C. Wet Breathing:<br />
1. Improper clearing, or diver diving in total Instruct the diver on proper clearing<br />
head-down position.<br />
technique.<br />
2. Leaking past adjusting lever 25 . Install new o-ring 24 . Check sealing<br />
surface & groove.<br />
3. Diaphragm improperly installed or holed. Check position of diaphragm visually.<br />
Replace if holed.<br />
4. Damaged or loose fitting exhaust valve Replace exhaust valve 26 .<br />
5. Crack in case 20 . Replace case.<br />
D. High Frequency Humming or Buzzing During Inhalation:<br />
1. Harmonic resonance between the springs Disassemble the first stage and flip the<br />
and the mass of the piston in the first stage. main spring over. Change the position<br />
of the piston 23 in its bore. If<br />
resonance is still present, install a new<br />
piston and spring.<br />
E. Low Frequency Fluttering During Inhalation (Above the Surface Only):<br />
1. Harmonic resonance between the springs Try adjusting the lever tip closer or<br />
and the mass of the second stage diaphragm. farther from the diaphragm wear plate.<br />
Switch diaphragm with another unit.<br />
Explain to the customer that this is not<br />
harmful to the regulator, and does not<br />
happen underwater.<br />
21