Technical Details<br />
Note 1: if a customer requires a detailed distance measurement during the Survey process. A Survey Charge Prior to installation,<br />
the charge for actual opening ceiling panels, floor panels and wall conduits to enable a perfect distance measurement<br />
will be 3.00SR per linear meter.<br />
Note: 2: If Note 1 was not selected, then Note 3 will apply as a mandatory prior to the <strong>CCTV</strong> quotation agreement.<br />
Note 3: For the Bill of Quantities, all distances have been measured to the best of the technician's ability and without actually<br />
opening ceiling panels, floor panels and wall conduits to enable a perfect distance measurement and charging the client<br />
for such a detailed service as in Note 1, prior to the installation. Thus a post project measurement charge will apply for the<br />
extra distances developed during the installation at the rate of _____ per linear meter for electrical wiring and ____ RG59<br />
Coaxial and Cat 6, and ____ Fiber Optic.<br />
Note 4: The stander DVR BNC screen output are 2 at maximum of 10 meters.<br />
Note 5: The maximum DVR BNC empowered output are 4 screens at 300 meters. Additional charge will be billed per linear<br />
for each LCD Monitor linear meter cabling as well as the cost of equipment. Thus a post project measurement charge will<br />
apply at the rate of _____ per linear meter for electrical wiring and ____ RG59 Coaxial.<br />
Note 6: The ultimate maximum DVR BNC empowered output are 4 screens at boosted signal of 600 meters. Additional<br />
charge<br />
will be billed per linear for each LCD Monitor linear meter cabling as well as the cost of equipment. Thus a post project<br />
measurement charge will apply at the rate of _____ per linear meter for electrical wiring and ____ RG59 Coaxial.<br />
Note 7: The standard EVGA from servers are 2 as a distance of 10 meters maximum.<br />
Note 8: The maximum Server EVGA screen output via external additional equipment are 4 screens at 50 meters. Additional<br />
charge will be billed per linear for each LCD Monitor linear meter cabling as well as the cost of equipment. Thus a<br />
post project measurement charge will apply at the rate of _____ per linear meter for electrical wiring and ____ EVGA Cable.<br />
Note 9: The ultimate maximum Server EVGA screen output via external additional equipment are 4 screens at 200 meters<br />
(not recommended). Additional charge will be billed per linear for each LCD Monitor linear meter cabling as well as the<br />
cost of equipment such as EVGA Booster and Splitters. Thus a post project measurement charge will apply at the rate of<br />
_____ per linear meter for electrical wiring and ____ EVGA Cable.<br />
RG59 Coaxial<br />
RJ45 (Cat-5)<br />
RJ45 (Cat-6)<br />
RJ11(Cat-4)<br />
PVC Coating<br />
Copper Shielded<br />
White PVC<br />
Copper Core<br />
BNC Connector<br />
CAT-5 connector<br />
CAT-6 connector<br />
RJ 11 Connector<br />
Code<br />
J<br />
Web: Web: www.sofab.<strong>net</strong><br />
www.sofab.cc Email: Email: help@sofab.<strong>net</strong><br />
help@sofab.cc 269