Electrical Power<br />

www.techrentals.com.au<br />

Power Analysers & Recorders cont’d.<br />

Fluke 1735 3-Phase<br />

Power Logger<br />

FLU,1735 (8737) AU/MY<br />

Measures single-phase to 3-phase 4-wire circuits,<br />

50/60Hz. 3 voltage inputs with common neutral rated<br />

600Vac (CAT III 600V). 4 current inputs, 4 flexible<br />

current probes (15A to 3000A) are included. Records voltage, current, power<br />

(P, Q & S), power factor, frequency, energy consumption, averaged demand,<br />

harmonics (odd up to 25th order), THD (voltage & current). Includes builtin<br />

batteries for up to 12 hours of recording, and includes Fluke Power Log<br />

software.<br />

Fluke VR1710 Single-Phase Voltage<br />

Quality Recorder<br />

FLU,VR1710 (8720)<br />

AU<br />

Single phase power quality analyser. Records RMS,<br />

transients, flicker & harmonics up to the 32nd. Selectable<br />

logging periods from 1s to 20min. Provides continuous<br />

recording with no gaps. Includes software for download,<br />

analysis and automatic reporting.<br />

Hioki 3169-21 Clamp-On<br />

Power HiTester with<br />

4 x 500A CTs<br />

HIO,3169-21 CT500AMP (8726) AU<br />

Measures voltage, current, power,<br />

power factor, harmonics and integrated<br />

values. Simultaneously performs demand<br />

measurements required for power management and energy-saving. Range<br />

0.05A to 500A. Includes 4 x clamp-on CTs. Supplied software provides graphs<br />

and summaries to PC. Flash card data storage. RS232 interface for PC<br />

communications.<br />

Power Analysers & Recorders cont’d.<br />

Hioki 3169-21 Clamp-On Power HiTester with 4 x 1,000A CTs<br />

HIO,3169-21CT1000AMP (8727)<br />

AU<br />

Measures voltage, current, power, power factor, harmonics and<br />

integrated values. Simultaneously performs demand measurements required<br />

for power management and energy-saving. Range 5A to 1000A. Includes 4<br />

x clamp-on CTs. Supplied software provides graphs and summaries to PC.<br />

Flash card data storage. RS232 interface for PC communications.<br />

Hioki 3169-21 Clamp-On Power HiTester<br />

with 4 x 5,000A FlexCTs<br />

HIO,3169-21CLAMPONPT (8728)<br />

AU<br />

Measures voltage, current, power, power factor, harmonics and integrated<br />

values. Simultaneously performs demand measurements required for<br />

power management and energy-saving. Range 5A to 5000A. Includes 4<br />

x flexible CTs, 500/5000A switchable. Supplied software provides graphs<br />

and summaries to PC. Flash card data storage. RS232 interface for PC<br />

communications.<br />

Hioki 3196 Power Quality Analyser<br />

with 4 x 5,000A Flex CTs<br />

HIO,3196-PQA (8729)<br />

AU/MY<br />

High speed field unit, measuring transient and<br />

sub-cycle disturbances, total energy, tariffs and max<br />

demand. Four voltage (150~600V RMS), and 4<br />

current (0 to 5kA), channels. Includes 4 x flexible CTs, 500/5000A switchable.<br />

Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, and flicker. Memory 512MB<br />

flash card. Colour display. Supplied software provides graphs and summaries<br />

to PC. RS232 or LAN interface for PC communications.<br />

QUALITY PRODUCTS<br />

QUALITY RESULTS<br />

PW3198 Power Quality Analyser<br />

3169-20 Power Analyser<br />

NEW<br />

Cat IV 600V<br />

Class A<br />

Power Analysis<br />

<br />

<br />

<br />

Data Logging<br />

<br />

<br />

<br />

IR5001 Temperature<br />

Humidity Logger<br />

Power Parameters Pty Ltd<br />

83 Northern Road, Heidelberg West, Vic 3081<br />

www.parameters.com.au power@parameters.com.au<br />

Freecall: 1800 623 350 Freefax: 1800 067 263<br />

32<br />

8870-20 Memory HiCorder