<strong>VS511SZ</strong> Tech Sheet<br />

<strong>Balboa</strong> Instruments<br />

System PN <strong>55053</strong>-<strong>03</strong><br />

System Model # <strong>VSP</strong>-<strong>VS511SZ</strong>-<strong>DCAJ</strong><br />

Software Version # 43<br />

EPN # 2765<br />

Base PCBA - PN 54385-<strong>03</strong><br />

PCB VS500Z - PN 22972 Rev D<br />

Base Panels<br />

VL600S – PN 54548<br />

VL700S – PN 54716<br />

VL701S (Serial Standard) – PN 51247-01<br />

Template used: 40600_P.pdf 01/07/2008<br />

<strong>55053</strong>-<strong>03</strong>_97_A.pdf 04/08/2008<br />

Page 1<br />

<strong>55053</strong>-<strong>03</strong>_97_A


System Revision History<br />

System PN EPN Date Requested By Changes Made<br />

<strong>55053</strong>-01 1801 05.29.2007 <strong>Balboa</strong> New system<br />

<strong>55053</strong>-02 2669 12.07.2007 <strong>Balboa</strong> Software update to v41<br />

<strong>55053</strong>-<strong>03</strong> 2765 04.08.2008 <strong>Balboa</strong> Software update to v43<br />

Page 2<br />

<strong>55053</strong>-<strong>03</strong>_97_A


Basic System Features and Functions<br />

Power Requirements<br />

<br />

<br />

System Outputs<br />

Setup 1 (As Manufactured)<br />

<br />

<br />

<br />

<br />

(Stereo)<br />

<br />

Optional Devices<br />

<br />

<br />

<br />

Additional Options<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

K8<br />

J2<br />

J1<br />

W2<br />

W3<br />

J1A<br />

J2A<br />

U4<br />

1<br />

K5<br />

2 3<br />

J12<br />

J10<br />

FUSE<br />

J18<br />

J13<br />

J60<br />

J22<br />

J7<br />

J8<br />

J44<br />

BALBOA INSTRUMENTS, INC.<br />

VS500Z<br />

P/N 22972 REV D<br />

2-SPD<br />

EXT RLY<br />

EXT.<br />

RLY<br />

AUX. F<br />

SEN. A<br />

SEN. B<br />

VAC<br />

MADE IN U.S.A<br />

COPYRIGHT 2005<br />

Page 3<br />

<strong>55053</strong>-<strong>03</strong>_97_A


C<br />

G<br />

Basic System Features and Functions<br />

Any time you change a DIP Switch, other than A1, you must reset Persistent<br />

Memory for your new DIP Switch Settings changes to take effect. If you do<br />

not reset Persistent Memory, your system may function improperly.<br />

To reset Persistent Memory:<br />

Power down by disconnecting power source from spa.<br />

Put a jumper across J43, covering both pins. (See illustration below)<br />

Power up by connecting power source to spa.<br />

Wait until “ ” is displayed on your panel.<br />

Power down again.<br />

Remove jumper from J43 (May also move to cover 1 pin only)<br />

Power up again.<br />

About Persistent Memory and Time of Day Retention:<br />

This system uses memory that doesn’t require a battery to store a variety of<br />

settings. What we refer to as Persistent Memory stores the filter settings,<br />

the set temperature, and the heat mode.<br />

Persistent Memory is not used for Time of Day. Only models with a<br />

Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the<br />

time. However, during power loss to the spa, the system will lose the<br />

correct time, and reset to 12:00 PM when power is restored.<br />

Power Up Display Sequence<br />

Upon power up, you should see the following on the display:<br />

Three numbers in a row, which are the SSID (the System Software<br />

ID). The third display of these numbers is the Software Version,<br />

which should match the version of your system. For example, if these<br />

three numbers are , that is a <strong>VS511SZ</strong> at version 38.<br />

Displayed next is: “ ” (indicating the system is configured for<br />

a heater between 3 and 6 kW) or “ ” (indicating the system is<br />

configured for a heater effectively* between 1 and 3 kW).<br />

“ ” should appear for all VS models running at 240VAC.<br />

“ ” should appear for all VS models running at 120VAC, as well<br />

as all GS models. (*A heater which is rated at 4 kW at 240VAC will<br />

function as a 1 kW heater at 120VAC.)<br />

“ ” will appear to signal the start of Priming Mode.<br />

At this point, the power up sequence is complete. Refer to the Reference<br />

Card for the VS or GS System model of your spa for information about how<br />

the spa operates from this point on, including how to adjust the Time of<br />

Day if using a Serial Deluxe style panel.<br />

J43<br />

E.GND<br />

K6<br />

G C<br />

F4 FUSE .3A 250V<br />

J23<br />

K1<br />

W1<br />

SWITCHBANK<br />

T1A<br />

K3<br />

K2<br />

F2<br />

W4<br />

E.GND<br />

J50<br />

G C<br />

J6<br />

G C<br />

SWITCHBANK A<br />

F7<br />

J17/26<br />

S1 TST<br />

FUSE 20A 250V<br />

W7<br />

K8<br />

K9<br />

J43<br />

J2<br />

J1<br />

J46<br />

J60 J22<br />

J6 J7 J8<br />

S1 TST<br />

EXT.<br />

AUX. F<br />

RLY<br />

SEN. A SEN. B<br />

J47<br />

G C<br />

W2<br />

W3<br />

J1A<br />

J2A<br />

J29<br />

G C<br />

K5<br />

1 2 3<br />

U4 J12<br />

J20<br />

F1<br />

J10<br />

FUSE 3A 250V<br />

J18<br />

J13<br />

BALBOA INSTRUMENTS, INC. 2-SPD<br />

J44 VS500Z<br />

EXT RLY<br />

P/N 22972 REV D<br />

VAC<br />

MADE IN U.S.A<br />

COPYRIGHT 2005<br />

J43 on VS5xxZ and VS300 Series Main Board Shown.<br />

J43 on GS5xxZ Series is located in approximately the same position.<br />

J26<br />

J90<br />

J50<br />

LINE<br />

BLK AC<br />

W1<br />

K4<br />

K1<br />

VS100<br />

P/N 22964_B MADE IN U.S.A.<br />

© 2006<br />

PUMP<br />

T0.25A 250V<br />

<strong>Balboa</strong><br />

J58<br />

G C<br />

J23<br />

F2<br />

HEATER<br />

OZONE<br />

J29<br />

G C<br />

WHT AC<br />

K3<br />

J9<br />

K2<br />

K5<br />

SWITCHBANK A<br />

NEUTRAL<br />

J57<br />

TST RST<br />

J6 J43<br />

F4<br />

S1<br />

SWITCHBANK A<br />

TST RST<br />

J6 J43<br />

J43 on VS100/GS100 Series Main Board Shown.<br />

F5, F3A 250V<br />

J13 J12<br />

J7<br />

SEN. A<br />

J8<br />

SEN. B<br />

J18<br />

U4<br />

J20<br />

G C<br />

J1<br />

Page 4<br />

<strong>55053</strong>-<strong>03</strong>_97_A


Wiring Configuration and DIP Settings<br />

Setup 1 (As Manufactured)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

(Stereo)<br />

<br />

<br />

<br />

CLASS G FUSE 30A<br />

J66<br />

J65<br />

J11<br />

F5<br />

WHT AC<br />

J15 J16 J25 J63 J64<br />

NEUTRAL<br />

WHITE<br />

BLK AC<br />

J61<br />

K6<br />

J23<br />

F4 FUSE .3A 250V<br />

2-Spd P1<br />

G C<br />

J74<br />

W1<br />

J73<br />

PCBA Rev D & E only.<br />

Black jumper required.<br />

Do not remove.<br />

K1<br />

J50 W10<br />

W4<br />

T1<br />

Audio Visual<br />

G C<br />

X-2SP Con<br />

G C<br />

Ozone and Circ Pump must be same voltage.<br />

Do not remove Fuse F7 (20A)<br />

F7 FUSE 20A 250<br />

J47 J29<br />

J17/26<br />

W7<br />

K9<br />

K8<br />

J46<br />

Circ.Pump<br />

G C<br />

W2<br />

W3<br />

J1 J1A<br />

Ozone<br />

G C<br />

K5<br />

J20<br />

12V<br />

Light<br />

G C<br />

F1<br />

J10<br />

FUSE 3A 250V<br />

K4<br />

TORQUE<br />

RANGE<br />

FOR TB1:<br />

27-30 IN. LBS.<br />

HOT<br />

BLACK<br />

HOT<br />

RED<br />

TB1<br />

K3<br />

K2<br />

J2<br />

J2A<br />

VS5xxS mode<br />

2 3<br />

1<br />

U4 J12<br />

J18<br />

J32 J33 J34 J35<br />

J43<br />

<strong>Balboa</strong><br />

J100<br />

J36 J37<br />

RED AC<br />

HTR2<br />

J101<br />

HTR1<br />

F2<br />

E.GND<br />

SWITCHBANK A<br />

J60 J22<br />

J6 J7 J8<br />

S1 TST<br />

EXT.<br />

RLY<br />

AUX. F<br />

SEN. A SEN. B<br />

J44<br />

BALBOA INSTRUMENTS, INC.<br />

VS500Z<br />

P/N 22972 REV D<br />

VAC MADE IN U.S.A<br />

COPYRIGHT 2005<br />

2-SPD<br />

EXT RLY<br />

J13<br />

4.0 kW<br />

Heater rated @ 240V<br />

(Approx. 1kW @ 120V)<br />

K1<br />

J6<br />

R B W<br />

G<br />

J2<br />

J4<br />

J7<br />

R B W G<br />

2-Spd P2<br />

J5 W12<br />

WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.<br />

WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)<br />

SSID #<br />

100<br />

68<br />

43<br />

A1, Test Mode OFF<br />

A2, See Table 1<br />

A7, N/A<br />

A3, Off-board Pump disabled enabled<br />

J43<br />

A9, Non-Circ Mode<br />

A5, 2-speed P1<br />

Panel Button Assignments<br />

A10, See Table 1<br />

Panel Button Positions<br />

1=Mode<br />

5=Pump 1<br />

7 1 2<br />

2<br />

2=Temp Up 6=Unused 6=Pump 2<br />

3=Temp Down<br />

5 6 4<br />

3 1 3<br />

7=Unused<br />

4=Light<br />

5<br />

2<br />

6<br />

1<br />

4 3<br />

VS51x/VS5xxS/VS5xxD<br />

Compatible<br />

J12<br />

Page 5<br />

1 2 3<br />

Memory<br />

Reset<br />

4<br />

5<br />

7<br />

6<br />

Wiring Color Key<br />

120 Volt Connections<br />

240 Volt Connections<br />

Black AC Jumpers<br />

12 Volt Connections<br />

Relay Control Wires<br />

Board Connector Key<br />

1 Typically Line voltage<br />

2 Typically Line voltage for 2-speed pumps<br />

3 Neutral (Common)<br />

4 Ground<br />

Note flat sides in connector<br />

<strong>55053</strong>-<strong>03</strong>_97_A


DIP Switches and Jumpers Definitions<br />

SSID 100 68 43<br />

DIP Switch Key<br />

A1 Test Mode (normally OFF)<br />

A2+A10 Control amp draw requirements (See Table 1)<br />

A3 “ON” position: off-board pump enabled<br />

“OFF” position: off-board pump disabled<br />

A4 Aux Freeze (must be OFF)<br />

A5+A9 Pump 1 speeds and Circ Modes:<br />

A5 A9 Circ Mode Pump 1 Speed<br />

OFF OFF Non-circ 2-speed<br />

ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed<br />

OFF ON 24 hours with 3°F shut-off 1-speed<br />

ON ON 24 hours with 3°F shut-off 2-speed<br />

A6 “ON” position: 50Hz operation<br />

“OFF” position: 60Hz operation<br />

A7 N/A (must be OFF)<br />

A8 “ON” position: temperature is displayed in degrees Celsius<br />

“OFF” position: temperature is displayed in degrees Fahrenheit<br />

Base Model <strong>VS511SZ</strong><br />

Table 1<br />

A2<br />

# of Hi-Speed<br />

Pumps/Blower<br />

Before Heat Disabled<br />

A10<br />

OFF OFF 0<br />

ON OFF 1<br />

OFF ON 2<br />

ON ON 3<br />

Jumper Key<br />

J12 Factory set. DO NOT MOVE.<br />

Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software.<br />

Jumper must be on Pins 2 and 3 for VS50xZ software.<br />

J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory.<br />

Leave on 1 pin only to enable persistent memory feature.<br />

WARNING:<br />

Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.<br />

Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.<br />

Contact <strong>Balboa</strong> if you require additional configuration pages added to this tech sheet.<br />

Panel Button Positions<br />

Aux Panel Information<br />

7<br />

1 2<br />

2<br />

4<br />

7<br />

Supports 2-button aux panel<br />

5 6 4<br />

3<br />

1<br />

3<br />

5<br />

6<br />

VX20<br />

5<br />

6<br />

6<br />

5<br />

2<br />

4 3<br />

1<br />

Supports 4-button aux panel<br />

Panel Button Assignments<br />

VX40S<br />

5 6 7 4<br />

1=Mode<br />

2=Temp Up<br />

3=Temp Down<br />

4=Light<br />

5=Pump 1<br />

6=Pump 2 (when A3 is ON)<br />

7=Unused<br />

Page 6<br />

<strong>55053</strong>-<strong>03</strong>_97_A


W<br />

W<br />

Ozone Connections<br />

Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or<br />

240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover<br />

of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2<br />

connects to White AC.<br />

The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the<br />

required voltage.<br />

WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ<br />

pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage<br />

is selected.<br />

<strong>Balboa</strong> Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone<br />

generator is likely to be configured correctly, but should be compared to the illustration below.<br />

If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next<br />

to the green ground wire as described below.<br />

Note: A special tool is required to remove the pins from the connector body once they are snapped in place.<br />

Check with your <strong>Balboa</strong> Account Manager for information on purchasing a pin-removal tool.<br />

<strong>Balboa</strong> Ozone connector configuration for 120V 60Hz<br />

Line - Black conductor<br />

Use this slot for the leftover Red conductor<br />

Common - Install the White conductor here for 120V ozone<br />

Ground (Green) conductor<br />

B<br />

G<br />

<strong>Balboa</strong> Ozone connector configuration for 240V 60Hz<br />

Line - Black conductor<br />

Use this slot for the leftover White conductor<br />

Common - Install the Red conductor here for 240V ozone<br />

Ground (Green) conductor<br />

Flat sides of sockets as shown<br />

B<br />

G<br />

FUSE 20A 250V<br />

J46<br />

J47<br />

J29<br />

K8<br />

J1<br />

Circ.Pump<br />

G W B R<br />

W2<br />

W3<br />

J1A<br />

K5<br />

J20<br />

12V<br />

Light<br />

F1<br />

FUSE 3A 250V<br />

Line - Black conductor<br />

Use this slot for the leftover conductor<br />

Common - Red for 240V or White for 120V ozone (See W2 wire)<br />

Ground (Green) conductor<br />

W2 wire determines voltage<br />

J10<br />

Page 7<br />

<strong>55053</strong>-<strong>03</strong>_97_A


Serial Standard Panel Configurations<br />

Jets Jets 1<br />

Warm<br />

Blower Jets 2<br />

Mode<br />

Light<br />

Jets 1 Blower Jets 2 Light Heat<br />

Cool<br />

VL600S<br />

PN 54548 with Overlay PN 11774<br />

Connects to Main Board terminal J1 only*<br />

Not compatible with fully-equipped VS510SZ<br />

VS5<strong>03</strong>/504/514SZ, or VS520SZ.<br />

SETUP 1<br />

VL700S<br />

PN 54716 with Overlay PN 11756<br />

Connects to Main Board terminal J1 only*<br />

Mode<br />

Warm<br />

Heat<br />

Jets 1 Jets 2 Light<br />

Cool<br />

VL701S (Serial Standard)<br />

PN 51247-01 with Overlay PN 10402<br />

Connects to Main Board terminal J1 only*<br />

* Panels with back-lighting (bulbs installed) should never be plugged into J2. Use J1 only.<br />