21.07.2014 Views

AccuFlex™ - Boston Scientific

AccuFlex™ - Boston Scientific

AccuFlex™ - Boston Scientific

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AccuFlex <br />

Single-Use Holmium Laser Fiber<br />

Reliability<br />

Performance<br />

Flexibility


AccuFlex <br />

Single-Use Holmium Laser Fiber<br />

The AccuFlex Single Use Holmium Laser Fiber is designed to efficiently deliver focused holmium energy and offers the<br />

necessary flexibility to meet the challenging deflection needs of flexible ureteroscopy. The AccuFlex Fiber combines a patented<br />

Black Hole SMA Connector with a specialized fiber construction that is designed to maximize performance and flexibility while<br />

minimizing scope and laser console damage. The AccuFlex Fiber also features a laser-polished distal output tip designed to<br />

prevent energy loss as the laser energy leaves the fiber.<br />

EFFICIENT ENERGY TRANSMISSION<br />

An independent study demonstrated that the AccuFlex 200 Fiber delivered up to<br />

63% more energy than the ACMI/Dornier 200 Brand Fiber at the same power settings.*<br />

Energy output of 200 micron<br />

fibers with 500mJ input*<br />

450<br />

400<br />

350<br />

408<br />

300<br />

FLEXIBILITY<br />

The construction of the AccuFlex Single Use Laser Fiber offers a high degree of flexibility<br />

compared to other fibers. In an independent study the AccuFlex 200 Micron Fiber was<br />

mJ<br />

250<br />

200<br />

150<br />

100<br />

250<br />

shown to deflect up to 272 degrees in a DUR -8 Elite ureteroscope.*<br />

50<br />

0<br />

ACMI/Dornier<br />

200<br />

AccuFlex<br />

200<br />

VARIETY OF SIZES<br />

The AccuFlex Fiber is offered in a wide variety of sizes to meet the needs of different surgical situations. The smaller<br />

AccuFlex Fiber sizes are designed for optimum performance during flexible ureteroscopy, offering a high degree of flexibility<br />

and visibility. The larger sizes are well suited for semi-rigid ureteroscopy, cystoscopy, and percutaneous applications. The<br />

AccuFlex 150 Fiber is the smallest core urology fiber available today.<br />

FIBER TIPS FIBER SIZE MAXIMUM POWER INPUT APPLICATIONS<br />

AccuFlex 150 6 watts Flexible Endoscopes<br />

AccuFlex 200 25 watts Flexible Endoscopes<br />

AccuFlex 273 40 watts Flexible Endoscopes<br />

AccuFlex 365 100 watts Flexible and Rigid Endoscopes<br />

AccuFlex 550 100 watts Flexible and Rigid Endoscopes<br />

AccuFlex 1000 100 watts Rigid Endoscopes<br />

*Source: Comparison of Seven Holmium:YAG Laser Optical Fibers by Bodo Knudsen et al, presented at 2003 AUA.


BLACK HOLE SMA CONNECTOR<br />

The AccuFlex Single Use Laser Fibers use<br />

the Black Hole Proximal SMA Connector. This<br />

SMA connector is designed to diffuse errant<br />

laser energy in the event that a laser console’s<br />

laser beam is not perfectly aligned as it enters<br />

the fiber. This corrective feature is designed<br />

to address a cause of fiber “burn out” in<br />

competitive laser fibers. Fiber “burn out” is a<br />

common cause of scope damage and preventing<br />

“burn out” can save costly repairs. The hermetic<br />

fiber face is designed to prevent damage to<br />

laser optics which can also be costly.<br />

Fiber Core<br />

}<br />

{<br />

Hermetic Silica Ferrule guides overfill<br />

laser energy away from fiber core<br />

{<br />

SMA 905 laser<br />

connector<br />

FLEXIBILITY, IRRIGATION<br />

& VISIBILITY<br />

LASER POLISHED OUTPUT TIP<br />

Conventional, mechanically cleaved fiber tips absorb laser energy in the tip’s imperfections,<br />

resulting in fiber “burn back” where the glass of the tip deteriorates throughout the<br />

procedure. This tip deterioration can result in loss of energy delivery of up to 30%.** The<br />

laser-polished tip of the AccuFlex Fiber is designed to offer efficient energy transmission and<br />

may reduce fiber deterioration. Because the AccuFlex Fiber is single use, every case starts<br />

with a new laser-polished tip for optimum performance.<br />

(Schematic illustration of relative<br />

proportional difference in fiber core<br />

diameters when compared to the<br />

diameter of the working channel of<br />

a flexible ureteroscope.)<br />

AccuFlex 150 Fiber Tip<br />

Competitor’s Fiber Tip<br />

AccuFlex 1000 Micron Fiber<br />

Laser-polished tip designed to<br />

reduce “burn back”<br />

Both fibers<br />

shown at<br />

25x actual<br />

diameter.<br />

Both fibers are<br />

brand new.<br />

ACMI/Dornier Brand<br />

1000 Micron Fiber<br />

All photographs taken by <strong>Boston</strong> <strong>Scientific</strong> Corporation. Bench test results may not necessarily be indicative of clinical performance.<br />

**Source: Effect of Lithotripsy on Holmium:YAG Optical Beam Profile, Lee et al, Journal of Endourology, Volume 17, Number 2, March 2003.<br />

The core size of the AccuFlex 150<br />

Fiber is 45% smaller than the core<br />

of the ACMI/Dornier Super 200<br />

Fiber. Smaller devices create less<br />

resistance to steering flexible ureteroscopes<br />

and offer better irrigation and<br />

visibility than larger devices. The<br />

AccuFlex 150 Fiber is the smallest<br />

commercially available fiber for use<br />

with Holmium lasers.


AccuFlex <br />

Single-Use Holmium Laser Fiber<br />

DESIGNED TO MINIMIZE SCOPE DAMAGE<br />

Damage to your flexible ureteroscope can be a costly and frustrating outcome of using<br />

inferior laser fibers. The AccuFlex Fiber is designed to minimize the risk of scope<br />

damage caused by thermal breakdown of fibers during use.<br />

Independent tests also observed that the ACMI/Dornier 200 Micron Fibers “fractured<br />

repeatedly at a bend diameter of 2cm” and concluded that “for small fibers, the Dornier<br />

Fiber has the lowest threshold for fracturing and is most likely to damage a flexible<br />

ureteroscope.”***<br />

AccuFlex Fibers are not intended for use with Lumenis lasers and have not been validated to work on<br />

Lumenis lasers. Using any NON-Lumenis laser fibers on Lumenis lasers may void the customer’s<br />

warranty and should not be attempted.<br />

AccuFlex 200 Fiber in a fully<br />

deflected Storz Flex-X ® Scope<br />

ORDERING INFORMATION<br />

ACCUFLEX SINGLE-USE HOLMIUM LASER FIBER<br />

PRODUCT CODE DESCRIPTION SIZE UNITS<br />

M0068408010 AccuFlex 150 Single Use Holmium Laser Fiber 150 Micron Each<br />

M0068408011 AccuFlex 150 Single Use Holmium Laser Fiber 150 Micron Box/5<br />

M0068408020 AccuFlex 200 Single Use Holmium Laser Fiber 200 Micron Each<br />

M0068408021 AccuFlex 200 Single Use Holmium Laser Fiber 200 Micron Box/5<br />

M0068408030 AccuFlex 273 Single Use Holmium Laser Fiber 273 Micron Each<br />

M0068408031 AccuFlex 273 Single Use Holmium Laser Fiber 273 Micron Box/5<br />

M0068408040 AccuFlex 365 Single Use Holmium Laser Fiber 365 Micron Each<br />

M0068408041 AccuFlex 365 Single Use Holmium Laser Fiber 365 Micron Box/5<br />

M0068408050 AccuFlex 550 Single Use Holmium Laser Fiber 550 Micron Each<br />

M0068408051 AccuFlex 550 Single Use Holmium Laser Fiber 550 Micron Box/5<br />

M0068408060 AccuFlex 1000 Single Use Holmium Laser Fiber 1000 Micron Each<br />

M0068408061 AccuFlex 1000 Single Use Holmium Laser Fiber 1000 Micron Box/5<br />

*** “Performance and Safety of Holmium:YAG Laser Optical Fibers” by Bodo E. Knudsen et al, Journal of Urology, Vol. 171, No. 4,<br />

Supplement of Tuesday, May 11, 2004, Page 442, Abstract No. 1671.<br />

Black Hole is a trademark of InnovaQuartz, Inc.<br />

DUR-8 Elite is a trademark of ACMI Corporation<br />

Flex-X is a trademark of Karl Storz Endoscopy - America, Inc.<br />

The AccuFlex Fiber is manufactured by InnovaQuartz, Inc. and distributed in the U.S. exclusively by <strong>Boston</strong> <strong>Scientific</strong> Corporation.<br />

Caution: Federal Law (USA) restricts these devices to sale by or on the order of a physician.<br />

Refer to package insert provided with product for complete instructions for use including Indications for Use, Contraindications,<br />

Potential Complications, Warning and Cautions.<br />

<strong>Boston</strong> <strong>Scientific</strong> Corporation<br />

One <strong>Boston</strong> <strong>Scientific</strong> Place<br />

Natick, MA 01760<br />

www.bostonscientific.com/urology<br />

Ordering Information<br />

1.888.272.1001<br />

© 2006 <strong>Boston</strong> <strong>Scientific</strong> Corporation<br />

or its affiliates. All rights reserved.<br />

BVU2250 5M 02/06-02/08

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!