<br />

5.90<br />

DC1<br />

7.25<br />

DC13<br />

ø2.2 ø2.2<br />

6.10<br />

14.5<br />

2<br />

4<br />

6<br />

8<br />

B<br />

14.5<br />

2<br />

4<br />

6<br />

7 8<br />

A B<br />

RELECO<br />

44 | 0410 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!