Socket relays.pdf
Socket relays.pdf
Socket relays.pdf
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
3<br />
MRC series<br />
C3-S1x<br />
11-pin standard <strong>relays</strong>, sensitive, 1-pole, according to IEC 67-I-18a<br />
Type<br />
C3-S1x/ DC... V<br />
Sensitive <strong>relays</strong>, 250 mW,<br />
1 change-over contacts<br />
Operating range<br />
0,8 … 2,5 x Un<br />
Maximum contact load 6 A/250 V AC1 6 A/30 V DC1<br />
Recommended minimum contact load 10 mA/10 V Code 4<br />
5 mA/5 V Code 8<br />
4 3<br />
12 14<br />
11<br />
1<br />
4 3<br />
5 7 8 9<br />
22 24 32 34<br />
21<br />
6<br />
8<br />
9<br />
31<br />
11<br />
2<br />
A1(+)<br />
2<br />
A1(+)<br />
A2<br />
10<br />
Contacts<br />
Material Standard, Code 4 AgNi + 0,2 µ Au<br />
Optional, Code 8 AgNi + 10 µ Au<br />
Rated current<br />
6 A<br />
Switch-on current max. (20 ms)<br />
15 A<br />
Switching voltage max.<br />
250 V<br />
AC load (Fig 1)<br />
1,5 kVA<br />
DC load see Fig. 2<br />
1<br />
11<br />
Connection diagram<br />
5<br />
7<br />
2<br />
A1(+)<br />
10<br />
Coil<br />
Coil resistance see table; tolerance ± 10 %<br />
Pick-up voltage<br />
≤ 0,8 x U N<br />
Release voltage<br />
≥ 0,1 x U N<br />
Nominal power<br />
250 mW<br />
Fig. 1<br />
10<br />
6<br />
A2<br />
10<br />
AC voltage endurance<br />
Coil table VDC Ω mA<br />
6 140 43<br />
12 536 22<br />
24 2164 11<br />
48 8651 5,5<br />
Insulation<br />
Contact open<br />
Contact/contact<br />
Contact/coil<br />
Insulation resistance at 500 V<br />
Insulation, IEC 61810-1<br />
Volt rms, 1 min<br />
1000 V<br />
2,5 kV<br />
2,5 kV<br />
≥1 GΩ<br />
2,5 kV/3<br />
Specifications<br />
Ambient temperature operation/storage -40 (no ice).…60 ºC /-40 ... 80 °C<br />
Pick-up time/bounce time<br />
18 ms/≤ 3 ms<br />
Release time/bounce time<br />
10 ms/≤ 1 ms<br />
Mechanical life ops<br />
DC: 20 Mill.<br />
DC voltage endurance at rated load<br />
≥ 100000 switching cycles<br />
Switching frequency at rated load<br />
≤ 1200/ops/h<br />
Protection class<br />
IP40<br />
Weight<br />
73 g<br />
Standard types<br />
switching cycles x10 6<br />
AC1 AC1<br />
1<br />
0,1<br />
kVA 0,5 1 1,5<br />
Fig. 2 DC load limit curve<br />
10<br />
1<br />
1Amps.<br />
AC1<br />
DC1<br />
DC1 DC1<br />
0,1<br />
Volt 50 100 150 200<br />
Dimensions [mm]<br />
VDC 12, 24, 48 C3-S14/DC ... V C3-S18/DC ... V<br />
Free wheeling diode C3-S14D/DC ... V C3-S18D/DC ... V<br />
Polarity and free wheeling diode C3-S14F/DC ... V C3-S18F/DC ... V<br />
35<br />
A2<br />
9<br />
A1<br />
Connection of diodes to the coil will increase the release time.<br />
LED available upon request.<br />
58.5<br />
8<br />
10<br />
11<br />
1<br />
2<br />
66<br />
7<br />
6<br />
35<br />
5<br />
4<br />
"..." Enter the voltage for full type designation<br />
Accessories<br />
<strong>Socket</strong>:<br />
Optional accessories (blanking plug):<br />
S3-B, S3-S, S3-L, S3-P, S3-P0, S3-MP, S3-MS<br />
SO-NP, SO-OP<br />
Technical approvals, conformities<br />
IEC 61810; EN 60947<br />
22 | 0410 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.