Connection to the cooling water circuit<br />

The pressure in the cooling water circuit must be<br />

limited by a pressure relief valve (e.g. radiator filler<br />

cap) to a maximum of 2 bars gauge pressure.<br />

There are four possibilities to do so:<br />

1. Using a thermostat in the supply line<br />

to the heater.<br />

Initially, the heat from the additional heater is<br />

supplied only to the driver’s cab up to a cooling<br />

water temperature of about 70 °C = small circuit,<br />

rapid heating.<br />

If the cooling water temperature rises further, the<br />

thermostat changes gradually (changeover<br />

completed at 75 °C) to the large circuit = additional<br />

engine preheating.<br />

Important!<br />

When operating with an additional heater, the<br />

heating valve must always be wide open.<br />

Recommendation:<br />

Use a switch with an N / C limit position contact for<br />

all heating circuits.<br />

Very important:<br />

Make the connections 1, 2 and 3 as shown in the<br />

sketch.<br />

Expansion Tank<br />

Flow only possible when<br />

engine is running<br />

Heater valve<br />

Thermostat, Ø 20 mm<br />

Order No. 330 00 124<br />

Radiator<br />

Radiator<br />

thermostat<br />

Water<br />

pump<br />

Engine<br />

t>75 °C<br />

Thermostat<br />

t75 °C<br />

Thermostat<br />

t