C. Wet Breathing:<br />

1. Improper clearing, or diver diving in total Instruct the diver on proper clearing<br />

head-down position.<br />

technique.<br />

2. Leaking past adjusting lever 25 . Install new o-ring 24 . Check sealing<br />

surface & groove.<br />

3. Diaphragm improperly installed or holed. Check position of diaphragm visually.<br />

Replace if holed.<br />

4. Damaged or loose fitting exhaust valve Replace exhaust valve 26 .<br />

5. Crack in case 20 . Replace case.<br />

D. High Frequency Humming or Buzzing During Inhalation:<br />

1. Harmonic resonance between the springs Disassemble the first stage and flip the<br />

and the mass of the piston in the first stage. main spring over. Change the position<br />

of the piston 23 in its bore. If<br />

resonance is still present, install a new<br />

piston and spring.<br />

E. Low Frequency Fluttering During Inhalation (Above the Surface Only):<br />

1. Harmonic resonance between the springs Try adjusting the lever tip closer or<br />

and the mass of the second stage diaphragm. farther from the diaphragm wear plate.<br />

Switch diaphragm with another unit.<br />

Explain to the customer that this is not<br />

harmful to the regulator, and does not<br />

happen underwater.<br />