Data sheet type 6008A / 6008Ax,x-102<br />
Miniature cavity<br />
pressure sensor<br />
Type 6008A / 6008<br />
008Ax,x<br />
x,x-102<br />
• Front-Ø: 1 mm<br />
• With separable cable<br />
• No single wire cable!<br />
• Interference-free measuring signal through secure ground closure<br />
• <strong>Sensor</strong> front can be adapted to cavity<br />
• Measuring range up to 2000 bar<br />
• Suitable for all melt temperatures in injection molding<br />
• For optimization, quality monitoring and control of the injection<br />
molding process<br />
• Piezoelectric measuring principle<br />
Description<br />
Due to the very small dimensions the cavity pressure sensor type 6008A can be used even in molds with<br />
very limited space available. The sensor is compatible to other on the market available sensors, however it<br />
provides two essential advantages: on the one hand the cable can be replaced if damaged, and on the<br />
other hand the cable is equipped with a secure shielding. Therefore interference signals from the mold<br />
based on a missing ground closure are excluded. The sensor can be easily connected both to a<br />
PRIAMUS® charge amplifier or to charge amplifiers of other manufactures.<br />
Alternatives<br />
Type<br />
Connecting Cable<br />
Connector<br />
Connected to<br />
6008A Only sensor - -<br />
6008Ax,x-102<br />
6008Asl-102<br />
<strong>Sensor</strong> with connecting<br />
cable Typ 1011A<br />
Fischer KBE 102 female<br />
TRIAX<br />
BlueLine devices:<br />
5080A, 5070A, 1195A-8p<br />
Application<br />
Optimization, monitoring and control of the injection molding process with limited space available in the<br />
mold.<br />
Technical Data<br />
Specifications<br />
Unit<br />
Value<br />
Measuring range bar 0…2000<br />
Overload bar 2500<br />
Sensitivity 1) pC / bar 2.1<br />
Maximum melt temperature (plastics) in the cavity 2) °C no limitation<br />
Maximum mold temperature 3) °C 200<br />
Deviation of linearity % < ± 1<br />
Insulation resistance Ω 10 13 (bei 20 °C)<br />
1)<br />
The exact sensitivity is provided on a separate calibration sheet.<br />
2)<br />
The plastic melt cools immediately after contacting the cavity wall. The melt temperature is therefore without any practical meaning for the<br />
sensor (thermoplastics). For thermosets and elastomers the permanent melt temperatures are usually below 200 °C.<br />
3)<br />
The permanent temperature of the sensor body can be higher than the specified value of the mold temperature. The temperature at the cable<br />
connector however is limited. An exceeding of the specified mold wall temperature up to 240 °C is possible for the short period.<br />
4)<br />
The actual natural frequency of the sensor is far higher than the frequency spectrum of the effective signal.<br />
PRIAMUS SYSTEM TECHNOLOGIES AG 1/4 PRIAMUS SYSTEM TECHNOLOGIES, LLC<br />
Rheinweg 4<br />
3061 Nationwide Parkway<br />
CH-8200 Schaffhausen / Switzerland USA-Brunswick, OH 44212<br />
Tel: +41 (0)52 632 2626 Tel: +1 (0)877 774 2687<br />
Fax: +41 (0)52 632 2627 Fax: +1 (0)877 678 5062<br />
E-Mail: info@priamus.com<br />
E-Mail: salesus@priamus.com<br />
http://www.priamus.com<br />
http://www.priamus.com<br />
DS6008_069e Ed. 09.13<br />
Subject to technical amendments<br />
Projection method: First Angle Projection
Data sheet type 6008A / 6008Ax,x-102<br />
Remarks<br />
The sensors including connecting cable can be cleaned in an ultrasonic bath (aqueous tenside solution)<br />
together with the mold inserts if a sealed protecting cap is used.<br />
By standard the pressure sensors are delivered with a mounting nut (standard-mounting). Alternatively the<br />
pressure sensors can also be installed with a distance sleeve.<br />
Dimensions<br />
<strong>Sensor</strong> with cable and connector<br />
Standard-mounting<br />
Borehole in case of mounting nut<br />
Installation situation with mounting nut<br />
Option:<br />
Positioning area<br />
(specify when ordering)<br />
*= Adjust dimension<br />
PRIAMUS SYSTEM TECHNOLOGIES AG 2/4 PRIAMUS SYSTEM TECHNOLOGIES, LLC<br />
Rheinweg 4<br />
3061 Nationwide Parkway<br />
CH-8200 Schaffhausen / Switzerland USA-Brunswick, OH 44212<br />
Tel: +41 (0)52 632 2626 Tel: +1 (0)877 774 2687<br />
Fax: +41 (0)52 632 2627 Fax: +1 (0)877 678 5062<br />
E-Mail: info@priamus.com<br />
E-Mail: salesus@priamus.com<br />
http://www.priamus.com<br />
http://www.priamus.com<br />
DS6008_069e Ed. 09.13<br />
Subject to technical amendments<br />
Projection method: First Angle Projection
Data sheet type 6008A / 6008Ax,x-102<br />
Alternative mounting<br />
Borehole in case of distance sleeve<br />
Installation situation with distance sleeve<br />
Option:<br />
Positioning area<br />
(specify when ordering)<br />
*= Adjust dimension<br />
Scope of delivery<br />
Mounting plate<br />
Mounting nut<br />
PRIAMUS SYSTEM TECHNOLOGIES AG 3/4 PRIAMUS SYSTEM TECHNOLOGIES, LLC<br />
Rheinweg 4<br />
3061 Nationwide Parkway<br />
CH-8200 Schaffhausen / Switzerland USA-Brunswick, OH 44212<br />
Tel: +41 (0)52 632 2626 Tel: +1 (0)877 774 2687<br />
Fax: +41 (0)52 632 2627 Fax: +1 (0)877 678 5062<br />
E-Mail: info@priamus.com<br />
E-Mail: salesus@priamus.com<br />
http://www.priamus.com<br />
http://www.priamus.com<br />
DS6008_069e Ed. 09.13<br />
Subject to technical amendments<br />
Projection method: First Angle Projection
Data sheet type 6008A / 6008Ax,x-102<br />
Accessories<br />
Distance sleeve<br />
Scope of delivery<br />
Article<br />
Type<br />
Article<br />
Type<br />
Mounting nut 6544B Identification plate -<br />
Mounting plate 6581B Connecting cable (for 6008Ax,x-102) 1011A<br />
Accessories (optional<br />
optional)<br />
Article<br />
Type<br />
Article<br />
Type<br />
Distance sleeve 6523B PRIAFIT ® Mounting sleeve 6531A<br />
Mounting / extraction tool for the sensor 6568A Assembly tool for mounting nut and 6567A<br />
mounting sleeve<br />
Assembling aid 6585A Dummy 6508A<br />
Multi channel connecting box for<br />
1195A-8p<br />
6008Ax,x-102<br />
Connecting cable:<br />
Type<br />
1041A<br />
1042A<br />
1049A<br />
Sensitivity detection<br />
with and without<br />
with and without<br />
with and without<br />
Connector<br />
Fischer Type S 102 male – Fischer Type S 102 male<br />
Fischer Type S 102 male – Fischer Type S 102 male<br />
Fischer Type S 102 male – Fischer Type S 102 male<br />
Multi pin<br />
connecting cable:<br />
Type<br />
1045A<br />
1046A<br />
1047A<br />
1048A<br />
1054B<br />
Extension cable:<br />
Type<br />
1043A<br />
Order code<br />
Sensitivity detection<br />
with and without<br />
with and without<br />
with and without<br />
with and without<br />
with and without<br />
Sensitivity detection<br />
with and without<br />
Connector<br />
Fischer 16-pol Type S 104 fem. – 4 x Fischer Type S 102 male<br />
Fischer 16-pol Type S 104 fem. – 8 x Fischer Type S 102 male<br />
Fischer 16-pol Type S 104 fem. – 1 x Fischer Type S 102 male<br />
Fischer 16-pol Type S 104 fem. – 2 x Fischer Type S 102 male<br />
Fischer 16-pol fem. - Fischer 16-pol fem.<br />
Connector<br />
Fischer Type S 102 male – Fischer Type KBE 102 fem.<br />
6008A<br />
Only <strong>Sensor</strong><br />
6008Ax,x-102 x,x: cable length in [m] l = 0,2 / 0,4 / 0,6 / 0,8 / 1,0 / 1,2 m<br />
6008Asl-102 sl: cable length in [m] Special length<br />
PRIAMUS SYSTEM TECHNOLOGIES AG 4/4 PRIAMUS SYSTEM TECHNOLOGIES, LLC<br />
Rheinweg 4<br />
3061 Nationwide Parkway<br />
CH-8200 Schaffhausen / Switzerland USA-Brunswick, OH 44212<br />
Tel: +41 (0)52 632 2626 Tel: +1 (0)877 774 2687<br />
Fax: +41 (0)52 632 2627 Fax: +1 (0)877 678 5062<br />
E-Mail: info@priamus.com<br />
E-Mail: salesus@priamus.com<br />
http://www.priamus.com<br />
http://www.priamus.com<br />
DS6008_069e Ed. 09.13<br />
Subject to technical amendments<br />
Projection method: First Angle Projection