Technical Details<br />
The 5 Possible <strong>CCTV</strong> Recommended System Configurations<br />
Matrix 8 Channels via Coaxial Connections<br />
No Recording, Analog type camera.<br />
Connect camera to matrix and matrix to TV or Monitor.<br />
DVR 4, 8 and 16 Channels via Coaxial Connections<br />
USE: Best used for Recording.<br />
Camera Type: Analog<br />
Max No. of <strong>Cameras</strong> 4, 8 or 16 Video cameras.<br />
Recommendation: Not Recommended for Motion Sensing.<br />
Requires: TV or Monitor.<br />
Cable Type: DVR to Camera Coaxial Cable, RG59 Copper Shielded is the<br />
only cable we accept to use.<br />
Length of Cable:- Coaxial: 305 Meter, Passive System: 600 Meter, Active<br />
System: 2400 Meter, Fiber Optic: 20 kilometer.<br />
<strong>Cameras</strong> Multiplexer TV<br />
4/8/16 <strong>Cameras</strong><br />
4/8/16 Channel<br />
DVR<br />
Monitor<br />
A<br />
RG59<br />
Cable Type<br />
A<br />
RG59<br />
Cable Type<br />
PCDVR 4, 8, 12,16, 32, 48 & 64 Channels via Coaxial Connections<br />
USE: Best used for Recording and Motion Sensing.<br />
Camera Type: Analog.<br />
Max No. of <strong>Cameras</strong> 4, 8, 12, 16, 32, 48, or 64 cameras, with 4, 8, 12, 16, 32,<br />
48 or 64 audio channels.<br />
Recommendation: Recommended for Recording and Motion Sensing.<br />
Requires: PC or Server, 580GB/HD and 17”LCD or equivalent.<br />
Cable Type: PC to Camera Coaxial Cable, RG59 Copper Shielded is the only<br />
cable we accept to use.<br />
Length of Cable:- Coaxial: 305 Meter, Passive System: 600 Meter, Active<br />
System: 2400 Meter, Fiber Optic: 20 kilometer.<br />
4/8/12/16/32/48/64<br />
<strong>Cameras</strong><br />
4/8/12/16/32/48/64<br />
Channel PCDVDVR<br />
Monitors<br />
A<br />
RG59<br />
Cable Type<br />
IP Camera<br />
IP Solution via Ether<strong>net</strong> LAN and Coaxial Connections<br />
USE: Best used for recording, Motion Sensing, People Counting and Securing<br />
areas.<br />
Camera Type: Analog with IP NVR.<br />
Max No. of <strong>Cameras</strong> 10 Ether<strong>net</strong> Ports (Available from Server) x 16 Channel<br />
IP Converters = 160 <strong>Cameras</strong>.<br />
Recommendation: Recommended for Recording, Motion Sensing, People<br />
Counting and Securing Areas.<br />
Requires: Server, 2.4TB / 2400GB/HD, 10 Ether<strong>net</strong> Ports and 40” LCD.<br />
Cable Type: Server to IP Converter Ether<strong>net</strong> Cable, then Coaxial Cable to<br />
Camera, RG59 Copper Shielded is the only cable we accept to use.<br />
Length of Cable:- Coaxial: 305 Meter, Passive System: 600 Meter, Active<br />
System: 2400 Meter, Fiber Optic: 20 kilometer.<br />
Analog<br />
Camera<br />
Analog<br />
PTZ Camera<br />
A<br />
A<br />
Encoder<br />
Encoder<br />
Joystic<br />
B<br />
LAN<br />
B<br />
Decoder<br />
Server<br />
LCD<br />
A<br />
RG59<br />
Cable Type<br />
B<br />
CAT-6<br />
Cable Type<br />
IP Solution Fiber Optic and Ether<strong>net</strong> Based<br />
USE: Best used for Recording, Motion Sensing, People Counting and Securing<br />
Areas.<br />
Camera Type: Analog with IP NVR:.<br />
Max No. of <strong>Cameras</strong> 15000 <strong>Cameras</strong> Plus, 1audio available on 4 channel IP<br />
converter, 1 audio available on 8 channel IP converter, 1 audio available on<br />
16 channel IP converter also.<br />
Recommendation: Recommended for Recording, Motion Sensing, People<br />
Counting and Securing Areas.<br />
Requires: DELL PowerEdge 2900 Tower, 2.4TB / 2400GB/HD, 10<br />
Ether<strong>net</strong> Ports and 40” LCD.<br />
Cable Type: Server to Alloptic chasse - Ether<strong>net</strong> cable, Chasse to ONT<br />
(Optical Network Terminal) – Fiber Optic, ONT to IP Converter – Ether<strong>net</strong>,<br />
IP Converter to camera – Copper cable (RG59 Copper shielded).<br />
Length of Cable:- Coaxial: 305 Meter, Passive System: 600 Meter, Active<br />
System: 2400 Meter, Fiber Optic: 20 kilometer.<br />
IP Converter System Requirement for fiber optic Solution or LAN solution using CAT-6.<br />
Software (only viewing; no recording).<br />
Must use NVR (Network Video Recorder) for recording. (Required details - Number of cameras. Schematic drawing of building. Frames per second (NTSC<br />
30Frames/s. PAL 25Frames/s). No. of Recording Days (30days).<br />
PC for converter.<br />
Switch for Fiber Optic installation - (send schematic drawing to us; we will design proper switch).<br />
4 Channel converter. - (Required band width per channel).<br />
Note: This is Network Dependent.<br />
Code J<br />
268 Tel.: + 966 2 683 690 3631 0244 Fax: + 966 2 682 690 6351 0675<br />
A<br />
Analog<br />
Camera<br />
B<br />
IP Encoder<br />
ONT<br />
C<br />
Chassis<br />
Keyboard<br />
B<br />
Decoder<br />
LCD<br />
Server<br />
Joystick<br />
A<br />
B<br />
C<br />
RG59<br />
Cable Type<br />
CAT-6<br />
Cable Type<br />
Fiber<br />
Optic<br />
Cable Type