Start-up <strong>and</strong> Operation issues:<br />
o<br />
The minimum flow control system<br />
• During normal operation the closed minimum flow valve<br />
would cool off <strong>and</strong> not open properly when forward flow<br />
to the process was cut back at the fired heater.<br />
• The small filters in the pump discharge flow meter purge<br />
oil system would continually plug up taking the flow<br />
meter off-line or make the measurement in-accurate. The<br />
operators had to manually control the min-flow valve with<br />
absolutely no information as to the actual pump flow rate.<br />
• The pump discharge pressure at less than min-flow was<br />
enough to force the min-flow valve closed. The actuator<br />
was not sized big enough to keep the valve open!