09.04.2014 Views

Socket relays.pdf

Socket relays.pdf

Socket relays.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3<br />

MRC series<br />

C3-N3x<br />

11-pin standard <strong>relays</strong>, sensitive, 3-pole, according to IEC 67-I-18a<br />

Type<br />

C3-N3x/DC ... V<br />

Sensitive <strong>relays</strong>, 800 mw<br />

3 change-over contacts<br />

Operating range<br />

0,8 ... 1,4 x Un<br />

Maximum contact load 6 A/250 V AC 1 6 A/30 V DC1<br />

Recommended minimum contact load 10 mA/10 V Code 4<br />

5 mA/ 5 V Code 8<br />

Contacts<br />

Material Standard Code 4 AgNi + 0,2 µ Au<br />

Optional Code 8 AgNi + 10 µ Au<br />

Rated current<br />

6 A<br />

Switch-on current max. (20 ms)<br />

15 A<br />

Switching voltage max.<br />

250 V<br />

AC load (Fig 1)<br />

1,5 kVA<br />

DC load see Fig. 2<br />

Coil<br />

Coil resistance see table; tolerance ± 10 %<br />

Pick-up voltage<br />

≤ 0,8 x U N<br />

Release voltage<br />

≥ 0,1 x U N<br />

Nominal power<br />

800 mW<br />

Coil table VDC Ω mA<br />

24 720 33<br />

48 2K8 17<br />

60 4K5 13<br />

110 15K 7<br />

Insulation<br />

Contact open<br />

Contact/contact<br />

Contact/coil<br />

Insulation resistance at 500 V<br />

Insulation, IEC 61810-5<br />

Volt rms, 1 min<br />

1000 V<br />

2,5 kV<br />

2,5 kV<br />

≥1 GΩ<br />

2,5 kV/3<br />

Specifications<br />

Ambient temperature operation/storage -40 (no ice).…60 ºC /-40 ... 80 °C<br />

Pick-up time/bounce time<br />

18 ms/≤ 3 ms<br />

Release time/bounce time<br />

10 ms/≤ 1 ms<br />

Mechanical life ops<br />

DC: 20 Mill.<br />

DC voltage endurance at rated load<br />

≥ 100000 switching cycles<br />

Switching frequency at rated load<br />

≤ 1200/ops/h<br />

Protection class<br />

IP40<br />

Weight<br />

90 g<br />

Connection diagram<br />

Fig. 1<br />

10<br />

switching cycles x10 6<br />

1<br />

4 3<br />

12 14<br />

11<br />

1<br />

4<br />

1<br />

3<br />

5 7 8 9<br />

22 24 32 34<br />

21<br />

6<br />

8<br />

11<br />

9<br />

31<br />

11<br />

2<br />

A1(+)<br />

10<br />

2<br />

A1(+)<br />

A2<br />

10<br />

AC1<br />

5 7 2<br />

A1(+)<br />

0,1<br />

kVA 0,5 1 1,5<br />

A2<br />

Fig. 2 DC load<br />

6<br />

limit<br />

10<br />

curve<br />

DC1<br />

10<br />

1<br />

Amps.<br />

AC voltage endurance<br />

DC1 DC1<br />

0,1<br />

Volt 50 100 150 200<br />

Dimensions [mm]<br />

AC1 AC1<br />

Standard types<br />

VDC 24, 48, 60, 110 C3-N34/DC ... V C3-N38/DC ... V<br />

Free wheeling diode C3-N34D/DC ... V C3-N38D/DC ... V<br />

Polarity and free wheeling diode C3-N34F/DC ... V C3-N38F/DC ... V<br />

58.5<br />

66<br />

35<br />

A2<br />

9<br />

8<br />

10<br />

7<br />

11<br />

6<br />

1<br />

5<br />

2<br />

4<br />

A1<br />

Connection of diodes to the coil will increase the release time.<br />

LED available upon request.<br />

35<br />

"..." Enter the voltage for full type designation<br />

Accessories<br />

<strong>Socket</strong>:<br />

Optional accessories (blanking plug):<br />

S3-B, S3-S, S3-L, S3-P, S3-P0, S3-MP, S3-MS<br />

SO-NP, SO-OP<br />

Technical approvals, conformities<br />

IEC 61810; EN 60947<br />

24 | 0410 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!