29.04.2014 Views

Thermocouples - Nuova Elva

Thermocouples - Nuova Elva

Thermocouples - Nuova Elva

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

JUMO GmbH & Co. KG<br />

Delivery address:Mackenrodtstraße 14,<br />

36039 Fulda, Germany<br />

Postal address: 36035 Fulda, Germany<br />

Phone: +49 661 6003-0<br />

Fax: +49 661 6003-607<br />

e-mail: mail@jumo.net<br />

Internet: www.jumo.net<br />

JUMO Instrument Co. Ltd.<br />

JUMO House<br />

Temple Bank, Riverway<br />

Harlow, Essex CM 20 2TT, UK<br />

Phone: +44 1279 635533<br />

Fax: +44 1279 635262<br />

e-mail: sales@jumo.co.uk<br />

Internet: www.jumo.co.uk<br />

JUMO PROCESS CONTROL INC.<br />

885 Fox Chase, Suite 103<br />

Coatesville PA 19320, USA<br />

Phone: 610-380-8002<br />

1-800-554-JUMO<br />

Fax: 610-380-8009<br />

e-mail: info@JumoUSA.com<br />

Internet: www.JumoUSA.com<br />

Data Sheet 90.7031 Page 6/7<br />

H<br />

Order details: Hygro/hygrothermal transducers (hygrometric)<br />

(1) Basic version<br />

907031/10 Hygro/hygrothermal transducer, indoor version (passive)<br />

907031/20 Hygro/hygrothermal transducer, duct version (passive)<br />

907031/30 Hygro/hygrothermal transducer, duct version (active)<br />

907031/50 Hygro/hygrothermal transducer, duct version (Ex i)***<br />

(2) Hygro/hygrothermal transducers<br />

x x x x 1 humidity<br />

x 2 humidity and temperature<br />

x x x 3 humidity and temperature (passive)<br />

(3) Ranges*<br />

x 09 0 to 100% RH / -20 to +40°C<br />

x 21 0 to 100% RH / -30 to +60°C<br />

x 15 0 to 100% RH / -40 to +80°C<br />

x 34 0 to 100% RH / 0 to 60°C<br />

x 36 0 to 100% RH / 0 to 100°C<br />

x x x 99 special range (on request)<br />

(4) Output signals (humidity / temperature)**<br />

x x 016 0 — 100Ω (2-pole output, linear) / Pt100 (passive)<br />

x x 017 0 — 200Ω (2-pole output, linear) / Pt100 (passive)<br />

x x x 019 0 — 1000Ω (2-pole output, linear) / Pt100 (passive)<br />

x x x 021 100 — 138.5Ω (2-pole output, linear) / Pt100 (passive)<br />

x 005 4 — 20mA / 4 — 20mA<br />

x 011 0 — 20mA / 0 — 20mA<br />

x 065 0 — 10V DC / 0 — 10V DC<br />

x x x 999 special output (on request)<br />

(5) Extra codes<br />

x x x x 000 no extra code<br />

x x x 764 mounting bracket (for wall fixing)<br />

x x x 797 wind shield (indoor and outdoor mounting)<br />

x x x 798 sun and rain protection (outdoor mounting)<br />

x x x 799 mounting flange (not absolutely necessary)<br />

(1) (2) (3) (4) (5)<br />

Order code - - - / , ...<br />

Order example 907031/10 - 1 - 15 - 016 / 000 1<br />

1. List extra codes in sequence, separated by commas.<br />

* Please note humidity working range and max. permissible ambient temperature (see Technical data).<br />

** With selection (2) type code 1 “humidity”, the second output signal is not applicable with selection (4).<br />

*** The transducer may only be operated in an intrinsically safe circuit.<br />

Please make sure you only use approved safety barriers, transmitters and devices suitable for the Ex area when operating in the hazardous area!<br />

Note<br />

Suitable power supply units for transmitters (not for Type 907031/50) can be found in Data Sheet 70.7500 (95.6024).<br />

Recommended power supply units: Type TN-22/02, 055 (1-channel) and TN-67/02, 055 (4-channel)<br />

Stock versions<br />

(1) (2) (3) (4) (5) Sales No.<br />

- - - /<br />

907031/10 - 1 - 34 - 021 / 000 90/90590502<br />

907031/10 - 3 - 34 - 021 / 000 90/90590507<br />

907031/20 - 1 - 15 - 021 / 000 90/90590512<br />

907031/20 - 1 - 15 - 019 / 000 90/00403758<br />

907031/20 - 3 - 15 - 021 / 000 90/90590517<br />

907031/30 - 1 - 21 - 005 / 000 90/90590541<br />

907031/30 - 1 - 21 - 065 / 000 90/00332704<br />

907031/30 - 2 - 21 - 065 / 000 90/00332705<br />

907031/30 - 2 - 21 - 005 / 000 90/90590544<br />

907031/30 - 2 - 36 - 005 / 000 90/90590543<br />

12.04/00073489

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!