UNDERFLOOR HEATING PLATES<br />

Underfloor<br />

Heating/Cooling<br />

01<br />

BUILDING REGULATIONS IN SPAIN<br />

In Spain, the Technical Building Code which took effect in 2006 and<br />

is mandatory, states the requirements to be fulfilled by buildings<br />

with regard to basic safety, habitability and environmental protection<br />

requirements.<br />

The Technical Building Code establishes thermal values for the<br />

building’s cladding: For floor insulation, the Technical Building Code<br />

states that the thermal resistance must be as follows:<br />

cladding<br />

R = 1,45 m 2 K/W (Climate zone A)<br />

LA CORUÑA<br />

LUGO<br />

PONTEVEDRA<br />

OURENSE<br />

ASTURIAS<br />

LEÓN<br />

VIZCAYA GUIPÚZCOA<br />

CANTABRIA<br />

ÁLAVA NAVARRA<br />

PALENCIA<br />

BURGOS<br />

LA RIOJA<br />

HUESCA<br />

LÉRIDA<br />

GIRONA<br />

R = 1,47 m 2 K/W (Climate zone B)<br />

ZAMORA<br />

VALLADOLID<br />

SORIA<br />

ZARAGOZA<br />

BARCELONA<br />

SALAMANCA<br />

GUADALAJARA<br />

TERUEL<br />

ÁVILA<br />

MADRID<br />

CUENCA<br />

CÁCERES<br />

TOLEDO<br />

VALENCIA<br />

CIUDAD REAL<br />

BADAJOZ<br />

ALBACETE<br />

TARRAGONA<br />

CASTELLÓN<br />

BALEARES<br />

R = 1,54 m 2 K/W (Climate zone C)<br />

R = 1,56 m 2 K/W (Climate zone D)<br />

ALICANTE<br />

CÓRDOBA<br />

JAÉN<br />

MURCIA<br />

HUELVA<br />

SEVILLA<br />

GRANADA<br />

ALMERIA<br />

MALAGA<br />

CÁDIZ<br />

R = 1,61 m 2 K/W (Climate zone E)<br />

SANTA CRUZ<br />

LAS PALMAS<br />

Note: The climate zones are as per the capitals. The climate<br />

zone may be affected by the altitude of the works in question.<br />

Taking into account both these values and the resistance established by the underfloor heating standard<br />

UNE-EN 1264, the least favourable value would need to be calculated for each case. This would be the<br />

resistance value all underfloor heating plates must have in order to comply with all of the requirements.<br />

SOUND INSULATION. Basic noise protection requirements (HR)<br />

The aim of the basic “Noise protection” requirement included in the Technical Building Code is to limit,<br />

inside buildings and under normal conditions of use, the risk of nuisance or illnesses that noise may<br />

cause to users as a result of the characteristics of their project, construction, use and maintenance.<br />