DISSOLVED OXYGEN<br />

Dissolved Oxygen Analyzers<br />

Model DOCN-72<br />

$<br />

1220<br />

Large Display<br />

Replaceable Membrane Cartridge<br />

Rugged Foul-Resistant Membrane<br />

Seven Calibration Methods<br />

Dual Analog Output<br />

Three Relays for Alarm or Control<br />

Advanced Diagnostics<br />

The DOCN-72 is an easy-to-use dissolved<br />

oxygen analyzer/controller designed for use<br />

with the DOE-72 submersible mounted<br />

membrane dissolved oxygen sensor.<br />

The sensor features a replaceable<br />

cartridge, simplifying the task of installing<br />

a new membrane.<br />

Besides viewing measured dissolved oxygen<br />

n ppm or % saturation, you can display<br />

other important system information (analog<br />

output values, process temperature, next<br />

scheduled date of calibration, etc.) by using<br />

the or key to scroll the lower line on the<br />

measurement screen. The analyzer<br />

provides two sets of analog outputs,<br />

each consisting of one 4 to 20 mA and one<br />

0 to 5 Vdc/0 to 1 mA output. Each output<br />

set can be assigned to represent the<br />

measured D.O. (in ppm or % saturation) or<br />

temperature. Also, whenever the analyzer<br />

detects that one of the 4 to 20 mA loops<br />

is open, it displays a “Current Load High”<br />

diagnostic message.<br />

The analyzer logbook records up to 100<br />

system events, including calibrations,<br />

warning and failure messages, powerup/power-down,<br />

and configuration activity.<br />

Each event is logged with the date and time<br />

of occurrence.<br />

MADE IN<br />

USA<br />

Optional<br />

Specifications<br />

Range: 0.00 to 40.00 ppm or 0.0 to<br />

200% saturation 0 to 50°C (32 to 122°F)<br />

Display: Graphic dot matrix LCD, 128 x 64<br />

pixels with LED backlighting; 13 mm ( 1 ⁄2")<br />

main display character height; 3 mm ( 1 ⁄8")<br />

auxiliary information character height<br />

Ambient Conditions: -30 to 60°C<br />

(-22 to 140°F); 0 to 95% relative humidity,<br />

non-condensing<br />

Relays:<br />

Types/Outputs:<br />

Standard: Three electromechanical relays<br />

(two SPDT and one SPST); UL rated 5 A<br />

115/230 Vac, 5 A @ 30 Vdc resistive<br />

Functional Modes: Each relay (A, B and C)<br />

can be assigned to be driven by the<br />

measured D.O. (in ppm or % saturation)<br />

or temperature<br />

30<br />

For the complete selection of Dissolved<br />

Oxygen products, refer to The Green Book ®<br />

For Sales<br />

& Service<br />

USA and Canada<br />

®