Start-up <strong>and</strong> Operation issues:<br />

o<br />

o<br />

There are more failures of a similar nature…..even on the first<br />

unit with the repaired base-pad, the tighter warm-up controls<br />

<strong>and</strong> more accurate hot alignment.<br />

Other issues with the units are discovered<br />

• Seal failures due to poor balancing of seal flush rates to<br />

each end of the machine…the piping gets changed.<br />

• More insulation is added to the casing, balance line loop<br />

<strong>and</strong> warm-up piping to prevent blockage.<br />

• Modifications to warm-up piping are proposed to improve<br />

flow control when units are cold but never implemented.