Central Control Unit (CCU)<br />

For Remote Electrical Tilt (RET) and<br />

Tower Mounted Amplifier (TMA) Control<br />

for outdoor use<br />

Central Control Unit, outdoor<br />

Type No.<br />

Connectors to RCU/Splitter<br />

860 10113<br />

1 x 8 pin connector according IEC 60130-9, female, conform to AISG<br />

Power supply from BTS<br />

DC: –48 V / max. 1.7 A<br />

Power supply to RCU<br />

+29 V DC / max. 1.7 A<br />

+13 V DC / max. 3.8 A<br />

Total output power<br />

Max. 50 W<br />

Interface to RCU and TMA<br />

RS 485 / power supply, conform to AISG<br />

Protocol to RCU and TMA<br />

HDLC hex-coded command set, conform to AISG<br />

Interface to BTS RJ 45, 10 <strong>Base</strong>-T, Ethernet 802.3<br />

Protocols to BTS<br />

TCP/IP, UDP, HTTP/HTML, DHCP, FTP, ICMP/PING, SNMP<br />

Alarm Interface<br />

1 x open collector output<br />

Lightning Protection 10/350 µs, 3.5 kA for AISG interface 1)<br />

8/20 µs, 2.5 kA Ethernet- , DC- and Alarm Interface<br />

Max. number of RCU’s<br />

Up to 27 RCU’s in daisy chain und up to 6 DTMA’s;<br />

and/or TMA’s depending on cable configuration and max. power 2)<br />

Max. length of control cable 200 m (9 RCU’s in daisy chain configuration) 2)<br />

Material of housing Covers: Aluminium, varnished (lightgrey, RAL 7035)<br />

Profile: Glass-fibre reinforced plastic (lightgrey)<br />

Temperature range<br />

–40 °C ... +55 °C ambient temperature<br />

Protection class IP 65 3)<br />

Mounting 4)<br />

Wall and mast mounting (with additional clamps)<br />

Weight<br />

4.5 kg<br />

Dimensions (h x w x d)<br />

328 mm x 270 mm x 131 mm<br />

Cable feedthrough with<br />

gasket at the bottom side.<br />

1) Please note: In order to achieve lightning protection acc. to IEC 61643-1/-3 (10/350µs), please install<br />

the Kathrein Lightning Protection Device (type-no. 860 10030). For additional information about lightning<br />

protection of the CCU, we kindly refer to the RET Installation Manual.<br />

2) Please refer to the RET Installation Manual for detailed information.<br />

3) Please note: Appropriate cables must be used (see RET Installation Manual for additional information)<br />

4) Please note: Cable feedthrough must point downward!<br />

The cable installation must provide adequate strain relief!<br />

The CCU should not be installed at locations with hazardous risks for the installation team!<br />

Please follow the instructions in the RET Installation Manual.<br />

Standards: EN 60950-1 (Safety)<br />

EN 55022 (Emission)<br />

EN 55024 (Immunity)<br />

ETS 300019-1-4 (Environmental)<br />

Certifications: CE<br />

Scope of supply: Central Control Unit, outdoor<br />

Connectors for Power Supply and<br />

Alarm interface Installation manual<br />

Interfaces at the internal<br />

connector panel.<br />

Block diagram: CCU – outdoor<br />

Alarm<br />

DC –48 V<br />

Ethernet<br />

AISG<br />

LED signalling<br />

RET<br />

GND<br />

to BTS<br />

to RET / Antenna<br />