Operating Instructions<br />

8 Troubleshooting<br />

Malfunction Causes <strong>Co</strong>rrective action<br />

Pump does not work when<br />

switched on<br />

Magnetic clutch is<br />

disengaged<br />

Motor is overheating<br />

No voltage<br />

Impurities in the pump<br />

housing<br />

Specific gravity and/or<br />

viscosity of the fluid is too<br />

high<br />

Pump was switched off, then<br />

switched on again before the<br />

rotor stopped<br />

Clogged ventilator cowl<br />

Test the voltage<br />

Remove the impurities<br />

Reduce the delivery rate; use<br />

a stronger magnetic clutch<br />

and a more powerful motor<br />

The rotor should have<br />

stopped before the pump can<br />

be switched on again<br />

Clean the ventilator and the<br />

cowl<br />

Pump is working, but not<br />

delivering<br />

Motor is overloaded<br />

Gas accumulation in the lines<br />

Reduce the delivery rate<br />

Use a stronger motor<br />

Evacuate the lines<br />

Valve in suction / delivery line Open the valves<br />

is closed<br />

Too much flow noise Cavitation Increase the suction line<br />

cross-section<br />

Reduce the delivery rate<br />

cool down the fluid<br />

Pump is not sucking No fluid in the pump Open the vane<br />

Delivery rate too low<br />

Delivery rate too high<br />

Air in the system<br />

Suction and delivery line<br />

cross-sections are too small<br />

(significant losses)<br />

Valve is not entirely open<br />

Pump losses are less<br />

significant than presumed<br />

Evacuate the system<br />

Increase the suction and<br />

delivery line cross-sections<br />

Entirely open the valve<br />

Install a flow control valve in<br />

the delivery line<br />

17