As a true online double conversion UPS the Centurion RT is<br />
our highest density UPS. Boasting an output power factor<br />
of 0.9, this will fully protect mission critical devices as it can<br />
support larger loads than UPS products of an equal VA<br />
rating.<br />
The Centurion RT has an energy saving ECO mode, which<br />
allows the unit to operate at very high efficiency, up to<br />
98%. When the utility mains input voltage is within the ECO<br />
range the UPS saves energy by passing the mains supply<br />
directly through to the load, using the inverter<br />
intermittently.<br />
The Centurion RT incorporates hot-swappable internal<br />
battery packs which can be accessed via the front panel<br />
for maintenance changes, keeping the UPS operational<br />
during battery replacement. Battery backup time can be<br />
increased by simply adding additional Battery Banks.<br />
The LCD display panel is readily viewable whether the UPS<br />
is horizontal or vertical. The display Menu is simple and<br />
intuitive. It displays all critical and noncritical parameters,<br />
including the estimated battery backup time remaining.<br />
This UPS comes with programmable power management<br />
outlets allowing the user to control load segments,<br />
therefore extending battery backup times to mission<br />
critical devices by shutting down noncritical items.<br />
Centurion RT<br />
<strong>features</strong><br />
• True double-conversion<br />
• Output power factor 0.9<br />
• User-friendly and easy-shift LCD display<br />
• Rack or Tower design<br />
• ECO and advanced ECO mode for energy saving<br />
• Output voltage regulation ± 1%<br />
• Generator compatible<br />
• Programmable power management outlets<br />
• Emergency Power Off function (EPO)<br />
• Hot swappable battery design<br />
• Available in 1000, 2000 and 3000 VA models<br />
• Ideal for medium density power protection<br />
• USB, RS232, SNMP and AS400 multiple communications<br />
available<br />
The Centurion RT addresses the real market need of our<br />
clients: to develop True Online Double Conversion UPS<br />
products that can be used interchangeably in either tower<br />
or rackmount form factors, has ECO mode capability, with<br />
extendable battery backup times that can be easily<br />
increased, programmable outlets<br />
and with a front panel LCD that displays<br />
crucial information to the user.<br />
THE AUSTRALIAN UPS COMPANY<br />
www.powershield.com.au
Centurion RT<br />
BATTERY BANKS<br />
Model LSCERT1000S PSCERT2000S PSCERT3000 PSCRTBB8<br />
PSCRTBB12<br />
Capacity VA 1000 VA 2000 VA 3000 VA<br />
Suits PSCERT2000S<br />
Suits PSCERT3000<br />
W 900 W 1800 W 2700 W<br />
INPUT<br />
Voltage<br />
Range<br />
Low Line Transfer 160 Vac / 140 Vac / 120 Vac / 110 Vac ± 5 %<br />
(based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0)<br />
Low Line Comeback 170 Vac / 150 Vac / 130 Vac / 120 Vac ± 5 %<br />
High Line Transfer 300 Vac ± 5 %<br />
High Line Comeback 290 Vac ± 5 %<br />
Frequency Range<br />
40Hz - 70Hz<br />
Phase<br />
Single phase with ground<br />
Power Factor Correction 0.99 @ nominal voltage (100% load)<br />
OUTPUT<br />
Power Factor<br />
0.9<br />
Output Voltage<br />
AC Voltage Regulation (Batt. Mode)<br />
Frequency Range (Synchronized Range)<br />
Frequency Range (Batt. Mode)<br />
Load Crest Factor<br />
240Vac (User selectable 208/220/230/240 Vac)<br />
± 1%<br />
47 - 53 Hz or 57 - 63 Hz<br />
50 Hz ±0.5 % or 60Hz ± 0.5%<br />
5:1 (max.)<br />
Harmonic Distortion 2 % THD (Linear Load) ; 8% THD max. (Non Linear Load) (Batt. mode before shut down)<br />
Transfer Line mode to battery mode<br />
Zero<br />
Time Inverter to Bypass<br />
4 ms (Typical)<br />
Waveform (Batt. Mode)<br />
Pure Sinewave<br />
EFFICIENCY<br />
AC Mode 88% 90%<br />
Battery Mode 86% 88%<br />
Battery<br />
Battery Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9Ah 12 V / 9 Ah<br />
Numbers 2 4 6 8 12<br />
Typical Recharge Time<br />
4 hours recover to 90% capacity (for standard model only)<br />
Charging Current (max.) 1A 1A 1A<br />
Charging Voltage 27.4 Vdc ± 1% 54.7 Vdc ±1% 82.1 Vdc ±1%<br />
INDICATORS<br />
LCD Display<br />
UPS status, Load level, Battery level, Input/Output Voltage,<br />
Battery Time Remaining and Fault indicators<br />
ALARM<br />
Battery Mode<br />
2 beeps every 30 seconds<br />
Bypass Mode<br />
1 beep every 10 seconds<br />
Low Battery<br />
Rapid one beep every second<br />
Overload<br />
2 short beeps every 2 seconds<br />
Fault<br />
Continously sounding<br />
PHYSICAL<br />
Dimension, D x W x H (mm) 380 x 438 x 88 480 x 438 x 88 600 x 438 x 88<br />
Net Weight (kgs) 12.9 20.6 28<br />
ENVIRONMENT<br />
Humidity<br />
20-90 % RH @ 0-40°C (non-condensing)<br />
Noise Level<br />
Less than 50dBA @ 1 Meter<br />
MANAGEMENT<br />
Smart RS232<br />
USB<br />
Optional PSSNMP<br />
Optional PSAS400<br />
PowerShield NetGuard Software - Supports Windows ® 2000/2003/XP/Vista/2008,<br />
Windows ® 7, Linux, Unix, and MAC<br />
Power management from SNMP manager and web browser (Intelligent Slot)<br />
AS400 dry contact communication card (Intelligent Slot)<br />
PSCERT1000S<br />
PSCERT2000S PSCERT3000<br />
PSCRTBB8<br />
Suits PSCERT2000S<br />
PSCRTBB12<br />
Suits PSCERT3000<br />
* Product specifications are subject to change without further notice<br />
www.powershield.com.au