25.09.2014 Views

Download - Tech-Rentals

Download - Tech-Rentals

Download - Tech-Rentals

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

techrentals<br />

your rental business partner<br />

T E S T & M E A S U R E M E N T<br />

Rental Solutions Guide<br />

<strong>Tech</strong><strong>Rentals</strong><br />

volume 38 ● issue 18


Offi ce Locations<br />

<strong>Tech</strong><strong>Rentals</strong> Australia<br />

1800 632 652<br />

www.techrentals.com.au<br />

rent@techrentals.com.au<br />

Adelaide<br />

169 South Road<br />

Ridleyton<br />

South Australia 5008<br />

P 08 8302 8800 | F 08 8302 8899<br />

Melbourne<br />

6 Joseph Street<br />

Blackburn North<br />

Victoria 3130<br />

P 03 9896 3000 | F 03 9896 3099<br />

Sydney<br />

41 Enterprise Circuit<br />

Prestons<br />

New South Wales 2170<br />

P 02 8777 0800 | F 02 8777 0877<br />

Brisbane<br />

72 Donaldson Road<br />

Rocklea<br />

Queensland 4106<br />

P 07 3717 9100 | F 07 3077 8872<br />

Newcastle<br />

Unit 2, 1 Hartley Drive<br />

Thornton<br />

New South Wales 2322<br />

P 02 4966 5910 | F 02 4966 3586<br />

Townsville<br />

Unit 2, 14 Blackhawk Boulevard<br />

Thuringowa Central<br />

Queensland 4817<br />

P 07 4773 7788 | F 07 4723 5397<br />

Darwin<br />

Unit 3, 101 Coonawarra Road<br />

Winnellie<br />

Northern Territory 0820<br />

P 08 8947 2860 | F 08 8947 2901<br />

Perth<br />

122 Kewdale Road<br />

Kewdale<br />

Western Australia 6105<br />

P 08 9441 3900 | F 08 9441 3999<br />

<strong>Tech</strong><strong>Rentals</strong><br />

Malaysia<br />

603 5632 1135<br />

www.techrentals.com.my<br />

SELANGOR D.E<br />

38 Jalan PJS 11/3 Bandar Sunway<br />

46150 Petaling Jaya<br />

Selangor Darul Ehsan<br />

Malaysia<br />

P +60 3 5632 1135<br />

F +60 3 5632 5409<br />

<strong>Tech</strong><strong>Rentals</strong><br />

New Zealand*<br />

0800 832 475<br />

www.techrentals.co.nz<br />

AUCKLAND<br />

669 Great South Road<br />

Penrose Auckland<br />

New Zealand<br />

P +64 9 589 2030<br />

F +64 9 589 2031<br />

*distributor of <strong>Tech</strong><strong>Rentals</strong><br />

Australia<br />

TR VMS<br />

(Calibration - Repair - Sales)<br />

BRISBANE<br />

72 Donaldson Road<br />

Rocklea<br />

Queensland 4106<br />

P 07 3717 9100<br />

F 07 3717 9148<br />

SYDNEY<br />

41 Enterprise Circuit<br />

Prestons<br />

New South Wales 2170<br />

P 02 8777 0800<br />

F 02 8783 5171


Contents<br />

Why rental makes good sense General Index 2, 3 & 4<br />

1. stretch your budget<br />

Test equipment is often used just some of the time. Rental allows<br />

you to pay for it only when you use it, as well as stretching your<br />

budget by accessing more equipment than you could if you<br />

purchased it outright.<br />

2. utilise operating expense<br />

Test equipment is expensive often sitting on a shelf collecting<br />

dust – not an effective use of your valuable business capital.<br />

Rental allows you to free up cash for other parts of the business<br />

where it can be used to generate additional profi ts.<br />

3. conduct product research before purchasing<br />

It is not always clear immediately which make and model will fulfi l<br />

your requirements best. Trialling it on casual rental gives you<br />

hands-on experience to guide purchase decisions.<br />

4. recover costs more quickly<br />

Generally rental payments are fully tax deductable and the<br />

expense can be recovered far more quickly than the tax<br />

allowances for ongoing asset depreciation. †<br />

5. eliminate running costs<br />

The expense of maintaining, calibrating and warehousing your<br />

test and measurement equipment can be high. With rental you<br />

avoid these costs, as well as freeing up storage space within your<br />

premises.<br />

6. cost allocation is simplified<br />

Rental payments are easy to track and account for in your<br />

business, making it easy to allocate appropriate costs to<br />

departments, clients or specifi c projects.<br />

7. respond to sudden demands<br />

At peak periods, for unexpected projects, or when essential<br />

equipment breaks down, rental can put the necessary equipment<br />

in your hands ensuring seamless operations.<br />

8. apply new technologies & avoid obsolescence<br />

Rental allows you to update your equipment in line with other<br />

businesses and take advantage of new technologies. It also<br />

avoids the potential cost of owning equipment that can be quickly<br />

superseded.<br />

9. preserve credit<br />

Renting avoids the potential cost of utilising credit facilities<br />

such as an overdraft or credit cards, which are often used for<br />

equipment purchases.<br />

10. technical support<br />

When you rent from <strong>Tech</strong><strong>Rentals</strong> you’ll have the support of an<br />

experienced team of product experts, who’ll help you get the most<br />

from your equipment. And in the unlikely event of equipment failure<br />

we will do our utmost to rectify the issues as soon as possible.<br />

Manufacturers Index 5, 6 & 7<br />

Electronics 8 - 11<br />

Radio Frequency 12 -19<br />

Data &<br />

Telecommunications 20-25<br />

Electrical Power 26-41<br />

General Industrial & Process<br />

Measurement 42 - 55<br />

Physical Measurement 57 - 61<br />

Construction, Building<br />

Services & Survey 62 - 66<br />

Environmental, OHS,<br />

Chemical & Laboratory 67 - 74<br />

Other Products 75<br />

Save your time and reduce<br />

your real costs. Find out all<br />

about our Confi guration and<br />

<strong>Download</strong> solutions on page 43.<br />

Visit <strong>Tech</strong><strong>Rentals</strong> Wiki<br />

This resource centre provides manuals,<br />

technical information and how-to videos.<br />

www.techrentals.com.au<br />

select <strong>Tech</strong>nical Tips and Videos.<br />

†<br />

Please ensure you obtain independent professional taxation advice.<br />

Your trusted partner in<br />

technology. Offering<br />

innovative solutions through<br />

our leading brands: techrentals hirecom vidcom telecom<br />

1


General Index<br />

A<br />

AC See Electrical Power<br />

AC Sources/Inverters/Generators 39<br />

Accelerometer 60<br />

Adhesion Tester 57<br />

Air<br />

Flow 62, 63, 69<br />

Quality 62, 63, 69<br />

Air Balancing Hood 62, 63<br />

Air Conditioner Valve Balancing 63<br />

Air Conditioning<br />

Coolant Flow 74<br />

Electronic Manifold 63<br />

Measurement 62<br />

Valve Balancing 63<br />

Air Conditioning & Air Flow 62<br />

Air Quality<br />

Monitoring 62, 67, 68, 69<br />

Particles 68, 69<br />

Pressure & Humidity 62, 69<br />

Air Quality & Heat Stress 69<br />

Airborne Dust & Particle Meter 68<br />

Alignment 46, 60<br />

Anemometers 62, 63<br />

Antenna & Cable Test 14, 16<br />

Antennas 19<br />

Appliance Tester 27<br />

Area Air Quality 67<br />

Area Heat Stress 69<br />

Audio Analysers 16<br />

B<br />

Balances 60, 74<br />

Balances & Scales Below 8kg 74<br />

Balancing Machinery 63<br />

Balometers 62, 63<br />

Barometric Loggers 73<br />

Bath<br />

Constant Temperature 46<br />

Ultrasonic 55<br />

Battery Management Systems 40<br />

Blast Loggers 60, 61<br />

Body Vibration Measurement 60, 61<br />

Bore Hole Water Quality 71, 72, 73<br />

Borescopes 45<br />

Bridge LCR 9<br />

C<br />

Cable<br />

Fault Locator 26<br />

LAN Test 20<br />

Locator 20, 26, 65<br />

Tester 20<br />

Cable & Fault Locator 65<br />

Cable & Pipe Tracers & Fault Locators 26, 65<br />

Cable Locators 65<br />

Calibrators<br />

Current 10, 46, 50<br />

Current Loop 10, 46, 48, 49, 50<br />

Dry Block Temperature 46,50<br />

Fitting Set 48<br />

Hydraulic 46, 47, 48, 50<br />

Industrial 46, 50<br />

Intrinscially Safe Loop 48<br />

Laboratory 10, 49<br />

Loop 46, 50<br />

Pneumatic Instruments 46, 47, 50<br />

Pressure 46, 47, 48, 49, 50<br />

Process 46, 48, 49, 50<br />

Resistance 10, 46, 48, 49, 50<br />

Temperature 46, 49, 50<br />

Voltage 10, 46, 48, 49, 50<br />

Caliper 59<br />

Camera<br />

Endoscope 45<br />

High Speed 45<br />

Pipe Inspection 45, 66<br />

Surveillance 75<br />

Thermal Imaging 43, 44<br />

Video 45<br />

Carbon Dioxide (CO 2<br />

) 55, 67, 69<br />

Carbon Monoxide & Nitrogen Dioxide Monitors 67<br />

Carbon Monoxide (CO) 55, 67, 68, 69<br />

Cat 5, 5E, 6 20<br />

Charge Amplifi er 60<br />

Chart Recorders 50, 53<br />

Chemical & Analytical 74<br />

Circuit Breaker Analysers 39<br />

Circuit Tracers 26<br />

Clamp-on Sensors 33<br />

Clean Room Monitor 68<br />

Cleaver - Fibre Optic 23<br />

Coating Thickness 57, 59<br />

Combustion Gas Analysis 55<br />

Combustion, Flue & Industrial Gas Analysers 55<br />

Communication Test Sets 16<br />

Compressor Output<br />

Flow 69<br />

Quality 69<br />

Concrete Cover Meters 64<br />

Concrete Hardness Tester 64<br />

Concrete Testing<br />

Adhesion 57<br />

Corrosion 64<br />

Cover Meters 64<br />

Moisture Meter 64, 66<br />

Reo Depth 64<br />

Test Hammer 64<br />

Concrete Testing Equipment 64<br />

Conductivity & Salinity 73<br />

Conductivity Probes 72<br />

Confi ned Space Entry 67, 68<br />

Construction, Building Services & Survey 62-66<br />

Air Conditioner Valve Balancing 63<br />

Air Conditioning & Air Flow 62<br />

Concrete Testing Equipment 64<br />

Distance Measurement & Surveying 66<br />

Ground Penetrating Radar 65<br />

Material Moisture Meters 66<br />

Pipeline & Cavity Inspection 66<br />

Underground Services Location 65<br />

Utility Leak Detection 65<br />

Counting Scales 60, 74<br />

Crane Scales 60<br />

Current<br />

Clamp 32, 33, 34, 35, 39<br />

DC Source 9<br />

Injection 38<br />

Input Logger 52<br />

Loop 46, 49, 50<br />

Meters 32, 33, 34, 54, 74<br />

Primary Injection 38<br />

Probes 9, 26, 33, 34, 35<br />

Secondary Injection 38<br />

Transducer 35<br />

Transformer (CT) 33<br />

Current Clamps Probes & Accessories 33, 34, 35<br />

Current Injectors 38<br />

Current Transformer Testing 38<br />

D<br />

Data & Telecommunications 20<br />

Cable Test 20<br />

DSL/POTS Test Set 22<br />

Ethernet Analysers 20<br />

Ethernet Loopback 20<br />

Ethernet Test Set 20<br />

Etherscope 20<br />

Fibre Optic Launch Cables & Patch Leads 24<br />

Fibre Optics 24<br />

Fusion Splicers 23<br />

LAN Analysers 20<br />

LAN Cable Testers 20<br />

LAN/WAN Analysers 20<br />

Light Source 22, 23<br />

Light Sources & Power Meters 22, 23<br />

OTDR & Fibre Inspection 23<br />

PDH/SDH Analysers 21<br />

Permanent Link Adaptors 20<br />

WAN Analysers 20<br />

Data Loggers 52, 53<br />

DC High Voltage 9, 33, 34, 35, 36<br />

DC Power Supplies 9, 10<br />

DC Power Supplies & Loads 9, 10<br />

Decade Resistance Box 10, 49<br />

Demand Analysers 29<br />

Dewpoint 69<br />

Digital Storage Oscilloscopes 8, 9<br />

Dimension Measurement 59<br />

Dissolved Oxygen 72<br />

Distance Measurement & Surveying 66<br />

Distortion Analysers 16<br />

Dry Block Calibrators 50<br />

DSL/POTS 22<br />

DSn/PDH Ethernet Analyser 22<br />

Ductor 27, 29<br />

Dust Measurement 68, 69<br />

E<br />

E & H Field Strength Meters 10, 11<br />

E1/E3 Tester 21, 22<br />

Earth Leakage 27, 35, 36, 37<br />

Earth Testers 27<br />

Electrical Cable Test 27, 35, 36, 37<br />

High Voltage 36<br />

Surge Generator 26<br />

TDR 26<br />

VLF 36<br />

Electrical Installation & Test<br />

Appliance Tester 27<br />

Earth Leakage (RCD) 27, 35, 36, 37<br />

High Voltage Test (Hipot) 36<br />

Insulation Oil Testers 36<br />

Insulation Test 26, 27, 35, 36, 37<br />

Resistance Test 27, 29, 35<br />

Soil/Ground Resistance 27, 29<br />

VLF Testers 36<br />

Electrical Power 26<br />

AC Sources/Inverters/Generators 39<br />

Battery Management Systems 40<br />

Cable & Pipe Tracers & Fault Locators 26<br />

Current Clamps Probes & Accessories 33<br />

Current Injectors 38<br />

Electrical Testers 26<br />

Insulation Testers & Meggers to 20kV 35<br />

Micro-Ohm Meters & Earth Testers 27<br />

Oil, Hipot & VLF Testers above 20kV 36<br />

PAT Testers & RCD Testers 27<br />

Power Analysers & Recorders 29<br />

Power Line Conditioners/UPS 40<br />

Power Transformer Testers 37<br />

Power Transformers 40<br />

Protection Relay Testing Systems 38<br />

Electrical Power Generation & Transmission<br />

Current Injection 38<br />

High Voltage Test (Hipot) 36<br />

Power Quality 26, 29, 30, 32, 33<br />

Protection Relay Test 38, 39<br />

VLF Test 36<br />

Electrical Power Quality<br />

Harmonics 26, 29, 33<br />

Power Factor 26, 29, 33<br />

Power Logger 32<br />

Power Quality Analysers 29, 30, 32, 33<br />

Electrical Power Sources<br />

Battery Management Systems 40<br />

Current Injectors 38<br />

Generators 39<br />

Line Conditioners 40<br />

Programmable 39<br />

UPS 40<br />

Electrical Testers 26, 27<br />

Electrical Transducers 26<br />

Electrochemistry 71<br />

Electrometers 8<br />

Electronic Load 9<br />

Electronics 8<br />

DC Power Supplies & Loads 9<br />

Digital Storage Oscilloscopes 8<br />

E & H Field Strength Meters 11<br />

EMC & Power Disturbance Simulators 11<br />

Function Generators 9<br />

Gauss/Tesla Meters 10<br />

Laboratory Calibrators 10<br />

LCR Meters 9<br />

Logic Analysers/PROM Programmers 10<br />

Multimeters& Electrometers 8<br />

Probes & Accessories 9<br />

Spectrum Analysers - Low Frequency 10<br />

TV Test Equipment 10<br />

Electrostatic Charge Measurement 8<br />

Electrostatic Meter 8<br />

EMC & Power Disturbance Simulators 11<br />

EMC Test Equipment 11<br />

EMC/EMI Test Equipment 11<br />

Endoscopes 45, 66<br />

Endoscopes Borescopes Visual Inspection 45<br />

Environment, OHS, Chemical & Laboratory 67<br />

Air Quality & Heat Stress 69<br />

Airborne Dust & Particle Meters 68<br />

Balances & Scales below 8kg 74<br />

Chemical & Analytical - General 74<br />

Enviornmental Gas & Vapour Meters 67<br />

Environment Flow Meters 74<br />

Floor Slip Testers 71<br />

Laboratory Instruments, Spectroscopy 74<br />

Light Meters, UVA/B/C Measurement 73<br />

Moisture & Humidity Meters 69<br />

Noise & Sound Analysers 70<br />

Personal Gas & Vapour Monitors 68<br />

2


General Index cont’d.<br />

Radiation Monitoring & Protection 71<br />

Water Quality, pH Meters & Electrochem 71<br />

Weather Stations 73<br />

Environmental Chambers/Oven 55<br />

Environmental Flow Meters 74<br />

Environmental Gas & Vapour Meters 67<br />

Environmental Noise 70<br />

Environmental Noise Loggers 70<br />

Environmental Test Chambers/Ovens 55<br />

Ethernet Loopback 20<br />

Ethernet Test Set 20<br />

Excavator Cable Locator 65<br />

F<br />

Fault Locator 26, 65<br />

Fault Loop Impdenace Tester 27<br />

Fibre Inspection & Test Kit 24<br />

Fibre Inspection-Capture Probe 24<br />

Fibre Optic Launch Cables & Patch Leads 24<br />

Fibre Optics 24<br />

Fusion Splicers 23<br />

Cleaver 23<br />

Fibrescope 66<br />

Field Strength Meters 10, 11<br />

Flash Card 50, 52<br />

Flaw Detector 57<br />

Floor Slip Testers 71<br />

Flow Hood 62, 63<br />

Flow Meters 54, 55, 74<br />

Compressed Air 54<br />

Doppler 54, 55<br />

Gas 54<br />

Liquid 54, 55, 74<br />

Non-Intrusive 54, 55<br />

Open Channel 54, 74<br />

Transit Time 54, 74<br />

Ultrasonic 54, 55, 74<br />

Flow Meters for Liquids & Gases 54<br />

Flue Gas Analysis 55<br />

Flue Inspection 45, 66<br />

Force Gauges 59<br />

Formaldehyde Meter 67<br />

Frequency Counters 12<br />

Frequency Response Analysers 38<br />

Function Generators 9<br />

Fusion Splicers 23<br />

G<br />

Gamma Radiation 71<br />

Gas 67<br />

Carbon Dioxide (CO 2<br />

) 55<br />

Carbon Monoxide (CO) 55<br />

Flammable (LEL) 67, 68<br />

Formaldehyde 67<br />

Hydrogen Sulphide (H 2<br />

S) 67, 68<br />

Methane (CH 4<br />

) 67<br />

Nitric Oxide (NO) 55<br />

Nitrogen Dioxide (NO 2<br />

) 55<br />

Oxygen (O 2<br />

) 55, 67<br />

Ozone (O 3<br />

) 67<br />

Refrigerant 67<br />

SF6 68<br />

Sulphur Dioxide (SO 2<br />

) 67<br />

VOC 68<br />

Gas & Vapour Meters 67<br />

Gas Analysis & Monitoring 55, 67, 68<br />

Gauss/Tesla Meters 10, 11<br />

General Industrial & Process Measurement 42<br />

Combustion, Flue & Industrial Gas Analysers 55<br />

Data Loggers 52<br />

Dry Block Calibrators 50<br />

Endoscopes Borescopes Visual Inspection 45<br />

Environmental Test Chambers/Ovens 55<br />

Flow Meters for Liquids & Gases 54<br />

High Speed Video Inspection Cameras 45<br />

High Speed Waveform Recorders 50<br />

Industrial Process Calibrators 46<br />

Infrared Thermal Imaging Cameras 43<br />

Laser Rotational Shaft Alignment 46<br />

Pressure & Humidity Transducers 53<br />

Pressure Vacuum Gauges/Recorders 53<br />

Strip Chart Recorders 50<br />

Tachometers/Stroboscopes 46<br />

Temperature Meters/IR Thermometers 42<br />

Ultrasonic Baths 55<br />

Generator (AC) 39<br />

Ground Penetrating Radar 65<br />

H<br />

Hardness Testers 57<br />

Harmonics (Power) 29, 30, 33<br />

Hart Communicators 48<br />

Heat Stress 69<br />

High Frequency Spectrum Analysers 12, 14<br />

High Speed Video Cameras 45<br />

High Speed Video Inspection Cameras 45<br />

High Speed Waveform Recorders 50<br />

High Voltage Insulation DielectricsTest Set 36, 37<br />

Hipot Testers 36<br />

Holiday Detector 57<br />

Hot Wire Anemometer 62, 63<br />

Humidity<br />

Chamber 55<br />

Concrete 64<br />

Indoor Air 69<br />

Logging 52, 53<br />

Natural Gas 69<br />

Thermohygrograph 69<br />

Transducers 53<br />

Weather 73<br />

HVAC & IAQ 62, 63, 69<br />

Hybrid Recorders 50<br />

Hydraulic Pressure 46, 47, 48, 57<br />

I<br />

Illuminance Meter 73<br />

Inclinometers 59<br />

Indoor Air Quality 69<br />

Industrial Process Calibrators 46, 50<br />

Infrared Cameras 43, 44<br />

Infrared Thermal Imaging Cameras 43<br />

Infrared Thermometers 42<br />

Injection Test Set 38<br />

Instrumentation Amplifi er 50<br />

Insulation Testers 27, 35<br />

Insulation Testers & Meggers to 20kV 35, 36<br />

Intrinsically Safe<br />

Current Loop Calibrator 46<br />

Digital Multimeter 8<br />

Gas Monitor 67, 68<br />

Moisture Analyser 69<br />

Photo-Ionisation Detector (PID) 68<br />

IR Thermometers 42<br />

L<br />

Laboratory Calibrator 10, 49<br />

Laboratory Oven 55<br />

LAN<br />

Analysers 20<br />

Cable Certifi cation 20<br />

Cable Testers 20<br />

LAN Analysers/Management 20<br />

LAN Cable Testers 20<br />

LAN/WAN Analysers 20, 21<br />

Landfi ll Gas Monitor 67<br />

Laser<br />

Distance & Speed 61, 66<br />

Laser Pipe Alignment System 46<br />

Laser Rotational Shaft Alignment 46<br />

LCR Meters 9<br />

Leak Detectors<br />

Gas Pipe 65, 67, 68<br />

Microwave Oven 71<br />

Refrigerant 67<br />

Water 65<br />

Light Measurement 66, 73<br />

Light Meters, UVA/B/C Measurement 73<br />

Light Source 22, 23<br />

Light Sources & Power Meters 22, 23<br />

Linear Position Transducers 59<br />

Liquid Flow Logger 74<br />

Liquid Flow Meters 54<br />

Load Cells 59, 60<br />

Loggers<br />

Accessories 52<br />

Autoclave 52<br />

Data 52, 53<br />

Explosion 60, 61<br />

Flow 54<br />

Humidity 52, 53<br />

Temperature 52, 53<br />

Loggers<br />

See also Recorders<br />

Logic Analysers 10<br />

Logic Analysers/PROM Programmers 10<br />

Logic Programmer 10<br />

Low Frequency Spectrum Analysers 10<br />

Luminance Meter 73<br />

Lux Meter 73<br />

M<br />

Machinery<br />

Balancing 60<br />

Vibration 60, 61<br />

Magnetic Field Meter 10, 11<br />

Manometer 62, 63<br />

Material Hardness Testers 57<br />

Material Moisture Meters 66<br />

Material Testing 74<br />

Memory Recorders 50, 51, 52<br />

Metal Detectors 75<br />

Methane Monitor 67<br />

Micrometers 59<br />

Micro-Ohm Meters & Earth Testers 27, 29<br />

Microwave Leakage Detector 71<br />

Microwave Oven Survey Meter 71<br />

Modifi ed Atmosphere<br />

Packaging Test 55, 67<br />

Moisture<br />

Concrete 64, 66<br />

Timber 66<br />

Wood 64<br />

Moisture & Humidity Meters 69<br />

Moisture Analysers 69<br />

Moisture Balance 74<br />

Multimeter 8<br />

Multimeters & Electrometers 8<br />

N<br />

Natural Gas 69<br />

Network Analyser<br />

Antenna & Cable Test 14, 16<br />

Cable Test 14<br />

Power 29, 33<br />

RF 14<br />

Network Analysers 14<br />

Network Analysers/Antenna & Cable Test 14<br />

Noise & Sound 70<br />

Noise & Sound Analysers 70<br />

Noise Loggers 70<br />

Non-Destructive Testing (NDT) 57, 59<br />

O<br />

Occupational Health & Safety 67<br />

Air Quality 62, 63, 69<br />

Appliance Testing 27<br />

Confi ned Space Entry 67, 68<br />

Floor Slip Testers 71<br />

Formaldehyde 67<br />

Heat Stress 69<br />

Lighting 73<br />

Noise & Sound 70<br />

Ozone 67<br />

Radiation 11, 71<br />

UV Exposure 73<br />

Vibration 60<br />

Volatile Organic Compound 67<br />

Oil Insulation Testers 36, 37, 38<br />

Oil, Hipot & VLF Testers Above 20kV 36<br />

Oscilloscopes<br />

Digital Storage 8, 9<br />

Portable 8<br />

OTDR 23, 24<br />

OTDR & Fibre Inspection 23, 24<br />

Other Products<br />

Prospecting Metal Detectors 75<br />

Security Equipment 75<br />

Oven 55<br />

Oxygen & CO 2<br />

Analyser 55, 67, 68<br />

Oxygen (O 2<br />

) 55, 67, 68<br />

Ozone (O 3<br />

) 67<br />

P<br />

Pancake Load Cell 60<br />

Particle Counters 68, 69<br />

PAT 27<br />

PAT Testers & RCD Testers 27<br />

PDH Analysers 21, 22<br />

PDH/SDH Analysers 21<br />

Pen Plotter 9<br />

Permanent Link Adaptors 20<br />

Personal Gas & Vapour Monitors 68<br />

pH Measurement 71, 72<br />

pH Meters 71<br />

pH Reading for Meat Standards 72<br />

pH, mV & Temperature Measurement 72<br />

Photo-Ionisation Detector (PID) 67, 68<br />

Physical Measurement<br />

Force Gauges 59<br />

Inclinometers 59<br />

Load Cells 59<br />

Material Hardness Testers 57<br />

Micrometers 59<br />

Non-Destructive Testing 57<br />

3


General Index cont’d.<br />

Physical Measurement<br />

Position Transducers 59<br />

Speed Measurement 61<br />

Vibration Analysis 60<br />

Weighing & Counting Scales Over 8kg 60<br />

Pinhole Detector 57<br />

Pipe Locator 65<br />

Pipeline & Cavity Inspection 66<br />

Pipeline Camera Inspection System 66<br />

Pipeline Inspection 45<br />

Pitot Tube 62<br />

Plotter 9<br />

Pobes & Accessories 9<br />

Portable Appliance Testers 27<br />

Position Transducers 59<br />

POTS 22<br />

Power<br />

See Electrical Power<br />

Power Analysers 29, 33<br />

Power Analysers & Recorders 29, 30, 33<br />

Power Demand Analysers 29<br />

Power Disturbance 26, 27, 29, 33<br />

Power Line Conditioners 40<br />

Power Line Conditioners/UPS 40<br />

Power Loggers 32, 34<br />

Power Meter - RF 16, 17<br />

Power Meters 16, 17<br />

Power Meters & Sensors 17<br />

Power Supplies - DC 9, 10<br />

Power Transformer Testers 37<br />

Power Transformers 40<br />

Pressure<br />

Calibrators 46, 47, 48, 49, 50<br />

Circular Chart Recorders 53<br />

Indicator/Gauges 53<br />

Logging Gauges 53, 54<br />

Transducers 53<br />

Pressure & Humidity Transducers 53<br />

Pressure Calibrators 48<br />

Pressure Recorders 50<br />

Pressure Transducers 48<br />

Pressure Vacuum Gauge/Recorders 53, 54<br />

Probes<br />

Current 9, 26, 33, 34, 35, 39<br />

High Voltage 9<br />

Line Logic 51<br />

Process Calibrators 48, 49, 50<br />

Profi bus 48<br />

Programmer<br />

EPROM, EEPROM 10<br />

PROM Programmers 10<br />

Prospecting Metal Detectors 75<br />

Protection Relay Test 38, 39<br />

Protection Relay Testing Systems 38, 39<br />

Pulse Porosity Detector 57<br />

Pumps 46, 47, 48, 49<br />

R<br />

Radar Speed Gun 61<br />

Radiation Monitor 11, 71<br />

Radiation Monitoring & Protection 71<br />

Radiation Monitors 71<br />

Radio Frequency 12<br />

Antenna/SWR 14, 16, 19<br />

Communication Test Sets 16<br />

Distortion Analysers 16<br />

Frequency Counters 12<br />

Network Analysers/Antenna & Cable Test 14, 16<br />

Power Meters - RF 16, 17<br />

Power Sensors 17<br />

RF Accessories 19<br />

RF Amplifi ers 17<br />

RF Attenuators 17, 19<br />

RF Signal & Sweep Generators 12<br />

Spectrum Analysers - High Frequency 12<br />

Radiometer 73<br />

RCD Test 27, 35<br />

Recorders 52<br />

Chart 50<br />

Hybrid 50<br />

Memory 50, 51, 52<br />

Pressure 50, 53<br />

Refrigerant Leak Detection 67<br />

Relay Test 37, 38, 39<br />

Resistance<br />

Calibration 10, 46, 49, 50<br />

Decade 10, 49<br />

Ground/Soil 27, 29<br />

Micro-Ohm 27, 29<br />

Static 35<br />

Tester 27, 35, 36, 37<br />

RF<br />

See also Radio Frequency<br />

RF Accessories 19<br />

RF Amplifi ers 17<br />

RF Attenuators 17, 19<br />

RF Signal & Sweep Generators 12<br />

RF Sweep Generators 12<br />

Rotating Balancing 60, 61<br />

Roughness 57<br />

RTD Calibrator 46<br />

S<br />

Safety Bolt Inspection System 59<br />

Salinity & Conductivity 72, 73<br />

Scales 60, 74<br />

Scanning Receiver 16<br />

Scopemeter 8<br />

SDH Analysers 21<br />

Security<br />

Metal Detectors 75<br />

Surveillance 75<br />

Security Equipment 75<br />

Sensors - RF 16, 17<br />

Shaft Alignment 46, 60<br />

Shaker Table 60<br />

Signal Generators 12<br />

RF 12<br />

Smoke Generating Machine 62<br />

Soil Resistivity 27, 29<br />

Sonde 65<br />

Sound<br />

Dose Meter 70<br />

Measurement 70<br />

Signal Analysis 70<br />

Sound Level Meter 60, 61, 70, 71<br />

Vibration 60, 61<br />

Spectrophotometer 74<br />

Spectroscopy 74<br />

Spectrum Analysers<br />

High Frequency 12, 14<br />

Low Frequency 10<br />

RF 10, 12, 14<br />

Spectrum Analysers – Low Frequency 10<br />

Spectrum Analysers – High Frequency 12<br />

Speed Measurement 61<br />

Splicer - Fibre Optic 23<br />

Startup Current 32, 33, 34, 35<br />

Static Discharge Generator 11<br />

STM1 ... STM64 21, 22<br />

Strip Chart Recorders 50<br />

Stroboscopes 46<br />

Surface Roughness 57<br />

Surge Generator 26<br />

Surge Transient Generator<br />

EMC/EMI Test 11<br />

Sweep Generators 12<br />

T<br />

Tachometers 46<br />

Tachometers/Stroboscopes 46<br />

Tan Delta Measurement 36, 37<br />

TDR 26<br />

Telecommunications 20, 21<br />

Access Tester 21<br />

Analysers 20, 21, 22<br />

CDMA 17<br />

PDH 21<br />

POTS 22<br />

SDH 21<br />

Temperature<br />

IR Thermometers 42<br />

Logging 52<br />

Probes 42<br />

Thermocouples 42<br />

Thermometers 42, 43<br />

Temperature Bath 50<br />

Temperature Meters 42<br />

Temperature Meters/IR Thermometers 42<br />

Tension 59<br />

Test & Tagging 27<br />

Test Chambers 55<br />

Thermal Imaging Camera 43, 44<br />

Thermocouples 42<br />

Thermohygrograph 69<br />

Thickness Gauge 57<br />

Time Domain Refl ector 26<br />

TDR 26<br />

Torque Wrench 59<br />

Total Dissolved Solids (TDS) 72, 73<br />

Tracking Generator 12<br />

Transducers<br />

Current 35<br />

Electrical 26<br />

Humidity 53<br />

Position 59<br />

Pressure 53<br />

Temperature 53<br />

Transformer Oil Test 38<br />

Transient Burst 11<br />

Transport<br />

Inclinometers 59<br />

Turbidity 71, 73<br />

TV Test Equipment 10<br />

U<br />

Ultrafi ne Particle Counters 68, 69<br />

Ultrasonic Baths 55<br />

Ultrasonic Probes 57<br />

Underground Services Location 65<br />

Uninterruptable Power Supplies - UPS 40<br />

USB to RS232 Converter 9<br />

Utility Leak Detection 65<br />

UV Exposure 73<br />

V<br />

Valve Balancing (Air Conditioning) 63<br />

Variacs 40<br />

Ventilation Meter 63<br />

Vibration<br />

Accelerometer 60<br />

Analyser 60, 61<br />

Blast Logging 60, 61<br />

Impact Hammer 60<br />

Table 60<br />

Whole Body 60<br />

Vibration Analysis 60<br />

Vibration Loggers 61<br />

Video<br />

Endoscope 45<br />

High Speed 45<br />

Pipeline Inspection 45, 66<br />

Video Security 75<br />

Viscometer 74<br />

Visual Inspection 45, 66<br />

Visual Inspection Equipment 45, 66<br />

VLF MV Cable Test 36<br />

VOC Monitor 67<br />

Volatile Organic Compound (VOC) 67, 68<br />

Voltage Calibrator 46, 50<br />

W<br />

Walk Through Metal Detector 75<br />

WAN Analysers 20<br />

Water<br />

Analysis 71<br />

Conductivity 72, 73<br />

Depth 54, 71, 72, 73, 74<br />

Depth Measurement 72<br />

Flow 54, 55, 74<br />

pH 71, 72<br />

Quality 71, 72<br />

Sampling 72<br />

Water Quality, pH Meters & Electrochem 71<br />

Water/Oil Bath Temperature Calibrator 46<br />

Water/Oil Temperature Bath 50<br />

WBGT 69<br />

Weather 73, 74<br />

Weather Stations 73<br />

Weighing & Counting Scales Over 8kg 60<br />

Wind Speed & Direction 63, 73, 74<br />

Wind Turbine Lightning Protection Test Lead Set 29<br />

Winding Transformer Meter 37<br />

Wood & Masonry Testing<br />

Moisture Meter 64<br />

Workplace Safety<br />

See Envivonmental, OH&S, Chemical & Laboratory 67<br />

X<br />

X-Ray Measurement 71<br />

4


Manufacturers Index<br />

ABACUS<br />

ABA,301 68<br />

ACTERNA<br />

ACT,MTS8000 22<br />

ACT,OLA-55 22<br />

ADVANTEST<br />

ADV,TR1720 19<br />

ADV,U3771 12<br />

AERQUAL<br />

AER,500L 67<br />

AGILENT<br />

(Also see Hewlett-Packard)<br />

AGI,53151A 12<br />

AGI,MSO6104A 8<br />

AGI,MSOX3024A 8<br />

AGI,N9340A-TG 12<br />

AGI,N9912A 14<br />

AH SYSTEMS<br />

AH,ANTENNA 19<br />

AH,SAS-200/550 19<br />

AH,SAS-200/571 19<br />

AH,SAS-571 19<br />

AIC<br />

AIC,SG-AST-500 59<br />

AIRMAGNET<br />

AIR,AIRMAG SPEC AN 12<br />

AIRFLOW<br />

AIR,AV2 62<br />

AIR,AV2-NATA 62<br />

AIR,PITOT-36 62<br />

ALNOR<br />

ALN,EBT-721-A3 62<br />

ALN,EBT-721-Z3 62<br />

AMETEK<br />

AME,CADET-25N 59<br />

AME,HL2700N 46<br />

AME,PPCE 46<br />

A&D MERCURY<br />

AND,FC-10K 60<br />

AND,FG-150KB 60<br />

AND,FS-15KA 60<br />

AND,HF-300G 74<br />

AND,HP-40KA 60<br />

AND,MX50 74<br />

ANRITSU<br />

ANR,50-30-18 17<br />

ANR,ANTENNA 19<br />

ANR,CMA4000SM 23<br />

ANR,CMA4500SM-MM 23<br />

ANR,CMA5000SM-45 24<br />

ANR,MA2104A 17<br />

ANR,MS2711A 12<br />

ANR,MS2711D 14<br />

ANR,MS2711D-31-25 14<br />

ANR,MS2721A 14<br />

ANR,MT9083B 24<br />

ANR,S331D 14<br />

ANR,S331E 14<br />

ANR,S332D 14<br />

ANR,S332E 16<br />

ANR,S332E-CMAP-MOD 16<br />

ANR,S820D 16<br />

ANR,WAVEGUIDE-ADAP 16<br />

TELEWAVE<br />

ANT,DIRECTIONAL YAGI 19<br />

VARIOUS MANUFACTURERS<br />

ANT,OMNIDIRECTIONAL 19<br />

APP-TEK<br />

APT,ODA6000CP 67<br />

AQUA<br />

AQU,SNAKEEYE3 66<br />

ARCHOS<br />

ARC,AV500 66<br />

ARL<br />

ARL,EL-315 70<br />

ARL,EL-316 70<br />

ARL,NGARA 70<br />

ATLAS<br />

ATL,TCS-60 60<br />

AVO<br />

AVO,PENTA-PLUS-DMM 26<br />

BARLO<br />

BAR,MTC-150 59<br />

BAR,STC-10000 59<br />

BAR,STC-25000 59<br />

BAR,STC-500NATA 59<br />

BAUR<br />

BAU,DPA75 37<br />

BEAMEX<br />

BEA,MC5 46<br />

BEA,MC5-IS 47<br />

BEA,MC6 47<br />

BEA,PUMPS 47<br />

FW BELL<br />

BEL,4190 10<br />

BEL,5180 11<br />

BIDDLE<br />

BID,550005 37<br />

BIRD<br />

BIR,43 17<br />

BIR,ELEMENT-HF 17<br />

BIR,ELEMENT-LF 17<br />

BRUEL & KJAER<br />

BK,2237A 70<br />

BK,2238E-NATA 70<br />

BK,2239A-NATA 70<br />

BK,4448-IS-3KIT 70<br />

BK,8202 60<br />

BLASTRONICS<br />

BLA,UMX-SM-6 60<br />

HONEYWELL BW<br />

BW,BUMP 68<br />

BW,GA-SPAK 68<br />

BW,MICROCLIP 68<br />

CABLE DETECTION<br />

CAB,EZIDIG 65<br />

DVMR<br />

CAM,DVMR-4C 75<br />

CASIO<br />

CAS,EX-F1 45<br />

CASELLA CEL<br />

CAS,MICROTHERM 69<br />

CATU<br />

CAT,CL-8-36 PH STICK 26<br />

CCI<br />

CCI,POWER-MATE 15A 29<br />

CHAUVIN ARNOUX<br />

CHA,PROBE-I 9<br />

GRIDSENSE<br />

CHK,CK1 33<br />

CHK,CK5 33<br />

CHK,CR100 33<br />

CHK,CR500 33<br />

CHK,CT1000L 33<br />

CHK,CT3000L 33<br />

CHK,LM05 27<br />

CHK,PM20 30<br />

CHK,PM30 30<br />

CHK,PM30PLUS 30<br />

CHK,PM35 30<br />

CHK,PM40PQA 30<br />

CHK,PM45 30<br />

CHROMA<br />

CHR,61501 PAC-PS 39<br />

COM-POWER CORPORATION<br />

COM,AH-118 19<br />

SANDISK CORPORATION<br />

COM,FLASH512MB 50<br />

COM,FLASH64MB 52<br />

CRYSTAL ENGINEERING<br />

CORPORATION<br />

CRY,NVISION-30-NATA 47<br />

CRY,XP21-100-NATA 53<br />

CRY,XP21-300-NATA 53<br />

CRY,XP2I CAL KIT 1 47<br />

CRY,XP2I CAL KIT 345 47<br />

CRY,XP2I CAL KIT 7 47<br />

CRY,XP2I-10K-NATA 54<br />

CRY,XP2I-1K-NATA 54<br />

CRY,XP2I-3K 54<br />

CRY,XP2I-3K-NATA 54<br />

CSCOPE INTERNATIONAL<br />

CSC,CATXDSGA-KIT 65<br />

CSC,CATXDSGV-KIT 26<br />

CSC,CATXDSGV-KIT 65<br />

CONCEPT SMOKE SYSTEMS<br />

CSS,COLT4 62<br />

DATATAKER<br />

DE,CANGATE 52<br />

DE,DT600 52<br />

DE,DT80 52<br />

DE,DT800 52<br />

DE,DT80M 52<br />

DE,DT85 52<br />

DEFELSKO CORPORATION<br />

DEF,FNS2 57<br />

DEF,POS-200ADV 57<br />

DEF,POSITEST 57<br />

DETEC<br />

DET,DH-50-KIT4 75<br />

DILLION<br />

DIL,ED2000-5K 60<br />

DKK<br />

DKK,RC-24P-DP 71<br />

DRANETZ-BMI<br />

DRA-BMI,CAF-ETHERNET 33<br />

DRA-BMI,PG4400 30<br />

DRA-BMI,PR1500 33<br />

DRA-BMI,PR6035A/36 34<br />

DRA-BMI,PX5 30<br />

DRA-BMI,TR2021 34<br />

DRA-BMI,TR2501 34<br />

DRA-BMI,TR2510 34<br />

DRUCK<br />

DRU,DPI104-350 47<br />

DRU,DPI603-2 47<br />

DRU,DPI603-20 47<br />

DRU,DPI610-2 47<br />

DRU,DPI610-20 47<br />

DRU,DPI610-20IS 48<br />

DRU,DPI610-20-NATA 47<br />

DRU,DPI610-2-NATA 47<br />

DRU,DPI610-400 48<br />

DRU,DPI610-400-NATA 48<br />

DRU,DPI615-20-NATA 48<br />

DRU,DPI705 62<br />

DRU,DPI705-IS 62<br />

DRU,PTX1400-25 53<br />

DRU,PTX1400-4 53<br />

DRU,PTX1400-600 53<br />

DRU,PV411A 48<br />

DRU,UPS III-IS 48<br />

EA TECHNOLOGIES<br />

EAT,ULTRATEVPLUS 35<br />

ELCOMETER<br />

ELC,331-B 64<br />

ELC,331-SH 64<br />

ELGAR<br />

ELG,501 39<br />

EMERSON<br />

EME,375 48<br />

EME,475 48<br />

ENI<br />

ENI,604L 17<br />

ENVIRODATA<br />

ENV,WM20 73<br />

ETM<br />

ETM,9900 52<br />

EXCALIBER<br />

EXA,1000 75<br />

EXFO<br />

EXF,AXS-200_850 20<br />

EXF,PPM352_FIP400 22<br />

EXFO,ETS-1000L 20<br />

EXFO,FTB-860G 20<br />

EXFO,PPM350B 22<br />

FIBREOPTIC<br />

FIB,LAUNCH MM 50UM 24<br />

FIB,LAUNCH MM 62.5UM 24<br />

FIB,LAUNCH SM 9UM 24<br />

FIB,MTFS15-1000 45<br />

VARIOUS MANUFACTURERS<br />

FIT,HP 48<br />

FIT,LP 48<br />

FITEL<br />

FIT,S123M12 23<br />

FIT,S178_S325 23<br />

FIT,S325A 23<br />

FIT,SPLICER-CLEAVER 23<br />

FIXTURELASER<br />

FIX,DIRIGO 46<br />

FIX,PAT 46<br />

FLEXIM<br />

FLE,G608 54<br />

FLIR SYSTEMS<br />

FLI,E60 43<br />

FLI,T400 44<br />

FLUKE<br />

FLU,1587 35<br />

FLU,1623-KIT 27<br />

FLU,1625-KIT 27<br />

FLU,1630-EARTH CLAMP 29<br />

FLU,1653 35<br />

FLU,1735 32<br />

FLU,177 8<br />

FLU,199C-SCOPEMETER 8<br />

FLU,2042 26<br />

FLU,289 FLUKEVIEW 8<br />

FLU,376 34<br />

FLU,481 71<br />

FLU,52-2 42<br />

FLU,54-2B-FVF 42<br />

FLU,5500A 10<br />

FLU,5500A-NATA 10<br />

FLU,576 43<br />

FLU,700P08-70BAR 48<br />

FLU,700P31-690BAR 48<br />

FLU,700PD6-7BAR 48<br />

FLU,718-300G 48<br />

FLU,719-100G 49<br />

FLU,719-30G 48<br />

FLU,725 49<br />

FLU,725-NATA 49<br />

FLU,726 49<br />

FLU,743B 49<br />

FLU,744 49<br />

FLU,773 49<br />

FLU,789 PROCESSMETER 49<br />

FLU,80K-40 9<br />

FLU,80TK 42<br />

FLU,810 60<br />

FLU,87-5 8<br />

FLU,990DSL 2/2+ 22<br />

FLU,DTX1800 20<br />

FLU,DTX-MFM2 20<br />

FLU,DTX-OTDR 20<br />

FLU,DTX-PLA 20<br />

FLU,DTX-SFM2 20<br />

FLU,DTX-TERA KIT 20<br />

5


Manufacturers Index cont’d.<br />

FLU,EI-162BN 29<br />

FLU,ETHERSCOPE-EX 20<br />

FLU,FTK1000 22<br />

FLU,FTK150 22<br />

FLU,I1010AC/DC CLAMP 34<br />

FLU,I410 AC/DC CLAMP 34<br />

FLU,OPTIFIBER-PRO Q 24<br />

FLU,OPTIFIBER-SM 24<br />

FLU,OPTIVIEW-GIG 20<br />

FLU,PV350 53<br />

FLU,Ti25 44<br />

FLU,Ti32 44<br />

FLU,Ti32_WIDE-ANGLE 44<br />

FLU,TiR32 44<br />

FLU,VR1710 32<br />

FOUIER SYSTEMS<br />

FOU,DAQPRO-2 52<br />

FOU,MICROLOG-KIT 52<br />

FUJIKURA<br />

FUJ,FSM60S-CT30 23<br />

FUTEK<br />

FUT,IHH500-20T 60<br />

FUT,IHH500-2T 60<br />

GARRETT<br />

GAR,CS5000 75<br />

GEOTECH<br />

GEO,GEM5000 67<br />

GLOBAL WATER<br />

GLO,FP101 74<br />

GENRAD<br />

GR,1433-20 10<br />

GR,1433B-NATA 10<br />

GR,1433F-NATA 10<br />

GRANT<br />

GRA,GR150-S5-NATA 50<br />

GUTERMANN<br />

GUT,AQUASCOPE3 65<br />

HALOTEK<br />

HAL,78000 67<br />

HART<br />

HAR,1521-NATA 43<br />

HAR,1523-NATA 43<br />

HAR,9141-NATA 50<br />

HAR,9170-R-NATA 50<br />

HEINE TECHNO<br />

HEI,TECHNO-6X320 45<br />

HILTI<br />

HIL,PS1000 64<br />

HIL,PS20 64<br />

HIL,PS200 FERROSCAN 64<br />

HIL,TESTER4 59<br />

HIOKI<br />

HIO,3169-21 CT500AMP 32<br />

HIO,3169-21CLAMPONPT 32<br />

HIO,3169-21CT1000AMP 32<br />

HIO,3196-PQA 32<br />

HIO,3196PQA-CT1000A 33<br />

HIO,3197PQA 33<br />

HIO,3283 CLAMP ON-LT 26<br />

HIO,3284 34<br />

HIO,3285 34<br />

HIO,3290 34<br />

HIO,3332 POWERTESTER 33<br />

HIO,3404 46<br />

HIO,3423 73<br />

HIO,3455HVIT-5KV 35<br />

HIO,3551BATTERYTEST 40<br />

HIO,3641-20 52<br />

HIO,3641-20-KIT 53<br />

HIO,8421-01 53<br />

HIO,8421-51 53<br />

HIO,8422-51 53<br />

HIO,8826-32CRECORDER 50<br />

HIO,8835 50<br />

HIO,8835-01 51<br />

HIO,8835-HD520 51<br />

HIO,8841 51<br />

HIO,8842 51<br />

HIO,8860 51<br />

HIO,8870-20 51<br />

HIO,8938 51<br />

HIO,9305 51<br />

HIO,9306 51<br />

HIO,9320 51<br />

HIO,9321 51<br />

HIO,9322-KIT 53<br />

HIO,9335 52<br />

HIO,9660CT100A 34<br />

HIO,9661 CCT-500A 34<br />

HIO,9661-01 CCT-500A 34<br />

HIO,9667-FCT-5000A 35<br />

HIO,9669-CCT-1000A 35<br />

HIO,9670 Printer 35<br />

HIO,9694CT5A 35<br />

HIO,9725 52<br />

HIO,LCR 3532-50 9<br />

HIPOTRONICS<br />

HIP,880PL 36<br />

HIGH VOLTAGE INC<br />

HIV,PFT503 36<br />

HIV,VLF6022 36<br />

HIV,VLF90 36<br />

HOLADAY<br />

HOL,HI-3604 11<br />

HOL,HI-3627 11<br />

HORIBA<br />

HOR,U-52-10M 71<br />

HEWLETT-PACKARD<br />

(Also see Agilent)<br />

HP,1662A 10<br />

HP,33120A 9<br />

HP,33220A 9<br />

HP,33250A 9<br />

HP,34401A 8<br />

HP,35670A 10<br />

HP,53181A 12<br />

HP,5350B 12<br />

HP,5352B 12<br />

HP,6675A 9<br />

HP,7475A-I 9<br />

HP,8449B 17<br />

HP,8494/5B 17<br />

HP,8494B-8495B 17<br />

HP,8495B 17<br />

HP,8495D 17<br />

HP,8593E 14<br />

HP,8648C 12<br />

HP,8648D 12<br />

HP,8753C 16<br />

HP,8903B 16<br />

HP,8920A 16<br />

HP,E4407B 14<br />

HP,E4418B-001 16<br />

HP,E9300A 16<br />

HP,E9300B 16<br />

HP,E9300H 16<br />

HP,ESG-D4000A 12<br />

HEALTH PHYSICS INSTRUMENTS<br />

HPI,CYPHER5000 71<br />

HV DIAGNOSTICS<br />

HVD,HVA TD60 36<br />

HVD,HVA30-DC/VLF 36<br />

HVD,HVA60-DC/VLF 37<br />

HVD,HVA90_DC-VLF 37<br />

HYDROLAB<br />

HYD,MS5 72<br />

HYDRAMOTION LTD UK<br />

HYL,V700S-21 74<br />

HYDROLOGICAL SERVICES<br />

HYS,OSSB1 74<br />

ICC<br />

ICC,LD400 65<br />

IFR<br />

IFR,2945B 16<br />

IFR,3500A 16<br />

IkeGPS<br />

IKE,300PRO 66<br />

INTERNATIONAL LIGHT<br />

ILI,1400ABC 73<br />

ION SCIENCE<br />

ION,GASCHECK3000 67<br />

ION,GASCHECKG3 67<br />

ISC<br />

ISC,MDU420 67<br />

ISCO<br />

ISCO,6712 72<br />

ISK,6700-730 72<br />

IVIE<br />

IVI,IE35-2P 70<br />

JDSU<br />

JDSU,ANT20 21<br />

JDSU,ANT5-STM16 21<br />

JDSU,ANT5-STM4 21<br />

JDSU,EDT-135 21<br />

JDSU,FIBER_INSPECT 24<br />

JDSU,OLS-55 22<br />

JDSU,OLS-OLP 35 23<br />

JDSU,SMARTCLASS 22<br />

JDSU,SMARTCLASS-ETH 21<br />

JOFFRA<br />

JOF,C650 50<br />

JOF,CTC-1200A 50<br />

JOF,CTC-650A 50<br />

JOF,DPC-1000-NATA 49<br />

JACOBS RADIO<br />

JRC,NJJ-95B 64<br />

KYORITSU ELECTRIC<br />

KIK,TOS-5101 36<br />

KINGFISHER<br />

KIN,KI73410_LTS 23<br />

KIN,KI78010-7600 23<br />

KIN,KI7822B-7600A 23<br />

KIN,KI7827-7600 23<br />

KRAUTKRAMER GMBH & CO<br />

KRA,DYNAPOCKET 57<br />

LABEC<br />

LAB,OTWMD18 55<br />

LAPLACE<br />

LAP,SA1000 11<br />

LEM<br />

LEM,CURRENT PROBE10A 35<br />

LEM,LEM-FLEXII 35<br />

LEM,TOPAS1000 33<br />

LINEAR<br />

LIN,LSPC-1 60<br />

MADGE TECH INCORPORATION<br />

MAD,ULTRASHOCK-EB 60<br />

MARCONI<br />

MAR,6910 17<br />

MAR,6912 17<br />

MAR,6913 17<br />

MAR,6920 17<br />

MAR,6923 17<br />

MAR,6970 17<br />

RS COMPONENTS LTD<br />

MAR,PSCI424-585 27<br />

MCE LASERS<br />

MCE,LS140G 46<br />

MECMESIN<br />

MEC,AFG-1000N 59<br />

MEC,AFG-1000NALC 59<br />

MEC,TW60 59<br />

MEGGER<br />

MEG,DET2/2 29<br />

MEG,DET20C 29<br />

MEG,DET4TC2 29<br />

MEG,DLRO10 29<br />

MEG,DLRO-100LEAD 29<br />

MEG,DLRO10X 29<br />

MEG,DLRO200 29<br />

MEG,DLRO600 29<br />

MEG,DLRO-LEADSET 29<br />

MEG,LTW335-FLIT 27<br />

MEG,MIT1020-10KV DIT 36<br />

MEG,MPP1002-FAULT PP 26<br />

MEG,MPRT8430-BAS-3CH 38<br />

MEG,MT0330 37<br />

MEG,OTS80PB 37<br />

MEG,RCDT330 27<br />

MEG,S1-1052 10KV-DIT 36<br />

MEG,S1-552 5KVDIT 36<br />

MEG,TDR2000/2RM 26<br />

MEG,TTR320-47 37<br />

MEL<br />

MEL,M5-200 59<br />

METREL<br />

MET,IT3017INSTALTEST 27<br />

METRIX<br />

MET,MX2040 33<br />

MET,MX51EX 8<br />

KONICA-MINOLTA<br />

MIN,CL-200 73<br />

MINELAB EXCALIBER<br />

MIN,EX-1000 75<br />

MIN,X-TERRA-705 75<br />

MITUTOYO CORPORATION<br />

MIT,500-172 59<br />

MIT,SJ201-NATA 57<br />

MONARCH INSTRUMENTS<br />

MON,PALMSTROBE 46<br />

MON,PHASER 46<br />

MON,PLT200-KIT 46<br />

MORITEX<br />

MOR,PALMSCOPE 45<br />

MULTIAMP<br />

MUL,MS-2 38<br />

NARDA<br />

NAR,8217 71<br />

NAR,NBM-550 11<br />

NAR,RADMAN 71<br />

NOVATECH<br />

NOV,1637-5 55<br />

NTI AUDIO<br />

NTI,NT-DAS 70<br />

NTI,XL2+M2210 70<br />

OHAUS<br />

OHA,EXP4100 74<br />

OLDHAM<br />

OLD,MX21-SO2 67<br />

OLSON INSTRUMENTS INC<br />

OLS,FTG 64<br />

OLYMPUS<br />

OLY,38DL 57<br />

OLY,D790-SM 57<br />

OLY,EPOCH600 57<br />

OLY,IF8C5-30 45<br />

OLY,IPLEX-LX 45<br />

OLY,IPLEX-MX 45<br />

OLY,IPLEX-MXII 45<br />

OLY,ISPEEDLT 45<br />

OLY,IV6C6-20-ZOOM 45<br />

OMICRON<br />

OMI,CMA156-6PCA 38<br />

OMI,CMC256-6 38<br />

OMI,CMC256PLUS 39<br />

OMI,CMC356 39<br />

OMI,CMC356_61850 39<br />

OMI,CMGPS 39<br />

OMI,CPC100PTS 37<br />

OMI,CPCU1 37<br />

6


Manufacturers Index cont’d.<br />

OMI,C-PROBE1 39<br />

OMI,CPSB1 37<br />

OMI,CP-TD1 37<br />

OMI,CTANALYZER 38<br />

OMI,FRA 38<br />

OTT<br />

OTT,KL010-150 72<br />

OLYMPUS<br />

PAN,26MG 57<br />

PANAMETRICS<br />

PAN,C-LP-40NM 54<br />

PAN,C-PT-10HB 54<br />

PAN,GC-RL302 54<br />

PAN,GC-RL319 54<br />

PAN,OKS 55<br />

PAN,PM880 69<br />

PAN,PT878 54<br />

PAN,PT878E 54<br />

PAN,PT878GC-01 54<br />

PAN,PT878T 54<br />

PCB<br />

PCB,300A20 60<br />

PCTEL<br />

PCT,EX-QUAD 16<br />

PCW<br />

PCW,DC30 57<br />

PCW,P40-PULSE 57<br />

ASTRO PRODUCTS<br />

PHA,53550 61<br />

PHYNIX TECHNOLOGIES<br />

PHE,BK130 37<br />

PHOTOVAC<br />

PHO,2020PRO 67<br />

PHYNIX GMBH & CO<br />

PHY,SURFIX FN 59<br />

POLYSONICS<br />

POL,HYDRA-SX30-2 55<br />

PPM TECHNOLOGIES<br />

PPM,FORM400 67<br />

PROCEQ<br />

PRO,2000-ND 64<br />

PRO,EQUOTIP 57<br />

PROGRAMMA PRODUCTS<br />

PRO,EGIL-CB ANALYZER 39<br />

PRO,MAGNUS-2.2KV 38<br />

GE PROTIMETER PLC<br />

PRO,MMS-PLUS 64<br />

PROMAX<br />

PRO,PRODIG-5 10<br />

PRO,PROLINK4C-PREM 10<br />

PROCEQ<br />

PRO,PROFOSCOPE 64<br />

PRO,RESIPOD 64<br />

PRO,SIL-UN 64<br />

PROTIMETER<br />

PRO,SM 66<br />

PROGRAMMA ELECTRIC AB<br />

(Sweden)<br />

PRO,SVERKER760 39<br />

MEGGER<br />

PRO,TORKEL-840 40<br />

PROFOUND<br />

PRO,VIBRA 61<br />

PRUFTECHNIK<br />

PRU,AL12.116 46<br />

PRU,ROT-PROEX 46<br />

PRU,ROT-ULTRA 46<br />

QUEST<br />

QUE,2400 70<br />

RADIODETECTION<br />

RAD,AFRAME FORRD4000 65<br />

RAD,FLEXISONDE 65<br />

RAD,RD4000TYPE7KIT 65<br />

RAE SYSTEMS<br />

RAE,MR2000 68<br />

RAE,MR3000 68<br />

RISER BOND<br />

RB,1205T-OSP 26<br />

RH SYSTEMS<br />

RFS,VJ-ADV 45<br />

RH,973-SF6 68<br />

RION<br />

RIO,NL-04 71<br />

RIO,NL-05 71<br />

RIO,NL-32RTA 71<br />

RIO,NL-32RTA-NATA 71<br />

RIO,VA-10 61<br />

RIO,VA-11 61<br />

ROTOTHERM<br />

ROT,C105 50<br />

ROHDE & SCHWARZ<br />

RS,FSH3-TG 14<br />

RS,FSH3-TG-V 14<br />

RS,FSH6-TG 14<br />

RS,NRT 17<br />

SEVERN SCIENCES<br />

SEV,TORTUSII 71<br />

SEWARD<br />

SEW,PAC3760 27<br />

SEW,PT-300 27<br />

SEW,XE3760PKIT+ 27<br />

SCHAFFNER<br />

SFN,438 11<br />

SFN,MODULA 6100 11<br />

SHORTRIDGE<br />

SHO,ADM-860 62<br />

SHO,CFM88-3 62<br />

SI PRESSURE INSTRUMENTS<br />

SI,PC6-20-NATA 49<br />

SI,PC6-35-NATA 49<br />

SI,PC6-700 49<br />

SI,PC6-700-NATA 49<br />

SMC<br />

SMC,PTE-100-C 38<br />

SOCOMEC<br />

SOC,ENT-TW10 40<br />

SOFTING<br />

SOF,PROFIBUS-4 48<br />

SOLINIST<br />

SOL,122 72<br />

SOLMETRIC<br />

SOL,SUNEYE210 66<br />

SONICLEAN<br />

SON,2000HT 55<br />

SORESEN<br />

SOR,DCS150-20E 9<br />

SOR,DCS60-50 10<br />

HUBER & SUHNER<br />

SUH,SUCOFLEX-104PE 19<br />

SUNRISE<br />

SUN,SUNLITE E1 22<br />

SVANTEK<br />

SVA,912A 61<br />

SVA,SV100 61<br />

T&R TEST EQUIPMENT PTY LTD<br />

T&R,200A3PHEDIT 38<br />

T&R,CIT 38<br />

T&R,DVS3-HP 39<br />

T&R,PCU1-SP NLU5000A 38<br />

TOUR & ANDERSON<br />

TA,CBI 63<br />

TA,SCOPE 63<br />

TEKTRONIX<br />

TEK,P6015 9<br />

TEK,TDS2024B 8<br />

TEK,TDS3054 8<br />

TEK,TDS3054B 8<br />

TEK,THS730A 9<br />

TEK,TPS2014 9<br />

TESTO<br />

TES,175-H1 53<br />

TES,177-H1 53<br />

TES,177-T4 53<br />

TES,300M 55<br />

TES,319 66<br />

TES,335 55<br />

TES,350XL 55<br />

TES,445 62<br />

TES,635-2 69<br />

TES,645-1 69<br />

TES,845 43<br />

TES,880-3 V4 44<br />

TEXCEL<br />

TEX,ATM 61<br />

TOPCON<br />

TOP,BM-9-2 73<br />

TOP,IM-2D-NATA 73<br />

TOP,IM-5-NATA 73<br />

TORTECH<br />

TOR,110-2000 40<br />

TPS<br />

TPS,90FL-T 72<br />

TPS,LOW K PROBE 72<br />

TPS,REDOX 72<br />

TPS,WP-80 72<br />

TPS,WP-80M 72<br />

TPS,WP82 72<br />

TPS,WP-84 73<br />

TPS,WP-88 73<br />

TR<br />

TR,12V-BAT-CIG 10<br />

TR,RF-CABLES 19<br />

TR,RF-CONN 19<br />

TR,VIBLOG 61<br />

TRIO KENWOOD<br />

TRI,PD35-20 10<br />

TSI<br />

TSI,7565 69<br />

TSI,8324 62<br />

TSI,8345 62<br />

TSI,8373 63<br />

TSI,8375 63<br />

TSI,8386A 63<br />

TSI,8520 68<br />

TSI,8520-1 68<br />

TSI,8525 68<br />

TSI,8530 68<br />

TSI,8530-ENC 69<br />

TSI,8530-ENC-S 69<br />

TSI,8533 69<br />

TSI,8554 69<br />

TSI,8705 63<br />

TSI,8710 63<br />

TSI,9535 63<br />

TSI,9555 63<br />

TSI,9565A 63<br />

TSI,AM510 69<br />

UE SYSTEMS INC<br />

ULT,UP100KT 65<br />

UNIDATA<br />

UNI,6526B-21LCD 74<br />

UNIMEASURE<br />

UNI,P75-3C 35<br />

UNIVERSAL TECHNIC<br />

UNI,P75-3C HYBRID-DP 35<br />

UPSONIC POWER PTY LTD<br />

UPC,3000 40<br />

USB<br />

USB,232CONVERTER 9<br />

USRADAR<br />

USR,SEEK-SPR 65<br />

VAISALA<br />

VAI,WAA151 63<br />

VAI,WXT520-KIT 74<br />

VAN ESSEN<br />

VAN,DI502 73<br />

VARIAC<br />

VAR,6500-3 40<br />

AUSTRALIAN RECTIFIERS<br />

VAR,D-283-OB 40<br />

VEEX<br />

VEE,TX130 22<br />

VEEX,TX-130M+ 22<br />

VERMSON<br />

VER,222ES 8<br />

VIVAX<br />

VIV,VCAM-120M 66<br />

VIV,VCAM-60M 66<br />

VIV,VLOCPRO 65<br />

WEINSCHELL<br />

WEI,33-10-34 19<br />

WEI,34-30-34 19<br />

WEI,46-20-43 19<br />

WEI,82-30-34 19<br />

WEISS<br />

WEI,WKL-100-40 55<br />

WIKA<br />

WIK,GA-15 68<br />

WOHLER<br />

WOH,VIS2000PRO 66<br />

WOH,VIS250-S CAMERA 66<br />

WOH,VIS340-PT 66<br />

WYLER<br />

WYL,CL45 59<br />

WYLAM<br />

WYL,PORTAPAINT 59<br />

XANTREX<br />

XAN,XFR600-4 10<br />

X-RITE<br />

XRI,SP60 74<br />

YOKOGAWA<br />

YEW,3057-22 50<br />

YEW,3712-31 50<br />

YEW,3712-41 50<br />

YEW,3750 50<br />

YEW,51001-NATA 73<br />

YEW,DR130 50<br />

7


Electronics<br />

www.techrentals.com.au<br />

Multimeters & Electrometers<br />

Digital Storage Oscilloscopes<br />

Probes & Accessories<br />

Function Generators<br />

LCR Meters<br />

DC Power Supplies & Loads<br />

Spectrum Analysers - Low Frequency<br />

TV Test Equipment<br />

Laboratory Calibrators<br />

Logic Analysers/PROM Programmers<br />

Gauss/Tesla Meters<br />

E & H Field Strength Meters<br />

EMC & Power Disturbance Simulators<br />

Multimeters & ElectrometersTe<br />

See also Electrical Testers on page 26-27<br />

Fluke 87-5 Industrial True-RMS Multimeter with Thermometer<br />

FLU,87-5<br />

MY<br />

Unique function for accurate voltage and frequency measurements on<br />

adjusatable speed motor drives and other electrically noisy equipment.<br />

True-RMS AC voltage and current for accurate measurements on non<br />

linear signals. Built in thermometer. Measure up to 1,000VAC and DC.<br />

Measure up to 10A (20A for 30 seconds). 10,000uF capacitance range.<br />

Frequency to 200kHz and % duty cycle. Peak capture to record transients<br />

as fast as 250μs. 4½ digit mode.<br />

Fluke Multimeter with Backlight<br />

FLU,177 (1209)<br />

AU<br />

General purpose multimeter 0.09% basic accuracy.<br />

True RMS voltage & current measurements,<br />

digital display with analog bargraph & backlight,<br />

manual & automatic ranging, display Hold & Auto<br />

Hold, frequency & capacitance measurements.<br />

Overvoltage category EN61010-1 CAT III 1000V/CAT<br />

IV 600V.<br />

Fluke 289 True-RMS Logging Multimeter with<br />

FlukeView Software<br />

FLU,289 FLUKEVIEW (1209)<br />

AU<br />

Complete with a built-in data logger to record<br />

measurements unattended. Internal memory allows<br />

stand-alone logging for up to 180 hours. True-RMS<br />

50,000-count ¼ VGA dot matrix display. 0.025% Basic<br />

DC accuracy. CAT III 1000 V/CAT IV 600 V safety rated.<br />

Supplied with FlukeView software and download cable.<br />

See also Data Loggers on page 52-53<br />

Agilent/HP 34401A Digital Multimeter<br />

HP,34401A (1200)<br />

AU<br />

Precision 6½ digit multimeter. 100nV sensitivity on DC 120mV range. Max<br />

DC input 1kV. Measures AC voltage, DC & AC current to 3A, 2 or 4 wire<br />

resistance to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths<br />

functions including limits test. 512 point storage. RS232 & HPIB interfaces.<br />

Multimeters & Electrometers cont’d.<br />

Metrix MX51EX Intrinsically Safe Digital Multimeter<br />

MET,MX51EX (1204)<br />

AU<br />

Resolution 5,000 count with 0.1% basic accuracy. Measures AC/DC<br />

voltage & current, & resistance. Voltage sensitivity 100μV. Max voltage<br />

1kVDC, 750VAC. Max current 10A. Intrinsic safety limits of 60V & 500mA.<br />

Vermason 222541 Electrostatic Meter<br />

VER,222ES (1246)<br />

AU<br />

Electrostatic meter for periodic audits of facilities,<br />

monitoring packaging, materials, machines and other<br />

electrostatic generative equipment or processes. This<br />

precision field meter is designed to measure electrostatic<br />

voltage potentials over selected distances from 1 to 20cm.<br />

Range at the standard distance of 2cm is 20kV. Two range<br />

3 digit display in V or kV.<br />

Digital Storage Oscilloscopes<br />

Agilent MSOX3024A 200MHz Scope 4+16Ch with<br />

Logic Analyser<br />

AGI,MSOX3024A (1340)<br />

AU<br />

Mixed signal oscilloscope. 4 analogue and 16 digital<br />

channels 200MHz bandwidth, 4Gsa/s, 2Mpts<br />

memory, 1M/s waveform update rate. Search and navigate capability. Integrated<br />

time-aligned digital and analog signal viewing. USB storage, LAN operability.<br />

Agilent MSO6104A 1GHz Digital Oscilloscope<br />

with Logic<br />

AGI,MSO6104A (1320)<br />

AU<br />

1GHz 4 + 16 channel mixed signal oscilloscope<br />

(MSO). 4Gsa/s. XGA Colour display updates<br />

100,000 waveforms/s with 256 levels intensity.<br />

4 analogue channels & 16 logic channels. Deep memory. 8 digit frequency<br />

counter function. Triggering includes video, HDTV, I2C, SPI, LIN, CAN, &<br />

USB. FFT analysis included. LAN, USB, GPIB, & XGA interfaces standard.<br />

Fluke 199C Scopemeter 200MHz Hand-held<br />

FLU,199C-SCOPEMETER (1360)<br />

AU<br />

200MHz bandwidth 2 channel colour digital oscilloscope<br />

with DMM feature. 14.4cm colour display with<br />

persistence feature. 2.5GS/s real time sampling. Input<br />

sensitivity 5mV/div to 100V/div. Glitch capture 3ns using<br />

pulse width triggering. Timebase range in scope mode<br />

5ns/div to 2min/div. Trigger types auto, free run, single<br />

shot, edge, delay, video, video line, selectable pulse<br />

width and external. Automatic capture and replay of last<br />

100 screens. Measures electrical power properties such<br />

as VA VAR, etc. Isolated inputs.<br />

Tektronix TDS2024B 200MHz Digital<br />

Oscilloscope<br />

TEK,TDS2024B (1365)<br />

AU<br />

4 channel 200MHz bandwidth colour digital<br />

storage oscilloscope. 2GS/s sampling rate.<br />

Sensitivity 2mV to 5V/div. Automatic waveform<br />

measurements. Includes FFT analysis as<br />

standard. Removable data storage via front<br />

panel USB port.<br />

Tektronix TDS3054B 500MHz 4 Channel DSO<br />

TEK,TDS3054B (1330)<br />

AU<br />

TEK,TDS3054<br />

MY<br />

Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV to 10v/div. Time<br />

base 1ns to 10s/div. Trigger functions include video. Extensive automatic<br />

waveform measurements. Including FFT, TV trigger, advanced analysis<br />

(TDS3AAM), and limit testing (TDS3LIM). Battery operation.<br />

8


www.techrentals.com.au<br />

Electronics<br />

Digital Storage Oscilloscopes cont’d.<br />

Tektronix THS730A 200MHz Battery DSO<br />

TEK,THS730A<br />

MY<br />

Dual channel battery portable 200MHz digital storage<br />

oscilloscope with digital multimeter facilities. Maximum<br />

sampling rate 1GS/s. Maximum input 640V rms, maximum<br />

float 600V rms. Waveform processing including watts<br />

calculations. Video trigger. RS232 interface.<br />

Tektronix TPS2014 100MHz 4 Channel<br />

Powerscope<br />

TEK,TPS2014 (1321)<br />

AU<br />

Sampling rate 1GS/s. All 4 channels<br />

isolated for floating measurements.<br />

Sensitivity 2mV to 5V/div. Measurements<br />

for current and voltage distortion and their spectral content, harmonics,<br />

instantaneous power, power factor and switching loss. Automatic waveform<br />

measurements. FFT, power analysis, low & high voltage power probes<br />

(P5120). Battery operation.<br />

Probes and Accessories<br />

Chauvin Arnoux Current Probe E3N 0 to 100 Amp<br />

CHA,PROBE-I (1440)<br />

AU<br />

Current probe for oscilloscopes which uses a Hall effect cell for the<br />

measurement of DC or AC current. Measures currents from 50mA to<br />

100A peak. A thumbwheel can be used to reset zero for adaption to the<br />

measurement environment. The clamp can be used with any measurement<br />

instrument which has a BNC input and an impedance of 1MΩ,


Electronics<br />

www.techrentals.com.au<br />

DC Power Supplies & Loads cont’d.<br />

Sorensen DCS60-50 60V 50A DC Power Supply<br />

SOR,DCS60-50 (8114)<br />

AU<br />

0 to 60V, 0 to 50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph<br />

240V supply. On 1ph 50V@50A or 60V@42A. Remote programming.<br />

TR Built 12V Battery Supply with Cigarette Power Connector<br />

TR,12V-BAT-CIG (8160)<br />

AU<br />

12V 20AH battery pack with built-in charger. Has cigarette outlet and banana<br />

plug connectors.<br />

Trio Kenwood PD35-20 DC Power Supply<br />

TRI,PD35-20 (8109)<br />

AU<br />

Output 0 to 35V, 0 to 20A. Constant current, constant voltage. Multiple<br />

parallel or series operation. Remote programming of voltage or current by<br />

external voltage or resistance.<br />

Xantrex XFR 600-4<br />

Power Supply<br />

XAN,XFR600-4 (8112)<br />

AU<br />

2.8kW programmable DC power supply 0 to 600V, 0 to 4A. RS-232 and<br />

isolated analogue control options.<br />

Spectrum Analysers - Low Frequency<br />

See also Spectrum Analyser - High Frequency on page 12 & 14<br />

See also Noise & Sound Analysers on page 70-71<br />

Agilent/HP 35670A 100kHz Spectrum<br />

Analyser<br />

HP,35670A (2480)<br />

AU<br />

Quad channel 122μHz to 102.4kHz spectrum<br />

analyser. Up to 1600 line resolution. Displays<br />

frequency response, power spectrum, linear<br />

spectrum, coherence, cross spectrum, power<br />

spectral density, and time. Signal sources: Fixed & swept sine, arbitrary<br />

waveform, random noise, chirp. Built-in disk drive. HPIB plotter interface.<br />

Bandwidth is 102.4, 51.2 and 25.6KHz for single, dual and quad channel<br />

measurements respectively.<br />

TV Test Equipment<br />

See also Network Analysers/Antenna & Cable Test on page 14 & 16<br />

Promax TV Explorer Prodig-5<br />

PRO,PRODIG-5 (1727)<br />

AU<br />

For the installation, maintenance and surveillance<br />

of terrestrial, satellite and cable TV systems.<br />

Automatically provides information about the<br />

channels available in the network and their quality.<br />

Displays analogue and digital channel picture.<br />

Includes a high resolution spectrum analyser<br />

function and MPEG decoding. Foxtel approved.<br />

Promax Prolink 4C Premium Analogue/<br />

Digital TV Test Set<br />

PRO,PROLINK4C-PREM (1729)<br />

AU<br />

Measures terrestrial, satellite and cable<br />

TV systems including analogue and digital<br />

VHF & UHF bands. Built in colour monitor provides measurement readout and<br />

can be used to display video signal. Measurement functions include spectrum<br />

analysis, direct signal level readout, carrier to noise, channel power, digital<br />

carrier to noise, digital bit error ratio (BER) and digital QAM constellation.<br />

DVB digital TV channel identifier. Logs to PC and includes software for<br />

remote control and channel plan management.<br />

Laboratory Calibrators<br />

See also Industrial Process Calibrators on page 46-49<br />

Fluke 5500A Multi Product<br />

Calibrator with NATA Calibration<br />

FLU,5500A-NATA (4707)<br />

AU<br />

FLU,5500A<br />

MY<br />

Calibrator sources direct voltage<br />

& current, alternating voltage and<br />

current, with multiple waveforms and harmonics, 2 simultaneous voltage<br />

outputs or voltage & current. Simulates power with phase control, resistance,<br />

capacitance, thermocouples and RTDs. Selectable ranges include the<br />

following outputs VDC from 0 to 1.02kV, VAC from 1mV to 1.02kV with output<br />

from 10Hz to 500kHz. AC current from 0.01μA to 11A with output from 10Hz<br />

to 10kHz. DC current from 0 to 11A. Resistance values from short circuit<br />

to 330MΩ. Capacitance values from 330pF to 1,100μF. Temperature t/c B,<br />

C, E, J, K, L, N, R, S, T, U, RTD Pt385 100Ω, Pt3926 100Ω, Pt3916 100Ω,<br />

Pt385 200Ω, Pt385 500Ω, Pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.<br />

Genrad 1433B 1.1MΩ 6 Decade Resistance<br />

GR,1433B-NATA (4702)<br />

Six decades by 1Ω to 1.1MΩ. Accuracy 0.01%. NATA calibrated.<br />

Genrad 1433F 111k 7 Decade Resistance Box<br />

GR,1433F-NATA (4704)<br />

AU<br />

Seven decades by 0.01Ω to 111k. Accuracy 0.01% +0.002Ω. Useful for<br />

platinum resistance thermometer calibration. NATA calibrated.<br />

Genrad 1433-20 11.1111kΩ<br />

6 Decade Resistor<br />

GR,1433-20<br />

MY<br />

Six decades by 0.01Ω per step to<br />

11.1111kΩ. High accuracy 0.01% up to 10MΩ steps. Low temperature<br />

coefficient, 5ppm/˚C. Good frequency characteristics, excellent stability<br />

(10ppm/yr, 25ppm/3yrs), low zero resistance (1MΩ per decade). May be used<br />

for RTD stimulation. Rack mount option.<br />

Logic Analysers/PROM Programmers<br />

HP 1662A 68 Channel Logic Analyser<br />

HP,1662A (1570)<br />

MY<br />

Timing analysis 250MHz all channels, 500MHz half channels. Transitional:<br />

125MHz all channels, 250MHz half channels. Glitch: 125MHz half<br />

channels. State analysis to 100MHz on all channels. Memory 4k/channel,<br />

8k/channel in half-channel modes. 4 clock channels available. HPIB &<br />

RS232C ports. In-built DOS format FDD used to load inverse assemblers<br />

& transfer measurement data to a computer. Compatible with most HP<br />

preprocessors & inverse assemblers.<br />

Gauss/Tesla Meters<br />

FW Bell Gauss/Tesla Meter<br />

BEL,4190 (1969)<br />

AU<br />

Handheld digital ELF gauss meter. Maintains<br />

accuracy regardless of orientation. Applications<br />

include detecting magnetic field emissions from<br />

overhead AC power lines, video display terminals,<br />

office equipment and household appliances.<br />

Analogue o/p, data logging, auto range 0.1 to 1999<br />

mG, minimum resolution 0.1mG/.01 uT.<br />

AU<br />

10


www.techrentals.com.au<br />

Electronics<br />

Gauss/Tesla Meters cont’d.<br />

FW Bell 5180 Gauss/Tesla Meter<br />

BEL,5180 (1960)<br />

AU<br />

Magnetic measuring equipment, portable gaussmeter.<br />

Functions include Auto Zero, Min/Max/Peak Hold,<br />

Auto Range and Relative Mode. Displays in Gauss,<br />

Tesla or Ampere/Meter. With Hall effect transverse<br />

probe. Bandwidth DC to 30kHz, ranges 300G to<br />

30kG, resolution 0.1G. Analogue output (±3V FS) and<br />

USB interface. Battery operated.<br />

E & H Field Strength Meters cont’d.<br />

Narda NBM-550 E Field Strength Meter<br />

NAR,NBM-550 (1930)<br />

AU<br />

Broadband field strength meter. Applications include<br />

measuring field strengths to comply with general safety<br />

regulations and actual radiated power. Measuring<br />

broadcasting, radar, cell towers, and other transmission<br />

sources. Includes GPS position, data logging and voice<br />

recording for comments. EF1891 measuring electric fields<br />

from 3MHz to 18GHz.<br />

E & H Field Strength Meters<br />

See also Radiation Montioring & Protection on page 71<br />

Holaday HI-3604 LF E & H Field Monitor<br />

HOL,HI-3604 (1945)<br />

AU/MY<br />

Low frequency field meter. Designed to evaluate electric and magnetic<br />

fields associated with 50Hz power lines. Frequency range 30 to 2,000Hz.<br />

Measures magnetic fields from 0.1mG to 20G. Measures electric fields<br />

from 1V/meter to 200kV/meter. LCD display. 127 reading data memory.<br />

Meets the interim requirements of the Australian Radiation Laboratory for<br />

normal levels of AC power exposure.<br />

Holaday HI-3627 Magnetic Field Meter<br />

HOL,HI-3627 (1980)<br />

AU<br />

Three orthogonal field sensors. Dynamic<br />

range 0.2mG to 20G. True RMS detection.<br />

Frequency range 5Hz to 2kHz with an in-built<br />

30Hz high pass filter. Meets requirements of<br />

the Swedish protocol and the IEEE P-1140<br />

protocol.<br />

EMC & Power Disturbance<br />

Simulators<br />

Laplace SA1000 EMC Test System<br />

LAP,SA1000 (8370)<br />

AU<br />

Comprises PC controlled spectrum analyser 10kHz to 1.1GHz,<br />

SA1020 pre-amplifier, RF200 broadband antenna 30MHz to 1GHz,<br />

TTI LISN1600 LISN, and RF100 E-field & H-field probes. Supplied<br />

with notebook PC and EMC software. EMC compliance test system.<br />

Schaffner 438 30kV Static Discharge Generator<br />

SFN,438 (8375)<br />

AU<br />

Generates an electrostatic charge in a range from<br />

2 to 30kV. This instrument is in a ‘gun’ form. Has<br />

a removable discharge network which can be<br />

interchanged with other (optional) impedance<br />

networks. Performs test to IEC61000-4-2 (AKA, IEC<br />

1000-4-2) standards.<br />

Schaffner Modula-6100<br />

Immunity Test System<br />

SFN,MODULA 6100 (8380)<br />

AU<br />

Multifunction generator to simulate<br />

electro-magnetic field interference effects<br />

for immunity testing in conformity with<br />

international, national and in house standards including the new IEC/EN<br />

standards. Generates Interference pulses such as burst and surge and<br />

power quality simulations.<br />

TRAINING FROM TECHRENTALS<br />

• <strong>Tech</strong><strong>Rentals</strong> can offer manufacturer training on high-end Electrical, Telecommunication<br />

and NDT testing (fees vary).<br />

• Training can be done on specific assets as part of the set up and download service (fees apply).<br />

• Videos are available on the website to assist in operation of certain models.<br />

<strong>Tech</strong><strong>Rentals</strong> offers a number of short courses designed to enhance skills and experience in areas<br />

of particular benefi t to technical personnel. Notices of these courses are sent by email requesting an<br />

expression of interest and take place throughout Australia.<br />

If you have not already visited <strong>Tech</strong><strong>Rentals</strong> Wiki, it is well worth a visit.<br />

The resource centre provides manuals, technical information and how-to videos. www.techrentals.com.au<br />

select <strong>Tech</strong>nical Tips and Videos.<br />

11


Radio Frequency<br />

www.techrentals.com.au<br />

RF Signal & Sweep Generators<br />

Frequency Counters<br />

Spectrum Analysers - High Frequency<br />

Network Analysers/Antenna & Cable Test<br />

Communication Test Sets<br />

Distortion Analysers<br />

Power Meters - RF<br />

RF Amplifiers<br />

RF Attenuators<br />

Antennas<br />

RF Accessories<br />

RF Signal & Sweep Generators<br />

See also Function Generators on page 9<br />

Agilent/HP 8648C-1E5 3GHz Signal Generator<br />

HP,8648C<br />

MY<br />

Signal generator 9kHz to 3.2GHz with AM/FM/Phase modulation output range<br />

from +10 to -136dBm with ±1 accuracy up to 2.5GHz. 0.001Hz resolution.<br />

Agilent/HP 8648D-1E5 4GHz Signal<br />

Generator<br />

HP,8648D (2330)<br />

AU//MY<br />

Signal generator 9kHz to 4GHz with AM/<br />

FM/Phase modulation output range from<br />

+10 to -136dBm with ±1dB accuracy up<br />

to 2.5GHz. 0.001Hz resolution. Complete<br />

with option 1E5 high stability timebase<br />

(


Originally established in 1983 as the<br />

Computer Division of <strong>Tech</strong><strong>Rentals</strong>,<br />

TR Vidcom is Australia’s vibrant company<br />

in the exciting IT and Audio Visual industry.<br />

Specialists in supplying IT hardware, project management, audio<br />

visual turn key solutions and facilitating short and long term projects on<br />

everything IT and AV, TR Vidcom delivers unparalleled levels of service<br />

and a comprehensive range of leading-edge products at competitive rates.<br />

Our product range includes:<br />

• Desktops and Notebooks<br />

• LCD and Plasma Screens<br />

• Printers and Plotters<br />

• Multi Panel Plasma Displays<br />

• Projectors and Screens<br />

• Apple Products<br />

• Servers and Networking<br />

• Training Aids and Interactive<br />

Whiteboards<br />

• Video and Teleconferencing<br />

• Stocktake Equipment<br />

• Rich Media Streaming<br />

Our vision at TR Vidcom is to respond to clients’ needs by combining<br />

technology, equipment and technical expertise.<br />

To request a copy of TR Vidcom’s<br />

Guide to Rental Services and<br />

Solutions, call one of our experts<br />

on 1800 843 266.<br />

vidcom<br />

1800 843 266<br />

www.trvidcom.com.au<br />

rent@trvidcom.com.au<br />

VC0185


Radio Frequency<br />

www.techrentals.com.au<br />

Spectrum Analysers - High Frequency<br />

cont’d.<br />

Anritsu MS2711D 3GHz Colour<br />

Portable Spectrum Analyser<br />

ANR,MS2711D (2548) AU<br />

Light weight battery powered spectrum<br />

analyser with colour LCD. Range<br />

9kHz to 3GHz. Resolution bandwidth from<br />

100Hz to 1MHz. -135 dBm Noise Floor.<br />

Can identify the type of interfering signal. Used in applications such as<br />

cellular telephone walk or drive tests to determine coverage and base station<br />

positioning and VHF/UHF signal surveying. N type connector.<br />

Anritsu MS2711D 3GHz Spectrum Analyser GPS & Interference Analysis<br />

ANR,MS2711D -31-25 (2547)<br />

AU<br />

9kHz to 3GHz. Resolution bandwidth from 100Hz to 1MHz. Interference<br />

Analysis opt provides spectrogram display, RSSI and signal strength with<br />

audio output for radio direction finding. GPS function provides Latitude,<br />

Longitude and Altitude with trace storage. Can be used in applications such as<br />

cellular telephone walk or drive tests to determine coverage and base station<br />

positioning and also VHF/UHF signal surveying. N type connector.<br />

Anritsu MS2721A 7.1 GHz Spectrum<br />

Analyser<br />

ANR,MS2721A (2549)<br />

AU<br />

100kHz to 7.1GHz. For deploying, maintaining<br />

and troubleshooting wireless base stations<br />

and Wi-Fi (802.11a, b and g) systems,<br />

and general spectrum analysis. Smart<br />

measurements include channel power, adjacent channel power ratio, carrier to<br />

interference ratio and field strength. AM/FM/SSB demodulator included and<br />

internal speaker for monitoring. DANL -153 dBm at 1GHz. Phase noise -100dBc/<br />

Hz at 10KHz. Store unlimited traces and setups. Remote programming via<br />

Ethernet port.<br />

Agilent/HP E4407B 26.5GHz Spectrum Analyser<br />

HP,E4407B (2540)<br />

AU<br />

Frequency range 9kHz to 26.5GHz. Resolution<br />

bandwidth down to 30Hz. Noise level -105 to<br />

-136dBm according to frequency. Centre frequency<br />

display with a resolution of up to 10Hz. Stores up to<br />

200 traces in internal memory and 200 traces on disk.<br />

Agilent/HP 8593E 22GHz Spectrum Analyser<br />

HP,8593E<br />

MY<br />

Frequency range 9kHz to 22GHz. Max resolution 30Hz. Noise level -102 to<br />

-127dBm according to frequency. Centre frequency display with a resolution<br />

of up to 10Hz. Some assets include GPIB/parallel and narrow resolution<br />

bandwidth options (041 & 130).<br />

Rohde & Schwarz FSH3 3GHz Spectrum Analyser/Tracking Generator/<br />

Vector Measurement<br />

RS,FSH3-TG<br />

MY<br />

Handheld portable battery operated spectrum analyzer 100kHz to 3GHz.<br />

Resolution bandwidth 1 kHz to 1 MHz. Less than -105 dBm noise level (-116 dBm<br />

typical). Colour liquid crystal display. Suitable for RF surveying applications.<br />

Includes tracking generator, VSWR bridge and distance to fault (DTF) options<br />

making it suitable for antenna and cable testing. 4 hours of continuous operation<br />

on battery power. Comes with cable for data transfer to PC.<br />

How-to video is available at<br />

www.techrentals.com.au<br />

<strong>Tech</strong>nical Tips and Videos<br />

Spectrum Analysers - High Frequency<br />

cont’d.<br />

Rohde & Schwarz FSH3 3GHz Spectrum Analyser/<br />

Tracking Generator/Vector Measurement<br />

R S,FSH3-TG-V (2536)<br />

AU<br />

Handheld portable battery operated spectrum analyser<br />

100kHz to 3GHz. Resolution bandwidth 1kHz to 1MHz.<br />

Less than -105dBm noise level (-114dBm typical).<br />

Suitable for RF surveying applications. Includes vector<br />

transmission and tracking generator options.<br />

Rohde & Schwarz FSH6 6GHz Spectrum Analyser/Tracking Generator<br />

R S,FSH6-TG (2537)<br />

AU<br />

Handheld battery operated spectrum analyser 100kHz to 6GHz. RBW 1kHz to<br />

1MHz. Noise level to 3GHz, -112dBm; 5 to 6GHz, -102dBm typically. Suitable<br />

for RF surveying applications. Includes, VSWR bridge and DTF options<br />

making it suitable for antenna and cable testing.<br />

Network Analysers/Antenna<br />

& Cable Test<br />

Agilent FieldFox 6GHz RF Analyser N9912A<br />

AGI,N9912A (2145)<br />

AU<br />

Cable and antenna analyser. Frequency range 2MHz<br />

to 6GHz. Measures return loss, one-port cable loss,<br />

distance to fault, line sweeping, and VSWR. Applications<br />

include cable & antenna installation and maintenance<br />

for wireless service providers, contractors, military,<br />

aerospace, defence, and public safety applications.<br />

Anritsu S331D 4GHz Colour<br />

Sitemaster Antenna<br />

ANR,S331D (2120)<br />

AU/MY<br />

Antenna and cable test set. Frequency range<br />

25MHz to 4GHz. Measures return loss, SWR,<br />

cable loss, and distance to fault. Return loss<br />

range 0 to 60dB. SWR range 1 to 65. Distance<br />

to fault range 1,197m. Insertion loss range -120 to +100dB. Cable loss range<br />

(one port) 0 to 30dB. N(f) Type port. Analysis software discs included containing<br />

distance to fault and Smith chart tools. Complete with calibration standard,<br />

AC/DC adaptor, and 12VDC car cigarette lighter adaptor.<br />

Anritsu S331E 4GHz<br />

Sitemaster Cable &<br />

Antenna Tester<br />

ANR,S331E (2119)<br />

AU/MY<br />

Cable and antenna analyser, frequency range<br />

2MHz to 4GHz. Measures return loss, VSWR,<br />

cable loss, and Distance To Fault. Suitable for<br />

legacy networks in addition to the new 3G and 4G networks being installed.<br />

Applications include cable & antenna installation and maintenance for wireless<br />

service providers, contractors, military, aerospace, defence, and public safety<br />

applications.<br />

Anritsu S332D Colour Sitemaster<br />

Antenna Tester<br />

ANR,S332D<br />

MY<br />

Antenna and cable test set including spectrum<br />

analyser. Frequency range 25 to 4,000MHz.<br />

RBW 100Hz to 1MHz. Measures return loss,<br />

SWR, cable loss, and distance to fault. N(f) Type port. Analysis software<br />

containing DTF and Smith chart tools included. Complete with calibration<br />

standard, AC/DC adaptor, and 12VDC car adaptor.<br />

14


The sky is the limit for OTA testing of MIMO LTE<br />

TM<br />

BTS Master MT8222B<br />

Simplify measurement of MIMO and<br />

remote radio head LTE transmitters.<br />

Anritsu provides the most comprehensive OTA (Over-the-Air)<br />

testing for both FDD & TDD LTE base stations, including a unique<br />

transmitter test function to ease verifi cation and troubleshooting<br />

of MIMO transmitters. With automatic detection of MIMO and<br />

on-screen coverage mapping, you can validate the quality of<br />

your LTE coverage – even while operating with live traffi c.<br />

Spectrum Master<br />

E Series<br />

TM<br />

Spectrum Master<br />

C Series<br />

TM<br />

Cell Master TM<br />

BTS Master TM<br />

Sales Office: Australia 1800 689 685. www.anritsu.com/en-au<br />

15


Radio Frequency<br />

www.techrentals.com.au<br />

Network Analysers/Antenna<br />

& Cable Test cont’d.<br />

Anritsu S332E Sitemaster including<br />

Spectrum Analyser<br />

ANR,S332E (2141)<br />

AU<br />

Antenna and cable analyser 2MHz to 4GHz<br />

and spectrum analyser 100KHz to 4GHz.<br />

DANL -152dBm. Measures return loss, VSWR,<br />

cable loss, and distance to fault. N(f) Type<br />

port. Analysis software containing DTF and Smith chart tools included.<br />

Complete with calibration standard, AC/DC adaptor, and 12VDC car adaptor.<br />

Cable & antenna installation and maintenance for wireless service providers,<br />

contractors, military, aerospace and defence, and public safety applications.<br />

Anritsu S332E Sitemaster Including<br />

Spectrum Analyser and Opt 431,31,509<br />

ANR,S332E-CMPA-MOD (2142)<br />

AU<br />

antenna and cable analyser 2MHz to 4GHz and<br />

spectrum analyser 100KHz to 4GHz. DANL<br />

-152dBm. Options included, indoor outdoor<br />

Coverage Mapping, GPS Receiver and AM/FM/<br />

PM Analyser. Measures return loss, VSWR, cable loss, and distance to fault.<br />

Analysis software containing DTF and Smith chart tools included. Cable,<br />

antenna, installation and maintenance spectrum analysis, coverage mapping<br />

and AM/FM/PM demod for wireless service providers, contractors, military,<br />

aerospace and defence, and public safety applications.<br />

Anritsu S820D Microwave Sitemaster<br />

25MHz to 20GHz<br />

ANR,S820D (2150)<br />

AU/MY<br />

Microwave antenna and cable test set. Portable<br />

single port analyser, providing return loss<br />

(SWR) insertion loss and distance to fault<br />

measurements in the frequency range of 25MHz to 20GHz. Unit comes<br />

standard with RS232 interface, Smith chart and software management tools,<br />

AC/DC and automotive adaptor. A comprehensive range of precision waveguide<br />

components and adaptors are available.<br />

Anritsu Sitemaster Waveguide Components<br />

ANR,WAVEGUIDE-ADAP (2170)<br />

AU/MY<br />

Calibration components and wave guide to co-ax adaptors for Anritsu S820x<br />

Sitemaster. Set includes 1/8 and 3/8 shorts, termination, and waveguide to<br />

co-ax adaptor.<br />

Agilent/HP 8753C 3GHz Network Analyser<br />

HP,8753C<br />

MY<br />

300 kHz to 3 GHz integrated 1Hz resolution synthesized source. Direct save/<br />

recall to an external disk drive . Time domain analysis. Execute complex test<br />

procedures with the test sequence function. 100dB of dynamic range. Group<br />

delay and deviation from linear phase. 0.001dB, 0.01˚C, 0.01 nanosec marker<br />

resolution. Built-in accuracy enhancement. Swept harmonic measurements.<br />

Communication Test Sets<br />

Aeroflex IFR 2945B<br />

Communications Service<br />

Monitor<br />

IFR,2945B (2368)<br />

AU<br />

Communications Service Monitor is ideally suited<br />

to the testing of two way radios and trunking repeaters allowing verification<br />

of performance, and rapid diagnosis of faults. Includes a combination of test<br />

instruments such as a full performance spectrum analyser, oscilloscope and<br />

tracking generator. Frequency range 400kHz to 1.05GHz.<br />

Communication Test Sets cont’d.<br />

Aeroflex IFR 3500A Radio<br />

Communications Test Set<br />

IFR,3500A (2360)<br />

AU<br />

Communications service monitor. Portable radio test set<br />

for AM, FM, P25, DMR and NXDN radio transceivers,<br />

antenna and cable testing in vehicle, at remote locations<br />

or on bench testing. Frequency range 2M to 1GHz. 20W<br />

power handling without external attenuator. Includes spectrum analyser,<br />

oscilloscope, tracking generator, P25 test option and 75W attenuator.<br />

Agilent/HP 8920A Communications Test Set<br />

HP,8920A (2375)<br />

AU<br />

Frequency range of 250kHz to 1GHz.<br />

Includes an AM/FM signal generator, AM/FM<br />

modulation analyser, duplex offset generator,<br />

SSB demodulator, RF power meter, frequency<br />

counter, AC/DC voltmeter, SINAD meter, distortion meter, oscilloscope<br />

and two variable audio sources. Includes spectrum analyser with tracking<br />

generator. Antenna & microphone are included.<br />

PCTel Scanning Receiver<br />

PCT,EX-QUAD (2365)<br />

AU<br />

EX Scanner GSM 900/1800 WCDMA 2100/900.<br />

High speed Top N Scrambling Code Scanning.<br />

GSM colour code (BSIC) Scanning. Multiple<br />

concurrent measurements. RSSI and immediate RSSI reporting. Spectrum<br />

analysis measurements. Layer 3 BCH/BCCH decoding. High accuracy C/I<br />

measurements. Built-in GPS receiver.<br />

Distortion Analysers<br />

Agilent/HP 8903B Audio Analyser<br />

HP,8903B (3020)<br />

AU<br />

Audio analyser for communications and other applications. Measures<br />

distortion, sinad, signal-to-noise, ACV, DCV, frequency. Low distortion<br />

programmable sine wave source. Frequency range 20Hz to 100kHz. Optional<br />

400Hz high pass and CCITT weighting filters fitted.<br />

Power Meters - RF<br />

Agilent/HP E4418B E Series Power Meter<br />

HP,E4418B-001 (2103)<br />

AU<br />

100μW to 25W (-70dBm to 44dBm), 9 kHz to<br />

110 GHz (power sensor dependent ), 4 digit<br />

display - watts, dBm, dB (rel). Battery or mains<br />

powered. Power sensor required, select and<br />

specify when ordering.<br />

Agilent/HP E9300A Power Sensor 1μW to 100mW, 10MHz to 18GHz<br />

HP,E9300A (2108)<br />

AU<br />

Power sensor for HP EPM series power meters. E-series average power<br />

sensor. 10MHz to 8GHz, 1μW to 100mW (-60dBm to 20dBm).<br />

Agilent/HP E9300B Power Sensor 1μW to<br />

25W, 10MHz to 8GHz<br />

HP,E9300B (2109)<br />

AU<br />

Power sensor for HP EPM series power meters.<br />

E-series average power sensor. 10MHz to<br />

18GHz, 1μW to 25W (-30dBm to 44dBm).<br />

Agilent/HP E9300H Power Sensor 10nW to 1W, 10MHz to 18GHz<br />

H P,E9300H (2110)<br />

AU<br />

Power sensor for HP EPM series power meters. E-series Average Power<br />

Sensor. 10MHz to 18GHz, 10nW to 1W (-50dBm to 30dBm).<br />

16


www.techrentals.com.au<br />

Radio Frequency<br />

Power Meters - RF cont’d.<br />

Anritsu MA24104A Inline Power<br />

Sensor 0.6 to 4GHz, 2mW to 150W<br />

ANR,MA24104A (2105)<br />

AU<br />

A dual path architecture that enables true RMS<br />

measurements over the entire frequency and dynamic<br />

range allowing users to measure CW, multi-tone and<br />

digitally modulated signals such as GSM/EDGE, CDMA/<br />

EV-DO,WCDMA/HSDPA, WiMAX, and TD-SCDMA.<br />

Can be connected directly to a laptop or Site Master with<br />

option 19.<br />

Bird 43 Power Meter<br />

BIR,43<br />

MY<br />

RF thruline power meter. Requires Bird element of specified frequency and<br />

power. Measures forward and reflected power by reversing the element.<br />

Bird RF Element<br />

BIR,ELEMENT-LF<br />

MY<br />

BIR,ELEMENT-HF<br />

MY<br />

RF elements for Bird watt meters. Available in various power and frequency<br />

ranges.<br />

Marconi 6970 Digital Power Meter<br />

MAR,6970<br />

MY<br />

NiCd battery operated with digital display. Complete with AC adaptor. Requires<br />

sensor. Sensors available for 10MHz to 26.5GHz frequency range.<br />

Marconi 6910 Power Sensor<br />

MAR,6910<br />

MY<br />

Frequency range 10MHz to 20GHz. Power range -30dBm to 20dBm (1μW to<br />

100mW). Max RF i/p 25dBm (300mW) CW 42dBm (15W) peak for 2μs. Sensing<br />

element semiconductor thermocouple. VSWR 1.25: 10MHz to 30MHz, 1.1:<br />

30MHz to 2GHz, 1.18: 2 to 16GHz, 1.28: 16 to 18GHz, 1.4: typical 18 to 20GHz.<br />

Linearity factor provided with sensor. Accuracy ±0.5% at 25˚C between 10<br />

& 20dBm. Improves by a factor of 10 for each lower range. Calibration factor<br />

provided with sensor. Accuracy uncertainty provided with sensor. Resolution<br />

0.01%. RF connector precision N-type (M) 50Ω.<br />

Marconi 6912 Power Sensor<br />

MAR,6912<br />

MY<br />

Frequency range 30kHz to 4.2GHz. Power range 30dBm (1μW) to 20dBm<br />

(100mW).<br />

Marconi 6913 Power Sensor<br />

MAR,6913<br />

MY<br />

Frequency range 10MHz to 26.5GHz. Power range 30dBm (1μW) to 20dBm<br />

(100mW). Max 25dBm (300mW) CW, 42dBm (15W) peak for 2μs. Sensing<br />

element semiconductor thermocouple. VSWR 1.40: 10MHz to 50MHz, 1.15:<br />

50MHz to 100MHz, 1.10: 100MHz to 2GHz, 1.15: 2 to 12.4GHz, 1.20: 12.4 to<br />

18GHz, 1.25: 18 to 26.5GHz. Calibration factor provided at 1GHz intervals<br />

(500MHz intervals above 20GHz) with each sensor. Accuracy uncertainty<br />

provided with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5%<br />

at 100mW, decreasing by 0.005% per 1mW.<br />

Marconi 6920 Power Sensor<br />

MAR,6920<br />

MY<br />

High sensitivity diode sensor. Frequency range 10MHz to 20GHz. Power<br />

range -70dBm (0.1nW) to -20dBm (10μW), max 26dBm (400mW) CW<br />

+30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR<br />

1.4 to 1.2:10 to 40MHz, 1.20:40MHz to 10GHz, 1.35:10 to 18GHz, 1.40<br />

typical 18 to 20GHz. Calibration factor provided at 1GHz intervals with each<br />

sensor. Accuracy uncertainty provided with each sensor.<br />

Power Meters - RF cont’d.<br />

Marconi 6923 RF Power Sensor<br />

MAR,6923<br />

MY<br />

High sensitivity diode sensor. Frequency range 10MHz to 26.5GHz. Power<br />

range -65dBm (0.3nW) to -20dBm(10μW), max 26dBm (400mW) CW,<br />

+30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR<br />

1.4 10 to 40MHz, 1.15 40 to 100MHz, 1.12 0.1MHz, 1.17 2 to 8GHz, 1.30 8<br />

to 18GHz, 1.50 typical 18 to 26.5GHz. Calibration factor provided at 1GHz<br />

intervals with each sensor. Accuracy uncertainty provided with each sensor.<br />

Resolution 0.01%. Linearity factor provided with each sensor. Accuracy<br />

±1% between -30 to -20dBm. RF connector type N (M) precision 50Ω.<br />

Rohde & Schwarz NRT Power Reflection Meter<br />

RS,NRT<br />

AU<br />

Measures directional power forward and reverse under operational<br />

conditions. NRT-Z44 sensor included, range 3 mW to 120 W, 200 MHz to<br />

4 GHz. Measurement method is compatible with all common analog and in<br />

particular digital modulation standards. GSM/EDGE, 3GPP (W-/TD-CDMA),<br />

CDMA (IS-95), CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB, DVB-T<br />

and many more.<br />

RF Amplifiers<br />

ENI 604L 4W Wideband 1GHz RF Amplifier<br />

ENI,604L (2803)<br />

AU<br />

Linear wideband RF power amplifier. 4W output at an input of 0.13mW from<br />

0.5 to 1GHz. Saturated output 7W 0dBm input. Extended performance<br />

gives saturated output to a max of 16W at 10MHz and 12W at 100MHz<br />

typically.<br />

Agilent/HP HP8449B Preamplifier 1GHz to 26.5GHz<br />

HP,8449B (2805)<br />

MY<br />

High-gain (+30dB gain), low-noise preamplifier. Frequency range of 1 to<br />

26.5GHz. Increases sensitivity of any microwave spectrum analyser for<br />

detection and analysis of very low-level signals. Improved sensitivity can<br />

reduce measurement time.<br />

RF Attenuators<br />

Agilent/HP 8494B/8495B Attenuator Set 81dB, 1 & 10dB steps 18GHz<br />

HP,8494B-8495B (2904)<br />

AU/MY<br />

Coaxial step attenuator set. DC to 18GHz. 0-11dB in 1dB steps and 10-70dB in<br />

10dB steps. Type N(f) connectors. Comprises a connected set of types 8494B<br />

and 8495B with 11716A rigid interconnect kit.<br />

Agilent/HP 8495B 70dB x 10dB Coaxial Step Attenuator<br />

HP,8495B (2902)<br />

DC to 18GHz. 0 to 70dB in 10dB steps.<br />

Agilent/HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB<br />

HP,8494/5B<br />

MY<br />

DC to 18GHz. 0 to 11dB in 1dB steps. 11 to 81dB in 10dB steps. Comprises a<br />

connected set of types 8494B & 8495B. Type N(f) connectors.<br />

Agilent/HP 8495D 70dB 26.5GHz Step Attenuator<br />

HP,8495D (2905)<br />

MY<br />

Frequency range DC to 26.5GHz. 70dB step attenuator in 10dB steps. Max<br />

continuous power 1W. 3.5mm connectors.<br />

Anritsu Attenuator 50W 30dB DC to 18GHz<br />

ANR,50-30-18 (2903)<br />

30dB, 18GHz, 50W. N Type connectors.<br />

AU<br />

AU<br />

17


PROJECT RENTALS<br />

www.techrentals.com.au<br />

Is your major project?<br />

Telecommunication • Construction • Road or Rail infrastructure<br />

National Broadband Network • Power Generation<br />

With over 35 years experience <strong>Tech</strong><strong>Rentals</strong> technical sales staff will assist you in delivering the right test and<br />

measurement solution for your major project. Whatever the duration, the best solution will be tailored to your<br />

requirements, making this part of your project simple and easy.<br />

With access not only to our vast inventory but to our global partners’ inventory you can be assured we will deliver<br />

the best solution for you.<br />

18


www.techrentals.com.au<br />

Radio Frequency<br />

RF Attenuators cont’d.<br />

Weinschell 33-10-34 25W 10dB 8.5GHz RF Attenuator<br />

WEI,33-10-34 (2919)<br />

DC to 8GHz, 10dB, 25W. Type N connectors.<br />

Weinschell 34-30-34 25W 30dB 4GHz RF Attenuator<br />

WEI,34-30-34 (2922)<br />

DC to 4GHz, 30dB, 25W. Type N connectors.<br />

Weinschell 46-20-43 25W 20dB 18GHz RF Attenuator<br />

WEI,46-20-43 (2921)<br />

DC to 18GHz, 20dB, 25W. Type N connectors.<br />

Antennas<br />

Weinschel 82-30-34, 30dB 1000W 3GHz<br />

Coaxial Attenuator<br />

WEI,82-30-34 (2924)<br />

DC to 3GHz, 30dB, 1,000W.<br />

AU<br />

AU<br />

AU<br />

AU<br />

Antennas cont’d.<br />

AH Systems SAS-200/571 Antenna<br />

AH,SAS-200/571 (1840)<br />

AU<br />

AH,SAS-571<br />

MY<br />

Double ridge guide horn antenna. Frequency range 700MHz to 18GHz.<br />

Continuous power 300W. Impedance 50Ω 200V/m max radiated field. Type<br />

N(f) connector.<br />

Anritsu Dipole Antenna Kit<br />

ANR,ANTENNA (1834)<br />

MP534A dipole antenna 25 to 520MHz and MP651A 470 to 1700MHz.<br />

Directional Yagi Antenna<br />

ANT,DIRECTIONAL YAGI (1829)<br />

AU<br />

Various directional Yagi antennas. Frequency rangers from 824 M (UHF) to<br />

2.17 GHz (UHF).<br />

Omnidirectional Antenna<br />

ANT,OMNIDIRECTIONAL (1826)<br />

AU<br />

Various omnidirectional antenna types such as telescopic whip, folded dipole<br />

and monopole. Frequency ranges from 70MHz to 2.17GHz.<br />

AU<br />

Advantest TR1720 100kHz to 30MHz Antenna<br />

ADV,TR1720 (1847)<br />

AU<br />

Loop and vertical antenna system. Frequency range 100kHz to 30MHz.<br />

Suitable for use with ADV,R4131D for field strength and EMI measurements.<br />

An antenna tuner is included which can be used as an input/output filter to<br />

reject noise below the measuring frequency.<br />

AH Systems 300MHz to 12GHz Antenna System<br />

AH,ANTENNA (1834)<br />

AU<br />

Log periodic antenna system. Comprises two antennas: A: 300MHz to<br />

1.8GHz, power handling 1kW, antenna factor 15 - 32dB, B: 1 to 12GHz, power<br />

handling 10 W, antenna factor 25 - 44dB. Complete with tripod.<br />

AH Systems SAS-200/550-2B 100Hz to 60Mhz Rod Antenna<br />

AH,SAS-200/550 (1837)<br />

AU<br />

Monopole rod antenna. Frequency range 100Hz to 60MHz. Active unit with<br />

battery power. Rod height 220mm to 1.09m. Ground plane 450 x 450mm.<br />

Antenna factor 0 to 24.<br />

COM Power Double Ridged Horn Antenna 1 to 18GHz<br />

COM,AH-118<br />

MY<br />

Frequency range 1 to 18GHz, VSWR 2.0:1, Polarization: Linear, Output<br />

Impedance: 50Ω, connector types Antenna output: N (f).<br />

RF Accessories<br />

RF Cables - Various Lengths and Connectors<br />

TR,RF-CABLES (2817)<br />

RF cables. Various lengths and connectors<br />

RF Connector Kit N, BNC, TNC, SMA, APC7<br />

TR,RF-CONN (2816)<br />

AU<br />

RF connection adaptors. Comprises couplers with interchangeable<br />

connectors; DIN 7/16, N Type, BNC, SMA, TNC, APC-7 and UHF<br />

Huber & Suhner Sucoflex 104PE 26.5GHz RF Cable<br />

SUH,SUCOFLEX-104PE<br />

MY<br />

Fexible high performance microwave cable with frequency range up to<br />

26.5GHz. Length 1.0 meter and comes with 3.5mm connectors.<br />

AU<br />

IRIDIUM - THE TRUE GLOBAL<br />

SATELLITE PHONE<br />

NEED TO BE REACHED WHEN YOU’VE GONE BUSH<br />

AND OFF THAT BEATEN TRACK?<br />

Well you can keep in touch regardless of terrain when you take<br />

advantage of a rental satellite phone from TR Hirecom.<br />

So for your next adventure, have fun keeping in touch and enjoy the<br />

peace of mind a satellite phone on the Iridium Network gives you.<br />

Satellite phones are available for short or long term rental periods.<br />

4 MONTH CASUAL<br />

PLANS AVAILABLE<br />

hirecom<br />

telecom<br />

TO PURCHASE CALL<br />

1300 550 014<br />

TO RENT CALL<br />

1800 222 327<br />

TS0124<br />

19


Data & Telecommunications<br />

www.techrentals.com.au<br />

LAN Cable Testers<br />

LAN/WAN Analysers<br />

PDH/SDH Analysers<br />

DSL/POTS Test Set<br />

Light Sources & Power Meters<br />

Fusion Splicers<br />

OTDR & Fibre Inspection<br />

Fibre Optic Launch Cables & Patch Leads<br />

LAN Cable Testers<br />

Fluke DTX1800 Cable Analyser<br />

900MHz Cat 7<br />

FLU,DTX1800 (3260)<br />

AU/MY<br />

Category 7 cable certification tester up to 900MHz.<br />

Tests to Category 3, 4, 5, 5E, 6, 6a and 7. Cable analyser<br />

for use with shielded and unshielded twisted pair Cat 6<br />

Autotest time of 12 seconds. Linkware PC software, and<br />

USB cable included. Internal memory stores results.<br />

Optional multimode & single mode OTDR module.<br />

Fluke DTX-MFM2 Multimode<br />

Fibre Adaptor for DTX Cable<br />

Analyser<br />

FLU,DTX-MFM2 (3270)<br />

AU/MY<br />

DTX1200/1800 multimode fibre interface. Tests<br />

fibre installations in local area networks. Fits in<br />

the slot on the back of DTX cable analyser (standard copper cable adaptors<br />

can be connected but not used simultaneously). Provides fibre testing and<br />

certification. Bi-directional testing at 850nm & 1300nm at the same time.<br />

Measures optical power loss, length, and propagation delay for multimode<br />

fibres. Pass/fail results based on common fibre standards. Includes in built<br />

visual fault locator. (VFL).<br />

Fluke DTX Compact OTDR SM-MM<br />

FLU,DTX-OTDR (3280)<br />

AU<br />

Full featured multimode & single mode OTDR<br />

module that snaps onto a DTX Cable Analyser. Shoots and<br />

analyses traces on single mode 9nm and multimode 62.5<br />

& 50nm fibre.<br />

Fluke DTX Permanent Link Adaptor Analyser<br />

FLU,DTX-PLA (3295)<br />

Fluke PLA001 Permanent Link Adaptor.<br />

Fluke DTX-SFM2 Single<br />

Mode Fibre Adaptor for<br />

DTX Cable Analyser<br />

FLU,DTX-SFM2<br />

AU/MY<br />

DTX1200/1800 single mode fibre interface.<br />

Use for testing fibre installations in local area networks. Fits in the slot<br />

on the back of DTX cable analyser (standard copper cable adaptors can<br />

be connected but not used simultaneously). Provides fibre testing and<br />

certification. Bi-directional testing at 1310nm and 1550nm at the same<br />

time. Measures optical power loss, length, and propagation delay for single<br />

mode fibres. Pass/fail results based on common fibre standards. SC optical<br />

connectors. Includes in built visual fault locator. (VFL)<br />

AU<br />

LAN Cable Testers cont’d.<br />

LAN/WAN Analysers<br />

Fluke Siemon Tera Class F Cat 7 Adaptor Kit<br />

FLU,DTX-TERA KIT (3285)<br />

AU<br />

Includes 2 TERA channel adaptors and 2 TERA<br />

permanent link adaptors to test Siemon TERA<br />

class F, Cat 7 systems.<br />

EXFO AXS-200-850 Ethernet Test Set<br />

EXF,AXS-200_850 (3228)<br />

AU<br />

Two AXS-200/850(s) for installing, tuning up or maintaining<br />

Ethernet and IP services up to 1Gbit. Bidirectional RFC 2544<br />

testing. Applications include performance assessment of<br />

Carrier Ethernet services, activation and maintenance of<br />

metro Ethernet networks, deployment of active Ethernet<br />

(point-to-point) access services, traffic generation and<br />

monitoring for network performance testing Bit-error-rate testing (BERT)<br />

up to layer 4. Pass/fail results with user-defined thresholds. QoS, ToS and<br />

diffserv capabilities. Copper and SM & MM fibre interface supplied.<br />

EXFO ETS-1000L 10/100/1000 Ethernet Loopback<br />

EXFO,ETS-1000L<br />

MY<br />

Ethernet/Gigabit ethernet loopback unit ETS-1000L is intended for performing<br />

loopback at the physical, data link, network and transport layers of the OSI<br />

model. It allows carrying out loopback control via OAM protocol and remote<br />

control via TELNET protocol.<br />

EXFO FTB-860G NetBlazer<br />

10G Ethernet Tester<br />

EXF,FTB-860G (3223)<br />

AU<br />

Performs 10 Gbps RFC 2544 measurements<br />

and EtherSAM (ITU-T Y.156sam), for turnkey<br />

deployment, validation, and troubleshooting of<br />

access and metro ethernet services. IPv6 testing<br />

capabilities BERT, RFC, traffic gen and through mode. NetBlazer offers<br />

GUI navigation, dedicated quick-action buttons, and clear notifications for<br />

accurate interpretation of test results.<br />

Fluke Networks Etherscope II Gigabit LAN<br />

Analyser<br />

FLU,ETHERSCOPE-EX (3226)<br />

AU<br />

10M/100M/1Gigabit Copper, Fibre and WLAN a/b/g<br />

network analyser. Discover network elements and<br />

fault location even in a switched environment. IP<br />

analysis of Carrier Ethernet services. VLAN<br />

discovery, connected host details and trending data. Document and report<br />

network performance. View detailed information about RF signal strength, APs,<br />

SSID, channel information and more. Cable ID accessory for tracking cable<br />

routes included.<br />

Fluke Optiview Pro Gigabit 10/100/Gigabit<br />

LAN Analyser<br />

FLU,OPTIVIEW-GIG (3227)<br />

AU<br />

Provides network analysis on 10/100/Gigabit<br />

ethernet networks (multimode fibre & copper).<br />

Features active discovery in switched networks,<br />

full 7 layer analysis, ITO (Internetwork Throughput<br />

Option), trace switch route, free string match,<br />

reporting and documenting, address-to-name<br />

mapping, packet capture and decode, SNMP device analysis, RMON II traffic<br />

analysis, application level traffic analysis and much more.<br />

20


www.techrentals.com.au<br />

Data & Telecommunications<br />

LAN/WAN Analysers cont’d.<br />

JDSU SmartClassEthernet<br />

10M-1G Ethernet Tester<br />

JDSU,SMARTCLASS-ETH (3220)<br />

AU/MY<br />

Two SmartClass Ethernet(s) provided for comprehensive<br />

installation, turn up and maintenance of Ethernet IP<br />

services up to 1 Gbit. Performs Bidirectional RFC<br />

2544, Asymmetric RFC and multiple streams testing.<br />

Applications include performance assessment of<br />

Carrier Ethernet services, activation and maintenance of<br />

metro Ethernet networks, deployment of active Ethernet<br />

(point-to-point) access services, traffic generation and<br />

QoS verification.<br />

PDH/SDH Analysers<br />

JDSU ANT 5 SDH/PDH Access Tester<br />

JDSU,ANT5-STM4 (3445)<br />

AU/MY<br />

Field tester for the installation, commissioning<br />

and fault finding of fibre and copper SDH/PDH<br />

networks. Electrical interfaces for PDH/SDH: E1,<br />

E3, DS3, E4, STM-0e/1e; Optical interfaces for<br />

SDH/SONET: STM-1/OC-3, STM-4/OC-12. BERT,<br />

round trip delay measurement, error performance<br />

analysis: G.821, G.826, G.828, G.829, M.2100,M.2101 and ANSI. Autoconfig<br />

functionality for automatic traffic detection, line rate, structure and mapping.<br />

Offline Viewer SW provides result analysis and report generation.<br />

PDH/SDH Analysers<br />

JDSU ANT 5 SDH/PDH Access Tester<br />

JDSU,ANT5-STM16 (3446)<br />

AU/MY<br />

SField tester for the installation, commissioning and fault finding of fibre and<br />

copper SDH/PDH networks from 1.5Mb/s to 2.5 Gb/s. Optical testing at dual<br />

wave lengths at STM-1, STM-4, and STM-16. Electrical testing at DS1/E1/E3/<br />

DS3/E4 and STM-1 interfaces. Full analysis of concatenated mappings. ATM<br />

analysis for service verification of ATM and 3G/UMTS networks.<br />

JDSU/Acterna ANT 20 SDH/PDH Analyser<br />

JDSU,ANT20 (3465)<br />

AU<br />

Interfaces for PDH data streams at 2, 8, 34, & 140Mbps,<br />

electrical and optical interfaces for SDH at STM1<br />

(155Mbps). Jitter and wander generators and analyser<br />

options are fitted. Internal PC with FDD for transferring<br />

results. Serial, parallel, keyboard and pen interfaces.<br />

JDSU EDT-135 E1 and Data Tester<br />

JDSU,EDT-135 (3450)<br />

AU/MY<br />

Field service tester for commissioning,<br />

maintenance and troubleshooting of E1<br />

PCM2Mbps and V.11/RS-442, V.24/RS-232,<br />

V.35,V.36/RS-449, EIA-530 data circuits<br />

operating at 50bps to 2Mbps. Provides framed<br />

& unframed monitoring, end-to-end testing, drop<br />

& insert, channel associated signalling; error & alarm analysis, S bit, NFAS<br />

& NMFAS monitoring & generation. Round trip delay measurement, G.821,<br />

G.826 & M.2100 quality of service measurements. Signal level measurement<br />

& primary multiplexer testing.<br />

Leave Nothing to Chance<br />

Flawless FTTx service turn-up. IP service certification on the fly.<br />

Clean, inspect, analyze, test and certify—with a single tool.<br />

› Powerful FTB-1 platform<br />

› Large 7” color display<br />

› Fiber inspection probe<br />

› Automated connector endface<br />

analysis software<br />

› Integrated optical power meter<br />

› Visual fault locator<br />

› Complete suite of IP service test<br />

functions<br />

› Connector cleaning supplies<br />

The intelligent fiber inspection and<br />

certification test kit


Data & Telecommunications<br />

www.techrentals.com.au<br />

PDH/SDH Analysers cont’d.<br />

Acterna MTS 8000/T-BERD Transport<br />

Module<br />

JDSU,MTS8000<br />

MY<br />

Multirate interface for PDH-DS1/DS3/<br />

E1/E3/E4,STS-1 OC-3/12/48/48, STM-<br />

1e/1/4/16 and interface for OC-192 STM-<br />

64 with the ability to monitor down to the<br />

STS-1 level inside of any supported optical<br />

rate. Used for verifying and qualifying the performance of SDH and Gigabit<br />

ethernet, telecommunications networks. Electrical and optical interfaces at<br />

rates 1310/1550nm). Also supports the NewGen (ethernet over Sonet/SDH)<br />

and able to perform RFC2544. Ethernet IP testing with 10/100/100Mbps<br />

electrical RJ-45 Interfaces. Supports VLAN, Q-in-Q,VPLS,MPLS Tunnelling<br />

application. Comes with touch screen GUI operation. Measures optical power<br />

and frequency. Floppy drive installed.<br />

JDSU SmartClass E1/Datacom Tester<br />

JDSU,SMARTCLASS (3440)<br />

AU/MY<br />

Handheld field tester for the installation<br />

and commissioning of E1 and Datacom services.<br />

Applications include (not limited to), G.703 - 2Mb/s<br />

testing, 2 M (Bulk), n x 64kb/s BERT, audio monitoring<br />

(VF drop & insert),ABCD/Sa monitoring,<br />

alarms (defects) and errors (anomalies) insertion,<br />

round-trip delay, DTE / DTE emulation and monitor<br />

mode. Interfaces with X.21, V.24 (RS-232), V.35, V.36<br />

(RS-449), and EIA-530.<br />

Sunrise SunLite E1 Tester<br />

SUN,SUNLITE E1<br />

MY<br />

World’s smallest 2Mbps telecom network tester. Performs and stores a<br />

variety of vital tests. Bright LED indicators provide immediate circuit status,<br />

and internal speaker/microphones provide talk and listen capabilities. Power<br />

options include charger with two AA rechargeable batteries. 2.048Mbps<br />

transmit, receive and external clock. Bit error rate testing (ITU-T G.821).<br />

ITU-T G.826, M.2100 analysis.<br />

VeEX VePAL TX130/e+ DSn/PDH<br />

Ethernet Analyser<br />

VEEX,TX-130M+<br />

MY<br />

Full-featured mobile backhaul test solution supporting<br />

legacy PDH/DSn, Carrier Ethernet technologies, and<br />

Synchronized Packet networks. Capable of emulating<br />

both Master and Slave clocks according to ITU-T<br />

G.8261 SyncE and IEEE 1588v2 standards, which<br />

is particulary useful for carriers since either or one<br />

or both of these protocols can be implemented in the<br />

mobile network or cell site depending on deployment<br />

scenario. Mobile operators in the process of migrating their networks from<br />

legacy TDM to Packet-based backhaul will benefit from the range of DSn/PDH<br />

and Ethernet interfaces and powerful test features available on the TX130M+<br />

tester. <strong>Tech</strong>nicians now only need to carry one small portable unit to the field<br />

to validate transmission over copper and optical fiber connections including all<br />

the sophisticated functions of new synchronization technologies.<br />

VeEX VePAL TX130/e+ DSn/PDH Ethernet Analyser<br />

VEE,TX130<br />

MY<br />

Offers a single, multifunctional access network<br />

diagnostic tool. Equipped with PDH/DSn and Datacom.<br />

Performs traditional ITU-T/ANSI transmission tests<br />

required by large telcos and wireless/mobile operators,<br />

Datacom tests for networks operating “V” type interfaces.<br />

Designed for field engineers that need an easy-to-use,<br />

handheld and battery-powered field unit. To simplify and<br />

ensure rapid testing, the unit auto-configures itself to the<br />

signal detected, minimizing operator involvement.<br />

DSL/POTS Test Set<br />

Line and DSL Test Set<br />

FLU,990DSL 2/2+ (3470)<br />

AU<br />

CopperPro broad range Plain Old Telephone<br />

Services (POTS) troubleshooting, fault<br />

location and line qualification capabilities. Includes<br />

Wideband/TDR option which adds high frequency<br />

transmission testing and qualification functions for<br />

services like ADSL 2/2+, VDSL, HDSL, HDSL2 & 4, ISDN,<br />

T1, E1 and DDS. TDR feature adds precise fault location<br />

and analysis. Includes TN2100 remote terminator.<br />

Light Sources & Power Meters<br />

EXFO PPM-350B-EG PON Power Meter<br />

EXFO,PPM350B<br />

MY<br />

OptimiSed for FTTx E & GPON. PPM350B has 10 user-definable<br />

threshold sets, each set consisting of three wavelengths (1310, 1490 and<br />

1550 nm) having their own pass/warning/fail analysis features. Simultaneous<br />

measurement and display of all PON signals voice, data and video.<br />

EXFO PON/FTTx Power Meter & Inspection Probe<br />

EXF,PPM352_FIP400 (3370)<br />

AU<br />

Kit includes PPM-352B-EG-ER optimized for FTTx E<br />

& GPON & FIP-400 inspection probe with handheld<br />

display. PPM352 has 10 user-definable threshold sets, as<br />

well as pass/warning/fail analysis features. Simultaneous<br />

measurement and display of all PON signals voice, data and<br />

video.<br />

Fluke FTK1000 Multimode Fibre<br />

Optic Light Source & Meter<br />

FLU,FTK1000 (3365)<br />

AU<br />

Light source is multimode 850nm and 1300nm.<br />

Power meter has 850/1300nm multimode and<br />

1310/1550nm single mode. Manage results and<br />

print reports via Power meter memory, PC and<br />

supplied software.<br />

Fluke FTK150 Optical Fibre<br />

Light Source/Meter<br />

FLU,FTK150 (3366)<br />

AU<br />

Fibre test kit. Light source is multimode 850nm and<br />

1300nm. Power meter has calibrated measurements<br />

at 850/1300nm multimode and 1310/1550nm single<br />

mode. +3dBm to -55dBm measurement range with<br />

0.01dB resolution. Manage results and print reports<br />

via Power meter memory, PC and supplied software.<br />

Supplied with various connectors and patch leads.<br />

JDSU/Acterna OLA-55 Single Mode Optical Attenuator<br />

JDSU,OLA-55<br />

MY<br />

Adjustable wavelength from 1260 to 1650nm (1nm increments).<br />

Calibrated wavelengths 1310nm, 1550nm & 1625nm. Maximum<br />

permitted level =23dBm. Optical Interface: FC-PC.<br />

JDSU OLSP-55 Optical Laser Source<br />

JDSU,OLS-55<br />

MY<br />

Operates on dual wavelength of 1310nm and 1550nm. Output power is from -7<br />

to 0 dBm. Optical Interface: FC-PC.<br />

22


www.techrentals.com.au<br />

Data & Telecommunications<br />

Light Sources & Power Meters<br />

cont’d.<br />

JDSU Single Mode OLS OLP-35 Light<br />

Source & Power Meter<br />

JDSU,OLS-OLP 35 (3361)<br />

AU<br />

Light source (OLS-35) and power meter (OLP-35)<br />

fibre optic test set for single mode applications 1310<br />

and 1550nm. OLS-35 has interchangeable FC, SC<br />

and LC adapters and -7dBm power output. OLP-<br />

35 has universal 2.5 and 1.25mm connectors, auto<br />

wavelength detection, internal data storage and report<br />

software included.<br />

Kingfisher 73410 2 Way<br />

Loss Test Set with Optical Return Loss<br />

KIN,KI73410_LTS (3358)<br />

AU<br />

Included are two KI73410 for bi-directional two-way<br />

Insertion and Optical Return Loss testing at 1310, 1550<br />

and 1625nm with angled connectors. LTS are used to test<br />

cabling losses and single operator pass/fail operation in<br />

a PON type environment. Average fibre optic link loss and ORL from each<br />

end is automatically displayed in real time on both instruments, at multiple<br />

wavelengths via a single fibre. Applications include fibre optic attenuation,<br />

system power, ORL and Fibre Characterisation.<br />

Kingfisher KI78010 Single Mode APC<br />

Light Source and KI7600 Power Meter<br />

KIN,KI78010-7600 (3360)<br />

A U<br />

Light source (KI78010) and power meter (KI7600)<br />

optical fibre test set for single mode network and<br />

DWDM testing at 1310, 1550 and 1625nm. LS<br />

(KI78010) has Angled SC, FC and ST interchangeable<br />

connectors. PM (KI7600) with InGaAs detector has<br />

large user memory and flexible real-time PC reporting software. Autotest<br />

provides automatic multi wavelength loss testing. Power meter can be used for<br />

multiple single and multimode wavelengths.<br />

Kingfisher KI7822B- KI7600A Single<br />

Mode Light Source & Power Meter<br />

KIN,KI7822B-7600A (3362)<br />

AU<br />

Light source (KI7822B) and power meter (KI7600A)<br />

optical fibre test set for single mode applications<br />

(1310nm and 1550nm). Power meter has large user<br />

memory and flexible real-time PC reporting software.<br />

Autotest provides automatic multi wavelength loss<br />

testing. The meter displays mW, μW, nW, dB, dBm to 0.01dB resolution, with<br />

no range changing delays. Power meter can be used for multiple single and<br />

multimode wavelengths. Laser output power 0dBm.<br />

Kingfisher KI7827 Single Mode APC<br />

Light Source and KI7600 Power Meter<br />

KIN,KI7827-7600 (3364)<br />

AU<br />

Light source (KI7827) and power meter (KI7600)<br />

optical fibre test set for single mode applications such<br />

as FTTH (1310, 1490 and 1550nm). LS (KI7827) has<br />

Angled SC, FC and ST interchangeable connectors.<br />

PM (KI7600) with InGaAs detector has large user<br />

memory and flexible real-time PC reporting software. Autotest provides<br />

automatic multi wavelength loss testing. Power meter can be used for multiple<br />

single and multimode wavelengths.<br />

Fusion Splicers<br />

Fitel S123M12 Ribbon Fusion Splicer<br />

FIT,S123M12 (3322)<br />

AU<br />

Hand-held fusion splicer, can splice from 1 to a<br />

maximum of 12-ribbon fibre. Protection sleeve shrink<br />

time is 35 seconds for ribbon fibre sleeve, while splicing<br />

requires only 15 seconds for 8 or 12 ribbon fibre<br />

allowing up to 160 splicing cycles (splicing/heating)<br />

using the 2 battery packs installed in the main body.<br />

Fitel S178 Fusion Splicer and S325 Cleaver<br />

FIT,S178_S325 (3325)<br />

AU<br />

S178 hand-held, core-alignment fusion splicer and<br />

S325 cleaver. Splicer provides typical losses of 0.02dB<br />

& 0.01dB on single & multimode fibre respectively. 7<br />

second splice time, built in heater and tension test.<br />

Can be operated from battery or AC source. Precision<br />

fibre cleaver can be used with single and multimode<br />

fibres and features a built in sharps collection bin that<br />

automatically stores fibre off-cuts.<br />

Fitel S325A Precision Fibre Cleaver<br />

FIT,S325A (3324)<br />

AU<br />

Can be used with precision splicers for single and multi<br />

mode fibres. Features a built in sharps collection bin which<br />

automatically stores fibre offcuts as each fibre is cleaved.<br />

Fitel Fusion Splicer & Cleaver Kit<br />

FIT,SPLICER-CLEAVER (3326)<br />

AU<br />

Contains the S177A splicer and S325A cleaver. Splicer<br />

provides typical losses of 0.02dB & 0.01dB on single<br />

& multimode fibre respectively. 9s splice time, built in<br />

heater & tension tester. Can be operated from battery<br />

or AC source. Precision fibre cleaver can be used with<br />

single & multimode fibres. Features a built in sharps<br />

collection bin which automatically stores fibre off-cuts.<br />

Fujikura FSM60S Splicer & CT30 Cleaver<br />

FUJ,FSM60S-CT30 (3328)<br />

AU/MY<br />

For splicing multimode & single mode optical fibre.<br />

Battery and mains operated. Features splice protection<br />

heater, detachable work table and arc-free calibration<br />

system. Includes CT30 fibre cleaver.<br />

OTDR & Fibre Inspection<br />

See also LAN Cable Testers on page 20<br />

Anritsu CMA4000 Single Mode OTDR<br />

ANR,CMA4000SM<br />

MY<br />

Includes mainframe and 1310/1550nm and 1625nm (38/40 & 39dB) single mode<br />

module (module part number TD-14M25003 Model 4453M). Instrument had built<br />

in FDD and supplied with SC/PC, FC/PC, and ST/PC connectors.<br />

Anritsu CMA 4500 Single &<br />

Multimode 5/25dB OTDR<br />

ANR,CMA4500SM-MM (3338) AU<br />

Single mode and multimode OTDR. Includes<br />

wavelengths multimode 850/1300nm (24/26dB)<br />

and single mode 1310/1550 (35dB). Single mode<br />

port is SC/APC. Ethernet, USB connectivity, 20GB<br />

HD and PS2 ports. Touch screen and hard key<br />

interfaces.<br />

23


Data & Telecommunications<br />

www.techrentals.com.au<br />

OTDR & Fibre Inspection cont’d.<br />

Anritsu CMA 5000 Single Mode<br />

43/45dB OTDR<br />

ANR,CMA5000SM-45 (3342) AU<br />

Single mode OTDR with SC/APC (angled) adaptor.<br />

1310/1550/1625 Dynamic range 43/45/43dB. +20<br />

dBm Meter and Light Source and VFL (Visual Fault<br />

Locator). OTDR has built in CD-R/W and 20GB hard drive. Dedicated touch<br />

screen and hard key user interfaces. Mains and battery operation, battery life >3<br />

hours. 10/100MB Ethernet port for network connectivity. USB ports.<br />

Anritsu MT9083B Access Master<br />

Single Mode ODTR<br />

ANR,MT9083B (3336)<br />

AU<br />

Complete testing of PON-based FTTx networks<br />

featuring up to 1x64 splits or single fibre runs.<br />

1310, 1550 and 1625nm wavelengths. Intelligent<br />

analysis software identifies problem splices, connectors and even macrobends.<br />

Dynamic range up to 42dB. Active fibre verification. Store up to 1,000 traces in<br />

internal memory and up to 30,000 via your USB device.<br />

Fluke Optifiber Pro Quad OTDR<br />

FLU,OPTIFIBER-PRO Q (3344) AU<br />

Multi and singlemode OTDR.<br />

Designed for testing, troubleshooting and certifying multi<br />

and singlemode 62.5, 50 and 9μm fibre optic networks.<br />

Wavelengths 850, 1300, 1310 and 1550nm. Smartphone<br />

user interface, shortest event and attenuation deadzones,<br />

LinkWare download and reporting software included.<br />

Fluke Optifibre Single Mode OTDR<br />

FLU,OPTIFIBER-SM (3345)<br />

AU<br />

Single mode OTDR designed for testing,<br />

troubleshooting and certifying network fibre optics at<br />

1310/1550. Equipment has SC interface and VFL.<br />

Typically, 60Km range for 1310/1550nm, event dead<br />

zone 1m and attenuation dead zone 8m. Battery<br />

operated, launch lead and LinkWare download and<br />

reporting software included.<br />

OTDR & Fibre Inspection cont’d.<br />

JDSU Fibre Inspection-Capture Probe<br />

JDSU,FIBER_INSPECT (3340)<br />

AU<br />

Handheld display, dual magnification (200/400x) probe<br />

and USB adaptor for fibre end-face image analysis and<br />

capture. Includes software and various probe tips.<br />

Fibre Optic Launch Cables & Patch<br />

Leads<br />

Launch Fibre Multimode 50μm 100m<br />

FIB,LAUNCH MM 50UM (3380)<br />

AU<br />

100 metres of 50μm fibre terminated with SC connectors.<br />

A launch fibre enables an OTDR to measure the loss<br />

of the first connector and adapts a 62.5μm OTDR to a<br />

50μm network.<br />

Launch Fibre Multimode 62.5μm 300m<br />

FIB,LAUNCH MM 62.5UM (3382)<br />

SC to SC multimode 62.5μm launch fibre.<br />

Launch Fibre Single Mode 9μm<br />

FIB,LAUNCH SM 9UM (3378)<br />

Single mode 9μm SC launch fibre.<br />

A range of fi bre optic consumables are available<br />

for sale. Please ask when you are placing<br />

your order for delivery with your equipment.<br />

AU<br />

AU<br />

RENTAL PURCHASE OPTION<br />

Our rental with purchase option scheme is available to approved business customers.<br />

Generally the rates quoted on the rental purchase option are based on a 12 month rental period<br />

after which you may purchase the equipment by paying an amount equal to month’s rental.<br />

However these plans can often be tailored to suit your particular timeframe requirements.<br />

The equipment listed in both our periodical email sales and most products in our rental fleet<br />

can take advantage of this option. If you have any questions about this scheme or the<br />

type of equipment that would apply please call our technical representatives to discuss your<br />

requirements.<br />

24


Electrical Power<br />

www.techrentals.com.au<br />

Cable & Pipe Tracers & Fault Locators<br />

Electrical Testers<br />

PAT Testers & RCD Testers<br />

Micro-Ohm Meters & Earth Testers<br />

Power Analysers & Recorders<br />

Current Clamps Probes & Accessories<br />

Insulation Testers & Meggers to 20kV<br />

Oil, Hipot & VLF Testers above 20kV<br />

Power Transformer Testers<br />

Current Injectors<br />

Protection Relay Testing Systems<br />

AC Sources/Inverters/Generators<br />

Power Transformers<br />

Power Line Conditioners/UPS<br />

Battery Management Systems<br />

Cable & Pipe Tracers<br />

& Fault Locators<br />

See also Ground Penetrating Radar on page 65<br />

See also Underground Services Location on page 65<br />

CScope CATXDSGV-KIT Cable and Pipe Locator<br />

CSC,CATXDSGV-KIT (3664)<br />

AU/MY<br />

Kit includes a generator with touch button controls and<br />

LCD display and an XD receiver/locator operating at<br />

33kHz. Operates in power or radio modes. Accessories<br />

include direct connection cable, ground stake and<br />

75mm diameter tong set. Transmitter operates by direct<br />

connection, or induction via the tongs. Determines<br />

cable depth, range 0.2m to 3m. Battery powered.<br />

Fluke Cable Locator<br />

FLU,2042 (3602)<br />

AU<br />

Ideal for tracing cables in walls and underground,<br />

locating fuses/breakers on final circuits and locating<br />

interruptions and short-circuits in cables and electrical<br />

floor heating systems. Can be used for tracing metallic<br />

water and heating pipes. Supplied as a kit comprising<br />

a transmitter and receiver in a carry case. Voltage<br />

measurement range 12 to 400 volts. Frequency range<br />

0 to 60Hz. Transmitter output signal 125kHz. Transmitter voltage 0 to 400V<br />

ac/dc. Depth location 0 to 2.5m. Receiver voltage detection range 0 to 0.4m.<br />

The receiver incorporates a torch for working in dimly lit locations.<br />

Save your time and reduce<br />

your real costs. Find out all<br />

about our Confi guration and<br />

<strong>Download</strong> solutions on page 43.<br />

Cable & Pipe Tracers<br />

& Fault Locators cont’d.<br />

Megger MPP1002 Cable Fault<br />

Pinpoint Locator<br />

MEG,MPP1002-FAULT PP (3603) A U<br />

PPinpoints faults in shielded and direct buried<br />

primary cables via Geophone probe(s). Can<br />

be used with any surge generator (thumper).<br />

Stand-alone unit measures electromagnetic surge<br />

and supplies the amplitude of that surge which aids in finding the fault. When<br />

fitted with probes the unit will detect the acoustic discharge (thump), measure<br />

the time delay between acoustic and electromagnetic signals and calculate<br />

the distance to fault. Using the dual probe system the direction to fault is<br />

indicated. Detects faults up to 23m away. Battery powered.<br />

Megger TDR20002RM Dual Channel TDR Cable Fault Locator<br />

MEG,TDR2000/2RM (3605)<br />

AU<br />

Time Domain Reflectometer cable fault locator. User selectable ranges from<br />

0 to 50m up to 20km, minimum resolution 0.1m. Dual cursor measurement.<br />

Internal memory for 15 traces. Megger “Tracemaster” software supplied.<br />

RS232 interface for PC communications. High resolution LCD display. Battery<br />

powered. Dust and shower proof to IP54.<br />

Riser Bond 1205T-OSP Metallic TDR Cable Fault Locator<br />

RB,1205T-OSP<br />

MY<br />

Dual input metallic time domain reflectometer cable fault locator for coaxial<br />

cables. Maximum Range: 63,700ft (19,400meters) at .990 VOP. Distance<br />

Accuracy: +/- 0.1ft (0.03m) plus +/- .01% of reading. Can Store, Recall and<br />

<strong>Download</strong> Waveform, via RS232 cable. (Viewable with Software.)<br />

Electrical Testers<br />

See also Current Clamps Probes & Accessories on page 33-35<br />

AVO Penta-Plus DMM Analyser<br />

AVO,PENTA-PLUS-DMM (3621)<br />

AU<br />

Portable battery/line operated multifunction instrument<br />

for measuring AC voltage, AC primary and secondary<br />

current, power, reactive power, phase angle and<br />

frequency of a single or three phase electrical system.<br />

Easily configured to measure the amplitude and phase angle between any two<br />

voltage and current inputs. All measured values are displayed simultaneously<br />

on a large display. Ranges; voltage 0 to 650V, current 0 to 100A, power +/-0 to<br />

100kW, reactive power +/-0 to 100kVAR. Resolution of above measurements<br />

0.1%. Phase angle 0 to 360 degree, resolution 0.1 degree. Frequency 45 to<br />

65Hz, accuracy +/-0.01Hz. Timer 0 to 999.999sec, accuracy +/-0.001sec.<br />

Memory records 60 test results. RS232 data and parallel printer output ports.<br />

CATU C-8-36 Phasing Stick - Two Pole Phase<br />

Comparator for Indoor Use<br />

CAT,CL-8-36 PH STICK (3622)<br />

AU<br />

Detects differences in voltage between any two<br />

points of an installation. Indication by LEDs.<br />

Voltage range 2kV to 36kV. Enables assessment<br />

of the order of magnitude of the residual voltage induced by nearby live lines<br />

or circuits, and thus differentiates it from the one provided directly from a high<br />

voltage source. Two 1.25m elements with removable probes, connected via a<br />

high-insulation lead. Maximum working distance 2.25m.<br />

Hioki 3283 Clamp on Leak HiTester<br />

HIO,3283 CLAMP ON-LT (3623)<br />

AU/MY<br />

Monitor leak current fluctuations. Bandwidth 5Hz to 15kHz.<br />

AC current range 10mA to 200A, resolution 10microA. Accuracy<br />

+/-1%. LCD display. Battery powered.<br />

26


www.techrentals.com.au<br />

Electrical Power<br />

Electrical Testers cont’d.<br />

Martindale Phase Sequence & Continuity<br />

Indicator 100 to 600V, 50/60Hz<br />

MAR,PSCI424-585 (3624)<br />

AU<br />

Check the presence and sequence of the phases on<br />

3ph circuits. Provides a visual indication of loss of<br />

phase or incorrect sequence. Supplied in 2 forms.<br />

Probe style; the connection to the tester is via 3<br />

insulated cables to 3 fused test probes, 1 with an<br />

insulated crocodile clip. Plug style; a 16A, 4 pin (3ph<br />

& earth, BS4343) plug is fitted to the tester. Use as<br />

a socket tester prior to plugging in 3ph equipment.<br />

PAT Testers & RCD Testers<br />

Megger LTW335 Fault Loop<br />

Impedance Tester<br />

MEG,LTW335-FLIT (2612)<br />

AU<br />

Non-tripping loop tester for single or phase to<br />

phase loop testing. Voltage range 50V to 550V,<br />

accuracy +/-2%, +/-2 digits. Enables testing on<br />

110V centre tapped supplies. Phase rotation<br />

indicator. Internal memory stores 1,000 test results. <strong>Download</strong> manager<br />

software supplied. USB interface for PC communications. High resolution LCD<br />

display. Battery powered. Dust and shower proof to IP54.<br />

Megger RCDT330 Residual Current Device Tester<br />

MEG,RCDT330 (2618)<br />

AU<br />

Tests standard, DC, selection and programmable RCDs. Ramp testing. Auto<br />

(remote) testing. Auto sequence test feature. 3ph safe. Enables testing on 110V<br />

centre tapped supplies. Performs 1/2I, 1xI & 50xI tests on RCDs rated at 10mA,<br />

30mA, 100mA, 300mA, 500mA & 1,000mA on general and selective (time<br />

delayed) RCDs. Weatherproof to IP54. USB interface for test results download.<br />

Metrel IT3017- Installation<br />

Tester for Testing to AS/<br />

NZS3000<br />

MET,IT3017INSTALTEST (2610)<br />

AU<br />

Multifunction installation tester with<br />

measurement functions and Pass/Fail<br />

limits set to AS/NZS3000 Wiring Rules, and<br />

storing of test results for printing compliance test reports. In-built Australian<br />

measurements and Pass/Fail limits, and guarantees accountability and<br />

traceability with storing of test results. Simply conduct the test, press the Memory<br />

button to save the result and assign the result to a location, then download<br />

results to PC software and print-out compliance test reports with actual test<br />

results. Earth Continuity & Resistance, Insulation Resistance, Polarity, Correct<br />

Circuit Connections, Fault Loop Impedance and RCD Testing. “Auto-Sequence<br />

Test” mode further speeds up compliance testing and reporting.<br />

Seaward PAC 3760 Appliance Checker<br />

SEW,PAC3760 (2605)<br />

AU<br />

Performs the following tests in conformance to AS/NZS<br />

3760:2000, earth bond, insulation & polarity tests, also<br />

leakage current tests for Class I & Class II appliances and<br />

leads (leakage current testing of appliances, which requires<br />

power to “switch” them on, is the method required by AS/<br />

NZS3760: 2003). Simple pass/fail indication. Unique 3<br />

button operation. Class I, class II andleakage current.<br />

Automatic test sequence senses an IEC or extension lead then performs a<br />

polarity test. Detects that the appliance under test is switched “On”. Earth bond<br />

test is set at 10A and is capable of fusing a poor earth.<br />

PAT Testers & RCD Testers cont’d.<br />

Seaward ProTag OPTIMA-300 Testing<br />

and Tagging System<br />

SEW,PT-300 (2603)<br />

AU<br />

Comprises the Seaward PrimeTest 300 appliance and<br />

RCD tester, ProTag Optima test tag printer and the BCS-<br />

Blue bar code scanner. Battery powered, weighs around<br />

2kg. Carries out all of the tests required under AS/NZS3760<br />

for appliances and leads, and 30mA RCD tests. Operates<br />

as a handheld data logging device by recording any type<br />

of test, inspection or risk assessment with user defined<br />

inspection routines and an in-built library of measurement<br />

and engineering units for recording actual results.<br />

Seaward Supernova XE3760+<br />

PAT System with Printer and<br />

Scanner<br />

SEW,XE3760PKIT+ (2600)<br />

AU/MY<br />

Includes results label/tag printer and barcode<br />

scanner. Performs all AS/NZS3760:<br />

2001/2003 compliant tests, including class<br />

1 & class 2 leakage current 5mA/1mA, an<br />

earth conductor bond test up to 25A at 3V<br />

(approx. 100W) and 250VDC MOV insulation<br />

resistance tests. Stores 5,000 tests in internal memory by appliance ID,<br />

including test type, detailed results, test time & date,<br />

next test due date, site & location. Calibrated resolution better<br />

than the required 5% of full scale across all ranges as specified by<br />

the Standard. Full QWERTY keyboard, and bar code reader for input.<br />

Durable plastic adhesive test label/tags printed to attach to<br />

appliances and leads includes user ID (logo optional on request) and test<br />

barcode ID, saves transcription. Compatible with Seaward PATGuard plus<br />

software package.<br />

Micro-Ohm Meters & Earth Testers<br />

CHK LM05 Micro-Ohm Meter 10A<br />

CHK,LM05 (2631)<br />

AU/MY<br />

Maximum test current 10A. Resistance range up to 20Ω with a maximum<br />

sensitivity of 1μΩ. Duplex helical test leads 2m long. Operates from internal<br />

batteries or external power supply. Includes power supply/charger, duplex<br />

helical test leads, length 2m.<br />

Fluke 1623 KIT GEO Earth Ground<br />

Tester<br />

FLU,1623-KIT (8435)<br />

AU<br />

Perform all four types of earth ground<br />

measurement; 3 and 4-pole (Fall of Potential)<br />

and 4-pole soil resistivity testing (using stakes).<br />

Selective testing (using 1 clamp and stake).<br />

Measuring range 0.001Ω to 19.99kΩ. Stakeless<br />

testing (using 2 clamps only), measuring range<br />

0.001Ω to 199.9Ω. LCD display. Battery powered.<br />

Fluke 1625 KIT GEO Earth Ground Tester<br />

FLU,1625-KIT (2650)<br />

AU<br />

Perform all four types of earth ground measurement; 3 and 4-pole<br />

(Fall of Potential) and 4-pole soil resistivity testing (using stakes). Selective<br />

testing (using 1 clamp and stake). Measuring range 0.001Ω to 19.99kΩ.<br />

Stakeless testing (using 2 clamps only), measuring range 0.001Ω to 199.9Ω.<br />

Includes automatic frequency control to minimise interference effects. LCD<br />

display. Battery powered.<br />

27


www.techrentals.com.au<br />

Electrical Power<br />

Micro-Ohm Meters & Earth Testers<br />

cont’d.<br />

Fluke 1630 Earth Ground Clamp<br />

FLU,1630-EARTH CLAMP (2651)<br />

AU<br />

Earth ground loop testing and continuity testing without<br />

breaking the circuit. Ground loop resistance range 0.025Ω to<br />

1.5KΩ. Ground leakage current measurement range 0.2mA<br />

to 1000mA. Current measurement range 0.2A to 30A. Logs<br />

and stores measurements for on screen recall. LCD display.<br />

Battery powered.<br />

Fluke Clamp for Ground Loop Resistance<br />

around Power Pylons<br />

FLU,EI-162BN (2652)<br />

AU<br />

Split core transformer designed to work with the Fluke<br />

1623 and Fluke 1625 earth ground testers to make<br />

selective earth ground loop resistance measurements<br />

on power pylons. Inner diameter of the clamp is 310mm.<br />

Megger High Accuracy<br />

Configurable Diagnostic Earth<br />

Tester<br />

MEG,DET2/2 (2653)<br />

AU<br />

Provides a wide resistance range from 0.01Ω<br />

to 19.99kΩ for testing larger or more complex<br />

grounding systems and for difficult testing<br />

environments, with ±0.5% accuracy and 0.001Ω resolution. Microprocessor<br />

control and advanced filtering simplify testing in environments with high levels<br />

of interference.<br />

Megger DET20C Digital Earth Test Clamp<br />

MEG,DET20C (2654)<br />

AU<br />

Measures ground resistance from 25mΩ to<br />

1,500Ω. Measures ground leakage current from 200μA to<br />

35A. Automatic self calibration. Auto ranging. High and low<br />

alarms. Large memory. <strong>Download</strong> to Megger <strong>Download</strong><br />

Manager. Measures earth resistance in installations such<br />

as buildings, pylons and RF transmitter sites. Use for the<br />

inspection and verification of lightning protection systems.<br />

Large jaw opening.<br />

Megger DET4TC2 Digital Earth Tester With Kit<br />

MEG,DET4TC2<br />

MY<br />

Measurement range of 0.010Ω to 200kΩ, ground<br />

noise voltage measurement from 1V to 100V and<br />

ground current from 1mA to 20A. Accurate results<br />

can be obtained in electrically noisy environments<br />

since it is capable of rejecting noise voltages of 40V<br />

peak to peak and the user can select different test<br />

frequencies to minimise the effect of interference. Powered from 8 AA batteries.<br />

Supplied with ICLAMP augments the traditional fall-ofpotential measurement<br />

method with ART (Attached Rod <strong>Tech</strong>nique) which allows electrode testing<br />

without disconnection and also leakage current measurements down to 1mA.<br />

The VCLAMP enables true stakeless measurements to be made in situations<br />

where driving stakes is not practical.<br />

Megger DLRO10 Micro-Ohm Meter<br />

MEG,DLRO10 (2633)<br />

AU<br />

Self contained fully automatic micro-ohmmeter, selecting the most suitable<br />

test current up to 10Adc. Range 0.1μΩ to 2kΩ, resolution 0.1μΩ. LED<br />

display. Rechargeable battery.<br />

Micro-Ohm Meters & Earth Testers<br />

cont’d.<br />

Megger DLRO10X Digital Low Resistance Ohm<br />

Meter 10A/0.1μΩ-2KOhm<br />

MEG,DLRO10X (2634)<br />

AU/MY<br />

Self contained fully automatic (with manual option)<br />

micro-Ohmmeter, selecting the most suitable test<br />

current up to 10Adc. Range 0.1μΩ to 2kΩ, resolution<br />

0.1μΩ. Internal memory for 700 tests. <strong>Download</strong><br />

software supplied. RS232 communications to PC. LCD<br />

display. Rechargeable battery.<br />

Megger DLRO200 200A Micro-Ohm Meter<br />

MEG,DLRO200 (2636)<br />

AU<br />

Test current range 10A to 200Adc. Measurement<br />

range 0.1mΩ to 1Ω, resolution 0.1mΩ. Current<br />

cables 2 x 5m. Internal memory for 300 tests. <strong>Download</strong><br />

software supplied. RS232 communications to<br />

PC. LCD display.<br />

Megger DLRO600 Digital Micro-Ohm Meter<br />

- High current<br />

MEG,DLRO600 (2637)<br />

AU/MY<br />

Test current range 10A to 600Adc. Measurement<br />

range 0.1μΩ to 1Ω, resolution 0.1μΩ. Current cables<br />

2x5m. Internal memory for 300 tests. <strong>Download</strong><br />

software.<br />

Megger DLRO Wind Turbine Lightning<br />

Protection Test Lead Set<br />

MEG,DLRO-100LEAD (2640)<br />

AU<br />

For Megger DLRO 10 series digital microohm meters.<br />

Specially designed for measuring resistance of lightning<br />

protection circuit between wind turbine blade tip and ground.<br />

Kelvin clip and hook ends on 100m cable reel. 5m DH2 lead<br />

with duplex hand spikes and hook end.<br />

Megger DLRO Lead Set Current & Voltage Leads<br />

MEG,DLRO-LEADSET (2641)<br />

AU<br />

For Megger DLRO digital micro-ohm meters potential spike lead set x2 and<br />

current clip lead set x2. Leads are used to separate the C & P connections.<br />

This avoids the erroneously high readings taken due to a high resistance<br />

contact. Current clip lead set 2m (242041-7) and Potential Spike set 2m<br />

(242021-7).<br />

Power Analysers & Recorders<br />

See also Current Clamps Probes & Accessories on page 33-35<br />

CCI Power-Mate 15A Single Phase<br />

Power/Energy Analyser<br />

CCI,POWER-MATE 15A (8701)<br />

AU<br />

Accurately measure and calculate power in watts, voltage,<br />

current and energy being used by an electrical appliance.<br />

Provides minimum, maximum and instantaneous readings.<br />

Determine the actual running cost, how much energy the<br />

appliance used in kWh and how many kg of greenhouse<br />

gas emissions it produced in hourly, yearly, quarterly and<br />

accumulated figures. LCD display. Rated to a maximum<br />

continuous capacity of 15A.<br />

29


Electrical Power<br />

www.techrentals.com.au<br />

Power Analysers & Recorders cont’d.<br />

CHK GridSense PowerMonic PM20 Power<br />

Quality Analyser<br />

CHK,PM20<br />

MY<br />

Three phase, weatherproof IP65 field unit. Three voltage<br />

channels 63V to 440V (isolated). Four current<br />

channels 0 to 3kA RMS (3ph & neutral). Supplied with<br />

3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA<br />

for large conductors and 500A for neutrals clamp-on<br />

CTs are available. Memory 4Mb. In-built 2 line LCD<br />

display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and<br />

tariffs, high speed RMS waveform capture events outside preset limits (10ms<br />

intervals). Software provides graphs and summaries to PC. <strong>Download</strong> files<br />

while logging. RS232 interface. PC using Win 95, 98 or NT4 O/S, is required<br />

with the CHK POWERview software to configure this unit before operating.<br />

CHK Gridsense Powermonic PM30<br />

Power Quality Analyser<br />

CHK,PM30 (8705)<br />

AU/MY<br />

Weatherproof IP65 field unit. Channels 3 voltage, 63V<br />

to 440V (isolated), 4 current 0 to 3kA (3ph & neutral)<br />

RMS. Supplied with 3 x 1kA clamp-on CTs (cable<br />

capacity 50mm). Clamp-on CTs of 3kA, 1kA for large<br />

conductors and 500A & 100A for neutral conductor<br />

current measurement are available. Memory 4Mb.<br />

In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics,<br />

(THD and individual to 48th). Total energy, tariffs, max demands, transient<br />

and sub-cycle disturbances. Software provides graphs and summaries to PC.<br />

<strong>Download</strong> files while logging via RS232 interface. PC using Win 95, 98, NT4,<br />

2000, XP, O/S, is required with the CHK POWERview software to configure<br />

this unit before operating.<br />

CHK GridSense PowerMonic PM30<br />

Plus Power Quality Analyser<br />

CHK,PM30PLUS (8706)<br />

AU/MY<br />

Weatherproof IP65 field unit. Channels: 3 Voltage,<br />

63V to 440V (isolated). 3 current 0 to 3,000A (3ph)<br />

rms. Supplied with 3 flexible 3,000A clamp-on<br />

CTs (flexible CT length 600mm and 190mmØ). (In<br />

addition, clamp-on CTs of 3,000A, 1,000A for large<br />

conductors and 500A and 100A for neutral conductor<br />

current measurement are available.) Memory: 4Mb.<br />

Inbuilt two line LCD display. Records: V, A, pf, f(Hz),<br />

kVA, kVAr, kW, harmonics, (THD and individual to 48th). Total energy, tariffs,<br />

maximum demands, transient and sub-cycle disturbances. Included software<br />

provides graphs and summaries to PC. <strong>Download</strong> files while logging RS-232<br />

interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required<br />

with the CHK POWERview software to configure this unit before operating.<br />

CHK GridSense PowerMonic PM35<br />

Power Quality Analyser<br />

CHK,PM35<br />

MY<br />

Power logger and disturbance analyser. Weatherproof<br />

IP65 field unit. 3 Voltage (55VAC to 520VAC) and<br />

4 current (0 to 3,000A) channels. Supplied with 4<br />

flexible 3,000A clamp-on CTs (flexible CT length<br />

600mm and 190mmØ). Memory: 15Mb. Inbuilt two<br />

line LCD display. Records: V, A, pf, f(Hz), kVA, kVAr,<br />

kW, harmonics, (THD and individual to 48th ). Flicker (Pst & Plt), Total energy,<br />

tariffs, maximum demands, transient and sub-cycle disturbances. Included<br />

software provides graphs and summaries to PC. download files while logging.<br />

High speed USB interface. A PC using Windows 95, 98, NT4, WIN2000<br />

or XP (Vista in compatability mode)O/S, is required with the software to<br />

configure this unit before operating.<br />

Power Analysers & Recorders cont’d.<br />

CHK GridSense PowerMonic PM40<br />

Power Quality Analyser<br />

CHK,PM40PQA (8708)<br />

AU<br />

Weatherproof IP65 field unit. Channels: 3 Voltage,<br />

63 to 440V (isolated). 4 current 0 to 3,000A (3ph<br />

and neutral) RMS. Supplied with 4 flexible 3,000A<br />

clamp-on CTs (flexible CT length 600mm and Diameter<br />

190mm). Memory: 15Mb. Inbuilt Graphic 128x64 bits<br />

LCD display, 7 rows x 20 characters. Records: V, A,<br />

pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics,<br />

voltage and current imbalance (THD and individual to 48th ) and Flicker. Total<br />

energy, tariffs, maximum demands, and transient and sub-cycle disturbances.<br />

Included software provides graphs and summaries to PC. <strong>Download</strong> files<br />

while logging USB interface. A PC using Windows 95, 98, NT4, WIN2000 or<br />

XP O/S, is required with the CHK PowerView software to configure this unit<br />

before operating.<br />

CHK GridSense PowerMonic PM45 Power<br />

Quality Analyser<br />

CHK,PM45 (8709)<br />

AU<br />

Suitable for low voltage investigations,<br />

power profiling and load studies, harmonic analysis,<br />

power factor studies & flicker and imbalance<br />

monitoring. Features IEC61010 Cat IV 600V safety<br />

certificate, weatherproof IP65 case, 4 channel<br />

voltage and 4 channels current. Supplied with 4 x<br />

Flexi F3000-6 clamps. VA,B & C 0 to 600VAC VGnd<br />

0 to 60VAC, Current input 0 to 3,000A.<br />

Dranetz-BMI Power Guide 4400<br />

DRA-BMI,PG4400 (8715) AU<br />

Provides the full range of<br />

measurements include V, I, W, VA, VAR, TPF,<br />

DPF, demand, energy, harmonics & interharmonics,<br />

THD, harmonics spectrum (V, I,<br />

W) to the 63rd, flicker (Pst, Plt), crest factor, K factor, transformer de-rating<br />

etc. Asset comes with AC flexible current clamp DRA-BMI,RR3035A/24,<br />

current range 30/300/3,000A AC only. Can be extended to different ranges<br />

of measurement AC/DC by selecting appropriate current clamps. Has the full<br />

range of arithmetic, vector and sequence parameters to evaluate distorted<br />

and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits<br />

of any active parameter can trigger logging. Voltage & current disturbances.<br />

DRA-BMI,PG4400 analysers can be used for power quality measurements,<br />

current inrush fault recording long term monitoring and continuous logging at<br />

1s intervals. DRA-BMI,PG4400 is Class A compliant with IEC Standard 61000-<br />

4-30, AS61000-4-7 and AS61000-4-15.<br />

Dranetz-BMI Power Xplorer PX5<br />

DRA-BMI,PX5 (8716)<br />

AU<br />

Provides the full range of measurements include<br />

V, I, W, VA, VAR, TPF, DPF, Demand, Energy,<br />

Harmonics & Inter-harmonics, THD, Harmonics<br />

spectrum (V, I, W) to the 63rd, Flicker (Pst,<br />

Plt), Crest factor, K factor, Transformer de-rating etc. Min/Max/Avg values<br />

are determined in 1/2 cycle RMS steps. Complete with A/C Flexible Current<br />

Clamp DRA-BMI,RR3035A/24, Current Range: 30/300/3,000A AC only. Can<br />

be extended to mentioned different ranges of measurement both AC/DC by<br />

selecting appropriate current clamps. High-speed transient capture (1MHz<br />

sampling rate). Pre-event and post-event waveform capture cycles are user<br />

adjustable. Can be used for power quality measurements, current inrush<br />

(cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage<br />

logging), long term monitoring and continuous logging at 1s intervals.<br />

Compliant with IEC Standard 61000-4-30 (Class A), AS61000-4-7 and<br />

AS61000-4-15.<br />

30


Calibration and Repair<br />

Aviation − Biomedical − Communications − Electrical<br />

Construction − Mechanical − Mining − Other<br />

Have all your calibration and repair needs covered,<br />

including major equipment manufacturers:<br />

• Fluke<br />

• Tektronix<br />

• Megger<br />

Your calibration can be provided with a<br />

NATA and/or Traceable calibration report.<br />

• Barfi eld<br />

• Anritsu<br />

• Plus many more…<br />

41 Enterprise Cct<br />

72 Donaldson Road<br />

Prestons NSW 2170<br />

Rocklea QLD 4106<br />

www.trvms.com.au 1300 790 480<br />

31<br />

VM0101


Electrical Power<br />

www.techrentals.com.au<br />

Power Analysers & Recorders cont’d.<br />

Fluke 1735 3-Phase<br />

Power Logger<br />

FLU,1735 (8737) AU/MY<br />

Measures single-phase to 3-phase 4-wire circuits,<br />

50/60Hz. 3 voltage inputs with common neutral rated<br />

600Vac (CAT III 600V). 4 current inputs, 4 flexible<br />

current probes (15A to 3000A) are included. Records voltage, current, power<br />

(P, Q & S), power factor, frequency, energy consumption, averaged demand,<br />

harmonics (odd up to 25th order), THD (voltage & current). Includes builtin<br />

batteries for up to 12 hours of recording, and includes Fluke Power Log<br />

software.<br />

Fluke VR1710 Single-Phase Voltage<br />

Quality Recorder<br />

FLU,VR1710 (8720)<br />

AU<br />

Single phase power quality analyser. Records RMS,<br />

transients, flicker & harmonics up to the 32nd. Selectable<br />

logging periods from 1s to 20min. Provides continuous<br />

recording with no gaps. Includes software for download,<br />

analysis and automatic reporting.<br />

Hioki 3169-21 Clamp-On<br />

Power HiTester with<br />

4 x 500A CTs<br />

HIO,3169-21 CT500AMP (8726) AU<br />

Measures voltage, current, power,<br />

power factor, harmonics and integrated<br />

values. Simultaneously performs demand<br />

measurements required for power management and energy-saving. Range<br />

0.05A to 500A. Includes 4 x clamp-on CTs. Supplied software provides graphs<br />

and summaries to PC. Flash card data storage. RS232 interface for PC<br />

communications.<br />

Power Analysers & Recorders cont’d.<br />

Hioki 3169-21 Clamp-On Power HiTester with 4 x 1,000A CTs<br />

HIO,3169-21CT1000AMP (8727)<br />

AU<br />

Measures voltage, current, power, power factor, harmonics and<br />

integrated values. Simultaneously performs demand measurements required<br />

for power management and energy-saving. Range 5A to 1000A. Includes 4<br />

x clamp-on CTs. Supplied software provides graphs and summaries to PC.<br />

Flash card data storage. RS232 interface for PC communications.<br />

Hioki 3169-21 Clamp-On Power HiTester<br />

with 4 x 5,000A FlexCTs<br />

HIO,3169-21CLAMPONPT (8728)<br />

AU<br />

Measures voltage, current, power, power factor, harmonics and integrated<br />

values. Simultaneously performs demand measurements required for<br />

power management and energy-saving. Range 5A to 5000A. Includes 4<br />

x flexible CTs, 500/5000A switchable. Supplied software provides graphs<br />

and summaries to PC. Flash card data storage. RS232 interface for PC<br />

communications.<br />

Hioki 3196 Power Quality Analyser<br />

with 4 x 5,000A Flex CTs<br />

HIO,3196-PQA (8729)<br />

AU/MY<br />

High speed field unit, measuring transient and<br />

sub-cycle disturbances, total energy, tariffs and max<br />

demand. Four voltage (150~600V RMS), and 4<br />

current (0 to 5kA), channels. Includes 4 x flexible CTs, 500/5000A switchable.<br />

Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, and flicker. Memory 512MB<br />

flash card. Colour display. Supplied software provides graphs and summaries<br />

to PC. RS232 or LAN interface for PC communications.<br />

QUALITY PRODUCTS<br />

QUALITY RESULTS<br />

PW3198 Power Quality Analyser<br />

3169-20 Power Analyser<br />

NEW<br />

Cat IV 600V<br />

Class A<br />

Power Analysis<br />

<br />

<br />

<br />

Data Logging<br />

<br />

<br />

<br />

IR5001 Temperature<br />

Humidity Logger<br />

Power Parameters Pty Ltd<br />

83 Northern Road, Heidelberg West, Vic 3081<br />

www.parameters.com.au power@parameters.com.au<br />

Freecall: 1800 623 350 Freefax: 1800 067 263<br />

32<br />

8870-20 Memory HiCorder


www.techrentals.com.au<br />

Electrical Power<br />

Power Analysers & Recorders<br />

cont’d.<br />

Hioki 3196 Power Quality Analyser<br />

with 4 x 1,000A CTs<br />

HIO,3196PQA-CT1000A (8730) AU<br />

High speed field unit, measuring transient and<br />

sub-cycle disturbances, total energy, tariffs and<br />

max demand. Four voltage (150~600V RMS),<br />

and 4 current (0 to 1kA), channels. Supplied with<br />

4 clamp-on CTs. Memory 512MB flash card. Colour display. Records V, A,<br />

pf, f(Hz), kVA, kVAr, kW, harmonics, and flicker. Supplied software provides<br />

graphs and summaries to PC. RS232 or LAN interface for PC communications.<br />

Hioki 3197 Power Quality Analyser<br />

with 3 x 500A CTs<br />

HIO,3197PQA (8731)<br />

AU<br />

Comprehensive portable PQA. Monitor for:<br />

inrush current, voltage swell, voltage dips, transient<br />

over-voltage and interruptions. Measure and record:<br />

power and power factor, active/reactive energy, demand, load changes (with<br />

graph display), voltage and current. Measures Impulsive voltage quality:<br />

transient over voltage (Impulse). RMS voltage quality: voltage swell, voltage<br />

dips, voltage interruption. Power quality: frequency, voltage, current, current<br />

peak, active/reactive/apparent power, power factor (displaced power factor).<br />

Three phase quality: voltage unbalance ratio, current unbalance ratio.<br />

Harmonic quality (up to 50th order) : harmonic voltage, harmonic current,<br />

harmonic power, harmonic voltage/current phase angle, total harmonic voltage<br />

distortion, total harmonic current distortion (THD-F, THD-R).<br />

Hioki 3332 Power HiTester Suitable for Standby Power Single Phase<br />

HIO,3332 POWERTESTER (8735)<br />

AU<br />

Suitable for measuring very low effective power, for stand -by mode of home<br />

equipment. Ultra high-sensitive measurement. Use to measure effective<br />

power of equipment in standby mode: Current 1mA with 0.1μA resolution.<br />

Wide Measurement range, up 5A direct input and auto range facilities are<br />

available. Suitable for single-phase/two wire power measurement. Voltage<br />

measuring ranges from 15V to 600V six ranges, Power 15mW to 30kW 90<br />

ranges. Integration range 0 to ± 999999MAh/MWh, integration time up to<br />

10,000 hours. RS232C interface. Other features includes measurement of<br />

inrush current during device start-up, measurement of standby power under<br />

1W, precise calculations of minute stand by power, when 150V/1mA range is<br />

selected, integration from ± 000.000mWh can be performed. Low numbers/<br />

units are automatically switched to a 6 digit display, allowing measurement in<br />

high resolution.<br />

LEM Topas 1000 Power Network<br />

Analyser<br />

LEM,TOPAS1000 (8736)<br />

AU<br />

Measures all relevant parameters in one measurement<br />

system. Inputs (isolated) voltage 4 channels, 200mV<br />

to 1kV, current 4 channels, supplied with 4 x 0 to 10A,<br />

10A to 100A AC clamp-on CTs and 4 x (unit powered) 0 to 3kA LEM-Flex current<br />

sensors. Can be configured for 8 voltage channels. Measuring functions RMS,<br />

V(U) voltage imbalance, positive, negative & zero phase sequence, phasor<br />

(vector) diagrams, amps (I)a, pf, kVA, kVAr, f(Hz), energy, on-line oscilloscope,<br />

power and multimeter, harmonics (by power/direction, magnitude & phase),<br />

inter-harmonics, THD, flicker, transients (100kHz to 10MHz), will capture<br />

events from 0.1μs in duration. Software configured manual or auto trigger<br />

levels, ethernet or serial interface, memory >540Mb/HDD.<br />

Power Analysers & Recorders<br />

cont’d.<br />

Metrix MX2040 AC/DC Clamp-on Meter<br />

MET,MX2040 (8745)<br />

AU<br />

Measures A, V, Hz, kW, kVA, kVAR, kWH, PF and resistance.<br />

Ranges 200A & 2kA, 600V & 1kV, 20kW, 200kW & 2MW &<br />

kWH. Scale length 3,000. 1 & 3ph operation. Motor rotation<br />

indication. Peak, min, max, average, RMS, and crest factor<br />

indication. Peak response time 1μs. Analogue output option<br />

fitted giving dynamic signals and calculated parameters<br />

(energy, etc). Jaw opening 55mm for 22 x 64 bars.<br />

Current Clamp Probes & Accessories<br />

See also Electrical Testers on page 26-27<br />

See also Power Analysers & Recorders on page 29-33<br />

CHK 3 Phase Converter for CTs 1A Input to 200mA Output<br />

CHK,CK1 (8751)<br />

AU<br />

Adaptor for CTs with 1A secondary outputs, this unit suits CHK,PM30/20.<br />

CHK 3 Phase Converter for CTs 5A Input to 200mA Output<br />

CHK,CK5 (8752)<br />

Adaptor for CTs with 5A secondary outputs, unit suits CHK,PM30/20.<br />

CHK CR100 Clamp-on CT<br />

CHK,CR100 (8753)<br />

AU/MY<br />

Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CR500 Clamp-on 500 CT<br />

CHK,CR500 (8754)<br />

AU<br />

Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CT1000L Large 1kA Primary Clamp-on CT<br />

CHK,CT1000L (8796)<br />

Large 123 x 35mm 1kA primary clamp-on CT for CHK,PM20/30.<br />

CHK CT3000L Large 3kA Primary Clamp-on CT<br />

CHK,CT3000L (8756)<br />

Large 123 x 35mm 3kA primary clamp-on CT for CHK,PM20/30.<br />

AU<br />

AU<br />

AU<br />

Dranetz Communications Adapter - Fibre<br />

to Ethernet with Node Link Software<br />

DRA-BMI,CAF-ETHERNET (8760)<br />

AU<br />

Communications Adapter. Fibre to<br />

ethernet with NodeLink Software and Moxa<br />

Networking Software for the DRA-BMI,PX5<br />

and DRA-BMI,PG4400.<br />

Dranetz AC/DC Current Clamp 3 to 1500A RMS<br />

DRA-BMI,PR1500 (8762)<br />

AU<br />

Max conductor size is 52mmØ. Current clamp<br />

is suitable for any of Dranetz-BMI models<br />

DRA-BMI,PG4400, DRA-BMI,PX5. Current<br />

clamp/probe is very useful for current<br />

measurement through CT current transformer. CT<br />

Ratio can be selected on the Dranetz-BMI abovementioned<br />

models.<br />

33


Electrical Power<br />

www.techrentals.com.au<br />

Current Clamp Probes &<br />

Accessories cont’d.<br />

Dranetz PR6035A/36 Flexible<br />

Current Clamp 60/600/6,000A<br />

DRA-BMI,PR6035A/36 (8763)<br />

AU<br />

Set of 3 flexible current clamps 60/600/6,000A<br />

RMS, max conductor size/length of clamp is 36”.<br />

Current clamps are suitable for any of Dranetz-<br />

BMI Models. DRA-BMI,PG4400/DRA-BMI,PX5. Current clamp/probe is very<br />

useful for current measurement through CT current transformer. CT Ratio can<br />

be selected on the Dranetz-BMI above-mentioned models.<br />

Dranetz TR2021 Current Clamp 1 to 30A 48Hz to 10kHz<br />

DRA-BMI,TR2021 (8764)<br />

AU<br />

Set of 3 current clamps 1A to 30A RMS, 48Hz to 10kHz. Max conductor<br />

size 12mmØ. Current clamps are suitable for DRA-BMI,PG4400,<br />

DRA-BMI,PX5 and DRA-BMI,PX5-400 models and are very useful for<br />

current management through CT current transformer. CT Ratio can be<br />

selected on the above-mentioned models.<br />

Current Clamp Probe 0 to 1A RMS<br />

DRA-BMI,TR2501 ( 8765)<br />

AU<br />

Set of 4 current clamp/probes, range 0 to 10A RMS. Max conductor size 12mm<br />

dia. Suitable for power quality analysers DRA-BMI,PG4400, DRA-BMI,PX5<br />

and DRA-BMI,PX5-400. For current measurement through CT current<br />

Transformer. CT Ratio can be selected on the above mentioned models.<br />

Dranetz TR2510 Current Clamp Probe 0 to 10A RMS<br />

DRA-BMI,TR2510 (8766)<br />

AU<br />

Set of 4 current clamp/probes, range 0 to 10A RMS. Max conductor size 12mmØ.<br />

Suitable for power quality analysers DRA-BMI,PG4400, DRA-BMI,PX5 and<br />

DRA-BMI,PX5-400. For current measurement through CT current Transformer.<br />

CT Ratio can be selected on the above mentioned models.<br />

Fluke 376 True-rms AC/DC Clamp Meter with iFlex<br />

FLU,376 (8770)<br />

AU/MY<br />

1,000A AC and DC current measurement with fixed<br />

jaw. 2500A AC current measurement with the 45cm<br />

iFlex flexible current probe. 1000V AC and DC voltage<br />

measurement. Voltage and current measurements are<br />

true rms. Includes ability to measure frequency, resistance<br />

and capacitance. Rated CAT IV 600V and CAT III 1000V.<br />

Fluke i1010 AC/DC Current Clamp 1,000A DC<br />

and 600A AC<br />

FLU,I1010AC/DC CLAMP (8771)<br />

AU<br />

Battery-powered Hall-effect probe measures 1A to<br />

1,000A. 1mV/Amp output guarantees easy reading<br />

on your meter. Take accurate current readings without<br />

breaking the circuit.<br />

Fluke i410 AC/DC Current Clamp 400A AC/DC<br />

FLU,I410 AC/DC CLAMP (8772)<br />

AU<br />

Battery-powered Hall-effect probe measures 1A to 400A. 1mV/Amp output<br />

guarantees easy reading on your meter. Take accurate current readings<br />

without breaking the circuit. Maximum conductor Ø 32mm. CAT III 600V<br />

safety rating.<br />

Hioki AC/DC Clamp on Meter with Analog Output 20/200A<br />

HIO,3284 (8780)<br />

AU<br />

Can also measure volts, ranges 30V, 300V, 600V AC/DC. Frequency ranges<br />

10Hz, 100Hz, 1,000Hz. Display LCD, counts max 2,500 current, 3,750<br />

voltage, 1,250 frequency. Output voltage 1V for 2,000 count on full scale for<br />

each current range, can select Rec rms output, response time about 250ms<br />

rise time, fall about 500ms. Select Mon for waveform output. 1V is produced<br />

for 1,000 count on full scale frequency range. Output not available for voltage<br />

measurements. Supplied with signal output cord, 4mm to BNC convertor,<br />

carry case and AC adaptor. Note: Can be powered with internal 9V battery or<br />

AC adaptor. (AC adaptor not supplied.)<br />

34<br />

Current Clamp Probes &<br />

Accessories cont’d.<br />

Hioki 3285 AC/DC Clamp-on Meter<br />

with Analog Output<br />

HIO,3285 (8781)<br />

AU<br />

Ranges 200A/2kA AC/DC. Measure volts, ranges 30V,<br />

300V & 600V AC/DC. Frequency ranges 10Hz, 100Hz<br />

& 1kHz. Display LCD, counts max 2,500 current, 3,750<br />

voltage and 1,250 frequency. Output voltage 1V for 2,000<br />

count fs for each current range, can select Rec RMS<br />

output, response time about 250ms rise time, fall about<br />

500ms. Waveform output. 1V is produced for 1,000 count<br />

on full scale frequency range. Output not available for<br />

voltage measurements. Supplied with signal output cord,<br />

4mm to BNC convertor, carry case and AC adaptor.<br />

Powered with internal 9V battery or AC adaptor. (AC<br />

adaptor not supplied) adaptor.<br />

Hioki 3290 Clamp-On AC/DC HiTester<br />

HIO,3290<br />

MY<br />

Current Measurement at DC and from 1Hz<br />

AC to 1,000Hz. Current Clamp Hioki 9693<br />

Clamp-on AC/DC sensor ranges: 20A, 200A &<br />

2,000A, jaw opening 55mm.<br />

Hioki 9660 Clamp-on 100A AC CT<br />

HIO,9660CT100A (8783)<br />

AU<br />

Rated primary current 100A AC. Amplitude accuracy: ±0.5% rdg. ±0.2%fs<br />

(at 45 to 66Hz). 66Hz-5kHz ±1% or less. Max circuit voltage 300V RMS/<br />

insulated wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.<br />

Hioki 9661 CCT-500A Clamp-On<br />

Sensors 500A, 500mVAC Output<br />

HIO,9661 CCT-500A (8784)<br />

AU<br />

500A rated, 500mVAC f.s. output,<br />

core jaw dia 46mmØ. Designed with<br />

a safety barrier to protect the user<br />

from being in direct contact with live<br />

conductors and completely meet all CE<br />

marking requirements. Basic specifications: Rated input current 500A AC,<br />

rated output current 0.5VAC, accuracy (at 45 to 66Hz), amplitude: ±0.5%<br />

rdg ±0.2% f.s. Full scale (f.s.) is the 3196 range value, phase: ±0.5° or less,<br />

frequency characteristics 66Hz to 5kHz (±1% or less from accuracy), max<br />

allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage<br />

600VAC RMS (insulated wire), core jaw Ø46mm, dimensions, mass 77mm W<br />

x 151mm H x 42mm D, 360g, cord length 3m.<br />

Hioki 9661-01 CCT-500A Clamp-on<br />

Sensors<br />

HIO,9661-01 CCT-500A (8784)<br />

AU<br />

500A rated, 500mVAC fs output, jaw 46mmØ.<br />

Rated input current 500A AC, rated output<br />

current 0.5VAC, accuracy (at 45 to 66Hz).<br />

Amplitude ±0.5%rdg, ±0.2%f.s., fs is the 3196<br />

range value, phase ±0.5° or less, frequency<br />

characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous<br />

550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire).<br />

Dimensions 77mm W x 151mm H x 42mm D, cord 3m. Suitable for Hioki<br />

models: 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS,<br />

8715-01, any data logger/scope which takes up to 1.7mVAC input.<br />

New items are being added to the inventory<br />

constantly, so if you do not see what you are<br />

looking for please call 1800 632 652.


www.techrentals.com.au<br />

Electrical Power<br />

Current Clamp Probes &<br />

Accessories cont’d.<br />

Hioki Flexible Clamp-on Sensors 10Hz to<br />

20kHz, 500/5,000A<br />

HIO,9667-FCT-5000A (8786)<br />

AU<br />

10Hz to 20kHz, 500/5,000A rated,<br />

500mV AC f.s. output, 254mm diameter<br />

maximum. Designed with a safety barrier to protect the user from being<br />

in direct contact with live conductors and completely meet all CE marking<br />

requirements. Basic specifications: Rated input current 500A AC, 5,000A<br />

AC, rated output current 0.5V AC, accuracy (at 45 to 66Hz). Amplitude:<br />

±2% rdg ±1.2mV, full scale (f.s.) is the 3196 range value, phase: ±1° or less,<br />

frequency characteristics 10Hz to 20kHz, maximum allowable input<br />

continuous 1,0000A rms (45 to 66Hz), maximum circuit voltage 1,000V AC rms<br />

(insulated wire), core jaw dia Ø254mm(10in). Dimensions: mass 254mmW x<br />

86mmH x 30mmD, 140g. Sensor length: 910 mm. Suitable for the following<br />

Hioki Models: HIO,3196PQA, HIO,3197PQA, HIO,3169-20CLAMPONPT,<br />

HIO,2331-20RPMS, HIO,2331-20RPMS, HIO,8715-01, any data logger/scope<br />

which takes up to 1.7mV AC input.<br />

Hioki 9669-CCT-1000A Clamp-on<br />

Sensors<br />

HIO,9669-CCT-1000A (8787)<br />

AU<br />

Jaw 55mmØ, 80mm x 20mm busbar.<br />

Rated input current 1,000A AC, rated output<br />

current 0.5VAC, accuracy (at 45 to<br />

66Hz) amplitude ±1% rdg, ±0.01% fs, fs is<br />

the 3196 range value, phase ±1° or less,<br />

frequency characteristics 66Hz to 5kHz (±1%), max. Allowable input continuous<br />

1,000A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated<br />

wire). Dimensions 99.5mm W x 188mm H x 42mm D, cord 3m. Suitable for<br />

Hioki models 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS,<br />

8715-01, any data logger/scope which takes up to 1.7mVAC input.<br />

Hioki 9670 Thermal Printer, Input RS232C,<br />

suitable for most of the Hioki Series<br />

HIO,9670 PRINTER (8788)<br />

AU<br />

Operates from a computer or the other host system.<br />

Battery operated. Prints 16 x 16 dots and 24 x 24 dots<br />

(as well as Japanese characters JIS Level I and II), and<br />

can print bar codes. Provides various settings such as<br />

enlarged-character printing. Graphics can be printed<br />

using bit images. Suitable for most of the Hioki Series.<br />

Hioki 9694 Clamp-on CT 5A<br />

HIO,9694CT5A (8789)<br />

AU<br />

Rated primary current 5A AC. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at 45<br />

to 66Hz), 66Hz to 5kHz ±1% or less. Max circuit voltage 300V RMS/insulated<br />

wire. Core jaw 15mmØ. Size mm: 46w × 21d × 135h, cord length 3m.<br />

LEM Current Probe 10A to 1A Suitable for LEM,TOPAS 1000 PQA<br />

LEM,CURRENT PROBE10A (8793)<br />

10A to 1A suitable for LEM Topas 1000 power quality analyser.<br />

LEM FLEXII 30, 300 & 3,000A Transducer<br />

LEM,LEM-FLEXII (8794)<br />

AU<br />

Flexible wrap-around AC current transducer. Length 600mm. Ranges 30A,<br />

300A & 3kA. Frequency response 1 to 20kHz. Accuracy 1%. Phase error<br />

0.5°. Output 3V RMS @ full scale. Requires 3 units for 3ph. Designed for<br />

multimeters and oscilloscopes (4mm banana plug or BNC connectors). Other<br />

instruments may be attached providing the correct adaptor/transducer and<br />

connection is available. Operates for 100h from 2 x 9V batteries.<br />

AU<br />

Current Clamp Probes &<br />

Accessories cont’d.<br />

Universal <strong>Tech</strong>nic P75.3C DC/AC Amp Clamp<br />

UNI,P75-3C (8795)<br />

AU<br />

Max current 7,500A DC & AC peak. Bandwidth 1kHz. Min range 1kA.<br />

Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size<br />

122 x 54mm or 100 x 64mm. Max cable size 83mm. Battery 9V, life 100h.<br />

Output sockets 4mm. DC current gives DC output, AC current gives AC<br />

output, 4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.<br />

Universal <strong>Tech</strong>nic Clamp-On AC/DC Current<br />

Probe 4000/7500A<br />

UNI,P75-3C HYBRID-DP (8796)<br />

AU<br />

Ranges 7,500A/1.5V & 4,000A/2V with hybrid<br />

power fitted for battery and external power supply,<br />

3V operation. Safety sockets 4mm. Clamp is<br />

suitable for use with any instrument with an input<br />

range of 2VAC or DC, and an input impedance<br />

greater than 10kΩ. e.g. voltmeter, chart recorders,<br />

oscilloscopes, and power quality analysers.<br />

Insulation Testers & Meggers to 20kV<br />

EA <strong>Tech</strong>nologies<br />

UltraTev Plus Partial<br />

Discharge Detector<br />

EAT,ULTRATEVPLUS (8410)<br />

AU<br />

Multi-function Partial Discharge (PD) Instrument. It<br />

measures accurate PD activity using the UltraTEV<br />

detector and an ultrasonic detector. It gives you an<br />

objective measure of the level of activity. Will display<br />

PD severity level. The kit includes the Ultradish for<br />

measurement of overhead assets.<br />

Fluke 1587 Insulation Multimeter<br />

FLU,1587<br />

MY<br />

Insutation: measurement range: 0.01M to 2GΩ. Test Voltages: 500V, 1,000V,<br />

50V, 100V, 250V, 500V, 1,000V Multimeter: Voltage 1mV to 1,000VAC/DC,<br />

current 0.01mA to 400mA AC/DC, resistance 0.1Ω to 50.0MΩ, capacitance<br />

1nF to 9999μF, frequency 0.01Hz to 99.99kHz.<br />

Fluke 1653 Electrical Installation Tester<br />

FLU,1653<br />

MY<br />

Tester verify the safety of electrical installations, according to IEC 60364, HD<br />

384 standards. Functions available: voltage and frequency measurement,<br />

insulation resistance testing, continuity testing, loop impedance, RCD tripping<br />

time, RCD tripping current, Earth resistance and Phase sequence.<br />

Hioki 3455 High Voltage<br />

Insulation Tester<br />

HIO,3455HVIT-5kV (8411)<br />

AU/MY<br />

PI and DAR function to check insulation quality and<br />

step voltage test to detect for signs of deterioration.<br />

Generates test voltages from 250V to 5kV in commonly<br />

used presets of 250V, 500V, 1kV, 2.5kV & 5kV, or set<br />

to desired level by increments or decrements of 25V<br />

or 100V. Insulation diagnoses for automatic calculation and indication of PI<br />

(Polarisation index) and DAR (Dielectric absorption ratio), step voltage testing<br />

and temperature correction. Large memory stores up to 100 manual records<br />

and a logging function for 10 data (360 times). Stored data with date and time<br />

may be displayed on the LCD or down-loaded.<br />

35


Electrical Power<br />

www.techrentals.com.au<br />

Insulation Testers & Meggers to 20kV<br />

cont’d.<br />

Kikusui TOS-5101 10kV AC/<br />

DC Hipot Tester<br />

KIK,TOS-5101 (8426)<br />

AU<br />

Hipot testing up to 10kV in either DC or AC.<br />

Digital voltmeter and ammeter, digital timer. Window comparator for more<br />

reliable pass/fail judgement. Automatic discharge of DUT in DC test mode.<br />

Equipped with Key Lock and Interlock functions for greater safety.<br />

Megger MIT1020 Diagnostic<br />

10kV Insulation Resistance<br />

Tester<br />

MEG,MIT1020-10KV DIT (8423)<br />

AU<br />

Backlit display, variable test voltage from 50V to<br />

10,000V, Automatic IR, PI, DAR, SV and DD tests,<br />

measures to 35T, RS232 and USB download of results.<br />

IEEE 43-2000 recommends the use of 10kV for motor<br />

windings rated above 12kV. Protection rating of IP54.<br />

Mains or battery powered.<br />

Megger S1-1052 High Current Insulation<br />

Resistance Tester 10kV<br />

MEG,S1-1052 10KV-DIT (8424)<br />

AU<br />

High output current 5mA for fast charging of<br />

capacitive loads. Testing up to 10kV, mains or<br />

battery powered, digital/analogue backlit display,<br />

variable test voltage from 50V to 10,000V, automatic IR, PI, DAR, SV and DD<br />

tests. Measures to 35TΩ. RS232 and USB download of results.<br />

Megger S1-552 High Current<br />

Insulation Resistance Tester 5kV<br />

MEG,S1-552 5KVDIT (8425)<br />

AU<br />

High output current 5mA for fast charging of<br />

capacitive loads. Testing up to 5kV, mains or battery<br />

powered, digital/analogue backlit display, variable<br />

test voltage from 50 to 5,000V, automatic IR, PI, DAR, SV and DD tests.<br />

Measures to 15TΩ. RS232 and USB download of results.<br />

Oil, Hipot & VFL Testers above 20kV<br />

Hipotronics 880PL-10MA-B<br />

80kV DC Hipot Tester<br />

HIP,880PL (8491)<br />

AU<br />

Compact, portable unit (41kg) for DC field testing of<br />

cables, terminations, motors, generators and other<br />

electrical apparatus. 80kV 10mA output capability with multirange voltmeter<br />

and ammeter. For operator safety the power supply and test object are<br />

automatically grounded when high voltage is turned off, and there is no<br />

exposed high voltage. Guard circuit for accurate leakage current<br />

measurement. Includes overload relay and surge limiting resistors in HV<br />

output.<br />

High Voltage Inc PFT503, 50kV AC Test Set<br />

HIV,PFT503 (8453)<br />

AU<br />

Single, portable (34kg) unit suited for testing overhead apparatus, vacuum<br />

bottles and interrupters, switch gear, bus duct, motorized vacuum switches,<br />

reclosers, bushings, fuses and arrestors, linemans safety products, small<br />

transformers, electrical components and motors. This 3kVA model features<br />

capacitive load compensation enabling full load testing with a power draw of<br />

1.5kVA while operating from a conventional line input. 60mA output current<br />

capability.<br />

Oil, Hipot & VFL Testers above 20kV<br />

cont’d.<br />

High Voltage Inc Very Low Frequency<br />

(VLF) 6022 60kV Hi-pot Test Set<br />

HIV,VLF6022 (8454)<br />

AU<br />

For field testing of AC high/medium voltage<br />

cables, bushings, and insulators. Input<br />

230V, 50Hz, 6A peak, 2.5A average.<br />

Output sinusoidal, 0 to 60kV AC peak,<br />

frequency 0.1, 0.05 & 0.02Hz.<br />

Duty continuous. Test load capacitance 1.1μF (approx 3kms of cable<br />

at 0.1Hz), 2.2μF (approx 9kms of cable at 0.05Hz) & 5.5μF (approx<br />

13kms of cable at 0.02Hz). Display 0 to 60 peak kV.<br />

Interconnect cable length 3m, control unit to HV transformer. RG8/U output<br />

cable length 3m. Shorting stick braid 6m. HV tank and control units shipped in<br />

travel cases weighing 70 & 40kg respectively.<br />

High Voltage Inc VLF-90CM 90kV Test Set<br />

HIV,VLF90 (8455)<br />

AU<br />

Very low frequency (VLF-90CM) AC hipot test set<br />

with 90kVAC peak output, is suitable for testing<br />

cables up to 50kV. High load capacity enables it<br />

to test up to approx 7 miles of cable, depending<br />

on type. Includes a charging current and load<br />

capacitance meter, test dwell timer, and polarity<br />

indicating lights. Output voltage and frequency,<br />

sinusoidal 0 to 90kVAC peak & selectable, 0.1, 0.05, 0.02Hz. Test frequency<br />

and rated loads with approximate cable lengths are: -0.1Hz/0.55μF 1,673m<br />

of cable, 0.05Hz/1.1μF 3,353m of cable, 0.02Hz/2.2μF 6,706m of cable.<br />

Kilovoltmeter scaled 0 to 100kVAC peak, ammeter scaled 0 to 100mA AC<br />

and 0-6μF load capacitance. Weight of the unit 167kgs. HV Cable output is<br />

6m flexible, shielded x-ray with alligator clamp, inter connect cable length 3m,<br />

shorting stick 6m lead with clip.<br />

HV Diagnostics HVA TD60 Portable TanDelta<br />

Measurement System<br />

HVD,HVA TD60 (8460)<br />

AU<br />

Optional Accessory for HVD,HVA60-DC/VLF and HVD,HVA90_<br />

DC-VLF. Tan Delta or Power Factor tester used to determine<br />

the power factor of cables, transformers, capacitors, rotating<br />

machines and other switchgear. This test allows the detection of<br />

insulation defects before they fail inservice.<br />

HV Diagnostics HVA30 30kV-15mA<br />

DC/VLF High Voltage Insulation<br />

DielectricsTest Set<br />

HVD,HVA30-DC/VLF (8461)<br />

AU/MY<br />

VLF and DC test capabilities combined in one unit<br />

(20kg). Suitable for testing cables (XLPE, PE, EPR,<br />

PILC etc), capacitors, switchgear, transformers,<br />

machines (IEEE 433), insulators and bushings. VLF<br />

(0.1Hz to 0.02Hz), DC (+/-), cable fault conditioning<br />

(burning) and sheath/jacket testing modes all included. Fully automatic or<br />

manual cable test sequences complying with International Standards/Guides<br />

such as IEEE 400.2, VDE 0276 and CENELEC. True symmetrical sinusoidal,<br />

load independent, output waveform across the full load range. Real-time<br />

display of actual output wave form. Easy to use, ergonomic, menu guided,<br />

large backlit user interface. Large output load capability (up to 5uF). Automatic<br />

and integrated load capacitance measurement with optimum frequency<br />

selection. Storage of test results for later retrieval or download to a PC/Laptop.<br />

36


www.techrentals.com.au<br />

Electrical Power<br />

Oil, Hipot & VFL Testers above 20kV<br />

cont’d.<br />

HV Diagnostics HVA60 60kV-50mA<br />

DC/VLF High Voltage<br />

Insulation Dielectrics Test Set<br />

HVD,HVA60-DC/VLF (8462)<br />

AU<br />

VLF and DC test capabilities combined in one unit<br />

(60 kg). Suitable for testing cables (XLPE, PE,<br />

EPR, PILC etc), capacitors, switchgear, transformers,<br />

machines (IEEE 433), insulators and bushings.<br />

VLF (0.1Hz to 0.02Hz), DC (+/-), cable fault conditioning (burning) and sheath/<br />

jacket testing modes all included. Fully automatic or manual cable test<br />

sequences complying with International Standards/Guides such as IEEE<br />

400.2, VDE 0276 and CENELEC. True symmetrical sinusoidal, load<br />

independent, output waveform across the full load range. Real-time display<br />

of actual output wave form. Easy to use, ergonomic, menu guided, large<br />

backlit user interface. Large output load capability (up to 5uF). Automatic and<br />

integrated load capacitance measurement with optimum frequency selection.<br />

Storage of test results for later retrieval or download to a PC/Laptop. Optional<br />

Accessories: HVD,HVA TD60<br />

HV Diagnostics HVA90 90kV<br />

VLF/DC Test Set<br />

HVD,HVA90_DC-VLF (8463)<br />

AU<br />

VLF and DC test capabilities combined in one<br />

unit (127 kg). Suitable for testing cables (XLPE,<br />

PE, EPR, PILC etc), capacitors, switchgear,<br />

transformers, machines (IEEE 433), insulators and<br />

bushings. VLF (0.1Hz to 0.01Hz), DC (+/-), cable<br />

fault conditioning (burning) and sheath/jacket testing modes all included.<br />

Fully automatic or manual cable test sequences complying with International<br />

Standards/Guides such as IEEE 400.2, VDE 0276, CENELEC HD620 S1,<br />

NEN 3620, SANS 10198 and IEC 60060-3. True symmetrical sinusoidal, load<br />

independent, output waveform across the full load range. Real-time display of<br />

actual output wave form. Easy to use, ergonomic, menu guided, large backlit<br />

user interface. Large output load capability (up to 10uF). Automatic and<br />

integrated load capacitance measurement with optimum frequency selection.<br />

Storage of test results for later retrieval or download to a PC/Laptop. Optional<br />

Accessories: HVD,HVA TD60<br />

Baur DAP75 Insulating Oil Tester<br />

BAU,DPA75 (8451)<br />

AU<br />

Fully automatic insulation oil tester. Output voltage 0 to 75kV RMS.<br />

Selectable programmes to international standards. Integral printer. RS232<br />

interface. One transit case on wheels. Total weight is 35kgs.<br />

Megger OTS80PB Transformer Oil Tester<br />

Insulation Dielectrics Test Set<br />

MEG,OTS80PB (8450)<br />

AU<br />

Test voltage 80kV max at 61.8Hz. Fully automatic<br />

operation. Rechargeable batteries. RS232C<br />

interface.<br />

Phenix BK130 130kVAC Hipot Aerial Lift Test Set<br />

PHE,BK130 (8480)<br />

AU<br />

Tests elevating boom as well as the work platform and linings<br />

to ANSI A92.2 draft standard. Can also he used in many other<br />

Hipot applications that require the sort of voltage and current<br />

this instrument is capable of. Can supply 0 to 130kVAC @<br />

50mA and 0 to 35kVAC at 171mA. The whole system is built<br />

into a trolley cart for ease of use. Measurement accuracy 1%<br />

FS for 10 to 100% of range.<br />

Power Transformer Testers<br />

Biddle 550005 Turns Ratio Test Set<br />

BID,550005 (4601)<br />

AU<br />

Single phase (can be used on 3ph individual phase windings). Turns ratio<br />

0.001 to 129.999. Exciting current 0 to 1A. Accuracy 0.1%. Hand cranked<br />

operation.<br />

Megger 3Ph Transformer Tester<br />

MEG,TTR320-47 (4610)<br />

AU<br />

3 Phase transformer turns ratio test set.<br />

Automatic operation, graphical user interface.<br />

Stores up to 100,000 data sets.<br />

Megger MT0330 Automated<br />

Six Winding Transformer<br />

Ohmmeter<br />

MEG,MT0330 (4611)<br />

AU<br />

Delivers full eight-terminal/six-winding resistance<br />

measurement capability. Designed to save time<br />

by testing all six windings without having to disconnect and reconnect leads.<br />

Also, the simultaneous winding magnetization method gives fast and reliable<br />

measurements even on large transformers with delta configuration on the low<br />

voltage side. The leads are interchangeable with the Megger TTR320 threephase<br />

turns ratio instrument which eliminates additional connecting time for<br />

turns ratio measurements. Includes an on-board computer with QWERTY<br />

keyboard, USB and ethernet.<br />

Omicron CPC 100 Multi-functional<br />

Primary Test System<br />

OMI,CPC100PTS (4620)<br />

AU<br />

Portable (29kg) primary test system suited for testing<br />

of current transformers, voltage transformers, power<br />

transformers, power lines, HV cables, grounding systems,<br />

switchgear and circuit breakers, protection relays and<br />

more. Tests to 800A (extended to 2000A with CP CB2)<br />

over frequency range 15Hz to 400Hz, or to 400A DC. Panasonic Toughbook<br />

included, preloaded with CPC 100 Toolset. Optional accessories: OMI,CPCU1<br />

OMI,CPSB1 OMI,CP-TD1 OMI,CPCB2<br />

Omicron CP CU1<br />

Multi-Purpose Coupling<br />

Unit for CPC 100<br />

OMI,CPCU1 (4623)<br />

AU<br />

Combined with the CPC 100, the CP CU1 is<br />

a measurement system for line impedances & k-factors of overhead lines or<br />

power cables, mutual coupling of parallel lines, ground impedances of large<br />

substations and coupling of power lines into signal cables. This test system<br />

overcomes the problem of power system frequency interference that has<br />

previously made it necessary to use extremely large, high-power equipment<br />

to carry out these measurements.<br />

Omicron CPSB1 Switch Box<br />

OMI,CPSB1 (4621)<br />

AU<br />

Switch Box to allow fully automated 3 phase transformer<br />

testing, accessory for the CPC100.<br />

Omicron CP TD1 Capacitance and Tan Delta<br />

Add-on<br />

OMI,CP-TD1 (4622)<br />

AU<br />

Combined with the CPC 100, the CP TD1 measures the<br />

capacitance and dissipation factor (power factor) with<br />

laboratory precision. This allows the insulation condition of<br />

transformers, generators and other parts of high-voltage<br />

systems to be tested according to IEEE 62 (C57.152),<br />

IEC 60076-1 and -3, as well as the CIGRE “Guide for<br />

Transformer Maintenance”. As recommended in the<br />

CIGRE Guide, testing is performed at variable frequencies to better diagnose<br />

signs of ageing in insulation. The portable test system (max. 29 kg per<br />

component) can also generate output voltages of up to 12kV. Trolley included.<br />

37


Electrical Power<br />

www.techrentals.com.au<br />

Power Transformer Testers cont’d.<br />

Omicron FRA Frequency Response Analyser<br />

OMI,FRA (4630)<br />

AU<br />

Uses swept frequency response analysis to detect<br />

mechanical and electrical changes of the core and<br />

winding assembly of power transformers. By finding<br />

winding or core defects after faults, mechanical<br />

shocks or transportation, it offers a valuable<br />

opportunity to improve the reliability of transformers,<br />

to reduce maintenance costs and to avoid expensive, unexpected outages.<br />

Panasonic Toughbook included, preloaded with the FRAnalyzer software.<br />

Current Injectors<br />

Omicron CT Analyser Current<br />

Transformer Analyser<br />

OMI,CTANALYZER (4631)<br />

AU<br />

Portable (8 kg) and automated unit for testing<br />

protection and metering CTs onsite. CTs can be<br />

verified up to the 0.1 accuracy class. The included<br />

switchbox allows automated testing of CTs with up to<br />

six taps. Remanence can be measured and cores can<br />

be demagnetised.<br />

Multi-Amp MS-2 High Current Test Set<br />

MUL,MS-2 (1261)<br />

AU<br />

Designed to test overload relays, circuit<br />

breakers and earth fault trip devices.<br />

Input 240V 50/60Hz. Output continuously<br />

adjustable in 4 ranges 120V/5A, 24V/25A,<br />

6V/120A & 3V/240A. Short term over<br />

current of several times the rated current ranges is possible. Digital current<br />

meter has read and hold facilities for short duration currents. Digital timer<br />

measures elapsed time between energisation and the test device operating.<br />

Programma Magnus 2.2kV Step Up<br />

Transformer for Testing CT’s<br />

PRO,MAGNUS-2.2kV (1262)<br />

AU<br />

Use in high-voltage substations and industrial<br />

environments. Protected with thermal<br />

cut-outs, mains voltage 230Vac ±10%, 50 to<br />

60Hz, power consumption is 2.3kVA. Used<br />

for preparing excitation curves for instrument<br />

transformers and for demagnetizing current transformer cones. Safety key lock<br />

(block unauthorised use).<br />

SMC PTE-100-C<br />

Secondary Current Test Set<br />

SMC,PTE-100-C (1263)<br />

AU<br />

AC current and voltage outputs in 4 ranges<br />

200V/5A, 40V/25A, 20V/50A & 10V/100A.<br />

Additional outputs AC voltage 0 to 220V at 1A (4A<br />

1min), DC voltage 0 to 350V at 0.7A (2.8A 1min),<br />

DC voltage 0 to 250V at 0.25A, fixed 110V AC at<br />

0.3A. Timer 1ms to 99,999s. Additional functions include measurement of the<br />

phase angle between the voltage and the current output tap selected, and the<br />

measurement of the impedance of the load connected in the current output taps.<br />

T&R 200A-3PH/ED Current injection tester<br />

T&R,200A3PHEDIT (1264)<br />

AU<br />

0 to 200A/phase output capacity. Power supply 4 wire<br />

5A/phase 3ph 240/415V. Typically 10A 5 pin 3 phase<br />

socket outlet HPM.<br />

Current Injectors cont’d.<br />

T&R CIT/LU2000 Primary Current Injection<br />

Test Set<br />

T&R,CIT (1265)<br />

AU<br />

Comprises control unit and 2kA loading unit<br />

(LU). Control unit includes timer, current and<br />

voltage meters, and variable output transformer.<br />

External loading unit output 0 to 2kA, duty 5min<br />

on 15min off at 6VAC, continuous 0 to 1kA at<br />

3VAC. Two units weight 35 & 45kg plus 2 quad<br />

70mm2 cable sets each 3m long. Control unit<br />

connects to LU with supplied interface cable.<br />

T&R PCU1-SP with CT Ratio/<br />

Polarity and NLU5000A Loading Unit<br />

T&R,PCU1-SP NLU5000A (1266)<br />

AU<br />

Medium powered primary current injection system.<br />

Features 5kA maximum output current (higher overload<br />

current for 2s). Multi-function digital timing system.<br />

Digital true RMS memory ammeter. Solid state switching.<br />

2,000A and 5,000A load units. Three range outputs on<br />

loading units. Rugged, compact design. Secondary injection up to 100A.<br />

Direct reading CT ratio and polarity. May be configured to either give a<br />

maximum current of 5,000A on the 2.3V range, 2,500A on the 4.6V range or<br />

1,250A on the 9.2V range.<br />

Protection Relay Testing Systems<br />

Megger Protective Relay Test System<br />

IEC 61850<br />

MEG,MPRT8430-BAS-3CH (4650)<br />

AU<br />

Performs routine testing of protective relays.<br />

The standard configuration delivers three<br />

voltages and three currents, or six currents.<br />

Specifications: AC current output: 0 to 90A, AC voltage output: 0 to 600V,<br />

DC voltage output: 0 to 600V, frequency range: 0.001 to 9999.999Hz. The<br />

TouchView Interface Controller features a full color, touch screen interface.<br />

Includes AVTS software.<br />

Omicron CMA 156 Six Phase Current Amplifier (6 x 25A)<br />

OMI,CMA156-6PCA (4655)<br />

AU<br />

Can be used in combination with any CMC test set. The outputs<br />

are galvanically separated from the inputs as well as from ground and are used<br />

independently or in addition to those of the CMC test sets. The six independent<br />

current channels are arranged in two isolated groups (A, B). The outputs can<br />

be connected in parallel or in series. The connection to a CMC test set is made<br />

by a control cable at the back of the units. Used for tests requiring more current<br />

channels than provided by the CMC test sets.<br />

Omicron CMC256-6 Universal Relay Test Set<br />

OMI,CMC256-6 (4660)<br />

AU<br />

Protection relay test set and universal calibrator (energy<br />

meters, measuring transducers, power quality measurement devices, phasor<br />

measurement units etc) with six current sources (6 x 12.5A, 3 x 25A or 1 x<br />

75A), four voltage outputs (4 x 300V or 1 x 600V), 4 x binary outputs, 10 x<br />

multifunctional binary inputs (dry/wet) and Generator Combination Cable for<br />

wiring convenience. The six current and four voltage output channels are<br />

continuously and independently adjustable in amplitude, phase and frequency.<br />

All outputs overload and short-circuit proof. LLO-2 option not included.<br />

Panasonic Toughbook included, preloaded with Test Universe software<br />

(Universal). Optional accessories: OMI,CMA156-6PCA OMI,CMGPS<br />

38


www.techrentals.com.au<br />

Electrical Power<br />

Protection Relay Testing Systems<br />

cont’d.<br />

Omicron CMC<br />

256plus Universal<br />

Relay Test Set<br />

OMI,CMC256PLUS (4661)<br />

AU<br />

Protection relay test set and universal<br />

calibrator (energy meters of class 0.2, measuring transducers, power quality<br />

measurement devices, phasor measurement units etc) with six current sources<br />

(6 x 12.5A, 3 x 25A or 1 x 75A), four voltage outputs (4 x 300V or 1 x 600V),<br />

4 x binary outputs, 10 x multifunctional binary inputs (dry/wet) and Generator<br />

Combination Cable for wiring convenience. The six current and four voltage<br />

output channels are continuously and independently adjustable in amplitude,<br />

phase and frequency. All outputs overload and short-circuit proof. LLO-2 option<br />

not included. Panasonic Toughbook included, preloaded with Test Universe<br />

software (Universal). Optional accessories: OMI,CMA156-6PCA OMI,CMGPS.<br />

Omicron CMC 356 Advanced<br />

Protection Relay Test Set<br />

OMI,CMC356 (4656)<br />

AU<br />

Protection relay test set with six current<br />

sources (6 x 32A/430VA, 3 x 64A/860VA or 1 x<br />

128A/1000VA), four voltage outputs (4 x 300V or 1 x 600V), 4 x binary outputs,<br />

10 x multifunctional binary inputs (dry/wet) and Generator Combination Cable<br />

for wiring convenience. The six current and four voltage output channels are<br />

continuously and independently adjustable in amplitude, phase and frequency.<br />

All outputs overload and short-circuit proof. Panasonic Toughbook included,<br />

preloaded with Test Universe software (Advanced Protection + Transducer).<br />

Optional accessories: OMI,CMA156-6PCA, OMI,C-PROBE1 OMI,CMGPS.<br />

Omicron CMC 356<br />

Advanced Protection<br />

Relay Test Set +61850<br />

OMI,CMC356_61850 (4656)<br />

AU<br />

Protection relay test set with six current sources<br />

(6 x 32A/430VA, 3 x 64A/860VA or 1 x 128A/1000VA), four voltage outputs (4<br />

x 300V or 1 x 600V), 4 x binary outputs, 10 x multifunctional binary inputs (dry/<br />

wet) and Generator Combination Cable for wiring convenience. The six current<br />

and four voltage output channels are continuously and independently adjustable<br />

in amplitude, phase and frequency. All outputs overload and short-circuit proof.<br />

Includes IEC61850 software package (GOOSE, Sampled Values, IEDScout,<br />

SVScout). ELT-1 and LLO-2 options not included. Panasonic Toughbook<br />

included, preloaded with Test Universe software (Advanced Protection +<br />

Transducer) and IEC61850 package. Optional accessories: OMI,CMA156-<br />

6PCA, OMI,C-PROBE1 OMI,CMGPS.<br />

Omicron CMGPS Syncronisation Control Unit<br />

OMI,CMGPS (4662)<br />

AU<br />

Accessory for the Omicron CMC etc. A single GPS unit, if used to sych relay<br />

tests when performing end-to-end tests of line protection systems two are<br />

required. The unit provides a start signal pulse based on the GPS clock time<br />

base. Software is both integrated in the testing modules (State Sequencer)<br />

and can also be used as a stand-alone application.<br />

Omicron C-Probe-1 Clamp-on CT AC/DC<br />

OMI,C-PROBE1 (4664)<br />

AU<br />

Optional accessory for OMI,CMC356 and OMI,CMC356_61850. An active AC<br />

and DC current probe with voltage output. It is the recommended accessory<br />

for measuring currents with the CMC 356. It has 10A and 80A measuring<br />

ranges, frequency range DC to 10kHz. Accuracy error < 2% for currents up<br />

to 40A and frequencies up to 1kHz. Phase error < 0.5O @ 50/60Hz. Length<br />

230mm. Output: 0-10A range 100mV/A, 0-80A range 10mV/A.<br />

Protection Relay Testing Systems<br />

cont’d.<br />

Programma EGIL Circuit Breaker Analyser<br />

PRO,EGIL-CB ANALYZER (4670)<br />

AU<br />

One main contact per phase. Three time channels are<br />

connected together on one side. Events at parallel<br />

contacts equipped with pre-insertion resistors<br />

are recorded and displayed simultaneously.<br />

Two separate time channels for measurement of auxiliary contacts. On-site<br />

hookup comes with ready-made multi-cable sets for both main and auxiliary<br />

contacts. Coil currents are measured automatically, presented together with<br />

other readings immediately after testing on the display window or via the builtin<br />

printer. A built-in sequencer (program unit) sets the instrument automatically<br />

for the next sequential breaker operation. Intended primarily for measuring<br />

travel (motion). Can be equipped with an optional serial interface (RS232C) for<br />

communication with a PC and the CABA Win Breaker Analysis Software.<br />

Programma Sverker 760 Relay Test Set<br />

PRO,SVERKER760 (4672)<br />

AU<br />

Relay test set for 1ph protective relay equipment. Three phase relays<br />

can be tested 1 phase at a time or by synchronising more than one unit.<br />

Current ranges to 100A with full load current to 250A. AC outputs to 250V &<br />

DC outputs to 300V. In-built capacitor and resistors for current output phase<br />

shifting (3,600). In-built timer, ammeter, and voltmeter. Measures phase angle,<br />

PF, and impedance.RS232 communications and control interface.<br />

T&R DVS3-HP Static Relay<br />

Test System<br />

T&R,DVS3-HP (4675)<br />

AU<br />

Test system for testing voltage and frequency<br />

protection relays and transducers. Tests<br />

Automatic Voltage Regulating (AVR) relays with line drop compensation,<br />

under and over voltage relays, directional over-current relays, df/dt (ROCOF)<br />

relays, vector surge (step change of phase) relays and check synchronising<br />

relay. Generates a 3ph voltage output from a 1ph supply, and may be used in<br />

conjunction with a current source to test directional protection. Requires 1ph<br />

50/60Hz supply of 115V or 230V (±15%). We only supply the DVS-T260 VT<br />

box (Ratio 1:2) which has a maximum output voltage of 266V for a maximum<br />

load of 10VA per phase. Accuracy, Class 2 (±0.2% for 2.5 to 10VA load).<br />

AC Sources/Inverters/Generators<br />

Chroma 61501 Programmable AC Power Source<br />

CHR,61501 PAC-PS (8201)<br />

AU<br />

Power: 500VA. Voltage: 0-150V/0 to 300V/AUTO. Compact size<br />

and weight attributable to advance PWM technology. AC, DC, AC+DC output<br />

mode. Programmable output impedance for IEC 61000-3-3. IEC 61000-4-11<br />

voltage dips and variation simulation. Harmonics, inter-harmonics waveform<br />

synthesizer for IEC 61000-4-13 testing. Power line disturbance simulation<br />

capability. Programmable voltage, current limit. Comprehensive measurement<br />

capability, including current harmonics. High output current crest factor, ideal<br />

for inrush current testing. Turn on, turn off phase angle control. TTL signal<br />

which indicates output transient. Software for IEC regulation test. Analog<br />

programmable interface. Optional GPIB and RS232 interface.<br />

Elgar 501 AC Power Source<br />

ELG,501 (8202)<br />

AU<br />

AC power amplifier. Operates from 240V 1ph AC. Output ranges on tapped<br />

transformer 0 to 65, 0 to 130, 0 to 260VAC. Output power 500VA. Amplifier<br />

output rated over 45Hz to 5kHz. Two units may be connected for 1kVA output.<br />

39


Electrical Power<br />

www.techrentals.com.au<br />

Power Transformers<br />

Tortech 240-110 2000 VA Transformer<br />

TOR,110-2000 (8226)<br />

Step-down transformer. 240 to 110 VAC. 2,000 VA.<br />

Variac 6500-3 3ph 6.5kVA Transformer<br />

VAR,6500-3 (8228)<br />

AU<br />

Variac 3ph 6.5kVA. 0 to 470VAC output for 415VAC input, max current 8A/ph.<br />

Dimmer Dot Variable AC Voltage Auto Transformer 3 Phase 23-28A<br />

VAR,D-283-OB (8229)<br />

AU<br />

Manual operated air cooled; Input 400/415V, 50Hz. Output 0 to 415/470V. 23<br />

to 28A. Total Weight 95kgs..<br />

Power Line Conditioners/UPS<br />

Socomec Sicon ENT-TW10 1kVA UPS On-Line Double Conversion<br />

SOC,ENT-TW10 (8251)<br />

AU<br />

Suitable for mainly Business Server, Internet/Intranet Server, Critical<br />

Applications, Domestic and Industrial Automation, Networking and ISP/ASP<br />

Application etc. On-line double conversion technology, high stability of output<br />

voltage and frequency, high input power factor, automatic battery test, optional<br />

battery pack expansion, minimal desktop space and easy to install, RS232<br />

and USB communication interface, high efficiency, automatic by-pass, 4<br />

output sockets and slot for insertion of SNMP/WEB Manager or relay card.<br />

AU<br />

Power Line Conditioners/UPS cont’d.<br />

Upsonic Power Conditioner 3000VA<br />

UPC,3000 (8252)<br />

AU<br />

3kVA Power Conditioner single phase with 230V/15A power cord and output<br />

leads with 230V/15A socket. High energy surge absorbers, LC filter, EMI filter.<br />

Fast response time 4ms per step, precise voltage regulation. Flexibility for<br />

any loads, like pure resistive load/capacitive load/inductive load. Automatic<br />

electronic bypass protection, overload protection, over range protection. Wide<br />

input voltage range.<br />

Battery Management Systems<br />

Hioki Battery HiTester<br />

HIO,3551BATTERYTEST (8275)<br />

AU<br />

Takes on-the-spot measurements of the<br />

internal resistance, voltage and temperature of<br />

lead-acid batteries, principally for UPS and similar<br />

applications, without needing to shut off the battery. Instantaneous results, on<br />

a three-rank scale of Pass, Warning, or Fail, using a composite decision based<br />

on the internal resistance and the voltage. Resolution of 1μΩ, necessary<br />

for high capacity batteries (of at least 500Ah). Includes Hioki 9460 clip type<br />

temperature leads.<br />

Megger Torkel 840 Battery Load Unit<br />

PRO,TORKEL-840 (8276)<br />

AU<br />

Portable (22 kg, 38 kg with accessories and transport case)<br />

battery discharge load unit. Works with 12V to 250V battery systems and<br />

can discharge at up to 110A (15kW maximum power). Can be programmed<br />

for constant current, constant power, constant resistance or user defined load<br />

profiles. The included DC current clamp allows on-load testing. Tests can be<br />

PC controlled and results reviewed using the included TORKEL Win software.<br />

The load current can be extended with the optional accessory PRO,TXL870<br />

extra load unit.<br />

HAVE YOU EVER EXPERIENCED TIMES WHEN MERELY IDENTIFYING A PROBLEM<br />

BECAME AN ISSUE, MUCH LESS FINDING A SOLUTION?<br />

These times can be extremely frustrating and time consuming. This is when the combination of both the depth of<br />

experience and diverse talent range of our <strong>Tech</strong><strong>Rentals</strong> team come to the forefront.<br />

GSM Messaging of Alarm Status and its Application to Environmental and Industrial Monitoring<br />

There are a number of industrial and environmental applications that can be enhanced and simplified with the use<br />

of SMS communication for routine and abnormal status advice.<br />

A recent application was in the monitoring of building site dust levels. The customer needed to know when dust<br />

levels were exceeding acceptable levels so as to schedule damping runs to reduce the dust. The solution was a<br />

TSI Dusttraker 8530 in a portable enclosure when defined dust levels were exceeded.<br />

This contact closure consequently triggered an ETM9900 module which would transmit an SMS message to<br />

the required mobile phone. A simple effective solution with significant cost savings and delivering a demonstrated<br />

commitment to environmental protection.<br />

Vehicle fleet efficiency management<br />

While vehicle location is often used in efficiency management knowing the time spent idle may be useful,<br />

particularly with vehicles that are operating continuously. Mine site vehicles would be one example where it<br />

may be possible to change the route and other operational details to reduce idle time.<br />

We do much more than rent equipment. <strong>Tech</strong><strong>Rentals</strong> - Your <strong>Tech</strong>nology Solutions Partner<br />

40


www.techrentals.com.au<br />

SETUP AND DOWNLOAD<br />

Save your time and reduce your costs by using our data management services. Learning<br />

to operate unfamiliar equipment costs you time and can lead to fundamental errors<br />

in data capture processing. There is a better solution - our setup and download service.<br />

Our technical staff are equipped and trained to deliver you the downloaded data in a range of<br />

suitable output formats including USB drive, CD-ROM, printout, chart and DVD according to your<br />

need and the product’s functionality.<br />

When you nominate your output preferences and appropriate technical information, the rest is taken care of.<br />

The completed fi les or printouts will be forwarded to you quickly or may be collected at an arranged time.<br />

The equipment marked with ‘S’ symbol is available to rent with this service. Fees vary depending on the<br />

complexity of operation and the level of detail involved.<br />

Data management services are available for many products. Below are some examples of what you can expect.<br />

SEWARD ProTag Optima 300<br />

Testing & Tagging System<br />

(SEW,PT-300)<br />

Setup:<br />

• Load logo file in printer<br />

• Load test settings<br />

Results <strong>Download</strong>ed:<br />

• Provide database in PATGuard<br />

format<br />

• Provide CD with PATViewer<br />

software including database for<br />

end customer<br />

FLUKE DTX1800 Cable Analyser<br />

(FLU,DTX1800)<br />

Setup:<br />

• Company name<br />

• Site<br />

• Tester<br />

• Setup of certification test limit<br />

• Cable type<br />

Results <strong>Download</strong>ed:<br />

• Raw Fluke Linkware files<br />

• Linkware software<br />

• PDF report of results<br />

FLUKE Ti25 Thermal Camera<br />

(FLU,TI25)<br />

Results <strong>Download</strong>ed:<br />

• Raw image files<br />

• Relevant editing software<br />

• Adjust isotherm and emissivity<br />

• Standard report of images<br />

CHK PM30/ PM30PLUS - 3CTs<br />

Power Quality Analyser<br />

[Note: Max current is 1000A for PM30]<br />

CHK PM40/ PM45 - 4CTs<br />

Power Quality Analyser<br />

(CHK,PM30)<br />

Setup:<br />

• 3P4W(star) or 3P3W(delta)<br />

• Max. Current (


General Industrial & Process Management<br />

www.techrentals.com.au<br />

Temperature Meters/IR Thermometers<br />

Infrared Thermal Imaging Cameras<br />

Endoscopes Borescopes Visual Inspection<br />

High Speed Video Inspection Cameras<br />

Tachometers/Stroboscopes<br />

Laser Rotational Shaft Alignment<br />

Industrial Process Calibrators<br />

Dry Block & Temperature Calibrators<br />

Strip Chart Recorders<br />

High Speed Waveform Recorders<br />

Data Loggers<br />

Pressure & Humidity Transducers<br />

Pressure Vacuum Gauges/Recorders<br />

Flow Meters for Liquids & Gases<br />

Combustion, Flue & Industrial Gas Analysers<br />

Environmental Test Chambers/Ovens<br />

Ultrasonic Baths<br />

Temperature Meters/<br />

IR Thermometers<br />

Fluke 52-2 Digital Thermometer<br />

FLU,52-2<br />

MY<br />

Dual input thermocouple thermometer supplied with two<br />

K type thermocouples for differential measurements.<br />

Sampling rate of 1Hz (1 probe) or 1.7Hz (2 probes). Will<br />

continuously record max and min measurements. It also<br />

can take K,J,T and E type Thermocouple inputs.<br />

Temperature range: K type: -200°C to 1,372°C.<br />

Fluke 54-2B 2 Channel Data Logging<br />

Temperature Meter with FlukeView<br />

FLU,54-2B-FVF (4507)<br />

AU<br />

Dual input digital thermometer with data logging. Will take<br />

most TC inputs. Accuracy ±0.05% of reading +0.3ºC. 500<br />

point logging with date & time stamp. Also records min,<br />

max or avg. Logged data can be reviewed on meter or<br />

downloaded to PC using software included. Supplied with 2 x<br />

400mm K type thermocouple leads.<br />

Fluke 80TK Thermocouple Module<br />

FLU,80TK (4531)<br />

AU<br />

Use with DVM’s and recorders. Accepts K thermocouples.<br />

Temperature range -50 to 1,000ºC. Output 1mV/ºC. Type<br />

80KP-1 probe included.<br />

Thermal Imaging<br />

Made Easy.<br />

Get focus-free<br />

imaging with<br />

IR-OptiFlex <br />

One-touch<br />

manual focus<br />

for close<br />

spaces<br />

New from Fluke.<br />

Our easiest-to-use<br />

thermal imagers ever.<br />

With simple, one-handed<br />

point-and shoot operation and<br />

revolutionary IR-OptiFlex focus<br />

system. Fluke Thermal Imagers<br />

offer focus-free images at four<br />

feet and beyond with manual<br />

focus for closer distances.<br />

Spend less time finding<br />

problems and more time fixing<br />

them. Thermal imaging has<br />

never been easier.<br />

See the new imagers in action:<br />

www.fluke.com.au<br />

AutoBlend<br />

identifies<br />

problem areas<br />

faster<br />

Point-and-shoot<br />

easy<br />

Thermal imaging has<br />

never been<br />

42


www.techrentals.com.au<br />

Temperature Meters/<br />

IR Thermometers cont’d.<br />

Fluke 576 Photographic Temperature Infrared<br />

Thermometer Built in Camera<br />

FLU,576 (4519)<br />

AU/MY<br />

Range -30 to 900ºC. Minimum measurement 19mmØ,<br />

laser class II, 3 point spot. Includes adjustable emissivity<br />

from 0.1 to 1 by 0.01. Target size 1/60 of distance. Max,<br />

min, dif and av displayed on backlit lcd with bar graph.<br />

Data output USB or 1mV/ºC, Windows software and<br />

cable included. Accuracy ±0.75% of reading or ±1ºC<br />

whichever is greater. Response time 250ms. Display<br />

resolution 0.1ºC. Continuous measure mode. Digital<br />

camera and flash built in.<br />

Hart 1521 NATA Precision Handheld<br />

Thermometer<br />

HAR,1521-NATA (4515)<br />

AU<br />

Accuracy 0.025ºC. Includes 5615 PRT probe ¼”Ø x 12” long. Calibrated in<br />

the -183 to 500ºC range. Probe operating range -200 to 420ºC (cable and<br />

transition to 150ºC max). ±0.024°C at -200°C, ±0.012°C at 0°C, ±0.035°C<br />

at 420°C.<br />

Hart 1523 NATA Precision Handheld Thermometer<br />

HAR,1523-NATA (4514)<br />

AU<br />

Precision, portable, electronic thermometer with trending and<br />

25 memory positions for NATA-traceable calibration and high<br />

accuracy. Includes 5616 probe 298mm x 6.35mm 100ohm<br />

platinum resistance thermometer probe (PRT) -200 to 420°C,<br />

stability ±10mK, accuracy ±0.012°C at -200°C, ±0.011°C at<br />

0°C, ±0.028°C at 420°C.<br />

Testo 845 IR Thermometer with<br />

Humidity Probe and T/C Probe<br />

TES,845 (4527)<br />

AU<br />

Temperature measurement -35 to 950°C. Relative humidity<br />

probe 0 to 100%RH. Fast-action surface probe with sprung<br />

thermocouple strip, also for uneven surfaces. Switchable<br />

optical resolution: far field: 75:1 (16mm at a distance<br />

of 1200mm). Close focus: 1mm at a distance of 70mm.<br />

Adjustable emissivity from 0.1 to 1, max, min, displayed<br />

on backlit LCD. Continuous measure mode. Data output<br />

software and cable included. Accuracy ±0.75% of<br />

reading 100 to 950°C. Display resolution 0.1°C.<br />

Infrared Thermal Imaging Cameras<br />

Flir E60 Infrared Thermal Image Camera<br />

FLI,E60 (4550)<br />

AU<br />

-20°C to 650˚C, IR resolution 320x240, 60Hz,<br />

visual image 3mpix, built in LED lamps, laser locator,<br />

scalable picture in picture. MPEG4 recording, touch<br />

screen, composite video out, Wi-Fi, and USB. Infrared<br />

camera applications include electrical distribution,<br />

mechanical (belts, rollers, couplings, gaskets/seals,<br />

compressors etc), product development, HVAC/R,<br />

automotive. Bluetooth support for voice annotations<br />

and selected Extech equipment. PC software provided.<br />

iPhone/iPad app available.


General Industrial & Process Management<br />

www.techrentals.com.au<br />

Infrared Thermal Imaging Cameras<br />

cont’d.<br />

Flir T400 Infrared Thermal Image Camera<br />

FLI,T400 (4557)<br />

AU<br />

-20°C to 1,200°C, 9Hz refresh rate. MPEG 4 video<br />

recording and composite out , is suitable for almost<br />

any application such as electrical surveys, building<br />

diagnostics and mechanical inspections. With a 3.5”<br />

touch screen, Fusion functionality, auto and manual focus, target illuminator,<br />

laser locator, voice text and sketch annotation.<br />

Fluke Ti25 Infrared Thermal<br />

Image Camera<br />

FLU,TI25 (4567)<br />

AU/MY<br />

Temperature range -20°C to 350°C, IR resolution<br />

320x240, 60Hz, visual image 3mpix, built in L,<br />

accuracy ±2°C or 2% (whichever is greater). Manual<br />

focus. SD memory card (2GB memory card will store at least 1200 fully<br />

radiometric (.is2) IR and linked visual images each with 60s voice annotations<br />

or 3,000 basic (.bmp) IR images). Infrared camera export file formats JPEG,<br />

BMP, GIF, P, TIFF, WMF, EXIF, and EMF. IP54 rating.<br />

Fluke Ti32 Infrared Thermal Image Camera<br />

FLU,TI32 (4559)<br />

AU/MY<br />

-20 to 600°C, resolution 320x240. Infrared<br />

camera applications include inside and outside electrical<br />

distribution, motors, pumps, generators, mechanical (belts,<br />

rollers, couplings, gaskets/seals, compressors etc). Process<br />

industry tanks/vessels, pipes, valves, traps, reactors, and<br />

process insulation, HVAC/R.<br />

Infrared Thermal Imaging Cameras<br />

cont’d.<br />

Fluke Ti32 Infrared Thermal Image Camera<br />

FLU,TI32_WIDE-ANGLE<br />

MY<br />

Field swappable, wide angle thermal lens allows the user to have a wider field<br />

of view for working in tight spaces, small rooms, etc. Field-of-View (FOV) is<br />

46° x 34°. For use with the Ti32 and TiR32.<br />

Fluke TiR32 Infrared Thermal Image Camera<br />

FLU,TIR32 (4563)<br />

AU<br />

Infrared thermal image camera. -20°C to 150°C,<br />

resolution 320x240. Applications include energy audits,<br />

building maintenance, restoration and remediation. Locate<br />

damaged or unsealed components of HVAC/R, air leakage<br />

from worn seals on windows and doors. Also features a Dew<br />

point alarm.<br />

Testo 880-3 V4 Professional Set Thermal<br />

Imaging System<br />

TES,880-3 V4 (4571)<br />

AU<br />

-20 to 350°C switchable. Display resolution 0.1°C. Continuous<br />

measure mode. Plug in T/C 350°C (Switchable). Infrared<br />

camera with intergrated digital camera equipped with power<br />

LEDs for dark area illumination. Applications include (but not limited to) In<br />

building thermography, electrical, mechanical and preventative maintenance,<br />

production and R&D monitoring, technical diagnostics, underfloor heating and<br />

mould growth detection. Includes software for report creation.<br />

Professional thermographer?<br />

Building inspector? Electrical inspector?<br />

FLIR Systems has the camera that’s right for you.<br />

FLIR i-Series<br />

The revolutionary FLIR i3, produces<br />

powerful snapshots of temperature<br />

differences equal to 3,600 readouts from<br />

a single spotmeter – the i5 and i7 models<br />

even more!<br />

FLIR E-Series<br />

The ground-breaking FLIR E-Series is<br />

packed with features like Bluetooth<br />

and industry-first Wi-Fi connectivity,<br />

3.5” touchscreen and smart phone<br />

App for iPhone and Android. Add to<br />

this MeterLink, the pioneering wireless<br />

connection that connects your IR camera<br />

with your ClampMeter.<br />

FLIR T-Series<br />

The new T-Series with optional MSX<br />

(Multi Spectral Dynamic Imaging) takes<br />

quality of image and ergonomics to<br />

a whole new level plus a long list of<br />

impressive features including Wi-Fi<br />

connectivity, 4.3” touchscreen, MeterLink<br />

and smart phone App for iPhone<br />

and Android.<br />

Local Service Network<br />

Who else would you trust to calibrate<br />

and service your FLIR camera but FLIR<br />

Australia? As a factory certified service<br />

centre it makes perfect sense. As most<br />

FLIR thermal cameras are eligible for<br />

FLIR’s industry leading 2-10 year product<br />

and detector warranties* buying a FLIR is<br />

an easy decision.<br />

FLIR Systems Pty Ltd. 10 Business Park Drive, Notting Hill, Victoria 3168, Australia<br />

VIC: 03 9550 2800 NSW: 02 8853 7870 WA: 08 6263 4438<br />

Tel AU: 1300 729 987 NZ: 0800 785 492 Email: info@flir.com.au www.flir.com<br />

*Terms and conditions apply<br />

44<br />

ISO No. FLIR20850


www.techrentals.com.au<br />

General Industrial & Process Management<br />

Endoscopes Borescopes<br />

Visual Inspection<br />

Endoscopes Borescopes Visual<br />

Inspection cont’d.<br />

See also Pipeline & Cavity Inspection on page 66<br />

Fibrescope MTFS15-1000 1.5mm x 1m Endoscope<br />

FIB,MTFS15-1000 (5127)<br />

AU<br />

Working length 1.5mmØ x 1,000mm. Includes light source. Operating<br />

temperature -20ºC to 60ºC at atmospheric pressure.<br />

Heine <strong>Tech</strong>no 6mm x 320mm T.05.26.302 Borescope<br />

HEI,TECHNO-6X320 (5175)<br />

AU<br />

Direction of view 70º, with angled extension tube 120º x 120º.<br />

Battery pack included, dc supply cord, battery charger and<br />

mains power pack.<br />

Moritex PalmScope Video Capture Device for<br />

JPEG & Movie Clip Recorder Inspection<br />

MOR,PALMSCOPE (5149)<br />

AU<br />

Digital Video Recorder, image capture and storage.<br />

Used in conjunction with an endoscope, borescope<br />

or videoscope the PalmScope is an alternative to a<br />

VCR for onsite inspection applications. Unit records, store video sequences<br />

and full frame resolution jpeg images on supplied 512Mb Compact Flash Card.<br />

View images on built in 6.4” TFT LCD screen. Stores jpeg still images and or<br />

mjpeg movie clips. Signal input video NTSC or PAL, auto-selecting.<br />

Olympus IF8C5-30 8mm Diameter, 3m Length Optical Fibre<br />

Endoscope<br />

OLY,IF8C5-30 (5160)<br />

AU<br />

3.25m long (effective 3m), 8mm diameter, angulation range, 4 direction,<br />

Up, Down 120º, Right, Left 100º, light guide cable length 2m. Optical<br />

adaptor fitted AT60DFF, field of view 60º, forward viewing, depth of field<br />

20mm to infinity. Outer diameter 8.4mm. Operating temperature in air<br />

-10 to 80ºC, in water 10 to 30ºC. Operating pressure in air/water 1013 to<br />

1317hPa (1-1.3 atm) In air 1013hPa (1-1.3atm). Fluid resistance insertion tube<br />

withstands machine oil, light oil. Can insert insertion tube only in water.<br />

Supplied with eye piece and light source.<br />

Olympus IPLEX- MX Portable Industrial<br />

Videoscope<br />

OLY,IPLEX-MX (5170)<br />

AU<br />

Battery powered industrial videoscope,<br />

lightweight just 4.5kg out of transit case. 6mmØ,<br />

3m length tungsten insertion tube, articulation 4 way up/down/left/right 120º.<br />

Field of view 120º, depth of field 18mm to infinity, illumination method LED.<br />

Brightness adjustment 11 step, long exposure up to 1sec, zoom electronic<br />

linear up to 3x, built in 5.6inch TFT full colour display, image recording built in,<br />

image format JPEG, over 230 images with supplied CF card. Powered from<br />

either rechargable Li-ion 2 x battery packs (4h) or AC adaptor.<br />

Olympus IPLEX- MX II Portable<br />

Industrial Videoscope<br />

OLY,IPLEX-MXII (5169)<br />

AU<br />

Battery powered industrial vidoscope,<br />

lightweight, just 2.5kg out of transit case.<br />

6mmØ, 3m length tungsten insertion tube,<br />

articulation 4 way UP/DOWN/LEFT/RIGHT 120º. Field of view 120º, depth<br />

of field 18 to 1000mm, illumination method LED. Brightness adjustment and<br />

digital zoom, built in 6.5” TFT colour display, record JPEG images to USB<br />

flash device. RCA composite video output. Battery or AC powered.<br />

Olympus IPLEX-LX<br />

Portable Industrial<br />

Videoscope<br />

OLY,IPLEX-LX<br />

MY<br />

Battery powered industrial videoscope,<br />

lightweight 2.7kg out of transit case. 4mmØ, 3.5m length tungsten insertion<br />

tube, articulation 4 way up/down/left/right 120°. Field of view 120°, depth<br />

of field 18 to 1,000mm, illumination method LED. Brightness adjustment<br />

and digital zoom, built in 6.5inch TFT colour display, record JPEG images<br />

and video to USB flash device. RCA composite video output. Battery or AC<br />

powered.<br />

Olympus IV6C6-20-ZOOM Videoscope<br />

6mm x 2m Long<br />

OLY,IV6C6-20-ZOOM (5167)<br />

AU<br />

Fitted with AT120D/NF optical adaptor, field of view<br />

120º, direction of view forward, depth of field 5mm to<br />

infinity. Angulation 4 way, 150º up/down & left/right,<br />

heavy duty tungsten insertion braid tube. Operating<br />

temperature for insertion tube in air -10 to 80ºC, in<br />

water 10 to 30ºC. Liquid resistance for insertion tube - withstands machine<br />

oil, light oil and 5% salt water. Supplied with IV-6A video control unit, which<br />

has zooming and virtual scrolling (panning) with moving images function,<br />

extended exposure time for darker areas, built in image enhancement and<br />

freeze frame. ILH-2B light source, Panasonic 7” LCD colour monitor mounted<br />

on extension arm all fitted to transit case for ease of use. Video VHS recorder<br />

also included in package.<br />

RF Systems VJ-ADV<br />

Articulating 3.9mm Video<br />

Borescope<br />

RFS,VJ-ADV (5165)<br />

AU<br />

Video borescope is 3.9mm in diameter and 1.5<br />

meters long with a flexible stainless steel braided<br />

insertion tube with adjustable brightness and<br />

90 degree 4 way articulation. Images and video<br />

can be captured and saved to a micro SD card. Applications include turbine<br />

inspection, heat exchangers, gearboxes in automotive or electrical power<br />

generation, chemical, oil and gas vessel inspection.<br />

High Speed Video Inspection<br />

Cameras<br />

Casio Exilim Ex-F1 High Speed Camera<br />

& Lighting Kit<br />

CAS,EX-F1 (5133)<br />

AU<br />

Has two operating modes one as a high speed video<br />

camera it will record 1200 frames per sec @ 336x96<br />

pixels resolution. Secondly as a high speed still<br />

camera it will record 60 frames per second @ 2816 x<br />

2112 pixels resolution. This gives considerable detail<br />

at a high frame rate. The fastest shutter speed is<br />

1/40,000 sec. It includes a x12 zoom and complete<br />

lighting setup and stands.<br />

Olympus High Speed Camera<br />

OLY,ISPEEDLT (5130)<br />

AU<br />

High speed video camera including stand and lighting<br />

accessories. 800x600 color resolution at 1,000fps.<br />

Maximum frame rate 2,000fps. 2.24sec recording time<br />

color camera. 4 x lens kit supplied. Maximum shutter<br />

speed 5us.<br />

45


General Industrial & Process Management<br />

www.techrentals.com.au<br />

Tachometers/Stroboscopes<br />

Hioki 3404 Optical/Contact Tachometer<br />

HIO,3404 (5105)<br />

AU/MY<br />

Autoranging 4 digit display. Ranges in RPM mode 30 to 99.9, 1,000 to 9,999 &<br />

1,000 to 9,999 x 10. Ranges in RPS mode 0.5 to 99.99, 100 to 999.9 & 1,000<br />

to 1,600. Analogue output 1mV/10RPM or 1mV/100RPM, accuracy 4%. Tripod<br />

mounting. Internal battery or external AC operation. Contact adaptor included<br />

with cone and peripheral ring.<br />

Monarch Palmstrobe Compact Size Portable Stroboscope<br />

MON,PALMSTROBE (5103)<br />

AU<br />

Compact size portable stroboscope, flash rate from 100 to<br />

12,500FPM, 6 digit alphanumeric backlit LCD. Tachometer<br />

range 5 to 250,000RPM (only with external sensor connected,<br />

not included). External sensor input TTL only. Supplied with 2 x<br />

removable rechargeable battery packs, charger and transit case.<br />

Monarch Phaser Strobe Battery Operated<br />

MON,PHASER (5101)<br />

AU<br />

Phaser-stroboscope includes optical and magnetic pickup. Operates from<br />

internal re-chargable batteries or mains. Auto step mode provides slow<br />

motion appearance for high speed repetitive events. Stores and recalls last<br />

3 full settings in memory. Specifications: 30 to 30,000 fpm or 0.5-533.33 fps.<br />

Accuracy ±0.01%. Flash rate external triggering: 30 to 9,999.9 fpm, 0.5 to<br />

533.33 fps, 10,000 to 32,500 fpm. Phase delay facility.<br />

Monarch PLT200-KIT Digital<br />

Contact/Non Contact Tacho<br />

MON,PLT200-KIT (5106)<br />

AU<br />

Hand held digital contact/non-contact tacho kit.<br />

Ranges optical/non-contact 5 to 200,000 RPM,<br />

contact 0.5 to 20,000 RPM. Display 5 digits, 5 alpha<br />

numeric LCD. Non contact operating range 90cm,<br />

tripod mounting. Direct contact tips and contact wheel<br />

supplied. Programmable for IPM, FT/M, YPM, cm/M,<br />

m/M, RPM, RPS, RPH and Totaliser up to 200,000.<br />

Output TTL pulse.<br />

Laser Rotational Shaft Alignment<br />

Fixturlaser Dirigo Laser Bases Shaft Alignment System<br />

FIX,DIRIGO (4940)<br />

AU<br />

Measurement resolution to 0.01mm Shaft diameter range 40<br />

to 150mm using an extension chain 150 to 500mm. Maximum<br />

distance between measurement units 0.85m. Very simple to<br />

use and operate as shims are applied the alignment can be<br />

monitored in real time. 20h of operation from alkaline batteries.<br />

Fixturlaser PAT Pulley Alignment System<br />

FIX,PAT (4941)<br />

AU<br />

Laser based alignment system for pulley systems. Measurement accuracy<br />

0.5mm (0.2º). 20hrs of operation on AAA batteries. Mechanically self centres<br />

on pulley, will operate successfully even on worn pulley systems.<br />

MCE Pipe Laying Laser<br />

Alignment System<br />

MCE,LS140G (4940)<br />

AU<br />

Pipe laying laser alignment system.<br />

Simple system for setting pipe grades.<br />

Applications include sanitary and storm sewers,<br />

tunnelling and Pipe Jacking. It includes a remote<br />

to adjust the grade and left right alignment. Kit<br />

includes target, remote and legs for different pipe sizes etc. This system uses<br />

the green laser wich is considerably brighter than a red laser.<br />

Laser Rotational Shaft Alignment<br />

cont’d.<br />

Pruftechnik Rotalign Pro Laser Shaft<br />

Alignment Ex<br />

PRU,ROT-PROEX (4943)<br />

AU<br />

Laser based rotating shaft alignment system.<br />

Maximum separation between emitter and receiver<br />

10m. Aligns horizontal and vertical machines,<br />

coupled and uncoupled shafts equally well.<br />

Intrinsically safe system.<br />

Pruftechnik Rotalign Ultra<br />

Laser Shaft Alignment<br />

PRU,ROT-ULTRA (4945) AU<br />

Laser based rotating shaft alignment<br />

system. Maximum separation between<br />

emitter and receiver 10m. Aligns<br />

horizontal and vertical machines, aligns<br />

coupled and uncoupled shafts equally<br />

well. Ultra modern computer design, backlit colour display, Intel XScale<br />

400MHz CPU, USB for peripheral devices, PC, printer, also Bluetooth<br />

communication. Backlit keyboard, rechargeable Li-Ion battery pack. Machine<br />

train alignment - 14 machines. Alignment results in 3 quick steps, thermal<br />

growth computation. Rotalign Ultra Reader software included.<br />

Pruftechnik 1500mm Length Tension Chains<br />

PRU,AL12.116 (4946)<br />

1500mm length tension chains for PRU,ROT-ULTRA.<br />

Industrial Process Calibrators<br />

See also Laboratory Calibrators on page 10<br />

Ametek PPCE 700Bar Pressure Calibrator<br />

AME,PPCE<br />

MY<br />

High pressure calibrator with pump 700Bar (10,000psi). Digital display with<br />

5 digit resolution. Accuracy over 70Bar ±0.07. Accuracy below 70Bar ±0.35.<br />

Current and voltage measurement ranges 4 to 20mA, 0 to 50mA & 0 to 30V.<br />

Ametek Hydralyte HL2700N Dead Weight Tester<br />

AME,HL2700N<br />

MY<br />

Dual range interchangeable piston: 100 to 4,500kPa, 0.5kPa increments,<br />

500 to 22,500kPa, 1kPa increments. Accuracy 0.05% of reading.<br />

Includes special calculator for high accuracy pressure calculations and also<br />

conversion of units.<br />

Beamex MC5 Multifunction NATA Calibrator<br />

BEA,MC5 (4727)<br />

AU<br />

NATA certified MC5 provides calibration capability<br />

for pressure, temperature, electrical and frequency<br />

signals. HART communication and CMX light<br />

software provided. Calibration results can be stored<br />

or printed. Performs as a field-entry device (FED)<br />

allowing for the recording of non-calibration related<br />

maintenance results. Pressure modules included,<br />

-1 to 20Bar and 600Bar (up to 1,000Bar with<br />

optional external transducers). DC voltage & current, frequency, and pulse<br />

measurement. RTD, thermocouple, and resistance simulation & measurement.<br />

The fi lm symbol indicates there<br />

is a ‘how to video’ online for that<br />

product, see page 1.<br />

AU<br />

46


General www.techrentals.com.au Industrial & Process Management General Industrial & Process Management<br />

www.techrentals.com.au<br />

Industrial Process Calibrators cont’d.<br />

Beamex MC5 Intrinsically Safe Multifunction<br />

NATA Calibrator<br />

BEA,MC5-IS (4728)<br />

NATA certified MC5-IS provides calibration capability<br />

for pressure, temperature, electrical and frequency<br />

signals. HART communication and CMX light software<br />

provided. Calibration results can be stored or printed.<br />

Performs as a Field-Entry Device (FED) allowing for the recording of noncalibration<br />

related maintenance results. Pressure measurement range, -1 to<br />

20Bar and 600Bar (up to 1,000Bar with optional external transducers). DC<br />

voltage and current, frequency, and pulse measurement. RTD, thermocouple,<br />

and resistance simulation and measurement.<br />

Beamex MC6 Advanced Field<br />

Calibrator<br />

BEA,MC6 (4725)<br />

AU<br />

NATA certified MC6 provides calibration capability<br />

for pressure, temperature, electrical and frequency<br />

signals. HART communication and CMX light<br />

software provided. Calibration results can be<br />

stored or printed. Performs as a field-entry device (FED) allowing for the<br />

recording of non-calibration related maintenance results. Pressure modules<br />

included, -1 to 20Bar and 600Bar (up to 1,000Bar with optional external<br />

transducers). DC voltage & current, frequency, and pulse measurement.<br />

RTD, thermocouple, and resistance simulation & measurement. Colour touch<br />

screen.<br />

Beamex PGXH, PGM and PGV<br />

BEA,PUMPS (4773)<br />

AU<br />

Hand pumps includes hand-held, lightweight pressure<br />

and vacuum sources for field use. The PG series of hand<br />

pumps are ideal pressure/vacuum generators to be used<br />

as accessories for pressure and vacuum calibration. Kit<br />

contains PGXH 0 to 700Bar, PGM 0 to 20Bar, PGV 0 to<br />

-0.95Bar.<br />

Crystal nVision Pressure Calibrator 30Bar<br />

IS NATA<br />

CRY,NVISION-30-NATA (4730)<br />

AU<br />

Intrinsically safe pressure calibrator. Displays real-time<br />

recorded data graphically on a high res screen with ability<br />

to zoom into specific events. 500,000 data point memory<br />

records all data from all enabled screens from two modules<br />

simultaneously. Fastest logging interval 10 readings/sec.<br />

Configured with MA20 current, voltage and switch test module and 30Bar<br />

pressure module, accuracy to 0.025% of reading. Includes hand pump and<br />

CPF (finger tight to 700Bar) fittings.<br />

Crystal XP2i 15psi (1Bar)<br />

NATA with Druck PV411<br />

Hand Pump<br />

CRY,XP2I CAL KIT 1 (4733)<br />

AU<br />

15psi (1Bar) pressure gauge and Druck<br />

PV411 hand pump calibration kit. Nata<br />

certified accuracy, ±0.1% of reading between<br />

20 to 100% of full scale, ±0.02% of full scale<br />

between 0 to 20% of full scale.<br />

Crystal XP2i 100psi<br />

(7Bar) NATA with Druck<br />

PV411 Hand Pump<br />

CRY,XP2I CAL KIT 7 (4736)<br />

AU<br />

100psi (7Bar) pressure gauge and PV411<br />

hand pump calibration kit. Nata certified<br />

accuracy, ±0.1% of reading between 20<br />

to 100% of full scale, ±0.02% of full scale<br />

between 0 to 20% of full scale.<br />

Industrial Process Calibrators cont’d.<br />

Crystal XP2i 5,000psi<br />

(345Bar) NATA with<br />

Druck PV411 Hand Pump<br />

CRY,XP2I CAL KIT 345 (4739)<br />

AU<br />

5,000psi (345Bar) pressure gauge and<br />

PV411 hand pump calibration kit. Nata<br />

certified accuracy, ±0.1% of reading between<br />

20 to 100% of full scale, ±0.02% of full scale<br />

between 0 to 20% of full scale.<br />

Druck DPI603 2-NATA 2Bar Pressure Calibrator<br />

DRU,DPI603-2-NATA (4750)<br />

AU<br />

DRU,DPI603-2<br />

MY<br />

0.075% FS Accuracy includes pump for vacuum and<br />

pressure. Unit will pump up to 2Bar pressure and<br />

-850mBar vacuum. Measurements can be made to 2Bar<br />

positive pressure and -1Bar vacuum. The unit has a 24V<br />

energising voltage. Monitors loop current to<br />

55mA DC loop voltage to 50V. Sealed to IP65.<br />

Rechargeable battery operated. Unit can display in 24<br />

different units. BSP 1/8 interface.<br />

Druck DPI603 20Bar Pressure Calibrator<br />

DRU,DPI603-20<br />

MY<br />

Accuracy 0.075%fs. Pumps up to 20Bar pressure & -850mBar vacuum.<br />

Measures up to 20Bar pressure and -1Bar vacuum. In-built 24V energising<br />

voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface 1/8”<br />

bsp. Battery operated.<br />

Druck DPI104 350Bar Pressure Calibrator & HTP1 Hydraulic Pump<br />

DRU,DPI104-350<br />

MY<br />

Range 0 to 350Bar. Measures 0 to 100mV (1μV resolution), 0 to 5V (0.1mV<br />

resolution), 0 to 50V (1mV resolution) & current 0 to 50mA (1μA resolution) all<br />

@ 0.025% accuracy. Sources 0 to 10V (0.2mV resolution) & 0 to 50mA (1μA<br />

resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1%<br />

current 30mA & unregulated supply 24V ±10% current 50mA. Pressure<br />

switch status. Pressure media oil, water & non corrosive gases. Battery<br />

operation 10h or mains operation via charger. Complete with a full range of<br />

pressure connection adaptors.<br />

Druck DPI610-2-NATA 2Bar Pressure Calibrator<br />

DRU,DPI610-2-NATA (4752)<br />

AU<br />

DRU,DPI610-2<br />

MY<br />

Pneumatic pressure calibrator including pump and<br />

current voltage standard. Pressure range -1 to 2Bar,<br />

±0.025%fs. Voltage input ±50VDC, ±0.05%rdg,<br />

±0.004%fs. Current input ±55mA, ±0.05%rdg,<br />

±0.004%fs. Temperature -10 to 40°C, ±1 (ambient)<br />

switch open/closed. Voltage output 10VDC, ±0.1% or<br />

24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger stores<br />

up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes<br />

flexible hose kit. Pump includes screw adjustment.<br />

Druck DPI610-20-NATA 20Bar Pressure Calibrator NATA Certification<br />

DRU,DPI610-20-NATA (4754)<br />

AU<br />

DRU,DPI610-20<br />

MY<br />

Pneumatic pressure calibrator including pump and current voltage standard.<br />

Pressure range -1 to 20Bar ±0.025%fs. Voltage input ±50VDC, ±0.05%rdg,<br />

±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature -10<br />

to 40°C ±1°C (ambient) switch open/closed. Voltage output 10VDC ±0.1%<br />

or 24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger<br />

stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8f,<br />

includes flexible hose kit. Pump includes screw adjustment.<br />

47


General Industrial & Process Management<br />

www.techrentals.com.au<br />

Industrial Process Calibrators cont’d.<br />

Industrial Process Calibrators cont’d.<br />

Druck DPI610-20IS 20Bar Pressure Calibrator<br />

DRU,DPI610-20IS<br />

MY<br />

Ranges -1 to 20Bar. Accuracy 0.025% fs all ranges. Integral combined<br />

pressure/vacuum pump. Dual readout: input & output. 4 to 20mA loop test:<br />

auto step and ramp. RS232 interface and fully documenting version. Remote<br />

pressure sensors. Intrinsically safe version.<br />

Druck DPI610-400-NATA 400Bar Pressure Calibrator<br />

DRU,DPI610-400-NATA (4758)<br />

AU<br />

DRU,DPI610-400<br />

MY<br />

Hydraulic pressure calibrator including pump and current voltage standard.<br />

Pressure range 0 to 400Bar ±0.025%fs. Voltage input 50VDC, ±0.05%rdg,<br />

±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature -10 to<br />

40ºC ±1ºC (ambient) switch open/closed. Voltage output 10VDC ±0.1% or 24V<br />

±5%. Current output 0 to 24mA, ±0.05% rdg, ±0.01%fs. Data logger stores<br />

up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes<br />

flexible hose kit. Pump includes screw adjustment.<br />

Druck DPI615-20-NATA 20Bar<br />

Pressure Calibrator<br />

DRU,DPI615-20-NATA (4756)<br />

AU<br />

Pneumatic pressure calibrator including pump and<br />

current voltage standard. Pressure range 0 to 20Bar<br />

±0.025% FS. Voltage input ±50VDC ±0.05% rdg<br />

± 0.004% FS. Current input ±55mA ±0.05%rdg<br />

±0.004%FS. Temperature -10 to 40ºC ±1ºC (ambient)<br />

switch open/closed. Voltage output 10VDC ±0.1% or<br />

24V ±-5%. Current output 0 to 24mA ±0.05%rdg<br />

±0.01%FS. Data logger stores upto 10,000 values. mA ramp configurable.<br />

Pressure port G 1/8 female, includes flexible hose. Pump includes screw<br />

adjustment.<br />

Druck PV411A Multifunction Hand Pump Kit<br />

DRU,PV411A (4771)<br />

AU/MY<br />

Provides up to 700Bar hydraulic, 40Bar pneumatic<br />

pressures and vacuum to -950 mBar. Built-in stroke<br />

adjuster, lower pressure fine control and tamper proof<br />

overpressure protection.<br />

Druck UPS III-IS Intrinsically Safe Loop Calibrator<br />

DRU,UPS III-IS (4777)<br />

AU<br />

Measure or source 0 to 24mA and provide 24V loop power.<br />

50 VDC measurement and continuity. Accuracy 0.015% of<br />

reading, Hart compatible. Dual mA and % readout, linear<br />

or flow. It is an essential tool for loop testing, instrument<br />

maintenance and valve set-up, with an easy-to-read<br />

display and simple-to-use time saving features.<br />

Emerson Process Management 375<br />

Field Communicator<br />

EME,375 (4781)<br />

AU/MY<br />

Will configure, test, and diagnose your<br />

HART® and Foundation FieldBus devices.<br />

Able to communicate with any device, by<br />

any manufacturer. Intrinsically safe. Easy<br />

upgrade over the Internet. Interfaces with<br />

AMS PC Suite Software.<br />

Emerson 475 Hart Communicator<br />

EME,475 (4779)<br />

AU/MY<br />

Will configure, test, and diagnose your HART® and<br />

Foundation FieldBus devices. Able to communicate with<br />

any device, by any manufacturer. Intrinsically safe. Easy<br />

upgrade over the Internet. Interfaces with AMS PC Suite<br />

Software.<br />

Softing BC-600-PB Profibus Tester 4<br />

SOF,PROFIBUS-4 (4775)<br />

AU<br />

Allows full testing of live PROFIBUS segments with<br />

minimum influence on their operation. Detects transient<br />

faults that occur sporadically. Test for non operation PLCs<br />

or suspicious devices. Simultaneous analysis of both bus<br />

physics and bus communication. Master simulator and<br />

Topology scan. Expert tests: frame, oscillogram analysis<br />

and trigger input/output. Long term trend measuring,<br />

preventive maintenance and detailed test reporting.<br />

Fitting Set with 700Bar Hose<br />

FIT,HP<br />

MY<br />

Fitting set (max pressure = 10,000psi) for pressure calibrators. Female<br />

connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP & NPT; 3/8 inch BSP &<br />

NPT; 1/2 inch BSP & NPT.<br />

Fitting Set With 20Bar Hose<br />

FIT,LP<br />

MY<br />

Fitting set (max pressure = 10,000psi) for pressure calibrators. Female<br />

connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP & NPT; 3/8 inc BSP &<br />

NPT; 1/2 inch BSP & NPT.<br />

Fluke 70Bar Pressure Transducer to suit Fluke<br />

Calibrators 725 & 744<br />

FLU,700P08-70BAR (4764)<br />

AU<br />

For use with the Fluke 744 & 725 industrial calibrators.<br />

Pneumatic system range 0 to 70Bar, resolution<br />

7mBar, reference uncertainty 0.025%. Connection 1/4<br />

NPT and 1/4 ISO. Includes 700PTP-1 pressure pump.<br />

(Note the pump will operate to 41Bar).<br />

Fluke 690Bar Pressure Transducer to suit<br />

Calibrators 744 & 725<br />

FLU,700P31-690BAR (4765)<br />

AU<br />

For use with the Fluke 744 & 725 industrial calibrators.<br />

Range 0 to 690Bar, reference uncertainty .025%.<br />

Connection 1/4 NPT and 1/4 ISO Includes 700LTP-1<br />

pressure pump.<br />

Fluke 7Bar Pressure Transducer & Pump to suit FLU,744 & FLU,725<br />

FLU,700PD6-7BAR (4763)<br />

AU<br />

For use with the Fluke 744 & &25 industrial calibrators. Range 100 to 690kPa,<br />

reference uncertainty .025%. Connection 1/4 NPT and 1/4 ISO Includes<br />

700LTP-1 pressure pump.<br />

Fluke 718 300G Pressure Calibrator<br />

FLU,718-300G (4793)<br />

AU<br />

Pressure source and milliamp measurement. Pressure<br />

specs -83 to 2068kPa ±0.05% of range. Max pressure<br />

2.6MPa. Current specs: 0.0001mA resolution,<br />

accuracy 0.015%. Calibrate P/I (pressure to current)<br />

transmitters, measures pressure via a 1/8 inch NPT<br />

pressure fitting and an internal pressure sensor, source<br />

pressure, measure current up to 24mA, simultaneously<br />

display pressure and current measurements, supplies<br />

loop voltage, calculates percentage in percent mode,<br />

calculates mA error in percent error mode.<br />

Fluke 719 2Bar-30G Pressure Calibrator including Electric Pump<br />

FLU,719-30G (4795)<br />

AU<br />

2Bar, includes pump and precision 4 to 20mA measurement and source<br />

capability. The pump in this instrument is electric. Uncertainty 0.025%.<br />

Precision pressure adjustment vernier. Range -850mBar to 2Bar. Resolution<br />

0.1mBar. 4 to 20mA resolution .001mA .015%rdg + 2 counts.<br />

48


www.techrentals.com.au<br />

General Industrial & Process Management<br />

Industrial Process Calibrators cont’d.<br />

Fluke Pressure Calibrator 8Bar Includes Electric Pump<br />

FLU,719-100G (4764)<br />

AU<br />

8Bar, includes pump and precision 4 to 20mA measurement<br />

and source capability. The pump in this instrument is<br />

electric. Uncertainty 0.025%. Precision pressure adjustment<br />

vernier. Range -850mBar to 8Bar. Resolution 1mBar. 4 to<br />

20mA resolution 0.001mA 0.015%rdg + 2 counts.<br />

Fluke 725 Process Calibrator<br />

FLU,725-NATA (4783)<br />

AU<br />

FLU,725<br />

MY<br />

DC voltage measurement 0.025%, 300V max, source<br />

0.02%, 11V max. DC current measurement 0.025%, 110mA<br />

max, source 0.01%, 22mA max. Resistance measurement<br />

0.05%, 11kΩ max, source 0.01%, 1 1kΩ max. Frequency<br />

measurement 5 counts 1Hz to 50kHz, source 1 count<br />

20Hz to 5kHz. ‘K’ thermocouple measurement 0.3ºC,<br />

source 0.3ºC. Pt100 RTD measurement 0.5ºC, source<br />

0.2ºC. Measures and simulates 4 to 20mA, t/c E,N, J, K, T,<br />

B, R, S, & C, 2, 3 & 4 wire RTDs and frequency. Operates<br />

from drycell batteries. (Includes NATA calibration - AU).<br />

Fluke 726 Process Calibrator<br />

FLU,726<br />

MY<br />

Precision multifunction process calibrator. DC voltage<br />

measurement. 0.010% 30V max, source 0.010% 20V max.<br />

DC current measurement. 0.010% 24mA max, source<br />

0.01% 24mA max. Resistance measurement 0.015% 4kΩ<br />

max, source 0.01% 4kΩ max. Frequency measurement<br />

5 counts 1Hz to 15kHz, source 1 count 20Hz to 15kHz.<br />

Will measure and simulate 4 to 20mA, TC E N J K T B R S<br />

and C, 2, 3 and 4 wire RTDs and frequency. Loop power<br />

supply at: 24V, 22mA. Pulse Source 10k and read 100k.<br />

The unit operates from drycell batteries.<br />

Fluke 743 Calibrator<br />

FLU,743B<br />

MY<br />

Includes RS232 interface. DC voltage measurement 0.025%, 300V max,<br />

source 0.01%, 15V max. DC current measurement 0.025%, 110mA max,<br />

source 0.01%, 22mA max. Resistance measurement 0.05%, 11kΩ max, source<br />

0.01%, 11kΩ max. Frequency measurement 0.5%, +5, 40 to 500Hz, source<br />

1 count 20Hz to 5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC<br />

Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates 4<br />

to 20mA, t/c E, N, J, K, T, B, R, S, & C, 2, 3 & 4 wire RTDs, frequency, test<br />

limit switches. Can use scaling factors for measurement & source. Built in<br />

calculator. Autostep function. Allows user entered values. Operates as an 8k<br />

point data logger. Note PC software only supports 15 tags.<br />

Fluke 744 DOC Calibrator with Hart<br />

FLU,744 (4785)<br />

AU/MY<br />

Documenting process calibrator which includes HART<br />

communication protocols for communicating with and setting up smart<br />

transmitters. RS232 interface. DC voltage measurement 0.025%, 300V max,<br />

source 0.01%, 15V max. DC current measurement 0.025%, 110mA max,<br />

source 0.01% 22mA max. Resistance measurement 0.05%, 11kOhm max,<br />

source 0.01% 11kOhm max. Frequency measurement 0.5%, +5, 40~500Hz,<br />

source 1 count 20~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC<br />

Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates<br />

4~20mA, t/c E, N, J, K, T, B, R, S & C, 2, 3 & 4 wire RTDs, frequency, test limit<br />

switches. Uses scaling factors for measurement & source. Built in calculator.<br />

Autostep function. Allows user entered values. Operates as an 8k point data<br />

logger. Note PC software only supports 15 tags.<br />

Industrial Process Calibrators cont’d.<br />

Fluke 773 Milliamp Process Clamp Meter<br />

FLU,773 (4787)<br />

AU<br />

Measure 4 to 20mA control lines, PLC loops, transmitters<br />

or any 4 to 20mA line without breaking the loop. Capable<br />

of 0 to 20.99mA and 24 to 100mA with clamp. Source<br />

and simulate mA and voltage signals in circuit. 4 to 20mA<br />

scaled o/p.<br />

Fluke 789 Process Meter<br />

FLU,789 PROCESSMETER (4798)<br />

AU<br />

Standard multimeter functions with 2 to 20mA sink and source capability,<br />

including a 24V supply. HART 250Ω resistor, 20mA drive into 1,200Ω.<br />

Simultaneous mA and % of scale readout on mA output. 25% manual step<br />

plus auto step and auto ramp on mA output. Min/max/average/hold/relative<br />

modes. Double size dual display. Accuracy, VDC 0.1% +1, VAC 0.7% +2, mA<br />

DC 0.05% +2, frequency 0.005% +1.<br />

Jofra DPC-500 Documenting Pressure<br />

Calibrator 1000Bar NATA<br />

JOF,DPC-1000-NATA (4748)<br />

AU<br />

Documenting pressure calibrator is used for<br />

high precision calibration of pressure gauges,<br />

pressure transmitters, digital manometers,<br />

pressure switches, overpressure protection<br />

valves etc. Measure pressure at 1,000Bar or 14,500psi, voltage 0 to 10V,<br />

current 0 to 20mA and 4 to 20mA, and supplies 24VDC as source for<br />

transmitters. Accuracy ±0.025% F.S. Supplied with Druck PV212 1,000Bar<br />

hand pump and calibration software. 15 user selectable engineering units<br />

including user defined. Nata Calibrated.<br />

SI PC6 20Bar NATA Pressure Calibrator & Pump<br />

SI,PC6-20-NATA (4767)<br />

AU<br />

Basic accuracy 0.025%. Range output pressure to 20Bar, output vacuum<br />

to -1Bar. NATA certified Instrument. Measures voltage 0~100mV (1μV<br />

resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) and current<br />

0~50mA (1μA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />

resolution) & 0~50mA (1μA resolution) also at 0.025% accuracy. Voltage<br />

output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />

±10% current 50mA. Pressure switch status. Battery operation 10h or mains<br />

operation via charger.<br />

SI PC6 35Bar NATA Pressure Calibrator & Pump<br />

SI,PC6-35-NATA (4768)<br />

AU<br />

Basic accuracy 0.025%. Range is 35Bar. Measures voltage 0~100mV (1μV<br />

resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current<br />

0~50mA (1μA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />

resolution) & 0~50mA (1μA resolution) also at 0.025% accuracy. Voltage<br />

output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />

±10% current 50mA. Pressure switch status. Complete with a full range of<br />

pressure connection adaptors. Record logging capability 444 and RS232<br />

interface download to spread sheet files. Battery operation 10h or mains<br />

operation via charger.<br />

SI PC6 700Bar Pressure Calibrator and HTP1 Hydraulic Pump NATA<br />

Calibrated<br />

SI,PC6-700-NATA (4769)<br />

AU<br />

SI,PC6-700<br />

MY<br />

Range 0 to 700Bar. Measures 0 to 100mV (1μV resolution), 0 to 5V (0.1mV<br />

resolution), 0 to 50V (1mV resolution) & current 0 to 50mA (1μA resolution) all<br />

@ 0.025% accuracy. Sources 0 to 10V (0.2mV resolution) & 0 to 50mA (1uA<br />

resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current<br />

30mA and unregulated supply 24V ±10% current 50mA. Pressure switch<br />

status. Pressure media oil, water & non corrosive gases. Battery operation<br />

10h or mains operation via charger.<br />

49


General Industrial & Process Management<br />

www.techrentals.com.au<br />

Dry Block Calibrators<br />

Strip Chart Recorders<br />

Grant GR150-S5<br />

Temperature Bath NATA Calibrated<br />

GRA,GR150-S5-NATA (4744)<br />

AU<br />

Water/oil bath and circulator for calibrating temperature<br />

probes and analytical procedures. Temperature ranges<br />

from ambient to 100ºC with water and 150ºC with silicon<br />

oil. Requires 3L oil (not supplied). Stability 0.005ºC,<br />

uniformity 0.02ºC and display resolution 0.1ºC. Tank<br />

size 300mm W x 150mm D x 150mm H. Features<br />

include digital temperature controller and display, pump, timer, alarms, offset<br />

adjustment and more.<br />

Hart 9141 Dry Block Temperature Calibrator 50 to 650ºC<br />

HAR,9141-NATA (4738)<br />

AU<br />

Range 50 to 650°C, basic accuracy 0.5%. Insert hole sizes 1.6mm(1/16”),<br />

3.2mm(1/8”), 4.8mm(3/16”), 6.4mm(1/4”), 9.5mm(3/8”) and 12.7mm(1/2”).<br />

Includes PC software and interface cable. Heating time 1min to 650°C.<br />

Cooling 25min from 650 to 100°C. Well depth 4.875”. Stabilization time 7min.<br />

Hart 9170-R Dry Block Temp Calibrator -45 to 140°C<br />

HAR,9170-R-NATA (4732)<br />

AU<br />

Metrology well calibrator. Temperature range -45 to<br />

140°C with built in reference thermometry. Reference<br />

input accepts (not supplied) 100, 25 and 10 ohm PRT’s.<br />

Display accuracy ±0.1°C, stability ±0.005°C full range,<br />

resolution 0.001°C. Well depth 160mm (6.3”), insert<br />

type A, 3 x 6.4mm(1/4”), 4.8mm(3/16”), 3.2mm(1/8”),<br />

5.9mm(3/8”). Large LCD, numeric keypad and on<br />

screen menus.<br />

Jofra C650 Calibrator<br />

JOF,C650<br />

MY<br />

A fast, timesaving, and reliable true temperature<br />

calibrator designed for on-site use. Produces<br />

temperatures between 33 to 650°C. Display resolution<br />

±0.1°C, accuracy ±0.9°, stability 0.1°C. Well depth<br />

120mm x 28Ømm. Comes with a multi-hole insert of<br />

3/2”,1/4”, 3/16” & 1/8” Ø holes. Light weight and portable.<br />

Jofra CTC-650A<br />

Temperature Calibrator<br />

JOF,CTC-650A<br />

MY<br />

Exceptionally fast and has deep immersion depths<br />

of 110mm (4.3 inch). Heats up to the maximum<br />

temperature in just 20 minutes. Temperature range: 33<br />

to 650°C. Accuracy: 0.9°C. Stability: 0.1°C. Multi-Hole<br />

insertion tube: 1/4”, 1/8”, 3/8” and 3/16”.<br />

Jofra CTC-1200A Temperature Calibrator<br />

JOF,CTC-1200A<br />

MY<br />

Compact temperature calibrator. Lightweight, portable for<br />

lab and general use. Temperature range: 572 to 2200ºF<br />

(300 to 1205ºC). Excellent Performance Characteristics.<br />

Accuracy: +/-4.0ºF (+/-2.0ºC). Stability: +1.0ºF (+0.5ºC).<br />

Stability Time: 20 minutes. Display in F or C to 0.1<br />

resolution. Fast cooling and heating. User-selectable<br />

Slope Rates for controlled. Thermo switch testing. Self<br />

Diagnostics includes Semi-Auto Switch Test and Hysteresis Test. Size of<br />

thermowell/insert: 6.5mm & 10mm. 1/4” probe. 1/2” probe.<br />

Rototherm C105 10,000psi<br />

Pressure Recorder<br />

ROT,C105<br />

MY<br />

Single pen recording. (±)1% span maximum. 1/2”(M)<br />

BSP connection. 255 mm diameter, circular chart paper.<br />

Yokogawa 3057-22 2 Pen Portable Recorder<br />

YEW,3057-22 (4011)<br />

AU<br />

Twelve input ranges 10mV to 50V fs, 150mm x 15m Z fold or roll chart, speeds<br />

20mm/h to 600mm/min. Accuracy 0.5%. Power 240/50Hz, rechargeable<br />

NiCad battery or 12VDC external.<br />

Yokogawa 3712-31 3 Pen Vertical Chart Recorder<br />

YEW,3712-31 (4004)<br />

AU<br />

Input ranges DC voltage 10mV to 200V fs. Thermocouples including type T &<br />

K. Chart speed 10mm/h to 20mm/s. Pen offset compensation. Memory card<br />

optional.<br />

Yokogawa 3712-41 4 Pen Vertical Chart Recorder<br />

YEW,3712-41 (4006)<br />

AU<br />

Input ranges: DC voltage 10mV to 200V fs. Thermocouples including type T &<br />

K. Chart speed 10mm/h to 20mm/s. Pen offset compensation. Memory card<br />

optional.<br />

Yokogawa 3750 10 Channel Multipoint Recorder<br />

YEW,3750 (4009)<br />

AU<br />

Ten channel hybrid recorder. Input ranges DC 20mV to 20V,<br />

thermocouple, RTD. Scans 10 channels in 2s. AC mains operation.<br />

Yokogawa DR130 Hybrid 20 Channel Recorder FDD<br />

YEW,DR130 (4010)<br />

AU<br />

Includes 3.5” FDD. Input unbalanced floating 20mV to 50VDC, TC, RTD and<br />

contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width 150mm.<br />

Data can be saved to 500k of internal RAM either directly or due to alarm<br />

conditions. The saved data can be copied to a 3.5” FDD file suitable for<br />

inclusion in standard spreadsheet programmes.<br />

High Speed Waveform Recorders<br />

Sandisk Compact Flash Card 512MB with PCMCIA Adaptor<br />

COM,FLASH512MB (4160)<br />

Compact Flash Card 512Mb type 1 with PCMCIA Adaptor.<br />

Hioki 8826 32 Channel Memory<br />

Recorder with all Isolated Inputs<br />

HIO,8826-32CRECORDER (4151) AU<br />

32 channel recorder with all isolated inputs.<br />

400V dc input range. Simultaneous sampling,<br />

display and recording of all 32 analogue and<br />

32 logic channels. Large capacity memory of<br />

max. 16M word Memory expandable four times (option). High resolution of<br />

12bit, 1M sampling/second. B4 size (paper width 264mm) wide printer. Highvisibility<br />

waveforms displayed on a 10.4” colour TFT liquid crystal display.<br />

Hioki 8835 4 Channel<br />

Waveform & 16 Channel<br />

Memory Recorder<br />

HIO,8835 (4116)<br />

AU<br />

Memory 12bits x 100k per<br />

channel or 500k for a single<br />

channel. Analogue input channel<br />

ranges 10mV to 50V/div, 10X div, 400VDC, 240VAC RMS max. Inbuilt<br />

FDD and type-III PC card slot. Fastest sampling rate 1MHz.<br />

Paper 110mm x 30m. Colour TFT display. Additional functions include<br />

waveform parameter calculation including RMS values, area value, rise and<br />

fall times. AC mains operation.<br />

AU<br />

50


www.techrentals.com.au<br />

General Industrial & Process Management<br />

High Speed Waveform Recorders<br />

cont’d.<br />

High Speed Waveform Recorders<br />

cont’d.<br />

Hioki 8835-01 4 Analogue,<br />

16 Logic Channel<br />

Waveform Recorder<br />

HIO,8835-01 (4128)<br />

AU<br />

Memory 12 bits x 1 megaword per<br />

channel or 4 megaword for a single<br />

channel. Analogue input channel ranges 10mV to 50V/div, 10X div, 400VDC,<br />

240VAC RMS max. In-built FDD & type-III PC card slot. Fastest sampling rate<br />

1MHz. Paper 110mm x 30m. Colour TFT display. Additional functions include<br />

waveform parameter calculation including RMS values, area value, rise and<br />

fall times. AC mains operation. Logic probes must be rented separately.<br />

Hioki 8835-HD520 520Mb PCMCIA Hard Disk for HIO,8835 & 8841<br />

HIO,8835-HD520 (4122)<br />

AU<br />

PCMCIA interface complete with 520Mb card. Data can be stored in several<br />

formats: as a binary memory file for replay on the recorder; as a CSV text file<br />

compatible with Excel; as a BMP screen dump for a Word document, etc; as<br />

a single or dual FFT binary file for replay on the recorder. The recorder setup<br />

can be saved for future applications requiring the same settings. Data media<br />

is PCMCIA Type III compatible with many laptop computers.<br />

Hioki 8841 8 Analogue, 16<br />

Channel Memory Recorder<br />

HIO,8841 (4117)<br />

AU<br />

Memory 12bits x 4 megawords/ch<br />

for 2 analogue ch, to 1 megawords/<br />

ch for 8ch. In-built FDD, type III<br />

PCMCIA card slot (for flashcard<br />

& HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory,<br />

real time record, RMS, real time/memory, X-Y memory, FFT. Trigger<br />

functions level, window in, window out, voltage drop, RMS level,<br />

cycle, logic pattern trigger 1,0 or X (disregard). When using logic channels,<br />

logic probes must be rented separately. Measurement range 400VDC, 240V<br />

RMS, low pass filters 5Hz, 500Hz, 5kHz or 100kHz, input coupling DC, GND,<br />

AC. Large 10.4” colour TFT display for settings and waveform display, wide<br />

thermal printer fitted. On screen help function. All settings and waveforms<br />

can be saved to media, waveforms can be saved as binary, text or bmp files.<br />

Hioki 8842 16 Analogue, 16<br />

Logic Channel Waveform<br />

Recorder<br />

HIO,8842 (4150)<br />

AU<br />

Memory 12bits x 16 megawords/ch for<br />

2 analogue ch, to 2 megawords/ch for<br />

16 ch. Analogue input channel ranges<br />

10mV to 50V per div, 10X div, 400VDC, 240VAC RMS max. In-built FDD,<br />

type III PCMCIA card slot (for flashcard & HDD up to 520Mb). Sampling rate<br />

of 1MHz max. Functions memory, real time record, RMS, real time/memory,<br />

X-Y memory. Trigger functions level, window in, window out, voltage drop,<br />

RMS level, cycle, logic pattern trigger 1,0 or X (disregard). When using logic<br />

channels, logic probes must be rented separately. Measurement range<br />

400VDC, 240V RMS, low pass filters 5Hz, 500Hz, 5kHz, or 100kHz, input<br />

coupling DC, GND, AC. Large 10.4” colour TFT display for settings and<br />

waveform display, wide thermal printer fitted. On screen help function. All<br />

settings and waveforms can be saved to media, waveforms can be saved as<br />

binary, text or bmp files.<br />

Hioki 8860 8 Channel High Speed<br />

Memory Recorder<br />

HIO,8860 (4129)<br />

AU<br />

High speed memory recorder, 20MS/s sampling<br />

rate, 8 analogue channels, 16 logic channels,<br />

built in printer. 512MW or direct access memory,<br />

60GB hard drive built-in, PC card type II slot<br />

up to 4GB ATA flash card (optional) USB, LAN<br />

interface and large colour screen.<br />

Hioki 8870-20 Memory Hicorder 2<br />

Analogue & 4 Logic Channels<br />

HIO,8870-20 (4101)<br />

AU<br />

Channels; 2 analogue and 4 logic (standard<br />

equipment, logic grounds are common<br />

with instrument ground), 10mV to 50V/<br />

div, 12 ranges, resolution: 1/100 of range,<br />

DC 400V, DC to 50kHz (-3dB). 100μs/<br />

div to 5 min/div, 20 ranges, at 100 points/<br />

div resolution, three steps of time-axis magnification from 2× to 10×, and<br />

nine steps of time-axis compression from 0.5× to 0.001. MEM (high-speed<br />

recording), 12bits × 2M-Words/ch, CF Card Type I slot × 1, up to 1GB. Display<br />

4.3-inch WQVGA-TFT colour LCD (480 × 272 dots). One USB 2 high speed<br />

mini-B receptacle: transfers files from the installed CF card to a PC when<br />

connected. Numerical calculation, cursor readout, scaling function, screen<br />

copy, gauge display, waveform data/setting configurations backup, start<br />

condition retention, auto-save, instantaneous value or RMS value display<br />

(only DC and 50/60Hz). Use with the AC adapter, 100 to 240VAC (50/60Hz)<br />

30VA max. Battery pack; continuous use 2h (AC adapter has priority when<br />

both are used). 12VDC supply: 10 to 16V, 10VA Max.<br />

Hioki 8938 FFT Input Signal<br />

Module<br />

HIO,8938 (4138)<br />

AU<br />

FFT Module with anti-aliasing filter.<br />

Frequency range DC to 400kHz,<br />

sampling rate 1MS/s. Maximum input<br />

voltage 400VDC, 240V RMS.<br />

Hioki 9305 Trigger Cord for Hioki Memory Recorders<br />

HIO,9305 (4135)<br />

AU<br />

Plug each end of cable 3.5mm. Trigger cord enables master slaving of the Hioki<br />

8835, 8810 and 8811 memory recorders. One end connected to the trigger<br />

output socket of master recorder the other end connects to the trigger input<br />

socket of the second recorder which is the slave. Trigger pattern set up for the<br />

master and the slave recorder set just to external trigger.<br />

Hioki 9306 4 Channel Contact & Digital Logic Probe<br />

HIO,9306 (4123)<br />

AU<br />

Contact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842 memory<br />

recorders. Threshold digital >1.4V maximum input 50V. Contact closure input,<br />

2k input resistance 30V allowable input. Response time 2μs.<br />

Hioki 9320 4 Channel Contact &<br />

Digital Logic Probe<br />

HIO,9320 (4140)<br />

AU<br />

For HIO, 8811, 8835, 8835-01, 8841 &<br />

8842 memory recorders, 4 channels<br />

per probe, max of 4 probes per<br />

recorder. Threshold digital selectable<br />

1.4V, 2.5V & 4V. Response time 500ns<br />

max. Relay dry contact detection. Max<br />

allowable input 50VDC.<br />

Hioki 9321 Line Logic Probe<br />

HIO,9321 (4124)<br />

AU<br />

Four channels (insulated) per probe.<br />

Detection of 60 to 150VAC, 170 to<br />

250VAC, 20 to 150VDC & 70 to 250VDC<br />

in 2 ranges. Response time slope rise<br />

1ms, fall 3ms. Max input low range<br />

150V RMS, high range 250V RMS.<br />

Max rated voltage to earth 250V RMS.<br />

Connector cable 1.5m. Probe tip cable 1m.<br />

51


General Industrial & Process Management<br />

www.techrentals.com.au<br />

High Speed Waveform Recorders<br />

cont’d.<br />

Hioki 9335 Wave Processor Software for Hioki 8835, 8835-01, 8841, 8842<br />

HIO,9335 (4155)<br />

AU<br />

Waveform Processor software, displays, converts to CSV, calculates and<br />

prints waveforms with a PC. Review stored binary files from Hioki 8835,<br />

8835-01, 8841 and 8842 memory recorders. Only way stored binary files can<br />

be viewed on a PC without having to re save them with memory recorder as<br />

text files.<br />

Hioki 9725 Memory Viewer Software<br />

HIO,9725 (4157)<br />

AU<br />

Data processing software for Hioki 8860 High Speed Memory Recorder.<br />

Functions: file loading, maximum loadable data size 2GW file saving,<br />

measurement of data binary, partial saving between A/B cursors is<br />

possible. Screen images BMP and PNG, calculation results. Display of<br />

saved binary files, displayable channels per sheet analogue 32, logic 16<br />

channels. Displayable sheets 16.<br />

Data Loggers<br />

Compact Flash card 64MB with PCMCIA adaptor<br />

COM,FLASH64MB (4239)<br />

64MB Compact Flash card with PCMCIA card adaptor.<br />

AU/MY<br />

Datataker CANGATE Gateway &<br />

Garmin 5Hz GPS<br />

DE,CANGATE (4236)<br />

AU<br />

Interface to allow dataTaker loggers and PC<br />

(via RS232) to access CANBUS networks<br />

including J1939 & OBD2. The device also<br />

includes a Garmin 5Hz GPS system.<br />

DataTaker DT600 Data Logger<br />

DE,DT600<br />

MY<br />

Includes LCD display enabling use as a measuring instrument if<br />

pre-programmed for channel parameters. 10 differential or 30 single-ended<br />

channels. 25 channel/sec. 4 TTL/CMOS digital inputs. 3 counter channels up<br />

to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LEDs. Internal<br />

memory for up to 13,000 data points with optional memory card to 170,000<br />

readings. RS-232C data communications port and RS-485 port for networking<br />

up to 32 loggers. Maths processing included. Input ranges 25mV to 2.5VDC.<br />

Maximum sensitivity 2μV. Current 0.25 to 25ma. Current loop 4-20mA.<br />

Resistance up to 7,000 ohms. Thermocouples types B,C,D,E,G,J,K,N,R,S, &<br />

T from -250 to 1800ºC. Thermistors and RTD’s. Strain gauges. Supplied with<br />

determinal & decipher plus software. Operates from internal battery, external<br />

battery, or ac mains.<br />

DataTaker DT80 5 to 15 Channel Logger<br />

with USB Memory Stick <strong>Download</strong><br />

DE,DT80 (4232)<br />

AU<br />

Measures voltage, current, resistance and frequency. Up to 15 analogue<br />

(±30V) sensor inputs. Each channel is independent and supports: one<br />

isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common<br />

referenced 2-wire inputs. 12 flexible digital channels. Expandable to 300<br />

analogue inputs. Store up to 10 million data points in user defined memory.<br />

DataTaker DT80M 5 to 15 Channel<br />

Logger with Built in Modem<br />

DE,DT80M (4234)<br />

AU<br />

Includes a built in GSM modem for internet<br />

access to the device. Measures voltage, current,<br />

resistance and frequency. Up to 5 analogue<br />

(±30V) sensor inputs. Each channel is independent and supports: one<br />

isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common<br />

referenced 2-wire inputs. Store up to 10 million data points in user defined<br />

memory.<br />

52<br />

Data Loggers cont’d.<br />

DataTaker DT800 Data<br />

Logger<br />

DE,DT800 (4231) AU/MY<br />

Universal input channels 12 balanced or 42<br />

unbalanced analogue channels. Eight bidirectional<br />

digital channels and 8 digital input<br />

channels. Solid state multiplexer protected to ±40V. Max in/out voltage<br />

±12V. Serial sensor channel can be used with GPS systems. Measures V,<br />

4 to 20mA, strain, TC, RTD etc. Sampling rate 200Hz up to 100kHz in burst<br />

mode. Instrument has RS232, RS422, USB, Ethernet (10baseT) & PC card<br />

modem communications. Pluggable 64Mb memory card stores up to 300,000<br />

(compressed) readings per Mb. Instrument stores 600,000 (compressed)<br />

readings in internal memory. Total memory capacity 10.2Mb (compressed).<br />

Datataker DT85 48 Channel<br />

Logger with USB Memory<br />

Stick <strong>Download</strong><br />

DE,DT85 (4233)<br />

AU<br />

Analogue inputs 32 isolated and 48 single<br />

ended inputs. 2 x 4 digital input types. 2 x serial sensor ports, Modbus<br />

capability, 4 x SDI12 channels, USB memory stick interface for easy data and<br />

programming etc. Operating time on the internal battery is 1s sample 2.4h. 5s<br />

sample 3 days, 1min sample 1 month.<br />

ETM 9900 Intelligent Modem and IO. Sends<br />

SMS Messages<br />

ETM,9900 (4290)<br />

AU<br />

Can send a user defined alarm message via SMS.<br />

Has 7 IO channels. Will provide alarm messages<br />

for instruments such as the ARL,NGARA,<br />

PRO,VIBRA & the TSI,8520 & 30. Will operate for around 4 months on 2xD<br />

cell batteries when the alarm status is checked once per hour. Can be put on<br />

site and remotely programmed.<br />

Fourier DAQPRO8 Battery Operated Hand Held 8<br />

Channel Data Logger<br />

FOU,DAQPRO-2 (4282)<br />

AU<br />

Portable, hand held, battery operated 8 channel data logger. 16-bit<br />

resolution, built in graphic LCD, for setting up, graphical display of logged data.<br />

PC communications via USB interface. Signal inputs 0 to 24mA, 0 to 50mV,<br />

0 to 10V. Temperature input via NTC 10kΩ, 100kΩ, range -25 to 150ºC, PT100<br />

range -200 to 400ºC, T/C ranges J type, -300 to 1500ºC, K type -250 to 1100ºC,<br />

T type -200 to 400ºC. Frequency input one channel only, 20 to 4,000Hz,<br />

sensitivity 20mV, pulse counter one input 0 to 65,000 counts. Memory<br />

capacity 512KB, sampling rates from 1s/h to 4,000s/s. Supplied with analysis<br />

and setting up software.<br />

Fourier Microlog Temp/Hum Logger Kit with Wireless Cradles<br />

FOU,MICROLOG-KIT (4263)<br />

AU<br />

Set of 5 temperature and humidity loggers mounted in RF<br />

transmitter cradles, one receiver for PC. Transmission range up to 300m<br />

or RS232C & USB interface also included if direct connection to PC for<br />

down loading required. Temperature range -30 to 50ºC, accuracy ±1º, 0 to<br />

100%RH accuracy ±3%RH, 2 digit LCD, memory capacity 16,000 data points<br />

between 2 channels. User defined sampling rate from 10s to 2h. MicroLog Plus<br />

management control software included to control and monitor all the loggers<br />

remotely on PC within transmission range.<br />

Hioki 3641-20-Kit Temperature & Humidity Logger<br />

HIO,3641-20<br />

MY<br />

Temperature and humidity logger includes: 1 x RS232C and 1 x USB<br />

communication base, utility software,RS232C and USB interface cables.<br />

Environment conditions for operation -20 to 70ºC, 80%RH (no condensation).<br />

Accuracy: temperature -40 to -0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC, 35.1 to 70ºC<br />

±1ºC. Humidity typical between ±5 to ±10% depends on temperature<br />

and humidity range. 8000 data points x 2 channels, recording interval<br />

2,5,10,15,20,30s and 1,2,5,10,15 ,20,30,60min.


www.techrentals.com.au<br />

General Industrial & Process Management<br />

Data Loggers cont’d.<br />

Data Loggers cont’d.<br />

Hioki 3641-20-Kit of 8 Temperature & Humidity<br />

Loggers<br />

HIO,3641-20-KIT (4256)<br />

AU<br />

Kit of 8 x temperature and humidity loggers. Includes<br />

1 x RS232C and 1 x USB communication base,<br />

utility software, RS232C and USB interface cables.<br />

Environment conditions for operation -20 to 70ºC,<br />

80%RH (no condensation) Accuracy: Temperature -40 to<br />

-0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC, 35.1 to 70ºC ±1ºC. Humidity typical between<br />

±5 to ±10% depends on temperature and humidity range. 8000 data points x<br />

2 channels, recording interval 2,5,10,15,20,30s and 1,2,5,10,15 ,20,30,60min.<br />

Hioki 8421-01 16 Channel Data Logger with Colour Display<br />

HIO,8421-01 (4270)<br />

AU<br />

16 analogue, 4 pulse input channels data logger with colour<br />

display, PCMCIA card slot, LAN interface built in, TCP/IP communication<br />

supports real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVDC,<br />

1VDC, 10VDC, 60VDC, 1 to 5VDC fs. Thermocouples K,E, J, T, N, W (WRe5<br />

to 26) R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100<br />

-200 to 800ºC. Pulse input, accumulation 50,000 counts fs, 500,000 counts<br />

fs, 5M counts fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s)<br />

fs. Recording interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20,<br />

30s, 1, 2 & 5min. Max sampling rate is dependent upon type of input signal.<br />

Internal Memory 8Mb, 256Mb Flashcard, 9334 logger communicator<br />

software, 9642 LAN cable, 9641 pulse signal input cable all supplied.<br />

Hioki 8421-51 16 Channel Data Logger with Colour Display<br />

HIO,8421-51 (4271)<br />

AU<br />

16 analogue, 4 pulse input channels data logger with colour display, PCM-<br />

CIA card slot, LAN interface built in, TCP/IP communication supports real<br />

time PC logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1VDC,<br />

10 VDC, 60VDC, 1-5VDC f.s. Thermocouples K, E, J, T, N, W (WRe5-26),<br />

R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100 -200<br />

to 800ºC. Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s,<br />

100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval<br />

selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min,<br />

2min, 5min. Max sampling rate is dependent upon type of input signal.<br />

Internal Memory 16MW, 512MB PCMCIA FLASH card, 9334 Logger<br />

Communicator software, 9642 LAN cable, 9641 pulse signal input<br />

cable all supplied. Improved common mode rejection -100dB or better<br />

when 50/60Hz, 140dB or better when 50Hz, using ch1 to ch16, interval 5s,<br />

digital filter 50Hz selected. Faster sampling when using Pt100, improved<br />

temperature characteristics.<br />

Hioki 8422-51 32 Channel Data Logger<br />

HIO,8422-51 (4273)<br />

AU<br />

32 analogue, 4 pulse input channels data logger with colour display, PCMCIA<br />

card slot, LAN interface built in, TCP/IP communication supports real time PC<br />

logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1 VDC, 10 VDC, 60<br />

VDC, 1-5V DC f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, B, -100 to<br />

100ºC, -200 to 500ºC, -200 to 2,000ºC, Pulse input, accumulation 50,000C<br />

f.s, 500,000C f.s, 5MC f.s, 100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s)<br />

f.s. Recording interval is selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s,<br />

10s, 20s, 30s, 1min, 2min, 5min. Max sampling rate is dependent upon type<br />

of input signal. Internal Memory 8MB, 512MB PCMCIA FLASH card, 9334<br />

Logger Communicator software, 9642 LAN cable, 9641 pulse signal input<br />

cable all supplied.<br />

Hioki Kit of Three 9322 Differential Probe High Voltage<br />

True RMS Interface<br />

HIO,9322-KIT (4119)<br />

AU<br />

Used with many memory recorders, eg. Hioki 8835. Operating modes 3.<br />

DC mode for waveform monitor output DC to 3MHz, AC mode detection of<br />

power surge noise 1kHz to 10MHz. Rectified true RMS output of DC & AC<br />

voltages. 40Hz to 100kHz response speed 200ms or less. Max voltage DC<br />

2kV, AC 1kV CATII, AC/DC 600V CATIII, balanced differential input 1/1,000<br />

divider.<br />

Testo 175-H1 Temperature<br />

& Humidity Logger<br />

TES,175-H1 (4251)<br />

AU<br />

Large display. 3 year battery life, 1 million sample memory. RH<br />

0 ~100% ±2%, temperature -20~50ºC ±-0.4ºC . Includes USB<br />

interface to download data<br />

Testo 177-H1 Logger with Display<br />

TES,177-H1<br />

MY<br />

Parameters: humidity/temperature/dew point. Sensors: humidity sensor/<br />

NTC (internal). Number of channels: 4. Measuring range: 0 to 100%RH and<br />

-20 to 70ºC (internal). Memory: 48,000 readings.<br />

Testo 177-T4 Logger with Display<br />

TES,177-T4<br />

MY<br />

Parameters: temperature (C/F). Sensors: thermocouple type-K. Number<br />

of channels: 4 (external). Measuring range: -100 to 1,000 ºC (external).<br />

Memory: 48,000 readings.<br />

See also Air Conditioning & Air Flow on page 62-63<br />

Pressure & Humidity Transducers<br />

Druck PTX1400 4Bar Pressure Transducer<br />

DRU,PTX1400-4 (4307)<br />

AU<br />

Output 4 to 20mA. Requires 9 to 36VDC. Supplied with 12V<br />

plug pack. Pressure input connector G ¼” female.<br />

Druck PTX1400-25 25Bar Pressure Transducer 4 to 20mA<br />

DRU,PTX1400-25 (4302)<br />

AU<br />

Output 4 to 20mA output, 0 to 25Bar input. Requires 9 to 28VDC, supplied<br />

with 12V, 500mA power pack.<br />

Druck PTX 1400 600Bar Pressure Transducer<br />

DRU,PTX1400-600 (4305)<br />

Output 4 to 20mA. Requires 9 to 32VDC, supplied with 12V plug pack.<br />

Fluke PV350 Vacuum/Pressure Indicator<br />

FLU,PV350 (4321)<br />

AU<br />

Can be used with a digital multimeter to act as an<br />

indicator. Range, pressure to 4137kPa and vacuum 0 to<br />

76cmHg. Results in either psi or kPa. Connector 1/2”NPT<br />

(m). Cable 2.4m provided. Battery powered.<br />

Pressure Vacuum Gauges/Recorders<br />

Crystal XP2i Digital Logging<br />

Pressure Gauge 7Bar NATA calibrated<br />

CRY,XP2I-100-NATA (4341)<br />

AU<br />

Range 7Bar resolution 0.1mBar. Accuracy 1.4 to 7Bar<br />

±0.1% of reading. 0 to 1.4Bar ±1.4mBar. Vacuum<br />

±17.5mBar. Has a 6000 point logging capability. Logging<br />

intervals from 1s up can be set. Logs either actual<br />

pressure, average pressure or average pressure with max<br />

and min. Also logs on demand. ¼″ NPT connector.<br />

Crystal XP2i Digital Logging<br />

Pressure Gauge 20Bar NATA calibrated<br />

CRY,XP2I-300-NATA (4341)<br />

AU<br />

Range 20Bar resolution 1mBar. Accuracy 4 to 20Bar<br />

±0.1% of reading. 0 to 4Bar ±4mBar. It Has a 6000 point<br />

logging capability. Logging intervals from 1s up can be set.<br />

Logs either actual pressure, average pressure or average<br />

pressure with max and min. Also logs on demand.<br />

AU<br />

53


General Industrial & Process Management<br />

www.techrentals.com.au<br />

Pressure Vacuum Gauges/Recorders<br />

cont’d.<br />

Crystal XP2i Digital Logging Pressure Gauge 70Bar NATA calibrated<br />

CRY,XP2I-1K-NATA (4342)<br />

AU<br />

Range 70Bar resolution 0.001Bar. Accuracy 14 to 70Bar ±0.1% of Reading<br />

0 to 14Bar ±14mBar. Has a 6000 point logging capability. Logging intervals<br />

from 1s up can be set. Logs either actual pressure, average pressure or<br />

average pressure with max and min. Logs on demand. ¼″ NPT connector.<br />

Crystal XP2i Digital Logging Pressure Gauge 210Bar NATA calibrated<br />

CRY,XP2I-3K-NATA (4343)<br />

AU<br />

CRY,XP2I-3K<br />

MY<br />

Range 210Bar resolution 0.01Bar. Accuracy 40 to 200Bar ±0.1% of reading. 0<br />

to 40Bar ±0.04Bar. Has a 6000 point logging capability. Logging intervals from<br />

1s up can be set. Logs either actual pressure, average pressure or average<br />

pressure with max and min. Also logs on demand. ¼″ NPT connector.<br />

Crystal XP2i Digital Logging Pressure Gauge 700Bar NATA calibrated<br />

CRY,XP2I-10K-NATA (4344)<br />

AU<br />

Range 700Bar resolution. 0.01Bar accuracy. 1% of reading. Has logging<br />

capability. 6000 point pressure logging capability. Logging interval can be<br />

set from 1s up. Logs either Actual Pressure, Average Pressure, or Average<br />

pressure with Max & Min or log on demand. NATA Calibrated. ¼″ NPT<br />

connector.<br />

Flow Meters for Liquids & Gases<br />

See also Environmental Flow Meters on page 74<br />

Flexim Ultrasonic Gas Flow<br />

Meter<br />

FLE,G608 (6156)<br />

AU<br />

Ultrasonic flow meter is a clamp-on transit time gas<br />

and liquid flow meter, 2-channel, with Zone 2 Excertification<br />

for use in hazardous areas. Supplied with<br />

three transducer pairs and a pipe wall thickness gauge;<br />

includes an integral data-logger with more than 100,000<br />

measured values, easy-to-use software for trending the data and an integral<br />

Lithium-ion rechargeable battery with AC adapter. The GLK transducers are<br />

suitable for 4 to 9mm wall thickness, the GLM 2 to 5mm and the GSM 2.5mm<br />

and greater. Utilises either Shear wave (standard) transducers, or Lamb<br />

wave (specialist gas) transduOLYcers. The Lamb wave transducers resonate<br />

the pipe wall to amplify the signal strength, thereby allowing it to measure<br />

applications at significantly lower pressures than the standard Shear wave<br />

transducers.<br />

GE Panametrics PT878GC Ultrasonic Gas Flow Meter<br />

PAN,PT878GC-01 (6151)<br />

AU<br />

Portable non-contact gas flowmeter using transit-time principle. For<br />

operation with ultrasonic transducer-kits (PAN,GC-RL302 & PAN,GC-<br />

RL319) - available separately. Compatible with metal or plastic pipes in the<br />

range 20 to 300mm. Suitable for use with compressed air, natural gas and<br />

other gases. Readout for flow velocity, actual or standard volumetric flow or<br />

mass-flow in numerical or graphic format. Internal logging for 100K flow data<br />

points. Infrared communications port for download to PC or printer interface.<br />

Rechargeable battery for 8h continuous operation.<br />

Gas-flow Small Pipe Transducer Kit for PT878GC<br />

PAN,GC-RL302 (6153)<br />

AU<br />

Advanced clamp-on ultrasonic transducer pair for use with Panametrics gas<br />

flowmeters. Operation at 1MHz for pipes in the range 20 to 55mm typical.<br />

General purpose use for process temperatures -40 to 176°C. Supplied with<br />

two precision gauged clamping fixtures for pipe range.<br />

Flow Meters for Liquids & Gases<br />

cont’d.<br />

Gas-flow Medium Pipe Transducer Kit for PT878GC<br />

PAN,GC-RL319 (6155)<br />

AU<br />

Advanced clamp-on ultrasonic transducer pair for use with Panametrics gas<br />

flowmeters. Operation at 500kHz for pipes in the range 75-300mm typical.<br />

General purpose use for process temperatures -40 to 176°C. Supplied with<br />

set of three precision gauged clamping fixtures for pipe range.<br />

GE Panametrics<br />

PT878 Ultrasonic<br />

Flowmeter<br />

PAN,PT878 (6101)<br />

AU/MY<br />

Portable non-contact liquid flowmeter<br />

using transit-time principle. Includes<br />

transducers for pipe 50mm to 2mØ &<br />

temperatures -40 to 130°C (various<br />

alternative transducers available) with<br />

clamping fixture. Flow velocity range<br />

0.03 to 12.2m/s. Accuracy typically 1%.<br />

Data logging for over 100K data points. Analogue inputs compatible with<br />

temperature transmitters for energy-flow calculations. Outputs analogue 4<br />

to 20mA, digital (pulse or frequency) and printer/computer (Infrared port).<br />

Large LCD display for velocity, volumetric and energy flow rate, totalised flow<br />

and trend data in alphanumeric and graphical formats. Rechargeable NiMH<br />

batteries and AC power supply/charger.<br />

See also GLO,FP101 Global FP101 Digital Water Velocity Meter<br />

on page 74<br />

Panametrics PT878E Ultrasonic Liquid Flow Energy Meter<br />

PAN,PT878E (6102)<br />

AU<br />

Portable non-contact liquid flowmeter using transit-time principle.<br />

Includes transducers to measure energy and transducers for pipe 50mm to<br />

2mØ & temperatures -10 to 130°C (various alternative transducers available)<br />

with clamping fixture. Flow velocity range 0.03 to 12.2m/s. Accuracy typically<br />

1%. Data logging for over 100K data points. Outputs analogue 4 to 20mA,<br />

digital (pulse or frequency) and printer/computer (Infrared port). Large LCD<br />

display for velocity, volumetric and energy flow rate, totalised flow and trend<br />

data in alphanumeric and graphical formats. Rechargeable NiMH batteries<br />

and AC power supply/charger.<br />

GE Panametrics PT878 Ultrasonic Liquid Flow Meter<br />

PAN,PT878T (6103)<br />

AU<br />

Portable non-contact liquid flowmeter using transit-time<br />

principle. Includes thickness gauge and transducers for pipe 50mm to<br />

2mØ & temperatures -40 to 130 degC (various alternative transducers<br />

available) with clamping fixture. Flow velocity range 0.03 to 12.2m/s.<br />

Accuracy typically 1%. Data logging for over 100K data points. Analog<br />

inputs compatible with temperature transmitters for energy-flow<br />

calculations. Outputs analog 4 to 20mA, digital (pulse or frequency) and<br />

printer/computer (Infrared port). Large LCD display for velocity, volumetric<br />

and energy flow rate, totalised flow and trend data in alphanumeric and<br />

graphical formats. Rechargeable NiMH batteries and AC power supply/<br />

charger.<br />

GE Panametrics 12 to 50mm Transducers<br />

PAN,C-LP-40NM (6108)<br />

AU//MY<br />

Transducer pair for PAN,PT868/878 transit-time flowmeter to suit pipe 12 to<br />

50mmØ. Complete with CF-LP-50M mounting bracket. Temperature range<br />

-40 to 120°C.<br />

GE Panametrics -20 to 210°C Transducers<br />

PAN,C-PT-10HB (6110)<br />

AU<br />

High temperature transducer pair for PAN,PT868/878 transit-time flowmeter.<br />

Operates on pipe sizes 50mm~2m diameter. Working temperature range<br />

-40~230°C.<br />

54


www.techrentals.com.au<br />

General Industrial & Process Management<br />

Flow Meters for Liquids & Gases<br />

cont’d.<br />

Combustion, Flue & Industrial<br />

Gas Analysers cont’d.<br />

GE Panametrics -200 to 400°C Transducers<br />

PAN,OKS (6112)<br />

AU<br />

Very high temperature, wide range transducer pair for PAN,PT868/878<br />

transit-time flowmeter. Temperature range -200 to 400°C, for pipe 80mm to<br />

600mmØ. Uses special clamp system supplied. Appropriate protection and<br />

safe-handling equipment is required for fitting and operation at very high or<br />

low temperatures.<br />

Polysonics Hydra SX30 Dual<br />

Frequency Doppler Liquid Flowmeter<br />

POL,HYDRA-SX30-2 (6132)<br />

AU<br />

Dual frequency doppler ultrasonic non-contact<br />

flowmeter. Velocity range 0.06 to 10m/s, accuracy<br />

±1%. Pipe size range 12 to 5,000mm diameter. Data<br />

logging for 90,000 points, with PC software and<br />

interface cable for download via RS232C interface.<br />

Transducer temperature range -40 to 122°C.<br />

Analogue output 4 to 20mA. Battery operated, 12h<br />

continuous use (8h recharge).<br />

Combustion, Flue & Industrial<br />

Gas Analysers<br />

See also Environmental Gas & Vapour Meters on page 67-68<br />

Novatech O 2<br />

and CO 2<br />

Analyser/Transmitter<br />

NOV,1637-5 (5954)<br />

AU<br />

Oxygen and carbon dioxide analyser for packaging<br />

atmosphere, general industrial and research use.<br />

Oxygen sensor reading 1ppm to 100% with 1%<br />

accuracy. NDIR carbon dioxide analysis 0 to 100%<br />

±3% of full scale. 2 x 4 to 20mA outputs, 1 common<br />

& 3 selectable alarm relays. Gas connection 1/8 Swagelok. Flow rate with<br />

internal pump 100 to 500cc/min. AC operation.<br />

Testo 300M Combustion Gas<br />

Analyser<br />

TES,300M<br />

MY<br />

Flue gas analyser for combustion efficiency<br />

measurement. Temperature range -40 to 1200°C<br />

±0.5 (100) with gas probe<br />

operation to 1,000°C max. Draught/pressure<br />

range 80mBar, ±0.03. Gases measured: O 2<br />

0 to<br />

21%, ±0.2%; CO 2<br />

[calculated] 0 to CO 2<br />

max vol ±0.2%; CO 0 to 8,000ppm,<br />

±20 (


Two way radio equipment can<br />

be a long term investment.<br />

hirecom<br />

Why buy your radios - there is a better way.<br />

WHY RENT?<br />

PURCHASE<br />

RENTAL<br />

Immediate replacements for faulty<br />

or damaged equipment <br />

Radio repairs covered <br />

Battery replacements covered <br />

Frequency management <br />

Upgrade path <br />

Tax advantages # <br />

Capital preservation <br />

WHY WOULD YOU NOT?<br />

THINK RENTAL<br />

hirecom<br />

Call TR Hirecom today on 1800 222 327<br />

to discuss your two way radio communication needs.<br />

www.trhirecom.com.au<br />

BR0157<br />

#<br />

Please ensure you obtain independent professional taxation advice. 56


www.techrentals.com.au<br />

Physical Measurement<br />

Material Hardness Testers<br />

Non-Destructive Testing<br />

Micrometers<br />

Position Transducers<br />

Inclinometers<br />

Force Gauges<br />

Load Cells<br />

Weighing & Counting Scales over 8kg<br />

Vibration Analysis<br />

Speed Measurement<br />

Material Hardness Testers<br />

Krautkramer DynaPocket<br />

Rebound Hardness Tester<br />

KRA,DYNAPOCKET (4932) AU<br />

Based on the Leeb’s method HL,<br />

utilising a 3mm tungsten carbide<br />

ball. Other hardness scales can<br />

be selected, HS Shore, HB Brinell, HRB Rockwell B, HRC Rockwell C, HV<br />

Vickers and N/mm 2 tensile strength. Choice of 9 material groups can be<br />

selected, they are St Low-alloy/unalloyed steel and cast steel, ASt Tool steel,<br />

SSt Corrosion resistant steel, GCI Gray cast iron, NCI Nodular graphite cast iron,<br />

AL Aluminium cast alloys, brS Brass, brZ Bronze, Cu Wrought copper alloys.<br />

Proceq Equotip Hardness Tester<br />

PRO,EQUOTIP (4931)<br />

AU<br />

Test probe on a flexible lead. Probe type D is<br />

standard catering for most materials. Measurement<br />

ranges steels 80 to 650HB, 80 to 940HV, 20 to<br />

68HRC, aluminium castings 20 to 160HB, cast iron<br />

90 to 380HB, brass 40 to 170HB & copper wrought alloys 43 to 315HB. Test<br />

hardness must not exceed 940HV. Battery operated.<br />

Non-Destructive Testing<br />

Defelsko FNS2 Ferrous & Non Ferrous Coating<br />

Thickness Tester<br />

DEF,FNS2 (4802)<br />

AU<br />

Storage of up to 250 readings. Supplied with external probe,<br />

calibration standards and carry pouch. Measurement<br />

range 0 to 1500μm or 0 to 60mils (selectable), tolerance<br />

0 to 50mm ±1mm, +1% of reading, greater than 50mm<br />

±2μm, +1%, resolution 0.1mm. Back glow display, HiLo<br />

limits audible and visible alerts when measurements exceed specified limits.<br />

Continually displays updates average, standard deviation, min/max thickness<br />

and number of readings while measuring. Hi resolution mode for greater<br />

precision. Built in infra red port for down loading data.<br />

PosiTector 200 B & C Ultrasonic<br />

Coating Thickness Gauge<br />

DEF,POS-200ADV (4805)<br />

AU<br />

Ultrasonic coating thickness gauge with type B & C Probes.<br />

Measures coating thickness over wood, concrete, plastics,<br />

composites etc. Will measure up to 3 individual layer thickness<br />

in a multi-layer system and features a graphic readout.<br />

Supplied with both B, 13 to 1000μm for wood, plastic and<br />

composites and C probes 50 to 3800μm for coatings on<br />

concrete, fibreglass etc. Accuracy is ±2um +3% of reading.<br />

Non-Destructive Testing cont’d.<br />

Defelsko Positest Pull Off Adhesion Tester for Concrete & Metal<br />

DEF,POSITEST (4817)<br />

AU<br />

Measures the force required to pull a specified test diameter of coating away<br />

from its substrate using hydraulic pressure. Pressure is displayed in both MPa<br />

and PSI on a precision dial indicator and can be related to the strength of<br />

adhesion to the substrate. Suitable for coatings on both metal and concrete<br />

surfaces. Conforms with standards ASTM D4541 and ISO 4624.<br />

Mitutoyo SJ-201 Surface Roughness<br />

Tester<br />

MIT,SJ201-NATA (4906)<br />

AU<br />

Comprises LCD display and a detachable<br />

detector/drive unit. Parameters measured in<br />

Ra, Rq, Ry, Rz, Rt, Rp, R3z, Rk, Rpk, Rvk,<br />

S, Sm, Pc, mr, Mr1, Mr2, A1, A2, Vo units. Ranges: 350, 100, 50μm & 10μm,<br />

resolution from 0.01 to 0.4μm. Tip radius 5mm. Data output. NiCd batteries.<br />

Olympus Epoch 600 Flaw<br />

Detector<br />

OLY,EPOCH600 (4900)<br />

AU<br />

General purpose ultasonic flaw detector. Includes UT<br />

angle beam transducers 45, 60 & 70º, and Atlas dual<br />

element transducer. Stores images and data to micro<br />

SD card.<br />

Olympus Ultrasonic Thickness Gauge<br />

OLY,38DL (4905)<br />

AU<br />

Operates with dual and single element transducers,<br />

has colour transflective VGA screen. Includes<br />

datalogging capability. Does echo to echo<br />

measurements. Supplied with transducers to<br />

measure steel, cast, corroded steel, rubber, fibreglass<br />

and composites. Includes D7906-SM, M1036, M2008<br />

M109-RM (inc delay line M202-RM) transducers.<br />

Olympus 26mg Pocket Thickness Gauge<br />

PAN,26MG (4910)<br />

AU/MY<br />

Range 1 to 500mm, fast min mode. Resolution 0.01mm. Probe operates -20<br />

to 150ºC.<br />

Olympus Ultrasonic Probe for<br />

OLY,38DL & PAN,26MG<br />

OLY,D790-SM (4909)<br />

AU<br />

Ultrasonic high temperature probe for PAN,26MG<br />

& OLY,38DL. 5MHz 7.9mm tip diameter. Operating<br />

temperature range -20 to 500ºC.<br />

PCWI 30kVDC Porosity (Holiday) Detector<br />

PCW,DC30 (4812)<br />

AU<br />

DC Porosity (Holiday) detector. Detects pinholes in coatings above 150um<br />

on metal substrates such as pipes and tanks. 0-30kV, 3.5 digit LCD display<br />

with battery indicator, display of voltage level. Alarm indicated on front panel,<br />

supplied with rechargeable battery, 10h charger, probe handle with neon<br />

and 2m length cable, 60mm connector for flat brushes, 7m earth cable with<br />

clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension. Dry<br />

conditions.<br />

PCWI 40kV Pulse Porosity (Holiday) Detector<br />

PCW,P40-PULSE (4814)<br />

AU<br />

Pulse porosity (Holiday) detector. Detects pinholes<br />

in coatings and wrapping above 150μm on metal<br />

substrates such as pipes and tanks. Can be used on<br />

dry or wet surfaces. 0 to 40kV output, 4 digit LED<br />

display of voltage, alarm sensitivity setting between<br />

dry and wet. Supplied with rechargeable battery,<br />

10h charger, red probe handle and 2m length of rubber coated cable, 60mm<br />

connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat<br />

brass wire brush, 450mm probe extension and 80mm probe extension.<br />

57


Olympus<br />

ultrasound | phased array | eddy current | eddy current array | remote visual inspection | X-ray fluorescence<br />

Olympus designs, manufactures, and globally markets a range of innovative nondestructive<br />

testing and remote visual inspection instruments developed with a commitment to technology,<br />

design, and user friendliness.<br />

These products are used for inspection and maintenance in industrial and research fields<br />

ranging from aerospace and energy to transportation and manufacturing. Olympus instruments<br />

contribute to product quality and add to the safety of infrastructure and facilities. Olympus has<br />

earned industry-wide reputations for providing cost-effective solutions and<br />

Solutions<br />

Corrosion Testing<br />

Weld Inspection<br />

Security<br />

Flaw Detection<br />

Thickness Measurements<br />

Automated Testing<br />

Image Capture<br />

<strong>Tech</strong>nologies<br />

Ultrasound<br />

Eddy Current<br />

Remote Visual Inspection<br />

X-Ray Fluorescence<br />

excellent support and<br />

customer service.<br />

Ultrasound Phased Array<br />

Eddy Current Array<br />

High-Speed Video<br />

Tel.: 1300 132 992 • Fax: (03) 9540 0924 • info@olympus.com.au<br />

For worldwide representation visit www.olympus-ims.com


www.techrentals.com.au<br />

Physical Measurement<br />

Non-Destructive Testing cont’d.<br />

Phynix Surfix FN Ferrous/Non Ferrous Coating Thickness Tester<br />

PHY,SURFIX FN (4803)<br />

AU<br />

Thickness tester with memory and statistics. Supplied with external probe,<br />

calibration standards and carry pouch. Measurement range 0 to 1,500μm or<br />

0 to 60mils (selectable), tolerance ±1μm +3% of reading, resolution 0.1μm.<br />

Display back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min substrate<br />

thickness type F 0.5mm, type N 50μm. Calibration factory, zero, foil. Data<br />

memory 80 readings max. Interface infra-red download data to PC utilising<br />

hyper terminal.<br />

Wylam Hill Paint Thickness Gauge<br />

WYL,PORTAPAINT<br />

MY<br />

Rugged, fully electronic coating thickness gauges use magnetic and<br />

eddy current principles to measure coating thickness on both ferrous and<br />

non-ferrous metals, accurately and quickly.<br />

Micrometers<br />

Position Transducers<br />

Mitutoyo 500-172 Digimatic Caliper<br />

MIT,500-172 (4965)<br />

AU<br />

Range 0 to 200mm (0 to 8”), resolution 0.01mm<br />

(0.0005”). Absolute measurement, LCD display.<br />

Temperature operating range 0 to 40ºC, storage<br />

temperature -10 to 60ºC. Button settings on/off,<br />

inch/mm. Origin, zero/ABS.<br />

MEL M5-200 4 to 20mA Optical Position Transducer<br />

MEL,M5-200 (5315)<br />

AU<br />

Optical distance measurement device 4 to 20mA<br />

output. Will measure distance from 240mm to 440mm<br />

with an accuracy of 0.06mm. Does not require a<br />

reflector on the surface of the device. Light spot<br />

diameter is 10mm. Light sensor is IP67. 4 to 20mA<br />

transmitter is IP40. Will operate from 10 to 30V. Relay<br />

outputs indicate error condition. 1ms, 2ms or 20ms adjustable reaction time.<br />

Light source infrared 890nm invisible.<br />

Inclinometers<br />

Wyler Clinitronic 45 Inclinometer RS-232C<br />

WYL,CL45 (5326)<br />

AU<br />

Resolution 0.01º. Accuracy better than 30arc sec. Display inclination in all<br />

common measurements. Includes RS232 interface for remote display of<br />

inclination and also logging. Settling time


Physical Measurement<br />

www.techrentals.com.au<br />

Load Cells cont’d.<br />

Dillon ED2000 5,000kg Crane Scale<br />

DIL,ED2000-5K (4452)<br />

AU<br />

Complete with shackles. Range 5,000kg. Accuracy 0.1%.<br />

Resolution 1kg. i.e. 20kg uncertainty. Units of measure: kg, kt,<br />

mt, & lb. Proof load 200% of rated load. Displays gross and net<br />

force. Continuous measurement and peak hold.<br />

Futek IHH500 Pancake Load<br />

Cell 2T Capacity<br />

FUT,IHH500-2T (4416)<br />

AU<br />

The IHH500 display and LCF400-FSH03132<br />

load cell operate at up to 2 tonnes (5000lb) in<br />

compression and tension. The IHH500 hand held<br />

display is a logging microcontroller which can store up to 21,000 points,<br />

it is powered by a rechargeable battery which can last for up to 30 hours<br />

depending on battery condition and load. It will operate from its mains<br />

charger if needed. Has a simple ‘Tare’ function and can display ‘Max Hold’<br />

using a single front panel key. The lead that connects the loadcell to the<br />

display is 1.6 Meters long. The load is connected via M12x1.75-Threads.<br />

Software is supplied on a USB flash drive / dongle.<br />

Futek IHH500 Pancake Load Cell 20T<br />

Capacity<br />

FUT,IHH500-20T (4418)<br />

AU<br />

IH500 display and LCF500-FSH02968 load cell operate<br />

at up to 20 tonnes (50,000lb) in compression and tension.<br />

The IHH500 hand held display is a logging microcontroller<br />

which can store up to 21,000 points, it is powered by<br />

a rechargeable battery which can last for up to 30 hours<br />

depending on battery condition and load. It will operate from its mains<br />

charger if needed. Has a simple ‘Tare’ function and can display ‘Max Hold’<br />

using a single front panel key. The lead that connects the loadcell to the<br />

display is 1.6 Meters long. The load is connected via M33x2-Threads.<br />

Software is supplied on a USB flash drive / dongle.<br />

Weighing & Counting Scales<br />

Over 8kg<br />

See also Balances & Scales Below 8kg on page 74<br />

A&D Mercury FC-10K Counting Scales<br />

AND,FC-10K (4435)<br />

AU<br />

High resolution 10kg scales with sample counting facility. Display<br />

resolution 1g, internal resolution 0.02g. Sample size user selectable –<br />

normally 10 pieces. Max count size up to 999,999. AC & NiCd battery<br />

operation.<br />

A&D Mercury FG-150KB 150kg Scales<br />

AND,FG-150KB (4437)<br />

AU<br />

Capacity 150kg, 0.05 resolution. Includes RS232 port. National Standards<br />

Commission approved (NSC).<br />

A&D Mercury FS-15kg Weighing Scales<br />

AND,FS-15KA (4434)<br />

AU<br />

High resolution 15kg scales. Display resolution 1g. AC & NiCad battery<br />

operation.<br />

A&D HP-40KA 40kg Counting Scale<br />

AND,HP-40KA (4436)<br />

AU<br />

Capacity 40kg with 0.5g resolution. Can be used to determine battery<br />

weight change with charge, etc.<br />

Weighing & Counting Scales<br />

Over 8kg cont’d.<br />

Atlas TCS 60Kg Platform Scale<br />

ATL,TCS-60 (4441)<br />

AU<br />

60kG capacity. Rechargeable battery. 6 Digit display, 22mm height.<br />

Platform 450 x 600mm. Accuracy OIML III +/-50g.<br />

Vibration Analysis<br />

See also Noise & Sound Analysers on page 70-71<br />

B&K 8202 Vibration Impact Hammer<br />

BK,8202 (5010)<br />

AU<br />

For determining frequency response functions. Individually calibrated force<br />

transducer. Comes with 3 different tips and additional mass to enable pulse<br />

duration and frequency range to be determined.<br />

Blastronics UMX-SM-6 Explosion Logger<br />

BLA,UMX-SM-6 (5035)<br />

AU<br />

Triaxial geophones, microphone with logger used to determine explosion<br />

characteristics. Geophones auto-ranging to 110mm/s, resolution ±0.1mm/s.<br />

Microphone auto-ranging to 140dBL, resolution ±0.25dB. Sample rate 250,<br />

500Hz & 1kHz. Bandwidth geophones 4.5 to 500Hz. Microphone 2 to 500Hz.<br />

Includes software and download cable. Internal memory 4Mb. Power internal<br />

6VDC 2,600mAh Gel-cells, operating consumption 40mA, sleep mode 10mA.<br />

Continuous operation 65h, with 1w programmable timer schedule. Instrument<br />

has a display.<br />

Fluke 810 Vibration Tester<br />

FLU,810 (5050)<br />

AU/MY<br />

Tests rotating machinery to determine the status of<br />

gearing wear etc. Used to: Troubleshoot equipment<br />

and understand cause of failure. Commission new<br />

equipment and ensure proper installation. Includes<br />

triaxial accelerometer and laser tacho. Store and<br />

reports FFT images to your PC. Very simple output<br />

that reports Pass and Fail on machinery condition.<br />

Linear LSPC-1 1G Accelerometer DC to LF<br />

LIN,LSPC-1 (5034)<br />

AU/MY<br />

Designed for very low force levels ±1G measurement range. Operates down<br />

to DC in frequency. Output ±5V. Linearity 0.05%, resolution 0.001%. Shock<br />

Survivability 100g. Natural Frequency 100Hz.<br />

Madgetech Ultrashock-EB Transportation Logger<br />

MAD,ULTRASHOCK-EB (5025)<br />

AU<br />

Ultrashock-EB transportation ambient temperature, humidity, barometric<br />

pressure and 3 axis shock acceleration logger. Ranges: -40 to 180ºC,<br />

0-95%RH, 0 to 30PSIA (0-200kPa , -50g to +50g. Memory 23,831 readings<br />

per channel. Logging interval from 1 reading per 2s to 1 reading per 12h.<br />

Sampling rate 2ms. Includes RS232 interface and setting up, downloading,<br />

graphing software.<br />

PCB Low G Accelerometer DC to 300Hz<br />

PCB,300A20 (5014)<br />

AU<br />

Single axis accelerometer includes charge amplifier. Range ±20g, frequency<br />

(±5%) DC to 300Hz, (±10%) to 500Hz. Shock limit ±5kg. Operating temperature<br />

-40 to 85ºC. Weight 15g. Voltage sensitivity 100mV/g.<br />

60


www.techrentals.com.au<br />

Physical Measurement<br />

Vibration Analysis cont’d.<br />

Profound Vibra Ground<br />

Vibration Logger<br />

PRO,VIBRA (5023)<br />

AU<br />

Designed for long term ground vibration logging.<br />

Includes a Geophone and remote alarm with<br />

flashing light. Velocity Range 0 to 100mm/s. 4 weeks<br />

operation on 3 x D cell batteries. USB interface.<br />

<strong>Download</strong> possible while measuring. Full Windows<br />

analysis software included. IP65 case. Meets standards for ‘Vibration in<br />

buildings’ - Effects on structures’ and ‘Effects on persons in buildings’, such as<br />

the DIN 4150 – part 2 and 3, DIN 45669 and the SBR 2002.<br />

Rion VA-10 Vibration Analyser<br />

RIO,VA-10<br />

MY<br />

Measures acceleration, velocity and displacement. Stores 500 readings.<br />

LCD display with waveform, spectrum and data readout. Auto measurement<br />

function. Includes printer interface.<br />

Rion VA-11 Vibration Analyser<br />

RIO,VA-11 (5042)<br />

AU/MY<br />

Includes 2 pickup types hand held (PV55) and magnetic type (PV57).<br />

Measures acceleration, velocity and displacement. Displays RMS, peak and<br />

crest factor. Uses FFT to display power and vibration spectrum. Incorporates<br />

PCMCIA card flash memory for data storage. RS-232 interface available.<br />

PV57 1Hz to 5kHz, PV55 3Hz to 20kHz (velocity 3kHz, displacement 500Hz).<br />

Acceleration 0.02 to 316mm/s 2 rms. Velocity 0.1 to 1,000mm/s rms.<br />

Displacement 0.003 to 28.3 (EQ PP). High pass filter 3Hz, 10Hz & 1kHz. Low<br />

pass 1kHz, 5kHz and 20 kHz. Stores 500 measurements.<br />

Svantek SV100 Whole Body Vibration<br />

Analysis<br />

SVA,SV100 (5005)<br />

AU<br />

Completely self-contained, integrated unit. Does whole<br />

body vibration dose (exposure) measurements, octave<br />

measurements, time domain record measurements and<br />

motion sickness measurements. Includes external alarm,<br />

car power adapter or will run from battery pack for >16hrs.<br />

USB interface for programming and download.<br />

Svantek 912A Sound Vibration Analyser<br />

SVA,912A (5001)<br />

AU<br />

Type 1 sound level meter including a single axis accelerometer. Provides<br />

standard sound measurements and vibration measurements including 1/1<br />

octave, 1/3 octave and full spectrum. Will store 1Mb of spectrum analysis<br />

information for waterfall plots etc. PC interface software included. Can make<br />

part body vibration measurements. Includes SV06A 4 input module and a<br />

triaxial accelerometer.<br />

Vibration Analysis cont’d.<br />

Texcel ATM Explosion and<br />

Ground Vibration Logger<br />

TEX,ATM (5036)<br />

AU<br />

Triaxial geophone and overpressure (airblast) microphone<br />

with logger used to determine explosion and<br />

ground vibration characteristics. Geophone range to<br />

±55.6mm/s, resolution 0.014mm/s up to 6.95mm/s,<br />

0.109mm/s up to 55.9mm/s. Microphone range 80-dBL<br />

to 140dBL, resolution 0.049Pa up to 122dBL (25Pa), 0.40Pa up to 140dBL<br />

(201Pa). Sample rate 20, 50, 100, 200, 500Hz & 1kHz. Bandwidth: geophone<br />

4.5Hz to 500Hz, microphone 2Hz to 500Hz. Includes software and download<br />

cable. Internal memory 2Mb. Power internal 12VDC 7Ah batteries. Continuous<br />

operation 240h. Supplied with 90 to 260V 50/60Hz charger, recharge time 8h<br />

approx. 16 character LCD display, weatherproof enclosure, rated IP65.<br />

Operating temperature 0 to 70ºC, display 0 to 50ºC. Supplied with alarm light,<br />

reset button and 2 x 15m cable. External DC power supply cable also supplied.<br />

Speed Measurement<br />

TR Viblog Vibration<br />

and GPS Logger<br />

TR,VIBLOG (5060)<br />

AU<br />

Incorporates a 3D accelerometer, a 3D gyroscope<br />

and a 10Hz GPS system. The instruments logs<br />

10 measurements per second. It records these<br />

measuremnts and also provides a a Google<br />

Earth plot of the horizontal vibration and verticle<br />

vibration by location. A histogram of the vibration<br />

agains velocity is provided also. The loggers<br />

battery lasts around 24hrs. It has sufficent memory<br />

to record 10 samples per second over this time.<br />

Phantom 53550 Radar Gun with Case<br />

and Tuning Fork<br />

PHA,53550 (5324)<br />

AU<br />

Doppler K band (24.150GHz) stationary radar<br />

gun. Pull the trigger and the speed display<br />

appears instantly. Invisible to all radar detectors.<br />

Power requirements 10.5 to 16.5VDC, 13.5VDC nominal, 1.5A max, external<br />

source, connection via 1.8m coiled power cord with fused lighter plug.<br />

Operating environment -20 to 60ºC, 90%RH @ 37ºC (non-condensing).<br />

Accuracy ±0.17kph. Accuracy verification tuning fork (K-Band), internal 90kph.<br />

Speed range 17 to 332kph.<br />

TR VMS HAS CALIBRATED EQUIPMENT FROM OVER 2,400<br />

MANUFACTURERS - IMPRESSIVE BY ANY MEASURE.<br />

To minimise downtime, TR VMS provide a Booking Service to assist you in effectively and efficiently managing your<br />

equipment utilisation. Just call your nearest TR VMS office and arrange a date for the next available time slot.<br />

A quote will be provided stating that the equipment is to arrive at the TR VMS office the day before the work is due to be<br />

done. Simply sign the acceptance of the quote and return.<br />

You have the choice of a Hypercal Calibration Service, for when the calibration is urgent, and your job will be “next on the<br />

bench” and in most cases with a one day turnaround. There is a surcharge for this service. Otherwise utilise the Standard<br />

Calibration Service with up to 10 business days for calibration.<br />

Please call TR VMS for quotation on 1300 790 480 or email info@trvms.com.au<br />

61


Construction, Building Services & Survey<br />

www.techrentals.com.au<br />

Air Conditioning & Air Flow<br />

Air Conditioner Valve Balancing<br />

Concrete Testing Equipment<br />

Underground Services Location<br />

Utility Leak Detection<br />

Ground Penetrating Radar<br />

Pipeline & Cavity Inspection<br />

Material Moisture Meters<br />

Distance Measurement & Surveying<br />

Air Conditioning & Air Flow<br />

Airflow AV2 100mmØ Anemometer with Volume Display<br />

AIR,AV2 (5836)<br />

AU<br />

Vane anemometer with 900mm telescopic probe extension. Velocity<br />

measurement range 0.25 to 30m/s. Averaging mode available. Volume display<br />

based on duct or other area. Head operating range -10 to 70°C (lower limit of<br />

-30°C for short periods). Output 0 to 1V.<br />

Airflow AV2 100mmØ Anemometer NATA Certification<br />

AIR,AV2-NATA (5837)<br />

Specification as above but with NATA certification.<br />

Airflow 36 Pitot Tube<br />

AIR,PITOT-36 (5816)<br />

Pitot tube (36”) for use with manometers and micro manometers.<br />

Alnor EBT-721-A3 Electronic Micromanometer<br />

ALN,EBT-721-A3<br />

MY<br />

Detachable multi-purpose digital manometer that can be used with the<br />

following test and balance tools, such as pitot, air foil, temperature, relative<br />

humidity probes or a 16-point velocity matrix. Differential pressure: ±15 in.<br />

H 2<br />

O, (3735 Pa) 150 in. H 2<br />

O maximum safe operating pressure. Absolute<br />

pressure: 15 to 40 in. Hg (356 to 1016 Hg). Velocity: 25 to 8,000 ft/min (0.125<br />

to 40 m/s) pitot probes; 25 to 5,000 ft/min (0.125 to 25 m/s) air flow probe;<br />

25 to 2,500 ft/min (0.125 to 12.5 m/s) velocity matrix. Volume: 25 to 2,500<br />

ft 3 /m (42 to 4250 m 3 /h) capture hood. RH: 0 to 95% RH (optional probe),<br />

Temperature: -40 to 250°F (-40 to 121°C) probe dependant. Standard comes<br />

with 2ft x 2 ft, upon request additional hood of 2ft x 4 ft and 1ft x 4ft hood would<br />

be provided.<br />

Alnor EBT721-Z Balometer Electronic Balancing Tool with detachable<br />

Multi-purpose Digital Manometer<br />

ALN,EBT-721-Z3<br />

MY<br />

The unit comes with the following test and balance tools, such as pitot, air foil,<br />

temperature, relative humidity probes or a 16-point velocity matrix. Differential<br />

pressure ±15in H2O, (3735Pa) 150in H 2<br />

O maximum safe operating pressure.<br />

Absolute pressure: 15 to 40in Hg (356 to 1016Hg). Velocity: 25 to 8,000ft/min<br />

(0.125 to 40m/s) pitot probes; 25 to 5,000ft/min (0.125 to 25m/s) air flow probe;<br />

25 to 2,500ft/min (0.125 to 12.5m/s) velocity matrix. Volume: 25 to 2,500ft 3 /m<br />

(42 to 4250m 3 /h) capture hood.<br />

CSS Portable Smoke Generating Machine<br />

CSS,COLT4 (5890)<br />

AU<br />

Portable smoke generator with variable smoke emission<br />

rate. Suitable for air flow visualisation, HVAC ductwork<br />

leak-testing, fire training and general work. Pump-free<br />

operation with smoke fluid supplied from consumable aerosol cans. Manual or<br />

continuous operation and off-power facility. Maximum output 31 cubic meters/<br />

min at 1.5m visibility. Operation for 18min from one can at maximum capacity.<br />

AU<br />

AU<br />

Air Conditioning & Air Flow cont’d.<br />

Druck DP1705 Manometer 0 to 20kPa<br />

DRU,DPI705 (5808)<br />

AU<br />

Handheld digital manometer range 0 to 20kPa, accuracy 0.2%. Displays all<br />

common engineering units.<br />

Druck DPI705-IS Manometer 0 to 20kPa<br />

Intrinsically Safe<br />

DRU,DPI705-IS (5809)<br />

AU<br />

Hand held Manometer 0 to 20kPa range. Accuracy 0.2%.<br />

Displays all common engineering units. Intrinsically Safe.<br />

Shortridge ADM-860 Electronic Manometer<br />

SHO,ADM-860 (5812)<br />

AU<br />

Electronic micromanometer for air balance and similar applications. Measures<br />

differential pressure, air velocity and temperature using accessories included.<br />

Differential pressure range 0.0025 to 1500 mm water gauge. Air velocity range<br />

7.5 to 3,000 m/min (750 m/min with velgrid). 100 point memory with sum and<br />

average. Accessories include pitot tube and a 16 point velgrid for face velocity<br />

work including exhaust hoods, clean room outlets, and large filters or coils.<br />

Shortridge CFM88-3 Electronic Balometer<br />

SHO,CFM88-3 (5830)<br />

AU<br />

Measures supply and exhaust flow in cfm and l/s. Ranges 25 to 2500cfm<br />

supply and 25 to 1500cfm exhaust. Compensated for air density and back<br />

pressure. Hood sizes 600 x 600mm, 600 x 1,200mm & 300 x 1,200mm.<br />

Testo 445 Vane Anemometer with 16mm Vane<br />

TES,445 (5842)<br />

AU<br />

Micro-vane probe. Simultaneous digital display of air<br />

velocity and temperature, with continuous-update,<br />

max, min & mean functions. Volume-flow option<br />

with entry of duct dimensions. Telescope mounted<br />

metal probe, vane 16mmØ. Operating range 0.4 to<br />

60m/s, accuracy ±0.2 m/s, ±1%mv up to 40m/s.<br />

Temperature range -30 to 140ºC for short-term<br />

measurements. Selectable site-locations, and 3,000<br />

point internal memory for manual saving or automatic<br />

data logging. Battery powered.<br />

TSI 8324 VelociCalc 100mm<br />

Vane Anemometer<br />

with Volume Display<br />

TSI,8324 (5839)<br />

AU<br />

Vane anemometer with 100mm head,<br />

supplied with handle and 900 mm<br />

articulated telescopic extension. Velocity<br />

measurement range 0.25 to 30m/s ±1%;<br />

temperature measurement range 0 to 80ºC ±0.5 ºC. Volume display range<br />

0 to 4.36 x 106m 3 /h with input for circular or rectangular duct dimensions.<br />

Variable time-constant; sample statistics average, max and min; and “sweep”<br />

mode for extended continuous sampling. Internal memory for single point<br />

measurements or time-based data logging, for up to 2849 samples and 1,000<br />

test IDs, with serial interface, cable and software for data download. Direct<br />

data acquisition [polling] from PC terminal modes. Battery powered with<br />

auto-power-off, and optional AC adaptor.<br />

TSI 8345 Hot Wire Anemometer<br />

TSI,8345 (5844)<br />

AU<br />

Thermal anemometer range 0.15 to<br />

30m/s; accuracy ±3%; volumetric flow display;<br />

averaging capability up to 255 readings. Probe<br />

operating temperature range -17.8 to 93.3°C.<br />

Probe 98mm long x 6mmØ at tip. Digital display.<br />

RS232C printer interface. Battery or mains<br />

operation.<br />

62


www.techrentals.com.au<br />

Construction, Building Services & Survey<br />

Air Conditioning & Air Flow cont’d.<br />

TSI 8373 Balometer With Logging<br />

TSI,8373 (5826)<br />

AU/MY<br />

Flow range 15 to 1,000l/s (54 to 3,600m 3 /h); accuracy ±5% [to ±2.4l/s].<br />

Operating temperature range 0 to 60°C. Includes 5 hood kit & hard case.<br />

Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm,<br />

305 x 1,525mm & 915 x 915mm.<br />

TSI 8375 Accubalance Modular Air Balancing Tool<br />

TSI,8375 (5827)<br />

AU<br />

Balometer with detachable micromanometer (TSI 8710) for air balancing<br />

applications. With 610 x 610mm air capture hood for measurements in the<br />

range 42 to 4250m 3 /h with automatic compensation for barometric pressure<br />

and air temperature, 45cm pitot probe [range 0.13 to 41m/s], 16-point velocity<br />

matrix probe [0.13-13m/s] and static pressure probes [differential pressure<br />

range ±3735Pa with safe limit 37kPa, absolute pressure range 47 to 135kPa.<br />

Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit LCD<br />

display for single or statistical readings with min, max and average of up to<br />

1,000 values of each measured parameter. Manual result storage or automatic<br />

data logging up to 1,000 time/date stamped readings. RS232 port for data<br />

transfer to PC or serial printer, with cable and “LogDat” download software.<br />

Rechargeable with approx 12h operation, or AC adaptor.<br />

TSI 8386A VelociCalc Air Conditioning Efficiency Meter<br />

TSI,8386A (5848)<br />

AU<br />

Portable efficiency measurement system for HVAC and related<br />

work, with hot wire anemometer, static and differential pressure, temperature<br />

and humidity measurement with heat flow efficiency calculation. Velocity (hot<br />

wire) 0 to 50m/s, accuracy ±3%. Temperature -10 to 60°C, accuracy ±0.3. Wet<br />

bulb temperature 5 to 60°C. Relative humidity 0 to 95%RH, accuracy ±3%.<br />

Dewpoint -15 to 49°C. Static/differential pressure -1,245 to 3,735Pa, accuracy<br />

±1%. Probe length 100cm, tip diameter 7mm, base diameter 10mm. Includes<br />

data logging and printing. Battery operated.<br />

TSI 8705 DP-CALC Differential Micro-Manometer<br />

TSI,8705 (5815)<br />

AU<br />

Differential micro-manometer measuring differential<br />

pressure, velocity, average, volumetric flow, maximum<br />

and minimum. With static pressure calculations, density<br />

correction and K factor. Pressure range -1245 to 3735Pa.<br />

Velocity range 1.27 to 78.5m/s. Supplied with 200 to<br />

980mm telescopic pitot tube. Datalogging (1,000 point) with<br />

RS232C interface and software. Battery powered.<br />

TSI 8710 DP-CALC Differential<br />

Micro-Manometer<br />

TSI,8710 (5813)<br />

AU<br />

Micro-manometer for static or differential<br />

pressure, velocity, volumetric flow, atmospheric<br />

pressure and temperature. With statistical<br />

analysis, density correction, K factor and<br />

automatic actual/standard flow calculation.<br />

Differential pressure range ±3735Pa. Velocity display to 41m/s (range depends<br />

on probe). Supplied with static tip, pitot tube, velocity matrix and temperature<br />

probe. Datalogging (1,000 point) with RS232C interface and software.<br />

Rechargeable cells or AC adaptor.<br />

TSI 9535 Anemometer with Logging Capability<br />

TSI,9535 (5845)<br />

AU<br />

Includes data captured download software and USB cable. Logs<br />

velocity and temperature. Will calculate flow rates. 0 to 30m/s Accuracy 3%<br />

of reading or ±015m/sec whichever is greater. Temperature range -18 to 93°C<br />

±0.3°C. Runs 4 x AA batteries.<br />

Air Conditioning & Air Flow cont’d.<br />

TSI 9555 Multi-Function Ventilation Meter<br />

TSI,9555<br />

MY<br />

Portable, hand held, multi-function ventilation meter. Comes with differential<br />

pressure and 966 articulate probe which measures air velocity, temperature<br />

and humidity. Calculations include air flow, heat flow, turbulence, wet bulb and<br />

dew point temperature. Velocity measurement: Range: 0 to 9,999 ft/min (0<br />

to 50 m/s) , Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s), Resolution:<br />

1 ft/min (0.01 m/s). Temperature measurement: Range: 14 to 140°F (-10<br />

to 60°C), Accuracy: ±0.5°F (±0.3°C), Resolution: 0.1°F (0.1°C). Humidity<br />

measurement: Range: 0 to 95% RH, Accuracy: ±3% RH, Resolution: 0.1%<br />

RH.<br />

TSI 9565A VelociCalc Air Conditioning Efficiency Meter<br />

TSI,9565A (5849)<br />

AU<br />

Portable efficiency measurement system for HVAC and related<br />

work, with hot wire anemometer, static and differential pressure, temperature<br />

and humidity measurement with heat flow efficiency calculation. Velocity (hot<br />

wire) 0 to 50m/s, accuracy ±3%. Temperature -10 to 60°C, accuracy ±0.3.<br />

Wet bulb temperature 5 to 60°C. Relative humidity 0~95%RH, accuracy ±3%.<br />

Dewpoint -15 to 49°C. Static/differential pressure -3,735 to 3,735Pa, accuracy<br />

±1%. Probe length 1m, tip diameter 7mm, base diameter 10mm. Includes data<br />

logging and printing. Battery operated. USB & Bluetooth download.<br />

Vaisala WAA151 Wind Speed/Direction Transducer<br />

VAI,WAA151 (5886)<br />

AU<br />

Range 0.4 to 75m/s. Current output with selectable ranges including 4 to<br />

20mA & 0 to 20mA. Requires indicator module such as DE,DT600 datalogger<br />

for indication of wind speed and direction.<br />

Air Conditioner Valve Balancing<br />

See also Data Loggers: Testo Temperature & Humidity Loggers<br />

on page 53<br />

Tour & Anderson CBI<br />

Balancing Meter<br />

TA,CBI (5800)<br />

AU<br />

Digital pressure balancing instrument with<br />

LCD display. For cooling water valve<br />

balancing in air conditioning plants and similar<br />

applications. Firmware revision 3A. Includes<br />

facility for entry of Kv value to allow balancing<br />

of all hydronic valve types. Differential<br />

pressure range -0.5 to 20.5m water gauge at a total pressure of less than<br />

200m. Resolution 0.001m. Flow resolution 0.001l/s. Battery operated.<br />

Tour & Anderson Scope<br />

Balancing Meter 1000kpa<br />

TA,SCOPE (5801)<br />

AU<br />

Digital flow balancing instrument with color<br />

display. For cooling water valve balancing in<br />

air conditioning plants and similar applications.<br />

Includes facility for entry of Kv value to allow<br />

balancing of all hydronic valve types. Differential<br />

pressure range -0.5 to 20.5m water gauge at<br />

a total pressure of less than 200m. Resolution<br />

0.001m. Flow resolution 0.001l/s. Battery<br />

operated.<br />

63


Construction, Building Services & Survey<br />

www.techrentals.com.au<br />

Concrete Testing Equipment<br />

See also Endoscopes, Borescopes & Visual Inspection on page 45<br />

See also Ground Penetrating Radars on page 65<br />

See also Pipeline & Cavity Inspection on page 66<br />

Elcometer 331-B Basic Cover Meter<br />

ELC,331-B (4924)<br />

AU/MY<br />

Displays depth and orientation of the reo bars.<br />

Deep search head supplied. 40mm diameter bar<br />

depth 35 to 180mm depth, 8mm diameter bar<br />

depth 25 to 160mm depth. Rechargeable battery<br />

allows 32h of continuous operation (20h with backlight).<br />

Elcometer 331-SH Cover Meter with Half Cell Measurement<br />

ELC,331-SH (4919)<br />

AU<br />

Displays the depth and orientation of the reo bars. Standard search head.<br />

40mm diameter bar depth 15 to 95mm. 8mm diameter bard depth 8 to<br />

70mm. Rechargeable battery allows 32h of continuous operation (20h with<br />

backlight). Autosizing of bars or orthogonal measuring of bar sizes. Internal<br />

storage of readings of depth of cover in batches which can be downloaded to<br />

PC with supplied software. XP and Vista supported.<br />

Hilti PS20 Rebar, Copper Pipe & Electrical<br />

Cable Locator<br />

HIL,PS20 (4920)<br />

AU<br />

Localise and position of reinforcement, (rebars) copper,<br />

aluminium pipes and unshielded live electric cables. Depth<br />

range for detection of rebars 0 to 100mm, for copper &<br />

aluminium pipes 60mm, rebar diameter 8 to 36mm, depth<br />

detection accuracy 10 to 30mm ±2mm, above 30-60mm<br />

± 2mm ±10% depth, above 60 to 80mm ±5mm ±10% depth, based on 12mm<br />

rebars. Detection of copper & aluminium pipes based on 10 to 30mmØ, only<br />

detection with depth of 0 to 60mm, no depth reading, same for live electric<br />

cables, cannot detect live cables in metal conduit or shielded cables.<br />

Hilti PS200 Ferroscan System<br />

HIL,PS200 FERROSCAN (4921) AU<br />

Portable, quick and easy to<br />

use for detecting rebar and other ferrous objects<br />

in concrete structures. Provides accurate on-site<br />

rebar location, depth and diameter with the PS<br />

200M monitor. Scans can be evaluated on the<br />

monitor or transferred to a PC or laptop for further<br />

evaluation and report generation. Portable wireless operation, easy integrated<br />

LCD display makes setting up the scan easy while providing information<br />

over the scan process. Fast data download via infra red beam from scanner<br />

to monitor. Convenient Scanner stores up to 9 image scans and 30m of<br />

Quickscans.<br />

Hilti PS1000 X-scan<br />

Concrete GPR System<br />

HIL,PS1000 (4923)<br />

AU<br />

A GPS system with 3 transmitters and 5<br />

receivers that has been designed to provide a 3D image of the location of<br />

reinforcement bars and other metallic and non metallic objects in concrete.<br />

Accuracy +/-10mm. It will measure to a depth of 300mm.<br />

Handy Search<br />

NJJ-95B Reinforced<br />

Concrete Radar<br />

JRC,NJJ-95B (4923)<br />

AU<br />

Ground Penetrating Radar (GPR) technology<br />

applied to the location of reinforcement<br />

in concrete. Unit will search to a depth<br />

of 300mm. Display is very easy to interpret (scanned images). Scan<br />

information can be saved to a memory card for transfer to a PC. A 3D<br />

image of the slab can be generated using PC software. Can be used to<br />

detect voids in concrete and the concrete depth is easy to determine from<br />

the image. The location of non-metallic objects can also be determined.<br />

Concrete Testing Equipment cont’d.<br />

Olsen FTG Concrete Thickness Gauge<br />

OLS,FTG (4929)<br />

AU<br />

Concrete thickness gauge utilising the impact echo test method. Can<br />

measure concrete thickness in two ranges: 6 to 60cm and up to 1.8m.<br />

This concrete thickness gauge is a battery operated handheld system for<br />

measuring the flaws and thickness of concrete slabs, pavements, walls<br />

and other plate-like structures from one side. Up to 300 readings can be<br />

stored in the field before the memory is full. RS232 interface and transfer<br />

software supplied.<br />

Proceq 2000-ND Digi Schmidt Test<br />

Hammer<br />

PRO,2000-ND (4930)<br />

AU<br />

Concrete hardness tester (Schmidt<br />

hammer). Supplied complete with inbuilt<br />

graphical LCD for setting up and graphical<br />

display of results, up to 500 results can<br />

be stored. RS232 interface and software<br />

supplied for down loading. Impact energy 2.207Nm. Engineering units of<br />

results in N/mm 2 , MPa, psi, kg/cm 2 . For concrete thickness greater than<br />

100mm.<br />

Proceq Profoscope Rebar Locator & Cover Meter<br />

PRO,PROFOSCOPE (4926)<br />

AU<br />

Rebar locator and covermeter. Short range measurements<br />

to 95mm ±3mm accuracy. Long range 185cm accuracy<br />

± 4mm. The unit will determine the position of the rebars, the<br />

mid point between rebars, Concrete cover, estimation of bar<br />

diameter & the orientation of the rebar. Powered by 2 x AA<br />

batteries. Battery life 15h with backlight 55h without.<br />

Proceq Resistivity Meter<br />

PRO,RESIPOD (4925)<br />

AU<br />

Can determine the likelihood of corrosion and the<br />

corrosion rate in concrete. 0 to 1,000kΩ measurement<br />

range. USB interface, USB charging. Waterproof.<br />

Proceq SilverSchmidt UN Concrete<br />

Test Hammer<br />

PRO,SIL-UN (4928)<br />

AU<br />

Requires no corrections for angle of test,<br />

simple one button operation, datalogging<br />

capability with USB download with detailed reporting capability. Impact<br />

energy 2.207Nm. Compressive strength range 10 to 170MPa. Battery Life<br />

>1,000 Impacts before recharging is required.<br />

Protimeter Moisture Measurement System<br />

PRO,MMS-PLUS (4955)<br />

AU<br />

Moisture meter for detection of moisture in non conductive solid materials<br />

such as wood and masonry. Two measurement modes, search for<br />

qualitative measurements and measure mode for precise and localised<br />

moisture content. Supplied with pin type probes, deep wall probes,<br />

hygrometer probe and extension cord for RH, ambient temperature or<br />

dew point temperature. Hygrostick probe supplied for surface temperature<br />

measurement. Logging software and RS232 computer interface supplied.<br />

See also Material Moisture Meters on page 66<br />

64


www.techrentals.com.au<br />

Construction, Building Services & Survey<br />

Underground Services Location<br />

See also Prospecting Metal Detectors on page 75<br />

Cable Ezidig Detection Excavator<br />

Mounted Cable Locator<br />

CAB,EZIDIG (3690)<br />

AU<br />

Excavator mounted service locator. This<br />

cable avoidance tool is designed to give real<br />

time warnings to an excavator operator of<br />

buried magnetic services. The kit includes<br />

the sensor unit which is mounted on the<br />

excavator arm, the In-Cab display and a<br />

signal generator.<br />

CScope CATXDSGV-KIT<br />

Cable and Pipe Locator<br />

CSC,CATXDSGV-KIT (3664)<br />

AU<br />

Kit includes a generator with touch button controls and<br />

LCD display and an XD receiver/locator operating at<br />

33kHz. Operates in power or radio modes. Accessories<br />

include direct connection cable, ground stake and<br />

75mm diameter tong set. Transmitter operates by direct<br />

connection, or induction via the tongs. Determines cable<br />

depth, range 0.2m to 3m. Battery powered.<br />

CScope CATXDSGA-KIT<br />

Cable and Pipe Locator<br />

CSC,CATXDSGA-KIT<br />

MY<br />

Industry standard locator to use to determine<br />

the exact location of buried pipes and cables<br />

immediately prior to any form of excavation work<br />

taking place. 3 position function select switch:<br />

Power mode for detecting live imbalanced cables. (Depth range 3m). Radio<br />

mode for detecting re-radiated radio signals. (Depth range 2m). Generator<br />

mode for detecting conductors carrying the signal generated by the C.Scope<br />

signal generator. (Depth range 3m). Frequency: power mode 50-400Hz, radio<br />

mode 15-20kHz, generator mode 33kHz.<br />

Radiodetection Flexisonde Pipe Tracer<br />

RAD,FLEXISONDE (3668)<br />

AU<br />

Flexible rod on reel 50m long complete with 1 33mm diameter sonde. Sonde<br />

can be detected at 5m depth and is suitable for insertion into plastic pipes of<br />

80mmØ & 210mm min bend radius. Sonde operates at 8 KHz.<br />

Radiodetection A Frame for RAD,RD4000 Type 7 Kit<br />

RAD,AFRAME FORRD4000 (3678)<br />

AU<br />

A-Frame accessory for RAD,RD4000Type7KIT. For sheath to ground type<br />

ault finding.<br />

Radiodetection RD4000 Type 7<br />

Cable Location Kit<br />

RAD,RD4000TYPE7KIT (3676)<br />

AU<br />

Includes transmitter and locator. Receiver has<br />

640Hz, 8, 33 and 82kHz, 2 power and radio modes.<br />

3 locating modes - 2 peak, 1 null. Location arrows,<br />

simultaneous digital depth and current readout.<br />

Transmitter T10 version, FF, 640Hz, 8, 33 and<br />

82kHz transmission freq. LCD display for freq,<br />

power, battery and connection readout, multimeter<br />

function, cable fault find function, 10W output, high efficiency induction mode.<br />

Signal clamp 100mmØ. Connection leads and carry bag.<br />

Underground Services Location<br />

cont’d.<br />

Vivax VLOCPRO Pipe and<br />

Cable Location System<br />

VIV,VLOCPRO (3676) AU<br />

Pipe and Cable locator with intuitive menu<br />

system, colour display, peak, null, left/right<br />

and orientation (compass) response to support your preference. Configured<br />

with 6 location frequencies, power and radio modes. 10 watt transmitter can<br />

apply the location signal by connection, induction and signal clamp. Depth<br />

detection up to 6 to 9 meters in broad-peak mode.<br />

Utility Leak Detection<br />

Gutermann Aquascope 3 Leak Locator<br />

GUT,AQUASCOPE3 (3683)<br />

AU<br />

Listens for the sound of a leak. Specific digital signal processing,<br />

designed to remove electrical noise and provide the operator with only the sound<br />

of the leak. Includes both ground and hand probe microphones. The display<br />

indicates the level of the noise from the leak. That way you can determine when<br />

you are nearest to the leak i.e. when the level is at its highest, you are nearest to<br />

the leak.<br />

ICC LD400 Ultrasound Leak and Emission Detector<br />

ICC,LD400 (3688)<br />

AU<br />

Used to detect water and gas leaks, from ultrasonic emission. Also used for<br />

mechanical noise location. Supplied complete with an ultrasonic transmitter to<br />

enable leaks within containers to be detected, e.g. vehicle bodies, fuel tanks. Aural<br />

and visual indication. Battery operated.<br />

Ultra Probe UP100KT Ultrasonic Leakage<br />

Detector<br />

ULT,UP100KT (3685)<br />

AU<br />

Hand held pistol type with stainless steel sensor<br />

enclosure. Frequency reponse 20 to 100kHz,<br />

(centred at 28 to 42kHz), 10 segment LED bargraph (red). Sensitivity 8 precision<br />

attenuation. Response time 300ms, operating temperature range 0 to 50°C. Kit<br />

includes contact stethoscope module with different wave guide extension rods<br />

for direct for use on pipes, bearing housings, steam traps, etc. Rubber focusing<br />

probes, head set, warble tone generator for determining leaks in seals of empty<br />

containers, etc.<br />

Ground Penetrating Radar<br />

See also Concrete Testing Equipment on page 64<br />

USRadar Ground Penetrating Radar System<br />

USR,SEEK-SPR (3601)<br />

AU<br />

Designed to locate buried objects. Typically used<br />

for the location of cables and pipe, detection of pipe<br />

and the detection of underground storage tanks. For<br />

targets as small as 5cm diameter and up to 4m depth.<br />

Please visit <strong>Tech</strong><strong>Rentals</strong> WIKI. This resource<br />

center provides manuals, technical information<br />

and how-to videos. www.techrentals.com.au<br />

select <strong>Tech</strong>nical Tips and Videos.<br />

65


Construction, Building Services & Survey<br />

www.techrentals.com.au<br />

Pipeline & Cavity Inspection<br />

See also Endoscopes Borescopes Visual Inspection on page 45<br />

Aqua Snakeeye Video<br />

Inspection System<br />

AQU,SNAKEEYE3 (5121) AU<br />

Handheld video system for<br />

remote inspection work. Very<br />

light and compact. Includes a 12.7cm TFT-LCD display and 3cm diameter<br />

camera including illumination. Various adapters are supplied for mounting<br />

the camera to: a) your hand b) a 45.7cm arm with 90 degree articulation, c)<br />

a 30m extension cable or d) an arm which extends from 1.6 to 3.6m. Includes<br />

memory card and will save images to card.<br />

Archos AV 500 Mobile Digital Video Recorder - 100 GB<br />

ARC,AV500 (5150)<br />

AU<br />

Unique mobile digital video recorder offering direct TV recording and the best<br />

of video, photo and music on the go on a 4” colour screen, 100 GB hard drive.<br />

Easy setup pod for TV recording & video playback , control your VCR, cable<br />

or satellite receiver. Record directly to TV or make scheduled recordings,<br />

photo wallet & music player. Stores up to 400 hours of video, 250 movies or<br />

1 million photos.<br />

Testo Fibrescope 1.2m with Guide Tube<br />

TES,319 (5119)<br />

AU<br />

Supplied with guide tube, 45 degree mirror &<br />

magnetic tip. Number of pixels 6,000. Fibreoptic<br />

field of view 50°. Angle of field of view<br />

45° ±5°. Min focus distance 15mm (focus).<br />

Max focus distance 150mm (light). Operating<br />

and storage temperature: -20° to 60C. Working temperature/probe<br />

-20° to 80°C. Probe diameter 6.5mm. Probe length 1247 mm ±6. Max<br />

bending radius 50mm. Light source LED 2 point light. Probe resistance:<br />

probe tip water-proof up to handle short-term resistance to silicone oils,<br />

petrol and kerosene. Oils or petrol must be wiped off immediately after<br />

immersion. Battery type 3AA batteries. Battery life 4h. Note: the<br />

magnetic tip can be used to remove small magnetic objects.<br />

Pipeline & Cavity Inspection cont’d.<br />

Wohler VIS2000Pro 30m x 51mm Colour<br />

Camera & Roller Guide<br />

WOH,VIS2000PRO (5112)<br />

AU<br />

Suitable for inspection of ventilation ducts, chimneys,<br />

chambers and flue gas systems, etc. Kit consists<br />

of colour display with a joystick to control camera.<br />

30m push rod cable on a reel, with a non-waterproof,<br />

splash resistant (IP64 rated) 51mm diameter colour camera with illumination.<br />

Accessories include a Roller Guide to allow the camera to be pushed down a<br />

pipe. Can save still images and video to a memory card. Video out function.<br />

Wohler VIS250 Service Camera<br />

Visual Inspection System<br />

WOH,VIS250-S CAMERA (5116)<br />

AU<br />

Compact colour video pipeline inspection system, 26mm<br />

colour camera with bright white LED’s on 30m of flexible<br />

push rod with metric marking. Camera sensitivity 3Lux, lens<br />

f=2.5mm, F=2.0, view angle 120°, waterproof to 3m water<br />

depth. Suitable for insertion in pipes and spaces from 40<br />

to 150mm diameter. Supplied with 2 battery packs and an AC charger/power pack,<br />

each battery pack lasts approx 1.5h. Supplied with 5.6” TFT display with extension<br />

cable, video output suitable for video recorder (not supplied).<br />

Wohler VIS340-PT Service Camera Visual inspection System<br />

WOH,VIS340-PT (5117)<br />

AU<br />

Compact colour video inspection system with 26mm forward facing and 40mm Pan<br />

Tilt colour cameras. Viewing angle 120°, waterproof according to IP68 and IP67<br />

respectively. Bright white LEDs on 30m of flexible push rod with metric markings.<br />

Battery powered 7” high resolution colour screen with removable monitor and SD<br />

video recording. Applications incl damage analysis in water / drainage / sewer pipes,<br />

inspection of hollow spaces, ventilation, machines, control panels, exhaust systems<br />

and production surveillance.<br />

Material Moisture Meters<br />

Vivax Pipeline Camera Inspection<br />

System<br />

VIV,VCAM-60M (5110)<br />

AU<br />

60 meter pipeline inspection system with self leveling<br />

camera (D33/SL, 41mm diameter) will record MPEG4<br />

videos and provides a keyboard, titler and sound<br />

system to add up to 16 pages of text and an audio<br />

commentary. Can be uploaded via a USB interface<br />

to a computer allowing copies to be made or images to<br />

be captured for inclusion in reports. Camera includes<br />

a sonde with 512Hz, 640Hz and 33kHz modes.<br />

Vivax Pipeline<br />

Camera Inspection<br />

System<br />

VIV,VCAM-120M (5149)<br />

AU<br />

120 meter pipeline inspection system with self<br />

leveling camera. Will record MPEG4 videos and<br />

provides a keyboard, titler and sound system to add<br />

up to 16 pages of text and an audio commentary.<br />

Can be uploaded via a USB interface to a computer<br />

allowing copies to be made or images to be captured<br />

for inclusion in reports. Camera includes a sonde with<br />

512Hz, 640Hz and 33kHz modes.<br />

66<br />

See also Concrete Testing Equipment: PRO,MMS-PLUS on page 64<br />

Protimeter SM Moisture Meter<br />

PRO,SM (4954)<br />

AU<br />

Moisture meter for survey work. Very good for determining wet points. Will<br />

provide % moisture content for timber. Subsequent accurate measurements<br />

can then be made.<br />

Distance Measurement & Surveying<br />

See also Light Meters, UVA/B/C Measurement on page 73<br />

ikeGPS Precision GPS and Laser<br />

Distance and Camera System<br />

IKE,300PRO (5301)<br />

AU<br />

Intergrated precision GPS (1.5m), laser based<br />

range finder (300m), Precision compass, precision<br />

inclinometer and camera system. Used to geolocate and document. It can<br />

be used to remotely dimension cable and buildings, etc.<br />

Solmetric Suneye 210 Shade Analysis Tool<br />

SOL,SUNEYE210 (5350)<br />

AU<br />

Integrated Shade Analysis Tool for solar site<br />

assessment. Includes a fisheye lens on a digital camera<br />

and a dedicated on-board processor to perform digital<br />

image processing and analysis to compute shading and<br />

solar access percentages. Includes an electronic compass<br />

and level, and an inclinometer function for measuring<br />

roof pitch and azimuth. Also includes a GPS system to<br />

accurately determine latitude and longitude.


www.techrentals.com.au<br />

Environmental, OHS, Chemical & Laboratory<br />

Environmental Gas & Vapour Meters<br />

Personal Gas & Vapour Monitors<br />

Airborne Dust & Particle Meters<br />

Air Quality & Heat Stress<br />

Moisture & Humidity Meters<br />

Noise & Sound Analysers<br />

Radiation Monitoring & Protection<br />

Floor Slip Testers<br />

Water Quality, pH Meters & Eletrochem<br />

Light Meters, UVA/B/C Measurement<br />

Weather Stations<br />

Environmental Flow Meters<br />

Laboratory & Hand-held Microscopes<br />

Balances & Scales below 8kg<br />

Chemical & Analytical - General<br />

Laboratory Instruments, Spectroscopy<br />

Environmental Gas & Vapour Meters<br />

See also Combustion, Flue & Industrial Gas Analysers on page 55<br />

Aeroqual 500L Portable Logging Ozone Monitor<br />

AER,500L (5958)<br />

AU<br />

Portable ozone monitor fitted with low concentrationrange<br />

detection head. Operating range 0 to 0.5ppm<br />

ozone with display in ppm or mg/m 3 . Gas sensitive<br />

semiconductor [GSS] sensor for accurate low-level<br />

measurements, T90 response approximately 100s.<br />

Operation from mains power supply or battery pack<br />

(4h operation). Internal data logging for 8,000 points<br />

with software and cable for download to PC, or data<br />

logging direct to PC. Application for indoor air quality<br />

measurements.<br />

Odalog ODA6000CP NO2 & CO Area Monitor for Vehicle-parks & IAQ<br />

APT,ODA6000CP (5972)<br />

AU<br />

Portable multi-gas monitor for area air-quality measurement, logging or<br />

personal monitoring in car-parks, loading areas and related zones. Configured<br />

for carbon monoxide (from petrol vehicles) and nitrogen dioxide (from diesel<br />

vehicles). Ranges CO 0 to 500ppm (to 1ppm) and NO 2<br />

0 to 50ppm (to 0.1ppm).<br />

Dust and water sealed to IP66, and rated intrinsically safe for general or mines<br />

use. Logging memory 500K readings. Integral infrared communications<br />

interface, with software and IrDA USB adaptor for configuration and download.<br />

Rechargeable, approximately 7 days operation on full charge.<br />

Geotech Landfill Gas<br />

ExMonitor<br />

GEO,GEM5000 (5940) AU<br />

Measures CH 4<br />

, CO 2<br />

, O 2<br />

, CO & H 2<br />

S. Designed for spot<br />

measurements. Intrinsically safe and has a built in<br />

GPS system. It can also measure flow rates from bore<br />

holes and perform landfill gas energy calculations.<br />

Environmental Gas & Vapour Meters<br />

cont’d.<br />

Haloteck 78000 Refrigerant Gas Leak Detector<br />

HAL,78000 (5804)<br />

AU<br />

For use by refrigeration engineers. Rapid response 0.2s, audio output,<br />

zero warm up time. Single control, battery operated, sensor tip insensitive<br />

to draughts. Sensitivity better than 3g/y R12, 25g/y R134A. Responds to<br />

halogenated hydrocarbons and many fire extinguishant gases, [also sulphur<br />

hexafluoride SF6]. Battery life 30h. Duty cycle continuous. Probe length<br />

240mm. Weight 280g.<br />

GasCheck 3000 Portable General-Purpose Leak Detector<br />

ION,GASCHECK3000 (5906)<br />

AU<br />

Micro thermal-conductivity sensor for high-sensitivity detection of gases with<br />

a thermal conductivity different to that of air, including helium, carbon dioxide,<br />

refrigerants, sulphur hexafluoride, natural gas, etc in 5 groups. Direct reading<br />

of leak rate in ml/sec with audio and visible signals. Detection limit for helium<br />

2E-5ml/s. Battery Powered.<br />

Ion Science Gascheck Helium, Butane & SF6<br />

Detector<br />

ION,GASCHECKG3 (5907)<br />

AU/MY<br />

Microthermal conductivity gas detector. Reading in<br />

cc/s, g/yr, mg/m 3 or ppm. Detects most gases however<br />

particularly suited to ammonia, argon, butane, helium,<br />

hydrogen & SF6. Calibrated against Helium. Battery<br />

Life 40h. Sensitivity (cc/s) He 1x10-5, CH4 5x10-5,<br />

R12 5x10-5, Ar 1x10-4. Accuracy 5% of displayed<br />

reading + 1 digit. Response 1s. Flow rate 2cc/min. Operating -20 to 60°C.<br />

Data logging, stores 10 readings.<br />

ISC MDU420 Logging Methane Monitor<br />

ISC,MDU420 (5956)<br />

AU<br />

Dual-range methane monitor with non-dispersive infrared sensor. Low range<br />

0 to 100% LEL, and auto-range 0 to 100% methane by volume. Internal pump<br />

for ambient air or stream sampling. Data logging included, with software and<br />

cable for download. Supplied with 450mm stainless steel probe for flue gas<br />

analysis. Rechargeable, with alkaline-battery pack as backup.<br />

Oldham MX21 Plus Gas Monitor for Sulphur Dioxide SO 2<br />

OLD,MX21-SO2 (5927)<br />

AU<br />

Portable gas detector for personal, workplace or space monitoring of sulphur<br />

dioxide (SO 2<br />

) in the range 0 to 30ppm. Operation in passive or pumped modes,<br />

with sampling tube and flexible probe. Data logging, with software included for<br />

download to serial printer or computer. Rolling storage of up to 48h data (at<br />

1min intervals) in multiple groups. Rechargeable battery.<br />

Photovac 2020 Portable PID VOC Monitor<br />

PHO,2020PRO (5950)<br />

AU<br />

Portable handheld VOC (Volatile Organic Compound) monitor with data<br />

logging. PID sensor (Photo-Ionisation Detector) fitted with 10.6eV lamp.<br />

Ranges 0.5~2000ppm humidity compensated. <strong>Download</strong>able data logging for<br />

15,000 points with time, data and header. Intrinsically safe.<br />

PPM 400 Portable Formaldehyde Meter<br />

PPM,FORM400 (5962)<br />

AU<br />

Portable Formaldehyde meter for measuring<br />

airborne formaldehyde in the workplace.<br />

Electrochemical sensor, with internal pump<br />

for rapid response. Operating range 0.05 to<br />

10ppm with readout on 4 digit LCD display.<br />

Kit includes field calibration standard.<br />

Operates from 9V alkaline battery.<br />

67


Environmental, OHS, Chemical & Laboratory<br />

www.techrentals.com.au<br />

Environmental Gas & Vapour Meters<br />

cont’d.<br />

RAE Systems Minirae 2000 Portable PID<br />

RAE,MR2000 (5950)<br />

AU<br />

Portable handheld VOC (Volatile Organic<br />

Compound) monitor with data logging. 3-D PID sensor (Photo-<br />

Ionisation Detector) fitted with 10.6eV lamp. Ranges 0 to<br />

999ppm (resolution 0.1) or 100 to 10,000ppm (resolution 1)<br />

VOC expressed as isobutylene. Built-in correction factors for<br />

102 compounds from a total standard library of 250. Integrated<br />

pump for local or remote (30m) sampling, with stall protection<br />

against liquid ingress. <strong>Download</strong>able data logging for 1,500<br />

points with time, data and header. Intrinsically safe. Up to 10h<br />

operation with rechargeable (NiMH) or alkaline batteries.<br />

Minirae 3000 Advance Handheld VOC Monitor<br />

RAE,MR3000<br />

MY<br />

Handheld volatile organic compound (VOC) detector.<br />

Photoionization Detector’s (PID) extended range of 0 to<br />

15,000 ppm, ideal For applications from industrial hygiene,<br />

to leak and HazMat detection. RF modem allows real-time<br />

data transmissions with a base controller located up to 500<br />

feet (or two-miles with optional RAELink3 portable modem)<br />

away from the MiniRAE 3000 detector. A personal computer<br />

can be used as the base station for a Mini-RAE 3000 system.<br />

RH Systems<br />

973-SF6<br />

Analyser<br />

RH,973-SF6 (5910)<br />

AU<br />

Measures the purity of SF6 gas. Uses<br />

a fast acting mirror system to measure<br />

humidity. Displays direct % purity.<br />

Includes a gas recovery system. Includes built in test for instant verification<br />

of the system accuracy. Dew Point measurement -55 to 20°C, pressure<br />

0.1~30bar. Accuracy ±0.5° dew point. Gas coupling is done via a quick<br />

connect fitting.<br />

Wika GA-15 SF6<br />

Leak Detector<br />

WIK,GA-15 (5909)<br />

AU<br />

A fast response SF6 leak detector which<br />

will detect concentrations of SF6 down to<br />

3ppmv. Only detects SF6 and is unaffected<br />

by moisture and wind.<br />

Personal Gas & Vapour Monitors<br />

BW Bump & Logging <strong>Download</strong> for<br />

BW,MICROCLIP<br />

BW,BUMP (5938)<br />

AU/MY<br />

Automatic calibration testing and data management<br />

system for the BW microclip gas detection equipment.<br />

Carries out fully automatic “hands-free” calibration and<br />

functional bump test. It also enables data collected<br />

during operation of the BW microclip to be downloaded.<br />

Personal Gas & Vapour Monitors<br />

cont’d.<br />

BW Gas Alert Micro Clip Confined Space 4 Gas<br />

Detector<br />

BW,MICROCLIP (5937)<br />

AU/MY<br />

Continuous LCD shows real time gas concentrations.<br />

Simple 1 button operation. Measures:- H 2<br />

S 0 to<br />

100ppm (1ppm resolution), CO 0 to 500ppm (1ppm<br />

resolution), O 2<br />

0 to 30% (0.1% resolution) and<br />

Combustible gases 0 to 100% LEL (1% resolution),<br />

0 to 5% v/v (0.1% resolution). Alarms: visual, vibrating and audible (95dB),<br />

Low, High, STEL, TWA and OL (over limit). Lithium polymer battery life 12hrs<br />

(typical) recharge time


www.techrentals.com.au<br />

Environmental, OHS, Chemical & Laboratory<br />

Airborne Dust & Particle Meters cont’d.<br />

TSI Environmental Enclosure for the TSI,8530<br />

TSI,8530-ENC (5875)<br />

AU/MY<br />

Enclosure to suit the TSI,8530. Includes two additional<br />

batteries and charger. Includes waterproof enclosure and<br />

heat shield and enclosure stand.<br />

TSI Environmental Enclosure for the TSI,8530 Dusttrak II<br />

TSI,8530-ENC-S (5876)<br />

AU<br />

Enclosure to suit the TSI,8530. Includes two additional batteries and<br />

charger. Includes waterproof enclosure.<br />

TSI 8533 Aerosol Monitor and Logger<br />

TSI,8533 (5870)<br />

AU<br />

Portable dust and particle monitor, light scatter photometer.<br />

Measure concentrations corresponding to PM1, PM2.5 and PM10. Aerosol<br />

concentrations .001 to 150mg/m3. Used for industrial/occupational hygiene<br />

surveys, indoor air quality monitoring, outdoor environmental monitoring,<br />

baseline trending and screening etc. Will size particles in three sizes PM1,<br />

PM2.5 and PM10.<br />

TSI AM510 Personal Aerosol Monitor;<br />

CSA & ATEX IS approvals<br />

TSI,AM510 (5871)<br />

AU<br />

Wearable dust monitor. Built in Impator allows<br />

you to chose either ‘none’, 1, 2.5 or 10μm particle<br />

sizes. Datalogs TWA in the range of particle<br />

concentrations from .001 to 20mg/m 3 Runs 9.2hrs<br />

on rechargeable NiMH batteries. USB download<br />

capability. CSA & ATEX IS approvals.<br />

Air Quality & Heat Stress<br />

Casella Microtherm WBGT<br />

Area Heat Stress Monitor<br />

CAS,MICROTHERM (5868)<br />

AU<br />

Portable area heat stress WBGT monitor with<br />

real-time graphical display. Measures heat<br />

stress potential [WBGT index] according to<br />

ISO7243. PRTD sensors with internal calibrationreference<br />

for wet-bulb, dry-bulb and globe temperatures. Large LCD display<br />

for numerical or graphical indication of temperatures and processed values<br />

for WBGT [indoor/outdoor plus TWA], relative humidity and dewpoint. Simple<br />

keypad/menu setup. Data logging for up to 32 separate runs and 49,100<br />

records, with interval 30s to 1h. RS232C port with included PC software for<br />

download and reporting or realtime display. Low water-level warning, and<br />

settable audible/visible WBGT alarm. Handheld, free-standing or tripodmount.<br />

Battery operated.<br />

Testo 635-2 Humidity, Temperature & Dewpoint Meter<br />

TES,635-2 (5859)<br />

AU<br />

Portable humidity meter fitted with robust stainless probe<br />

with sintered filter-cap for general or duct measurements to<br />

120ºC, and fast-action K-type surface temperature probe.<br />

Displays relative humidity, absolute humidity, dew point,<br />

degree of humidity, enthalpy, temperature, and differential<br />

temperature (dewpoint to surface). Operating range 2 to<br />

98%RH (±2%). Air temperature -20 to 120ºC (±0.2/0.5).<br />

Surface temperature -60 to 300ºC (±0.1). Internal memory<br />

for 10,000 values with USB interface, cable and software for<br />

download and presentation. Battery operated.<br />

Air Quality & Heat Stress cont’d.<br />

Testo 645 Humidity & Dewpoint Meter<br />

TES,645-1 (5858)<br />

AU<br />

Portable humidity meter fitted with robust stainless<br />

probe for ambient work or duct measurements<br />

to 120°C. Displays relative humidity, absolute<br />

humidity, dew point, degree of humidity, enthalpy<br />

and temperature. Operating range 2 to 98%RH<br />

[±2%], -20 to 120°C [±0.4/0.5]. Battery operated.<br />

TSI Q-TRAK IAQ Monitor CO 2<br />

,<br />

CO Temperature & Humidity Logger<br />

TSI,7565 (5861)<br />

AU<br />

Measures CO 2<br />

0 to 5,000ppm ±3%, temperature<br />

0 to 60ºC ±0.6ºC, humidity 0 to 95% ±3%, CO 0<br />

to 500ppm ±3% and barometric pressure 517.15 to<br />

930.87mmHg ±2%. Calculates dew point, wet bulb<br />

and percent outside air. Displays 5 measurements<br />

simultaneously. User selectable logging interval and<br />

start stop times. Stores 39 days data at 1min intervals<br />

56,035 data points. This unit also has external<br />

thermocouple measurements.<br />

TSI Q-Trak plus Indoor Air Quality Monitor<br />

with Logging<br />

TSI,8554 (5860)<br />

AU/MY<br />

Indoor air quality (IAQ) monitor for temperature<br />

and humidity measurements, CO and CO 2<br />

concentrations. Humidity range 0 to 95%,<br />

temperature range 0 to 50°C. Electrochemical<br />

cell for CO 0 to 500ppm. NDIR cell for CO 2<br />

0 to<br />

5,000ppm. Data logging for 48,671 data points<br />

with interval adjustable 1s to 1h. Fitted with RS232<br />

interface, and software included for download,<br />

storage and reporting. Battery or mains operation<br />

with AC adaptor.<br />

Moisture & Humidity Meters<br />

GE Panametrics PM880 Industrial<br />

Moisture Analyser<br />

PAN,PM880 (5911)<br />

AU<br />

Intrinsically safe moisture analyser for<br />

compressed air systems, non-corrosive gases &<br />

hydrocarbons such as natural gas (IS certification<br />

to ATEX and CSA). Displays dew point, moisture<br />

concentration, pressure & temperature. Dew point<br />

calibrated measurement range -80 to 20°C with<br />

data to -110°C. Pressure range 7 to 69bar limited<br />

by sensor, gauge and safety-valve (operating range from 5μHg). Temperature<br />

range -30 to 70°C. Gas flow operating range from static to 10,000cm/s velocity.<br />

Supplied with compact sample system with gauge, safety-valve, sampling<br />

valves and fittings (¼” Swagelok). Data logging of up to 100K moisture points,<br />

with infrared port and software for download. Battery powered only (15-24h<br />

operation) with second battery and charger (note charger is not IS).<br />

69


Environmental, OHS, Chemical & Laboratory<br />

www.techrentals.com.au<br />

Noise & Sound Analysers<br />

See also Vibration Analysis on page 60-61<br />

ARL EL-315 Environmental Noise Logger<br />

ARL,EL-315 (5694)<br />

MY<br />

Portable, self-contained and weatherproof with display<br />

for field reading of summary results. Continuous<br />

90dB dynamic range, frequency weightings A and C.<br />

Monitors environmental noise continuously for up to<br />

3 weeks, calculates and stores over 7,500 sets of Ln<br />

indices. PC required to set up system and download<br />

data using software supplied. Set up also possible<br />

from front-panel.<br />

ARL EL-316 Environmental Noise<br />

Logger Type 1<br />

ARL,EL-316 (5695)<br />

AU<br />

Environmental noise logger with display for fieldreading<br />

of summary results. Portable, self-contained<br />

and weatherproof. Type 1 performance, continuous<br />

90dB dynamic range, fast response, frequency<br />

weightings A and C. Monitors environmental noise<br />

continuously for up to 3 weeks, calculates and stores<br />

over 7,500 sets of Ln indices. PC required to set up<br />

system and download data using software supplied.<br />

Set up also possible from front-panel.<br />

ARL NGARA Environmental Noise Logger<br />

ARL,NGARA (5690)<br />

AU<br />

Can be configured to record all sound continuously<br />

so noise data can be post processed. It can prove<br />

logged data, WAV data & alarm/triggered details.<br />

Type 1 microphone provided.<br />

B&K 2237A Type 2 Integrating Sound Level Meter<br />

BK,2237A (5661)<br />

AU<br />

Measures RMS and peak simultaneously. Linearly weighted<br />

analogue output for sound recording, 0 to 0.5VAC (RMS). Measurement<br />

range 30 to 140dB. Time weightings fast, slow & impulse. Independent<br />

frequency weightings A [for RMS readings SPL, MaxL, MinL, Leq, Inst] and<br />

C [for peak readings Peak and MaxP]. Real time clock for time and date<br />

stamp. Records 40 measurements for download to PC. Calibrator included.<br />

Battery operated.<br />

B&K 2238E Type 1 Integrating SLM Enhanced<br />

Software & Logging<br />

BK,2238E-NATA (5678)<br />

AU<br />

Type 1 (class 1) Integrating sound level meter with additional functions<br />

including enhanced software, frequency analysis and data logging.<br />

Standard routines include functions for workplace measurements<br />

and general sound-level checks; enhanced software (firmware) offers<br />

additional measurements and statistics for assessment of environmental<br />

noise problems; frequency analysis automates measurements in the<br />

9 single octave bands and 29 1/3 octave bands. Supplied with field<br />

calibrator. Compatible with BK,7815 Noise Explorer Environmental<br />

software for download, data analysis and display.<br />

B&K 2239A Type 1 Sound Level Meter NATA Certification<br />

BK,2239A-NATA (5667)<br />

AU<br />

Type 1 (class 1) integrating sound level meter with backlit LCD<br />

display, NATA certification. Simultaneous RMS (A,C) & peak (C) detection<br />

with independent frequency weightings. Measuring range 30 to 140dB.<br />

Time weightings fast, slow and impulse. Parameters Leq, MaxP, MaxL,<br />

MinL, Peak, SPL and Inst. Memory for 40 data records with realtime clock.<br />

Serial port for data download. Calibrator included. Operates with 4 x AA<br />

alkaline batteries.<br />

Noise & Sound Analysers cont’d.<br />

B&K 4448 Badge Dose Meter IS Kit of 3<br />

BK,4448-IS-3KIT (5680)<br />

AU<br />

Kit of 3 Intrinsically safe noise dose meters. The kit includes a<br />

NATA calibrated 4231 Type 1 calibrator. These are badge type Dose Meters,<br />

shoulder mounted, cable free and simultaneously measure all parameters<br />

required by noise at work standards. Simple two button operation.<br />

Rechargeable battery provides several working days of measurement.<br />

Ivie IE-35 Type 1 Audio Analysis Systems<br />

IVI,IE35-2P (5682)<br />

AU<br />

Audio Analyser with Dell Axim X51v PDA. Fitted with<br />

half-inch free-field Type 1 microphone and pre-amplifier.<br />

Functions include SPL (sound level), Real-time analysis,<br />

“seat-to-seat” variation for audio setup, reverberation<br />

measurement, “strip-chart” recording on display, voltage<br />

and oscilloscope displays and signal generation. Supplied<br />

with field-calibrator, microphone extension cable, spare<br />

battery and software for data-download to PC. SPL<br />

facilities include time and frequency weightings - fast,<br />

slow, peak or impulse and A, C or Flat. FFT based Real<br />

Time Analysis includes 1/1, 1/3, or 1/6 octave bands with<br />

a maximum resolution of about 1/24 octave. Additional<br />

functions include spectrum subtraction, averaging, Noise Critera or Reduction<br />

contours and reverberation-decay to ISO-20 and ISO-30. Signal-generation<br />

includes sine, square, triangle and white or pink noise.<br />

Digital Audio Test Set comprising of NTI<br />

Digirator & NTI Digilyser<br />

NTI,NT-DAS (5684)<br />

AU<br />

Audio Excel Line for digital audio signals. System<br />

including the Digilyzer and Digirator for producing<br />

digital audio signals and analysing those digital<br />

audio signals up to and including 5.1 surround<br />

sound. Up to 192kHz 24bit, AES3,S/PDIF, TOSLINK<br />

& ADAT. ync input (AES3, Word Clock, Video). Supports Dolby Digial, E,<br />

PL II, DTS. Channel transparency check. Channel delay measurement.<br />

NTI XL2+M2210<br />

Sound Level Meter<br />

NTI,XL2+M2210<br />

MY<br />

Sound Level Meter comes with Class 1<br />

microphone, acoustical analyser options and<br />

audio analyser options. Applications in sound<br />

installations, live sound, studio, broadcast and<br />

environmental noise measurements. Logging<br />

all data or subsets in selectable intervals.<br />

Recording of wav-files (ADPCM), a new<br />

wav-file starts every 12 hours (max. wav-file<br />

size 512 MB). Real time analyzer with frequency resolution: 1/3 octave,<br />

1/1 octave, wide band and frequency range: 6.3Hz to 20kHz. Frequency<br />

weighting: A, C, Z. USB interface with PC analysis tool.<br />

Quest 2400 Type 2 Sound Level Meter<br />

QUE,2400 (5660)<br />

AU<br />

Type 2 sound level meter with LCD display for sound pressure level [SPL]<br />

or maximum level [MAX]. Frequency weightings A and C, time weightings<br />

Fast and Slow. Ranges 30 to 140dBA and 40 to 140dBC with overload<br />

indication. AC and DC outputs. Battery powered.<br />

70


www.techrentals.com.au<br />

Environmental, OHS, Chemical & Laboratory<br />

Noise & Sound Analysers cont’d.<br />

Rion NL-04 Sound Level Meter<br />

RIO,NL-04<br />

MY<br />

Meets IEC type 2. Five measurement functions: Lp(SPL), Leq, LAE, Lmax<br />

& Lx(L5,L10,L50,L90,L95). 6 automatic measurements & data store. Built-in<br />

RS232C interface for computer communication. 70dB dynamic range (digital<br />

display), 27 to 130dB (A) measuring range. Wide range of time settings for<br />

Leq, LAE, Lmax & Lx; 10s, 1, 5, 10, 15, 30min, 1, 8, 24h & manual time<br />

setting (up to 99h 59min 59s). RMS: fast, slow,10ms. 4 digit LCD display,<br />

0.1dB resolution, updated every second, plus 60dB analogue display display<br />

1dB resolution showing the instantaneous value. Memory battery back-up.<br />

AC & DC signal o/p for level expanding system by optional filters, memory<br />

card & others.<br />

Rion NL-05 Type 2 Sound Level Meter<br />

RIO,NL-05 (5664)<br />

AU<br />

Sound level meter to IEC 651/1979 & IEC 804/1985 type 2 requirements.<br />

Measures Lp, Lmax, Leq, Lae. Response types A, C, and flat. Fast and slow<br />

time weightings. Complete with calibrator. Internal memory and print-out<br />

for Leq data (printer CP-10 optional, also prints other parameters), RS232C<br />

interface. Recorder outputs 1VAC RMS & 3.5VDC. Operates from batteries<br />

or AC adaptor.<br />

Rion NL-32 SLM with RTA & NATA Certification<br />

RIO,NL-32RTA-NATA (5674)<br />

AU<br />

RIO,NL-32RTA<br />

MY<br />

Precision integrating sound level meter to IEC type 1<br />

(class 1) specification, with NATA calibration. Fitted with<br />

internal Compact Flash Card reader and supplied with<br />

NC-74 field calibrator. Frequency range 20 to 20,000Hz<br />

with weightings A, C, and flat. Time weightings fast,<br />

slow and impulse. Measurement range (A) 28 to 138dB.<br />

Broadband measurement functions Lp (SPL), Leq,<br />

Lmax/min, Lae, Lx, and selectable auxiliary functions<br />

with manual or auto storage [logging]. Measurement time (Leq) from 10s to<br />

200h. Inbuilt memory for up to 100 data sets, or to limit of fitted CF card using<br />

manual or auto storage. AC or DC outputs, RS232C interface and cable CC-<br />

93 for serial printer. Supplied with NX-22RT card for real time 1/1 and 1/3<br />

octave analysis and display, for measurement functions Lp, Leq, LE, Lmax<br />

and display of AP (all-pass) AP(A) and 1/1 or 1/3 octave values as selected,<br />

with manual data storage only to NX-22RT card. <strong>Download</strong> of card-data to PC<br />

requires flashcard reader. Alkaline batteries (24h operation) or AC adaptor.<br />

Radiation Monitoring & Protection<br />

See also E & H Field Strength Meters on page 11<br />

Fluke 481 Radiation Survey Meter<br />

FLU,481 (5580)<br />

AU<br />

Provides exposure measurements in mR/hr to 50R/h<br />

(0.55v/hr). Detects skin-dose, deep-dose and X-ray<br />

radiation. Measures dose & dose rate.<br />

HPI Cypher 5000 Digital Radiation Alert<br />

Monitor<br />

HPI,CYPHER5000<br />

AU<br />

Alpha, Beta, Gamma and X-ray radiation monitor.<br />

Meter, LED, audible indication and detachable<br />

probe. Range 0.1 to 1,000,000 CPM; Accuracy<br />

1% or 2 digits.<br />

Radiation Monitoring & Protection<br />

cont’d.<br />

Narda RadMan Personal RF Field Radiation Monitor<br />

NAR,RADMAN (5557)<br />

AU<br />

Personal monitor and leakage detector for high frequency<br />

electromagnetic fields. Simultaneous E and H field<br />

measurements with audible and visual alarms. Frequency<br />

range H field 27MHz to 1GHz; E field 1MHz to 40GHz.<br />

Operation as personal monitor with compensation for<br />

human body absorption, or with isotropic detection for RF<br />

leakage sensing and simple four-level measurement using<br />

LED indicators. Battery powered. Battery life over 200h.<br />

Floor Slip Testers<br />

Severn Model Tortus II<br />

Floor Slip Tester<br />

SEV,TORTUSII (5505)<br />

AU<br />

Floor friction tester. Measures and<br />

records the dynamic coefficient of<br />

friction. Applications in assessing floor<br />

safety, evaluating cleaning methods<br />

and maintenance procedures, accident investigation, etc. Meets the draft<br />

requirements of international, Australian and New Zealand standards.<br />

Water Quality, pH Meters<br />

& Electrochem<br />

DKK TOA Model RC-24P Portable Residual<br />

Chlorine Meter<br />

DKK,RC-24P-DP (6046)<br />

AU<br />

Portable, direct-reading residual chlorine meter<br />

for water analysis. Range 0 to 2mg/L [ppm].<br />

Reagent-free measurement with electrode,<br />

3m cable, float and sample container for insitu<br />

or grab-sampling. Compatible with direct<br />

chlorination, hypochlorite or dichloroisocyanurate<br />

dosing. Calibration data stored in electrode with<br />

correlation with DPD methods. Waterproof to<br />

IP67. ISO validation functions, storage of 300<br />

measurements and RS232 printer output. Battery<br />

operated.<br />

Horiba U-52 Multi-function Water Quality Meter<br />

HOR,U-52-10M (6025)<br />

AU<br />

Measures pH range 0 to 14pH, resolution 0.01, accuracy ±0.1. Oxidation<br />

reduction potential (ORP) range -2,000mV to 2,000mV, resolution 1mV,<br />

accuracy ±15mV. Dissolved oxygen (DO) range 0 to 50mg/l, resolution 0.01,<br />

accuracy 0 to 20mg/l ±0.2 and 20 to 50mg/l ±0.5. Conductivity range 0 to<br />

100mS/cm, resolution 0.001 to 0.1 depending on scale, accuracy ±1%F.S.<br />

Salinity range 0 to 70ppt, resolution 0.1, accuracy ±3ppt. Total dissolved solids<br />

(TDS) range 0 to 100g/l, resolution 0.1%F.S., accuracy ±5. Seawater specific<br />

gravity range 0 to 50 sigma t, resolution 0.1, accuracy ±5. Temperature<br />

range -5 to 55ºC, resolution 0.01, Turbidity (Turb) 0 to 800NTU, resolution<br />

0.1, accuracy ±5% (reading) or ±1NTU whichever is the greater. The probe<br />

diameter is 96mm the cable length is 10m.<br />

Narda 8217 Microwave Oven Survey Meter<br />

NAR,8217 (5553)<br />

AU<br />

For oven power measurement complete with beaker and thermometer.<br />

Calibration frequency 2.45GHz. Measurement range 0.5 to 10mW/cm 2 .<br />

Battery operated.<br />

71


Environmental, OHS, Chemical & Laboratory<br />

www.techrentals.com.au<br />

Water Quality, pH Meters<br />

& Electrochem cont’d.<br />

Hydrolab Minisonde 5 Multiprobe<br />

Water Logger<br />

HYD,MS5 (6020)<br />

AU<br />

Miniosonde 5 multiprobe water/borehole logger,<br />

including ‘Surveyor’ data collection system with<br />

GPS. Includes sensors for Dissolved Oxygen<br />

(HACH LDO), Conductivity, pH, Redox (ORP),<br />

Turbidity (Self-Cleaning), Temperature, Depth (0<br />

to 25m) and GPS position. Includes the surveyor<br />

data aquisition system so no laptop is needed for<br />

download or data collection. Includes a 25m cable.<br />

ISCO 6700 Series Water Sampler<br />

ISCO,6712 (6057)<br />

AU<br />

Advanced water sampler for fully programmed<br />

collection. Samples are collected in up to 24<br />

disposable plastic containers based on time, flow,<br />

and/or parameter set points. Fitted with NEMA 4X,6<br />

(IP67) sealed controller featuring an exclusive,<br />

built-in pump.<br />

Isco 6700 Series Water Sampler with Bubbler<br />

Flow Module<br />

ISK,6700-730 (6056)<br />

AU<br />

Advanced water sampler for fully programmed<br />

collection. Samples can be collected in 1, 2, 8, or 24,<br />

1 litre disposable sample containers based on time,<br />

flow, and/or parameter set points. Fitted with NEMA<br />

4X,6 (IP67) sealed controller featuring an exclusive,<br />

built-in pump, flash memory for easy programming<br />

changes, and a plug-in module port for connection of a flow meter module or<br />

parameter measurement module to enhance monitoring capabilities. Provided<br />

with bubbler flow module. Sample bottles available. Run from rechargeable<br />

12V sealed batteries.<br />

OTT KL010-150 Ground-water Depth Measurement Contact Gauge 150m<br />

OTT,KL010-150 (6065)<br />

AU<br />

Contact gauge for portable depth to water measurement. Used for wells,<br />

observation pipes, bore holes and control pumping tests. 150m depth of tape.<br />

as soon as the probe touches the water surface an acoustic signal beeps and<br />

the lamp on the instrument lights up. The depth is read from the measuring<br />

tape in meters.<br />

Solinist Oil/Water Interface Meter<br />

SOL,122 (6066)<br />

AU<br />

Used for bore determination of LNAPL or DNAPL levels. Flat tape on a reel<br />

when lowered down a bore hole a light and tone indicate the LNAPL (Light<br />

Non-Aqueous Phase Liquid) layer or the DNAPL (Dense Non-Aqueous Phase<br />

Liquid) level. The level is measured from the 50m tape.<br />

TPS 90FL-T Water Quality Meter<br />

TPS,90FL-T (6028)<br />

AU<br />

Field meter and logger for water<br />

quality measurements. Configured with<br />

independent probes for pH, conductivity/<br />

salinity[TDS]/temperature,<br />

dissolved<br />

oxygen[DO] and turbidity. Cables 5m with<br />

probe holder and safety harness. LCD display<br />

readout with simultaneous display of all measurements. Manual, “notepad”<br />

storage or automated data logging for up to 1,808 sets of readings by time<br />

and date. RS232C interface, with WinTPS software included. Supplied with<br />

rechargeable battery, and clip-lead for operation from a 12V source such as<br />

a car-battery.<br />

Water Quality, pH Meters<br />

& Electrochem cont’d.<br />

TPS Conductivity Probe With Cell K=0.1<br />

TPS,LOW K PROBE ( 6016)<br />

AU<br />

Plastic-bodied conductivity and temperature sensor for WP series meters.<br />

With k=0.1 and automatic temperature compensation ATC. For precision<br />

measurement at low conductivity levels. Minimum range with WP-84 2 uS/cm<br />

to 2,000uS/cm. Temperature range -10 to 60°C. Fitted with 5m cable.<br />

TPS Redox Electrode<br />

TPS,REDOX (6004)<br />

AU<br />

Silver/chloride Redox electrode for use with TPS LC80A Ph meter. Supplied<br />

with 2 bottles of Zobell solution for calibration. 1:1 dilution gives approx.<br />

231mV.<br />

TPS WP-80 pH and Temperature<br />

Meter<br />

TPS,WP-80 (6003)<br />

AU<br />

Portable hand-held meter for pH, mV and<br />

temperature. Supplied with combination pH<br />

electrode and separate temperature sensor on<br />

1m cables. Operating ranges 0 to 14pH and<br />

-10 to 120ºC (automatic sensor recognition<br />

with auto pH correction 0 to 100ºC). Case water resistant to IP67, connectors<br />

to IP65. Menu driven, with alphanumeric display. Auto storage of time and date<br />

of last calibration for GLP. Memory for 2400 readings of data, time and date,<br />

for Notepad results collection, or for AutoLog with logging intervals between<br />

1s and 90h. Fitted with RS232C interface and supplied with downloadsoftware,<br />

charger and solutions. Rechargeable NiMH battery gives up to<br />

50h operation.<br />

TPS WP-80 pH and Temperature Meter<br />

for Testing Meat<br />

TPS,WP-80M (6002)<br />

AU<br />

Portable hand-held meter for pH, mV and temperature.<br />

The instrument is capable of applying Bendalls<br />

equation to the pH reading for Meat Standards Australia<br />

grading requirements. Supplied with combination pH<br />

electrode and separate temperature sensor on 1m<br />

cables. Operating ranges 0~14pH and -10~120ºC<br />

[automatic sensor recognition with auto pH correction 0~100ºC]. Case water<br />

resistant to IP67, connectors to IP65. Menu driven, with alphanumeric display.<br />

Auto storage of time and date of last calibration for GLP. Memory for 2400<br />

readings of data, time and date, for Notepad results collection, or for AutoLog<br />

with logging intervals between 1s and 90h. Fitted with RS232C interface and<br />

supplied with download-software, charger and solutions. Rechargeable NiMH<br />

battery gives up to 50h operation.<br />

TPS WP-82 Dissolved Oxygen<br />

Meter<br />

TPS,WP-82 (6009)<br />

AU<br />

Portable hand-held dissolved oxygen and<br />

temperature meter. Operating ranges 0<br />

to 20ppm, 0 to 240% saturation, 0 to 45%<br />

gaseous and ppm with salinity correction.<br />

temperature range -10 to 120°C. Case water<br />

resistant to IP67, connectors to IP65, with<br />

3m detachable cable and ED1 electrode.<br />

Menu driven, with alphanumeric display.<br />

Auto storage of time and date of last calibration for GLP. RS232C interface,<br />

and memory for 150 readings of data, time and date, for Notepad results<br />

collection, or for AutoLog results collection with logging intervals between<br />

1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied<br />

with download-software, charger and solutions.<br />

72


www.techrentals.com.au<br />

Environmental, OHS, Chemical & Laboratory<br />

Water Quality, pH Meters<br />

& Electrochem cont’d.<br />

Light Meters, UVA/B/C<br />

Measurement cont’d.<br />

TPS WP-84 Conductivity<br />

Salinity Temperature Meter<br />

TPS,WP-84 (6014)<br />

AU<br />

Portable hand-held meter for conductivity,<br />

TDS (Total Dissolved Solids) and<br />

temperature. Automatic range selection<br />

with 5 ranges. Case water resistant to IP67,<br />

connectors to IP65. Menu driven, with<br />

alphanumeric display for full-text prompting.<br />

Storage of time and date of last calibration for<br />

GLP. Memory for 150 readings of data, time and date, for Notepad results<br />

collection, or for AutoLog results collection with logging intervals between<br />

1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied<br />

with sensor (k=1), charger and solutions.<br />

TPS WP-88 Turbidity &<br />

Temperature Meter with<br />

8m Cable<br />

TPS,WP-88 (6031)<br />

AU<br />

Portable hand-held turbidity and<br />

temperature meter for field or laboratory<br />

use. Sensor probe diameter 45mm,<br />

with 8m cable. Turbidity ranging 0.1 to<br />

200/2,000NTU ±1NTU with autoselection.<br />

Temperature compensation and sensor<br />

range 0 to 60ºC ±0.1ºC. Case water resistant to IP67, connectors to IP65,<br />

with detachable cable and sensor. Menu driven, with alphanumeric display.<br />

Auto storage of time, date and results of last calibration for GLP. RS232C<br />

interface, and memory for 150 readings of data, time and date, for Notepad<br />

results collection, or for AutoLog results collection with logging intervals<br />

between 1min and 24h. Rechargeable NiMH battery gives up to 50h operation.<br />

Supplied with download-software, charger and calibration solutions.<br />

Van Essen DI502 Mini-Diver Borehole<br />

Level Logger & Barometer 20m<br />

VAN,DI502 (6061)<br />

AU<br />

Mini-diver borehole level logger 20m, 1cm<br />

accuracy. Kit includes barometric logger for<br />

atmospheric pressure compensation. Will<br />

also log temperature. Temperature range<br />

-20 to 80ºC. Accuracy 0.1ºC. Size 22 x<br />

90mm. Stores 24,000 measurements per parameter. Stainless steel housing<br />

barometric (l/c) logger for compensation. 10 year battery life.<br />

Light Meters, UVA/B/C<br />

Measurement<br />

Hioki 3423 Lux HiTester Digital<br />

Illuminance Meter<br />

HIO,3423 (5602)<br />

AU/MY<br />

Manual switching and autoranging.<br />

LCD display with 3½ digits (“1999”)<br />

for five measuring ranges to<br />

20/200/2,000lx in 1-count steps,<br />

20,000lx in 10-count steps and<br />

200,000lx in 100-count steps with accuracy ±4%. Response time in autorange<br />

mode 5s (2s in manual range mode). Autozero, hold and backlight function with<br />

delay for taking readings in low light. Input for AC power adaptor, connectingcable<br />

to allow separation of sensor unit and meter, and 200mVDC analogue<br />

output with cable. Battery powered.<br />

ILI 1400ABC Radiometer for UV<br />

Measurements<br />

ILI,1400ABC (5614)<br />

AU<br />

International Light model 1400<br />

radiometer with backlit LCD<br />

display, autozero and autoranging.<br />

Continuous reading with hold<br />

function, or integrated “dose”<br />

measurement up to 24h. Smart<br />

detectors with storage of units and detector-calibration data. Analogue recorder<br />

output. Mains adaptor or battery power. Supplied with three sensors: UV<br />

actinic hazard (UVC with B & A components matched to OSHA requirements),<br />

range 2.50e -7 to 2.50e -3 W/cm 2 eff. UVB + A (total “solar” radiation), range<br />

1.16e -7 to 4.07e -1 W/cm 2 . UVB, range 1.54e -6 to 1.54e -2 W/cm 2 .<br />

Minolta CL-200 Chroma Meter for Illuminance<br />

& Colour Measurement<br />

MIN,CL-200 (5610)<br />

AU<br />

Konica Minolta model CL-200 portable colour meter. LCD<br />

display for illuminance, tristimulus values, chromaticity,<br />

correlated colour temperature and colour difference.<br />

Illuminance range 0.1 to 99,990lx ±2%. Colour accuracy<br />

±0.002 [xy] or ±20°K [Tcp]. Fitted with RS232C interface.<br />

Battery powered, or AC adaptor.<br />

Topcon BM-9 Luminance Meter<br />

TOP,BM-9-2 (5611)<br />

AU<br />

Portable luminance meter with digital display. Field-of-view 5°, measurement<br />

acceptance angle 2°, with 10mm min spot diameter. Measuring distance<br />

0.35m to infinity. Silicon photodiode sensor with automatic or manual range<br />

selection. Measurement range 0.01 to 199,900cd/m 2 ±4% of reading. Built-in<br />

RS232C interface and analogue output. Battery powered.<br />

Topcon IM-2D Lux Meter NATA Certification<br />

TOP,IM-2D-NATA (5606)<br />

AU<br />

Digital illuminance meter with NATA certification.<br />

Measuring range from 0.1 to 19,999lx. Accuracy<br />

5%, ±1 digit. Autoranging with silicon sensor.<br />

Battery operated.<br />

Topcon IM-5 Lux Meter NATA Certification<br />

TOP,IM-5-NATA (5608)<br />

AU<br />

Digital wide-range illuminance meter with NATA certification. Measuring range<br />

0.01 to 199,000lx. Accuracy ±2% +1 digit. Autoranging with silicon sensor.<br />

Analogue output and RS232 interface. Battery operated.<br />

Yokogawa 51001 Lux Meter NATA Calibrated<br />

YEW,51001-NATA (5607)<br />

AU<br />

Digital illuminance meter with NATA certification. Measuring range from 0 to<br />

99.9/999/9,990/99,900/999,000lx . Accuracy 3,000lx<br />

6% ±1 digit. Autoranging with silicon sensor. Battery operated.<br />

Weather Stations<br />

Environdata DL20WSD WeatherMaster<br />

2000 Weather Station<br />

ENV,WM20 (5888)<br />

AU<br />

Measures air temperature -15 to 50°C ±0.2, relative<br />

humidity 10 to 90%RH ±5%, rainfall 0.2mm resolution.<br />

Wind speed starting threshold 1kph. Wind direction<br />

resolution 6°C ±3%. One spare input channel.<br />

Capable of storing up to 3mths of data. Includes<br />

RS232 interface and software for download. Mounts<br />

on star-picket. Solar-rechargeable batteries.<br />

73


Environmental, OHS, Chemical & Laboratory<br />

www.techrentals.com.au<br />

Weather Stations cont’d.<br />

Vaisala WXT520 Weather<br />

Station<br />

VAI,WXT520-KIT (5885)<br />

AU<br />

Completely solid state measurement of rainfall<br />

to 0.1mm, rain intensity 0.1mm/hr, rainfall<br />

duration, hail duration and intensity, barometric<br />

pressure 600 to 1100hPa, relative humidity 0 to<br />

100%, wind speed 0 to 60m/s, wind direction<br />

and temperature -52 to 60°C. The information is logged to a USB accessible<br />

memory as a CSV file. The kit includes a stand, GPS and solar panel, etc.<br />

Environmental Flow Meters<br />

See also Flow Meters for Liquids & Gases on page 54-55<br />

Global FP101 Digital Water Velocity Meter<br />

GLO,FP101 (6147)<br />

AU<br />

Portable flow probe - current meter for water velocity<br />

measurements in streams, channels and partially filled pipes.<br />

Propeller sensor in 50mmØ housing, fitted to telescopic handle<br />

[1.8m] with gauging marks to 900mm depth. Digital LCD flow<br />

meter display for instantaneous liquid velocity and average,<br />

maximum, stopwatch or clock. Minimum depth about 50mm.<br />

Range 0.1 to 4.5m/s ±0.05.<br />

Hydrological Services Universal<br />

Current Meter OSS-B1<br />

HYS,OSSB1 (6145)<br />

AU<br />

Water current meter for measurement of flow<br />

velocity in rivers, streams, channels and open<br />

water. Robust streamlined stainless body fitted<br />

with high precision 100mmØ fan [flow range<br />

0.025 to 5m/s]. Set of stainless wading rods for depths to 3m. Rechargeable<br />

“Hydromate” ruggedised field computer with IP65 case. Storage of fan<br />

calibration formulae for direct readout of volume-flow. Touch screen entry for<br />

set up, input, storage and download. Supplied with PC download software<br />

and cable.<br />

Unidata 6526B-21LCD Open Channel Liquid Flow Logger<br />

with LCD Module<br />

UNI,6526B-21LCD (6141)<br />

AU<br />

Open channel flow logger with field LCD display module and 10m cable (2m<br />

depth rating). Measurement and logging of flow-velocity (by Doppler), depth<br />

(by pressure) and temperature. Programmable for flow-channel profile (laptop<br />

PC required for in-situ programming via RS232C). Operating temperature<br />

range 0 to 60°C. Velocity 21 to 5,000mm/s ±2%; depth 0 to 2,000mm ±2%;<br />

temperature: -17 to 60°C ±0.1°C; log-interval 5s to 1 week; memory 120,000<br />

samples. Programmable output to control devices such as water samplers.<br />

Detects and measures reverse flows. Charger and batteries supplied.<br />

Workhead dimensions 290 x 70 x 25mm.<br />

Balances & Scales below 8kg<br />

See also Weighing & Counting Scales over 8kg on page 60<br />

A&D HF-300G Mercury 300g Counting Scales<br />

AND,HF-300G (4439)<br />

AU<br />

Scales 310g, resolution 0.001, repeatability 0.001. Includes RS232 port.<br />

Includes counting software. Can be used as counting scales.<br />

A&D Mercury MX50 Moisture Balance<br />

AND,MX50 (4440)<br />

AU<br />

Maximum sample weight capacity 51g, weight resolution 0.001g, moisture content<br />

accuracy over 1g 0.10%, over 5g 0.02%. Halogen lamp used for heating,<br />

400watt max. Drying temperature 50 to 200ºC. Measurement programs 20 sets,<br />

measurement mode moisture content, wet or dry, dry content, ratio, weight.<br />

Heating mode standard, automatic, quick, timer, manual. Display large VFD,<br />

interface RS-232C, CD-ROM S/W supplied. Pan sample size diameter 85mm.<br />

Ohaus EXP4100 4100g Balance and Counting Scale<br />

OHA,EXP4100 (4432)<br />

AU<br />

Capacity 4.1kg. Display resolution 0.01g. Multi-unit display. Repeatability<br />

0.005g. RS232 interface.<br />

Chemical & Analytical - General<br />

Hydramotion Viscolite 700 Portable Viscometer<br />

HYL,V700S-21 (6352)<br />

AU<br />

Advanced portable viscometer with stainless-steel probe. Operating range<br />

0.1 to 10,000mPaps (cps) with integral temperature correction -40 to 150ºC.<br />

Probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm<br />

(viscosity/temperature). Acetal polymer probe base for handheld or clamped<br />

operation, with coiled-cable connection to meter unit with 5 digit display.<br />

Battery powered.<br />

Laboratory Instruments,<br />

Spectroscopy<br />

X-Rite SP60 Portable Sphere Colour Spectrophotometer<br />

XRI,SP60 (6342)<br />

AU<br />

Portable spectrophotometer for surface colour measurements. Diffuse 8°<br />

[d/8] optical geometry with fixed 8mm aperture. Tungsten source for illuminant<br />

types C, D50, D65, D75, A, F2, F7, F11 & F12. Standard observers 2 & 10°.<br />

Blue-enhanced photodiode detectors with spectral range 400 to 700nm.<br />

Measures opacity and colour by chromatic, apparent or tristimulus calculation,<br />

with simultaneous included and excluded specular component, and spectrum<br />

at 10nm intervals. Storage of up to 2,000 samples with results download to<br />

serial printer or computer. Operation from internal rechargeable battery or AC<br />

adaptor.<br />

74


www.techrentals.com.au<br />

Other Products<br />

Security Equipment<br />

4 Camera Surveillance Digital Stand-Alone Record System<br />

CAM,DVMR-4C (9255)<br />

AU<br />

4 day/night colour cameras with stand-alone digital video multiplex recorder,<br />

complete system with 15” colour LCD screen, 20m connection cables, power<br />

supplies and video to USB converter for down loading of data to PC.<br />

Detec DH50 Hand-held Metal Detector Kit of 4<br />

DET,DH-50-KIT4 (9208)<br />

AU<br />

Kit of 4 x hand held security metal detector. Simple to operate - no adjustment<br />

needed. Audible alarm.<br />

Detec Garrett CS5000 Walk Through Metal Detector<br />

GAR,CS5000 (9211)<br />

AU<br />

Detects all metals. Requires assembly on-site & set-up. Adjustable<br />

sensitivity.<br />

Prospecting Metal Detectors<br />

See also Underground Services Location on page 65<br />

Excaliber 1000 Underwater Metal Detector<br />

EXA,1000 (9204)<br />

AU<br />

MIN,EX-1000<br />

MY<br />

Underwater metal detector with 10 inch search coil. Can be used effectively in<br />

or out of the water and is capable of going down to 60 meters depth. Features<br />

two operating modes; all metal and discriminate. In discriminate mode it will<br />

ignore most ferrous objects and still detect the valuable non-ferrous objects<br />

such as gold and silver. Rechargeable battery pack separated from the<br />

electronics cylinder allows easy access for recharging.<br />

Minelab Discriminating Metal<br />

Detector<br />

MIN,X-TERRA-705 (9205)<br />

AU<br />

Discriminating metal detector. Useful for locating lost<br />

coins rings etc. Preset operating modes depending<br />

upon what is required. Preset noise cancelling.<br />

NOTES<br />

75


NOTES<br />

www.techrentals.com.au<br />

76


www.techrentals.com.au<br />

NOTES<br />

77


NOTES<br />

www.techrentals.com.au<br />

78


www.techrentals.com.au<br />

NOTES<br />

79


OUR BUSINESS UNITS<br />

www.techrentals.com.au<br />

YOU CAN HAVE THE BACKING<br />

OF OUR STRONG TECHNICAL<br />

CAPABILITIES AND ENJOY<br />

SUPPORT FROM SEVERAL<br />

SYNERGISTIC BUSINESS UNITS.<br />

Test & Measurement<br />

<strong>Tech</strong><strong>Rentals</strong> hires specialised test equipment product<br />

solutions for a wide range of industries for periods<br />

from a day to a year or more. Products offered include<br />

power measurement and analysis, general electronic,<br />

environmental and OH&S, plus telecommunications.<br />

The leader in the industrial rental arena for more than<br />

30 years, <strong>Tech</strong><strong>Rentals</strong> also offers flexible purchasing<br />

options on selected product ranges.<br />

www.techrentals.com.au<br />

www.techrentals.com.my<br />

1800 632 652<br />

1800 88 7368<br />

Audiovisual & Business Equipment<br />

TR Vidcom is raising standards in the dynamic<br />

computer and audio-visual industry, offering solutions<br />

for both short & long term equipment procurement and<br />

event management. TR Vidcom has superior product<br />

and industry knowledge, with a nation-wide service<br />

over nine locations across Australia. We can provide<br />

all your computer and audio-visual requirements,<br />

with national support and timely delivery of your<br />

equipment. Our customers include major corporate<br />

companies around Australia and event managers<br />

around the nation. We can deliver, install and fully<br />

train your staff on your premises.<br />

www.trvidcom.com.au<br />

www.videowallsaustralia.com.au<br />

1800 843 266<br />

Satellite Communications<br />

TR Telecom is the region’s largest satellite telephony<br />

service provider, with a customer support team<br />

working from the Australian head office in Melbourne<br />

and offering comprehensive product sales and<br />

connections to the global Iridium network. TR<br />

Telecom’s online store offers a convenient way to<br />

purchase from the Iridium range of products. With<br />

coverage around Australia, New Zealand and<br />

surrounding island regions, you are able to stay<br />

connected with world class satellite voice, data and<br />

tracking solutions.<br />

www.trtelecom.com<br />

1300 550 014<br />

Calibration<br />

Utilising state-of-the-art technology, our experienced<br />

team delivers calibration and repair services to<br />

customers in defence, manufacturing, aviation and<br />

other high tech sectors. TR VMS calibration group<br />

has NATA accredited facilities, plus mobile calibration<br />

labs operating as needed to meet customers’ on-site<br />

demands.<br />

www.trvms.com.au<br />

1300 790 480<br />

Radio Communications<br />

TR Hirecom is the largest two-way radio<br />

communications rental company in Australia and<br />

a division of TR Pty Ltd. Whatever your business<br />

needs, TR Hirecom have the resources to develop<br />

a customised solution that is competitively priced<br />

and of the highest standard, using state-of-the-art<br />

two-way radio communications technology from the<br />

world’s leading manufacturers.<br />

www.trhirecom.com.au<br />

1800 222 327<br />

80


www.techrentals.com.au<br />

TECHRENTALS BUSINESS PARTNERS<br />

Acoustic Research<br />

Laboratories<br />

Anritsu<br />

EXFO<br />

Fluke<br />

Fluke Networks<br />

Gridsense<br />

JDSU<br />

Megger<br />

SebaKMT<br />

Testo<br />

TECHRENTALS ARE DISTRIBUTORS AND RESELLERS FOR:<br />

Anritsu<br />

JDSU<br />

Megger<br />

Gridsense<br />

Acoustic Research Laboratories<br />

SebaKMT<br />

Kingfisher<br />

Flir<br />

TECHRENTALS - THE PERFECT SOLUTION!<br />

<strong>Tech</strong><strong>Rentals</strong> has a vast fleet of products offering solutions for many markets including<br />

Aviation, HVAC, Defence, Electrical, Biomedical, Mechanical and Telco markets,<br />

however if you cannot find what you are looking we have access to our international<br />

partners giving you an even larger and diverse inventory to satisfy your needs.<br />

Remember that it is much more cost effective to Rent than to purchase outright as you are able to<br />

preserve capital for other parts of your business. However if you do need to eventually own the<br />

assets then <strong>Tech</strong> <strong>Rentals</strong> will offer a Rent with Purchase Option. Either way we will find you the assets<br />

you need when you want them.<br />

81


Australia<br />

1800 632 652<br />

www.techrentals.com.au<br />

Malaysia<br />

603 5632 1135<br />

www.techrentals.com.my<br />

<strong>Tech</strong><strong>Rentals</strong> New Zealand*<br />

0800 832 473<br />

www.techrentals.co.nz<br />

*distributor of <strong>Tech</strong><strong>Rentals</strong> Australia<br />

TR0701

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!