Operating Instructions<br />
8 Troubleshooting<br />
Malfunction Causes <strong>Co</strong>rrective action<br />
Pump does not work when<br />
switched on<br />
Magnetic clutch is<br />
disengaged<br />
Motor is overheating<br />
No voltage<br />
Impurities in the pump<br />
housing<br />
Specific gravity and/or<br />
viscosity of the fluid is too<br />
high<br />
Pump was switched off, then<br />
switched on again before the<br />
rotor stopped<br />
Clogged ventilator cowl<br />
Test the voltage<br />
Remove the impurities<br />
Reduce the delivery rate; use<br />
a stronger magnetic clutch<br />
and a more powerful motor<br />
The rotor should have<br />
stopped before the pump can<br />
be switched on again<br />
Clean the ventilator and the<br />
cowl<br />
Pump is working, but not<br />
delivering<br />
Motor is overloaded<br />
Gas accumulation in the lines<br />
Reduce the delivery rate<br />
Use a stronger motor<br />
Evacuate the lines<br />
Valve in suction / delivery line Open the valves<br />
is closed<br />
Too much flow noise Cavitation Increase the suction line<br />
cross-section<br />
Reduce the delivery rate<br />
cool down the fluid<br />
Pump is not sucking No fluid in the pump Open the vane<br />
Delivery rate too low<br />
Delivery rate too high<br />
Air in the system<br />
Suction and delivery line<br />
cross-sections are too small<br />
(significant losses)<br />
Valve is not entirely open<br />
Pump losses are less<br />
significant than presumed<br />
Evacuate the system<br />
Increase the suction and<br />
delivery line cross-sections<br />
Entirely open the valve<br />
Install a flow control valve in<br />
the delivery line<br />
17