55053-03, VSP-VS511SZ-DCAJ - Balboa Direct
55053-03, VSP-VS511SZ-DCAJ - Balboa Direct
55053-03, VSP-VS511SZ-DCAJ - Balboa Direct
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Wiring Configuration and DIP Settings<br />
Setup 1 (As Manufactured)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
(Stereo)<br />
<br />
<br />
<br />
CLASS G FUSE 30A<br />
J66<br />
J65<br />
J11<br />
F5<br />
WHT AC<br />
J15 J16 J25 J63 J64<br />
NEUTRAL<br />
WHITE<br />
BLK AC<br />
J61<br />
K6<br />
J23<br />
F4 FUSE .3A 250V<br />
2-Spd P1<br />
G C<br />
J74<br />
W1<br />
J73<br />
PCBA Rev D & E only.<br />
Black jumper required.<br />
Do not remove.<br />
K1<br />
J50 W10<br />
W4<br />
T1<br />
Audio Visual<br />
G C<br />
X-2SP Con<br />
G C<br />
Ozone and Circ Pump must be same voltage.<br />
Do not remove Fuse F7 (20A)<br />
F7 FUSE 20A 250<br />
J47 J29<br />
J17/26<br />
W7<br />
K9<br />
K8<br />
J46<br />
Circ.Pump<br />
G C<br />
W2<br />
W3<br />
J1 J1A<br />
Ozone<br />
G C<br />
K5<br />
J20<br />
12V<br />
Light<br />
G C<br />
F1<br />
J10<br />
FUSE 3A 250V<br />
K4<br />
TORQUE<br />
RANGE<br />
FOR TB1:<br />
27-30 IN. LBS.<br />
HOT<br />
BLACK<br />
HOT<br />
RED<br />
TB1<br />
K3<br />
K2<br />
J2<br />
J2A<br />
VS5xxS mode<br />
2 3<br />
1<br />
U4 J12<br />
J18<br />
J32 J33 J34 J35<br />
J43<br />
<strong>Balboa</strong><br />
J100<br />
J36 J37<br />
RED AC<br />
HTR2<br />
J101<br />
HTR1<br />
F2<br />
E.GND<br />
SWITCHBANK A<br />
J60 J22<br />
J6 J7 J8<br />
S1 TST<br />
EXT.<br />
RLY<br />
AUX. F<br />
SEN. A SEN. B<br />
J44<br />
BALBOA INSTRUMENTS, INC.<br />
VS500Z<br />
P/N 22972 REV D<br />
VAC MADE IN U.S.A<br />
COPYRIGHT 2005<br />
2-SPD<br />
EXT RLY<br />
J13<br />
4.0 kW<br />
Heater rated @ 240V<br />
(Approx. 1kW @ 120V)<br />
K1<br />
J6<br />
R B W<br />
G<br />
J2<br />
J4<br />
J7<br />
R B W G<br />
2-Spd P2<br />
J5 W12<br />
WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.<br />
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)<br />
SSID #<br />
100<br />
68<br />
43<br />
A1, Test Mode OFF<br />
A2, See Table 1<br />
A7, N/A<br />
A3, Off-board Pump disabled enabled<br />
J43<br />
A9, Non-Circ Mode<br />
A5, 2-speed P1<br />
Panel Button Assignments<br />
A10, See Table 1<br />
Panel Button Positions<br />
1=Mode<br />
5=Pump 1<br />
7 1 2<br />
2<br />
2=Temp Up 6=Unused 6=Pump 2<br />
3=Temp Down<br />
5 6 4<br />
3 1 3<br />
7=Unused<br />
4=Light<br />
5<br />
2<br />
6<br />
1<br />
4 3<br />
VS51x/VS5xxS/VS5xxD<br />
Compatible<br />
J12<br />
Page 5<br />
1 2 3<br />
Memory<br />
Reset<br />
4<br />
5<br />
7<br />
6<br />
Wiring Color Key<br />
120 Volt Connections<br />
240 Volt Connections<br />
Black AC Jumpers<br />
12 Volt Connections<br />
Relay Control Wires<br />
Board Connector Key<br />
1 Typically Line voltage<br />
2 Typically Line voltage for 2-speed pumps<br />
3 Neutral (Common)<br />
4 Ground<br />
Note flat sides in connector<br />
<strong>55053</strong>-<strong>03</strong>_97_A