Turbidity Analyzers Model TRCN-96<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Four Relays<br />
Two 4-20 mA<br />
dc Outputs<br />
NEMA-4X<br />
Menu Guided<br />
Operation<br />
Multiple Language<br />
Prompts (English,<br />
German, French<br />
and Spanish)<br />
Built-In Advanced<br />
System Diagnostics<br />
Long-Lasting<br />
LED Light Source<br />
Four-Beam<br />
Ratiometric<br />
Turbidity<br />
Measurement<br />
Provides<br />
Unparalleled<br />
Stability<br />
High Resolution<br />
at Ultra-Low<br />
Turbidity Levels<br />
Microprocessor-<br />
Based with Self<br />
Diagnostics<br />
0 to 100 NTU<br />
Measuring<br />
Range with<br />
Auto-Ranging<br />
Bubble Rejecting<br />
Sample Chamber<br />
Automatic Color<br />
Compensation<br />
The TRCN-96<br />
low-range turbidimeter<br />
system employs<br />
a technologically<br />
advanced sensor<br />
to provide high<br />
measurement accuracy and<br />
stability, while reducing<br />
maintenance requirements. It is<br />
designed to meet the International<br />
Standards For Measurement of Turbidity<br />
[ISO 7027-1984(E)] and USEPA-approved<br />
method. This system has an auto-ranging<br />
measuring scale, enabling continuous<br />
monitoring over a 0.000 to100.0 NTU<br />
range with automatic decimal point<br />
positioning. The TRCN-96 low-range<br />
turbidimeter system automatically provides<br />
increasing display resolution as measured<br />
turbidity decreases. To further ensure high<br />
measuring accuracy, the sensor eliminates<br />
air or gas bubbles in the sample with its<br />
built-in bubble trap. The system is ideal<br />
for critical monitoring and controlling<br />
applications including potable water,<br />
filtered water, and final product clarity.<br />
The analyzer provides two isolated analog<br />
outputs. Each output represents measured<br />
Analyzer<br />
Sensor<br />
Shown smaller<br />
than actual size<br />
turbidity and is scalable. During<br />
calibration, both analog outputs<br />
can be programmed to hold their<br />
present values, to transfer to<br />
preset values to operate control<br />
elements by an amount<br />
corresponding to those values,<br />
or to remain active to respond to<br />
measured turbidity. The analyzer has four<br />
electromechanical relays, all with SPDT<br />
contacts. Each relay can be set to function<br />
as a control relay, as a dual-alarm relay,<br />
or as a status relay.<br />
Calibrating the TRCN-96 is simple. A funnel<br />
assembly included with the sensor enables<br />
calibration with a traditional liquid turbidity<br />
standard such as Formazin. A unique, optical<br />
calibration cube is also available for easier<br />
calibration. This contains a specially<br />
formulated turbid glass standard which<br />
maintains its turbidity value indefinitely.<br />
The only required maintenance is an<br />
occasional, simple cleaning of the sensor<br />
flow chamber. (System diagnostics<br />
automatically alert the operator when<br />
to clean the sensor flow chamber.)<br />
TRCN-96<br />
$<br />
1995<br />
Includes Sensor<br />
and Analyzer<br />
MADE IN<br />
USA<br />
TR-8220 Optional<br />
Calibration Cube<br />
$450<br />
Order Online<br />
omega.com ®<br />
Over 100,000 Products Available!<br />
For the complete selection of Water Analysis<br />
products, refer to The Green Book ® 137