Electrical Power<br />

www.techrentals.com.au<br />

Cable & Pipe Tracers & Fault Locators<br />

Electrical Testers<br />

PAT Testers & RCD Testers<br />

Micro-Ohm Meters & Earth Testers<br />

Power Analysers & Recorders<br />

Current Clamps Probes & Accessories<br />

Insulation Testers & Meggers to 20kV<br />

Oil, Hipot & VLF Testers above 20kV<br />

Power Transformer Testers<br />

Current Injectors<br />

Protection Relay Testing Systems<br />

AC Sources/Inverters/Generators<br />

Power Transformers<br />

Power Line Conditioners/UPS<br />

Battery Management Systems<br />

Cable & Pipe Tracers<br />

& Fault Locators<br />

See also Ground Penetrating Radar on page 65<br />

See also Underground Services Location on page 65<br />

CScope CATXDSGV-KIT Cable and Pipe Locator<br />

CSC,CATXDSGV-KIT (3664)<br />

AU/MY<br />

Kit includes a generator with touch button controls and<br />

LCD display and an XD receiver/locator operating at<br />

33kHz. Operates in power or radio modes. Accessories<br />

include direct connection cable, ground stake and<br />

75mm diameter tong set. Transmitter operates by direct<br />

connection, or induction via the tongs. Determines<br />

cable depth, range 0.2m to 3m. Battery powered.<br />

Fluke Cable Locator<br />

FLU,2042 (3602)<br />

AU<br />

Ideal for tracing cables in walls and underground,<br />

locating fuses/breakers on final circuits and locating<br />

interruptions and short-circuits in cables and electrical<br />

floor heating systems. Can be used for tracing metallic<br />

water and heating pipes. Supplied as a kit comprising<br />

a transmitter and receiver in a carry case. Voltage<br />

measurement range 12 to 400 volts. Frequency range<br />

0 to 60Hz. Transmitter output signal 125kHz. Transmitter voltage 0 to 400V<br />

ac/dc. Depth location 0 to 2.5m. Receiver voltage detection range 0 to 0.4m.<br />

The receiver incorporates a torch for working in dimly lit locations.<br />

Save your time and reduce<br />

your real costs. Find out all<br />

about our Confi guration and<br />

<strong>Download</strong> solutions on page 43.<br />

Cable & Pipe Tracers<br />

& Fault Locators cont’d.<br />

Megger MPP1002 Cable Fault<br />

Pinpoint Locator<br />

MEG,MPP1002-FAULT PP (3603) A U<br />

PPinpoints faults in shielded and direct buried<br />

primary cables via Geophone probe(s). Can<br />

be used with any surge generator (thumper).<br />

Stand-alone unit measures electromagnetic surge<br />

and supplies the amplitude of that surge which aids in finding the fault. When<br />

fitted with probes the unit will detect the acoustic discharge (thump), measure<br />

the time delay between acoustic and electromagnetic signals and calculate<br />

the distance to fault. Using the dual probe system the direction to fault is<br />

indicated. Detects faults up to 23m away. Battery powered.<br />

Megger TDR20002RM Dual Channel TDR Cable Fault Locator<br />

MEG,TDR2000/2RM (3605)<br />

AU<br />

Time Domain Reflectometer cable fault locator. User selectable ranges from<br />

0 to 50m up to 20km, minimum resolution 0.1m. Dual cursor measurement.<br />

Internal memory for 15 traces. Megger “Tracemaster” software supplied.<br />

RS232 interface for PC communications. High resolution LCD display. Battery<br />

powered. Dust and shower proof to IP54.<br />

Riser Bond 1205T-OSP Metallic TDR Cable Fault Locator<br />

RB,1205T-OSP<br />

MY<br />

Dual input metallic time domain reflectometer cable fault locator for coaxial<br />

cables. Maximum Range: 63,700ft (19,400meters) at .990 VOP. Distance<br />

Accuracy: +/- 0.1ft (0.03m) plus +/- .01% of reading. Can Store, Recall and<br />

<strong>Download</strong> Waveform, via RS232 cable. (Viewable with Software.)<br />

Electrical Testers<br />

See also Current Clamps Probes & Accessories on page 33-35<br />

AVO Penta-Plus DMM Analyser<br />

AVO,PENTA-PLUS-DMM (3621)<br />

AU<br />

Portable battery/line operated multifunction instrument<br />

for measuring AC voltage, AC primary and secondary<br />

current, power, reactive power, phase angle and<br />

frequency of a single or three phase electrical system.<br />

Easily configured to measure the amplitude and phase angle between any two<br />

voltage and current inputs. All measured values are displayed simultaneously<br />

on a large display. Ranges; voltage 0 to 650V, current 0 to 100A, power +/-0 to<br />

100kW, reactive power +/-0 to 100kVAR. Resolution of above measurements<br />

0.1%. Phase angle 0 to 360 degree, resolution 0.1 degree. Frequency 45 to<br />

65Hz, accuracy +/-0.01Hz. Timer 0 to 999.999sec, accuracy +/-0.001sec.<br />

Memory records 60 test results. RS232 data and parallel printer output ports.<br />

CATU C-8-36 Phasing Stick - Two Pole Phase<br />

Comparator for Indoor Use<br />

CAT,CL-8-36 PH STICK (3622)<br />

AU<br />

Detects differences in voltage between any two<br />

points of an installation. Indication by LEDs.<br />

Voltage range 2kV to 36kV. Enables assessment<br />

of the order of magnitude of the residual voltage induced by nearby live lines<br />

or circuits, and thus differentiates it from the one provided directly from a high<br />

voltage source. Two 1.25m elements with removable probes, connected via a<br />

high-insulation lead. Maximum working distance 2.25m.<br />

Hioki 3283 Clamp on Leak HiTester<br />

HIO,3283 CLAMP ON-LT (3623)<br />

AU/MY<br />

Monitor leak current fluctuations. Bandwidth 5Hz to 15kHz.<br />

AC current range 10mA to 200A, resolution 10microA. Accuracy<br />

+/-1%. LCD display. Battery powered.<br />