www.techrentals.com.au<br />

General Industrial & Process Management<br />

Flow Meters for Liquids & Gases<br />

cont’d.<br />

Combustion, Flue & Industrial<br />

Gas Analysers cont’d.<br />

GE Panametrics -200 to 400°C Transducers<br />

PAN,OKS (6112)<br />

AU<br />

Very high temperature, wide range transducer pair for PAN,PT868/878<br />

transit-time flowmeter. Temperature range -200 to 400°C, for pipe 80mm to<br />

600mmØ. Uses special clamp system supplied. Appropriate protection and<br />

safe-handling equipment is required for fitting and operation at very high or<br />

low temperatures.<br />

Polysonics Hydra SX30 Dual<br />

Frequency Doppler Liquid Flowmeter<br />

POL,HYDRA-SX30-2 (6132)<br />

AU<br />

Dual frequency doppler ultrasonic non-contact<br />

flowmeter. Velocity range 0.06 to 10m/s, accuracy<br />

±1%. Pipe size range 12 to 5,000mm diameter. Data<br />

logging for 90,000 points, with PC software and<br />

interface cable for download via RS232C interface.<br />

Transducer temperature range -40 to 122°C.<br />

Analogue output 4 to 20mA. Battery operated, 12h<br />

continuous use (8h recharge).<br />

Combustion, Flue & Industrial<br />

Gas Analysers<br />

See also Environmental Gas & Vapour Meters on page 67-68<br />

Novatech O 2<br />

and CO 2<br />

Analyser/Transmitter<br />

NOV,1637-5 (5954)<br />

AU<br />

Oxygen and carbon dioxide analyser for packaging<br />

atmosphere, general industrial and research use.<br />

Oxygen sensor reading 1ppm to 100% with 1%<br />

accuracy. NDIR carbon dioxide analysis 0 to 100%<br />

±3% of full scale. 2 x 4 to 20mA outputs, 1 common<br />

& 3 selectable alarm relays. Gas connection 1/8 Swagelok. Flow rate with<br />

internal pump 100 to 500cc/min. AC operation.<br />

Testo 300M Combustion Gas<br />

Analyser<br />

TES,300M<br />

MY<br />

Flue gas analyser for combustion efficiency<br />

measurement. Temperature range -40 to 1200°C<br />

±0.5 (100) with gas probe<br />

operation to 1,000°C max. Draught/pressure<br />

range 80mBar, ±0.03. Gases measured: O 2<br />

0 to<br />

21%, ±0.2%; CO 2<br />

[calculated] 0 to CO 2<br />

max vol ±0.2%; CO 0 to 8,000ppm,<br />

±20 (