Electrical Power<br />
www.techrentals.com.au<br />
Cable & Pipe Tracers & Fault Locators<br />
Electrical Testers<br />
PAT Testers & RCD Testers<br />
Micro-Ohm Meters & Earth Testers<br />
Power Analysers & Recorders<br />
Current Clamps Probes & Accessories<br />
Insulation Testers & Meggers to 20kV<br />
Oil, Hipot & VLF Testers above 20kV<br />
Power Transformer Testers<br />
Current Injectors<br />
Protection Relay Testing Systems<br />
AC Sources/Inverters/Generators<br />
Power Transformers<br />
Power Line Conditioners/UPS<br />
Battery Management Systems<br />
Cable & Pipe Tracers<br />
& Fault Locators<br />
See also Ground Penetrating Radar on page 65<br />
See also Underground Services Location on page 65<br />
CScope CATXDSGV-KIT Cable and Pipe Locator<br />
CSC,CATXDSGV-KIT (3664)<br />
AU/MY<br />
Kit includes a generator with touch button controls and<br />
LCD display and an XD receiver/locator operating at<br />
33kHz. Operates in power or radio modes. Accessories<br />
include direct connection cable, ground stake and<br />
75mm diameter tong set. Transmitter operates by direct<br />
connection, or induction via the tongs. Determines<br />
cable depth, range 0.2m to 3m. Battery powered.<br />
Fluke Cable Locator<br />
FLU,2042 (3602)<br />
AU<br />
Ideal for tracing cables in walls and underground,<br />
locating fuses/breakers on final circuits and locating<br />
interruptions and short-circuits in cables and electrical<br />
floor heating systems. Can be used for tracing metallic<br />
water and heating pipes. Supplied as a kit comprising<br />
a transmitter and receiver in a carry case. Voltage<br />
measurement range 12 to 400 volts. Frequency range<br />
0 to 60Hz. Transmitter output signal 125kHz. Transmitter voltage 0 to 400V<br />
ac/dc. Depth location 0 to 2.5m. Receiver voltage detection range 0 to 0.4m.<br />
The receiver incorporates a torch for working in dimly lit locations.<br />
Save your time and reduce<br />
your real costs. Find out all<br />
about our Confi guration and<br />
<strong>Download</strong> solutions on page 43.<br />
Cable & Pipe Tracers<br />
& Fault Locators cont’d.<br />
Megger MPP1002 Cable Fault<br />
Pinpoint Locator<br />
MEG,MPP1002-FAULT PP (3603) A U<br />
PPinpoints faults in shielded and direct buried<br />
primary cables via Geophone probe(s). Can<br />
be used with any surge generator (thumper).<br />
Stand-alone unit measures electromagnetic surge<br />
and supplies the amplitude of that surge which aids in finding the fault. When<br />
fitted with probes the unit will detect the acoustic discharge (thump), measure<br />
the time delay between acoustic and electromagnetic signals and calculate<br />
the distance to fault. Using the dual probe system the direction to fault is<br />
indicated. Detects faults up to 23m away. Battery powered.<br />
Megger TDR20002RM Dual Channel TDR Cable Fault Locator<br />
MEG,TDR2000/2RM (3605)<br />
AU<br />
Time Domain Reflectometer cable fault locator. User selectable ranges from<br />
0 to 50m up to 20km, minimum resolution 0.1m. Dual cursor measurement.<br />
Internal memory for 15 traces. Megger “Tracemaster” software supplied.<br />
RS232 interface for PC communications. High resolution LCD display. Battery<br />
powered. Dust and shower proof to IP54.<br />
Riser Bond 1205T-OSP Metallic TDR Cable Fault Locator<br />
RB,1205T-OSP<br />
MY<br />
Dual input metallic time domain reflectometer cable fault locator for coaxial<br />
cables. Maximum Range: 63,700ft (19,400meters) at .990 VOP. Distance<br />
Accuracy: +/- 0.1ft (0.03m) plus +/- .01% of reading. Can Store, Recall and<br />
<strong>Download</strong> Waveform, via RS232 cable. (Viewable with Software.)<br />
Electrical Testers<br />
See also Current Clamps Probes & Accessories on page 33-35<br />
AVO Penta-Plus DMM Analyser<br />
AVO,PENTA-PLUS-DMM (3621)<br />
AU<br />
Portable battery/line operated multifunction instrument<br />
for measuring AC voltage, AC primary and secondary<br />
current, power, reactive power, phase angle and<br />
frequency of a single or three phase electrical system.<br />
Easily configured to measure the amplitude and phase angle between any two<br />
voltage and current inputs. All measured values are displayed simultaneously<br />
on a large display. Ranges; voltage 0 to 650V, current 0 to 100A, power +/-0 to<br />
100kW, reactive power +/-0 to 100kVAR. Resolution of above measurements<br />
0.1%. Phase angle 0 to 360 degree, resolution 0.1 degree. Frequency 45 to<br />
65Hz, accuracy +/-0.01Hz. Timer 0 to 999.999sec, accuracy +/-0.001sec.<br />
Memory records 60 test results. RS232 data and parallel printer output ports.<br />
CATU C-8-36 Phasing Stick - Two Pole Phase<br />
Comparator for Indoor Use<br />
CAT,CL-8-36 PH STICK (3622)<br />
AU<br />
Detects differences in voltage between any two<br />
points of an installation. Indication by LEDs.<br />
Voltage range 2kV to 36kV. Enables assessment<br />
of the order of magnitude of the residual voltage induced by nearby live lines<br />
or circuits, and thus differentiates it from the one provided directly from a high<br />
voltage source. Two 1.25m elements with removable probes, connected via a<br />
high-insulation lead. Maximum working distance 2.25m.<br />
Hioki 3283 Clamp on Leak HiTester<br />
HIO,3283 CLAMP ON-LT (3623)<br />
AU/MY<br />
Monitor leak current fluctuations. Bandwidth 5Hz to 15kHz.<br />
AC current range 10mA to 200A, resolution 10microA. Accuracy<br />
+/-1%. LCD display. Battery powered.<br />
26