Start-up <strong>and</strong> Operation issues:<br />

o<br />

The minimum flow control system<br />

• During normal operation the closed minimum flow valve<br />

would cool off <strong>and</strong> not open properly when forward flow<br />

to the process was cut back at the fired heater.<br />

• The small filters in the pump discharge flow meter purge<br />

oil system would continually plug up taking the flow<br />

meter off-line or make the measurement in-accurate. The<br />

operators had to manually control the min-flow valve with<br />

absolutely no information as to the actual pump flow rate.<br />

• The pump discharge pressure at less than min-flow was<br />

enough to force the min-flow valve closed. The actuator<br />

was not sized big enough to keep the valve open!