Central Control Unit (CCU)<br />
For Remote Electrical Tilt (RET) and<br />
Tower Mounted Amplifier (TMA) Control<br />
for outdoor use<br />
Central Control Unit, outdoor<br />
Type No.<br />
Connectors to RCU/Splitter<br />
860 10113<br />
1 x 8 pin connector according IEC 60130-9, female, conform to AISG<br />
Power supply from BTS<br />
DC: –48 V / max. 1.7 A<br />
Power supply to RCU<br />
+29 V DC / max. 1.7 A<br />
+13 V DC / max. 3.8 A<br />
Total output power<br />
Max. 50 W<br />
Interface to RCU and TMA<br />
RS 485 / power supply, conform to AISG<br />
Protocol to RCU and TMA<br />
HDLC hex-coded command set, conform to AISG<br />
Interface to BTS RJ 45, 10 <strong>Base</strong>-T, Ethernet 802.3<br />
Protocols to BTS<br />
TCP/IP, UDP, HTTP/HTML, DHCP, FTP, ICMP/PING, SNMP<br />
Alarm Interface<br />
1 x open collector output<br />
Lightning Protection 10/350 µs, 3.5 kA for AISG interface 1)<br />
8/20 µs, 2.5 kA Ethernet- , DC- and Alarm Interface<br />
Max. number of RCU’s<br />
Up to 27 RCU’s in daisy chain und up to 6 DTMA’s;<br />
and/or TMA’s depending on cable configuration and max. power 2)<br />
Max. length of control cable 200 m (9 RCU’s in daisy chain configuration) 2)<br />
Material of housing Covers: Aluminium, varnished (lightgrey, RAL 7035)<br />
Profile: Glass-fibre reinforced plastic (lightgrey)<br />
Temperature range<br />
–40 °C ... +55 °C ambient temperature<br />
Protection class IP 65 3)<br />
Mounting 4)<br />
Wall and mast mounting (with additional clamps)<br />
Weight<br />
4.5 kg<br />
Dimensions (h x w x d)<br />
328 mm x 270 mm x 131 mm<br />
Cable feedthrough with<br />
gasket at the bottom side.<br />
1) Please note: In order to achieve lightning protection acc. to IEC 61643-1/-3 (10/350µs), please install<br />
the Kathrein Lightning Protection Device (type-no. 860 10030). For additional information about lightning<br />
protection of the CCU, we kindly refer to the RET Installation Manual.<br />
2) Please refer to the RET Installation Manual for detailed information.<br />
3) Please note: Appropriate cables must be used (see RET Installation Manual for additional information)<br />
4) Please note: Cable feedthrough must point downward!<br />
The cable installation must provide adequate strain relief!<br />
The CCU should not be installed at locations with hazardous risks for the installation team!<br />
Please follow the instructions in the RET Installation Manual.<br />
Standards: EN 60950-1 (Safety)<br />
EN 55022 (Emission)<br />
EN 55024 (Immunity)<br />
ETS 300019-1-4 (Environmental)<br />
Certifications: CE<br />
Scope of supply: Central Control Unit, outdoor<br />
Connectors for Power Supply and<br />
Alarm interface Installation manual<br />
Interfaces at the internal<br />
connector panel.<br />
Block diagram: CCU – outdoor<br />
Alarm<br />
DC –48 V<br />
Ethernet<br />
AISG<br />
LED signalling<br />
RET<br />
GND<br />
to BTS<br />
to RET / Antenna<br />