6<br />
Overview<br />
Modular components<br />
Field<strong>Power</strong> ® terminals or a mounting rail can be placed<br />
as needed in the lower section in order to fit the needs<br />
of the individual application. Retractable seals allow<br />
pluggable cables to be inserted quickly.<br />
Application specific solutions<br />
Weidmüller offers not only individual<br />
components but also complete, custom-fit<br />
functional units.<br />
IP 65 switched-mode power supply /<br />
Electrical cabinet socket outlet<br />
Add-on to lid<br />
Support pegs in the lid help when attaching mounting<br />
plates or rails. The lids also provide plenty of space for<br />
attaching add-on devices or electronic circuit boards.<br />
E<br />
Variable fastening mechanisms<br />
The mounting rail provides 54 mm of installation width<br />
<strong>and</strong> can be used at two heights. This creates space for<br />
wires under the mounting rail.<br />
Such units include switching devices,<br />
electronic components, terminal strips,<br />
connecting plugs, hinged lids <strong>and</strong> heat sinks.<br />
Weidmüller can also customise the internal<br />
wiring <strong>and</strong> the assembly of the connecting<br />
cables to fit customer needs.<br />
3∼, N, PE<br />
Exp<strong>and</strong>ed voltage <strong>and</strong> current ranges<br />
A variety of applications can be implemented with the<br />
help of the Field<strong>Power</strong> ® Terminals in the AC <strong>and</strong> DC<br />
versions up to 800 V/41 A.<br />
2 x DC, GND<br />
Pv zul [W]<br />
40,0<br />
35,0<br />
30,0<br />
for outer Tu 25 °C<br />
25,5 W<br />
25,0<br />
for outer Tu 35 °C<br />
20,0<br />
20,1 W 20,1 W<br />
for outer Tu 45 °C<br />
15,0<br />
14,8 W 14,8 W 14,8 W<br />
10,0<br />
9,7 W 9,7 W 9,7 W<br />
5,0<br />
4,7 W 4,7 W<br />
0,0<br />
0,0 W<br />
0 10 20 30 40 50 60 70 80<br />
Outer Tu [°C]<br />
Help with project planning<br />
Simple thermal layout using dimensioned drawings is<br />
possible (see page E.20) <strong>and</strong> by specifying the built-in<br />
power loss <strong>and</strong> optimal exploitation of available space.<br />
Max interior Tu 50 °C Max interior Tu 60 °C Max interior Tu 70 °C Max interior Tu 80 °C<br />
Tu max = Max. permitted device temperature<br />
56 56<br />
2 10<br />
46 46<br />
135<br />
Ø 3.4<br />
Ø 7.8<br />
4.35<br />
115.4<br />
Please send requests to<br />
KSL@weidmueller.de<br />
159<br />
7.6<br />
1366860000 – 2013<br />
E.5