Conductivity Sensors Series CDE680<br />

Contacting Conductivity Probes for Use with CDTX680 Series<br />

Transmitters and CDCN684, CDCN685 and CDCN686 Series Controllers<br />

CDE681 Compression Fitting Sensor<br />

Typical Mounting<br />

SENSOR CABLE<br />

6.1 M (20')<br />

3/4" PIPE<br />

(CUSTOMER PROVIDED)<br />

3/4" NPT COUPLING<br />

(CUSTOMER PROVIDED)<br />

243.8 mm (9.60")<br />

SENSOR<br />

CLEARANCE FOR<br />

SENSOR REMOVAL<br />

1/2" COMPRESSION<br />

1/2" x 3/4"<br />

FITTING<br />

NPT REDUCER<br />

1/2" COMPRESSION FITTING<br />

88.9 TO 139.7 mm<br />

(3.50 TO 5.50")<br />

SENSOR EXTENSION<br />

1/2 OR 3/4" NPT<br />

THREADED TEE<br />

(CUSTOMER PROVIDED)<br />

SENSOR<br />

FLOW<br />

FLOW<br />

Typical Insertion Mounting<br />

Typical Immersion Mounting<br />

Common Specifications<br />

CDCN684 with<br />

Flow Rate: 0 to 10 ft. (0 to 3 m)<br />

CDE681 Electrode<br />

per second (fully immersed)<br />

Temperature Compensator:<br />

MOST POPULAR MODELS HIGHLIGHTED!<br />

Pt 1000 RTD<br />

Sensor Cable<br />

To Order (Specify Model Number)<br />

Integral (No Junction Box):<br />

6-wire cable (4 conductors and<br />

Compression Temperature/<br />

two isolated shield wires);<br />

Model Cell Fitting Pressure<br />

20 ft. (6 m) long<br />

Number Price Constant Material Thread Limits<br />

Longer lengths available.<br />

CDE681-A-K $275 0.05 Kynar (PVDF) 1<br />

⁄2 NPT When ordered with Kynar<br />

Consult <strong>Engineering</strong><br />

CDE681-A-S 350 316SS (PVDF) compression fitting:<br />

CDE681-B-K 300 0.5 Kynar 3<br />

⁄4 NPT 302°F at psi<br />

CDE681-B-S 375 316SS (150°C at 1.7 bar) or<br />

CDE681 Compression Fitting Style Sensor CDE681-C-K 300 1.0 Kynar 3<br />

⁄4 NPT 97°F at 150 psi<br />

Purposely designed for ultrapure water and<br />

CDE681-C-S 375 316SS (36°C at 10.3 bar)<br />

pure water applications, these small, enhancedperformance<br />

contacting <strong>conductivity</strong> sensors<br />

CDE681-D-S 375 316SS compression fitting:<br />

CDE681-D-K 300 5.0 Kynar 3<br />

⁄4 NPT When ordered with 316SS<br />

provide the required absolute cell (K) constant CDE681-E-K 300 10.0 Kynar 3<br />

⁄4 NPT 302°F at 200 psi<br />

accuracy, and ultrafast-acting temperature<br />

CDE681-E-S 375 316SS (150°C at 13.7 bar)<br />

compensation. Materials of construction extend<br />

sensor operating life with no degradation in Accessory<br />

measurement reliability.<br />

Model Number Price Description<br />

Wetted Parts–Titanium electrodes, PTFE<br />

CDE681-XA-LVFC $75 Low volume flow chamber<br />

insulator and treated Viton ® O-ring seals<br />

This 1 ⁄2 inch Kynar (PVDF) tee is only used with a 0.05 cell constant sensor. It limits sample<br />

volume to approximately 20 ml for high-purity water applications.<br />

Viton ® is a registered trademark of DuPont Dow Elastomers.<br />

256.5 mm (10.10")<br />

6.1 M (20')<br />

31.8 TO 101.6 mm<br />

(1.25 TO 4.00")<br />

INSERTION DEPTH<br />

CLEAR W/BLACK (SENSOR SHIELD)<br />

BLACK (SENSE)<br />

RED (DRIVE)<br />

WHITE (TEMP +)<br />

BLUE(TEMP -)<br />

CLEAR (INNER SHIELD)<br />

1/2" DIA. FOR<br />

0.05 CELL CONSTANT 1/2 or 3/4"<br />

3/4" DIA FOR ALL<br />

NPT THREADS<br />

1/2 or 3/4" COMPRESSION FITTING<br />

OTHER CELL CONSTANTS<br />

CDE681<br />

Order Online<br />

omega.com ®<br />

Over 100 000 Products Available!<br />

For the complete selection of Conductivity<br />

products, refer to The Green Book ® 15