11.04.2014 Views

Advance Terminal Planning Study Program Criteria Document

Advance Terminal Planning Study Program Criteria Document

Advance Terminal Planning Study Program Criteria Document

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

KANSAS CITY INTERNATIONAL AIRPORT PROGRAM CRITERIA DOCUMENT<br />

ADVANCE TERMINAL PLANNING STUDY DRAFT<br />

Landrum & Brown Page 43<br />

April 2013<br />

Table 3.2-1 (continued)<br />

EXISTING FACILITY INVENTORY AND FUTURE TERMINAL REQUIREMENTS<br />

MCI Airport<br />

<strong>Terminal</strong> <strong>Program</strong><br />

Public Space<br />

Units<br />

2012 Existing<br />

Facilities<br />

2025<br />

Recommended<br />

Facilities<br />

2030<br />

Recommended<br />

Facilities<br />

Security Screening Checkpoint (SSCP)<br />

Number of Lanes pos 23 14 16<br />

Queuing Area sf 2,573 6,300 7,600<br />

Checkpoint Screening Area sf 24,364 24,000 27,100<br />

TSA Offices sf 5,463 3,000 3,500<br />

SubTotal: 32,400 33,300 38,200<br />

Circulation<br />

Ticket Lobby Circulation sf - 8,800 9,500<br />

Baggage Claim Circulation sf - 8,500 8,500<br />

Secure Circulation (Incl. Fire/Service Stairs to Apron) sf - 96,700 107,500<br />

General Public Circulation (Includes Vestibules, Vert Circ, Corridors) sf 174,378 64,300 69,900<br />

Public Seating sf 16,129 2,000 2,200<br />

Domestic Meeter/Greeter Lobby sf 7,000 10,000 10,900<br />

Transportation (Shuttle Service) & Hotel Courtesy Phones sf 1,144 700 700<br />

SubTotal: 198,651 191,000 209,200<br />

Restrooms<br />

Public Restrooms - Secure sf 5,040 5,600 7,000<br />

Public Restrooms - Non-Secure sf 17,977 10,900 12,000<br />

SubTotal: 23,017 16,500 19,000<br />

Other Space<br />

Misc Tenant<br />

American Credit Union (AAFCU), Central Carts, Chapel, USO, USPS sf 8,900 8,900<br />

Smoking Lounge sf 1,500 1,500<br />

Other (Displays, Information Counters, Visitors Commission etc) sf 702 700 700<br />

SubTotal: 702 11,100 11,100<br />

DRAFT<br />

Non-Public Space<br />

Non-Airline Tenant Space<br />

Airport Administration<br />

Offices/Support (City) sf 29,326 5,100 5,100<br />

Airport Police (Includes Locker Facilities) sf 413 2,000 2,000<br />

Other Tenants<br />

Misc Tenant sf 3,093 6,600 6,600<br />

SubTotal: 32,832 13,700 13,700<br />

Other Space<br />

Non-Public Restrooms / Lockers sf 22,197 2,700 3,000<br />

Non-Public Circulation sf 92,993 27,100 29,900<br />

Other sf 2,642 - -<br />

SubTotal: 117,832 29,800 32,900<br />

<strong>Terminal</strong> Function<br />

Maintenance/Janitorial/Storage/Shops sf 16,826 7,500 8,500<br />

Mechanical/Electrical/Telephone/Plumbing sf 101,710 91,900 103,300<br />

Building Systems (Structure/Non-net/Void) sf 23,533 21,800 24,600<br />

Exterior - Other (ie Public Gardens, etc) sf - - -<br />

SubTotal: 142,069 121,200 136,400