DC Power Supplies & Loads cont’d.<br />

Sorensen DCS60-50 60V 50A DC Power Supply<br />

SOR,DCS60-50 (8114)<br />

AU<br />

0 to 60V, 0 to 50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph<br />

240V supply. On 1ph 50V@50A or 60V@42A. Remote programming.<br />

TR Built 12V Battery Supply with Cigarette Power Connector<br />

TR,12V-BAT-CIG (8160)<br />

AU<br />

12V 20AH battery pack with built-in charger. Has cigarette outlet and banana<br />

plug connectors.<br />

Trio Kenwood PD35-20 DC Power Supply<br />

TRI,PD35-20 (8109)<br />

AU<br />

Output 0 to 35V, 0 to 20A. Constant current, constant voltage. Multiple<br />

parallel or series operation. Remote programming of voltage or current by<br />

external voltage or resistance.<br />

Xantrex XFR 600-4<br />

Power Supply<br />

XAN,XFR600-4 (8112)<br />

AU<br />

2.8kW programmable DC power supply 0 to 600V, 0 to 4A. RS-232 and<br />

isolated analogue control options.<br />

Spectrum Analysers - Low Frequency<br />

See also Spectrum Analyser - High Frequency on page 12 & 14<br />

See also Noise & Sound Analysers on page 70-71<br />

Agilent/HP 35670A 100kHz Spectrum<br />

Analyser<br />

HP,35670A (2480)<br />

AU<br />

Quad channel 122μHz to 102.4kHz spectrum<br />

analyser. Up to 1600 line resolution. Displays<br />

frequency response, power spectrum, linear<br />

spectrum, coherence, cross spectrum, power<br />

spectral density, and time. Signal sources: Fixed & swept sine, arbitrary<br />

waveform, random noise, chirp. Built-in disk drive. HPIB plotter interface.<br />

Bandwidth is 102.4, 51.2 and 25.6KHz for single, dual and quad channel<br />

measurements respectively.<br />

TV Test Equipment<br />

See also Network Analysers/Antenna & Cable Test on page 14 & 16<br />

Promax TV Explorer Prodig-5<br />

PRO,PRODIG-5 (1727)<br />

AU<br />

For the installation, maintenance and surveillance<br />

of terrestrial, satellite and cable TV systems.<br />

Automatically provides information about the<br />

channels available in the network and their quality.<br />

Displays analogue and digital channel picture.<br />

Includes a high resolution spectrum analyser<br />

function and MPEG decoding. Foxtel approved.<br />

Promax Prolink 4C Premium Analogue/<br />

Digital TV Test Set<br />

PRO,PROLINK4C-PREM (1729)<br />

AU<br />

Measures terrestrial, satellite and cable<br />

TV systems including analogue and digital<br />

VHF & UHF bands. Built in colour monitor provides measurement readout and<br />

can be used to display video signal. Measurement functions include spectrum<br />

analysis, direct signal level readout, carrier to noise, channel power, digital<br />

carrier to noise, digital bit error ratio (BER) and digital QAM constellation.<br />

DVB digital TV channel identifier. Logs to PC and includes software for<br />

remote control and channel plan management.<br />

Laboratory Calibrators<br />

See also Industrial Process Calibrators on page 46-49<br />

Fluke 5500A Multi Product<br />

Calibrator with NATA Calibration<br />

FLU,5500A-NATA (4707)<br />

AU<br />

FLU,5500A<br />

MY<br />

Calibrator sources direct voltage<br />

& current, alternating voltage and<br />

current, with multiple waveforms and harmonics, 2 simultaneous voltage<br />

outputs or voltage & current. Simulates power with phase control, resistance,<br />

capacitance, thermocouples and RTDs. Selectable ranges include the<br />

following outputs VDC from 0 to 1.02kV, VAC from 1mV to 1.02kV with output<br />

from 10Hz to 500kHz. AC current from 0.01μA to 11A with output from 10Hz<br />

to 10kHz. DC current from 0 to 11A. Resistance values from short circuit<br />

to 330MΩ. Capacitance values from 330pF to 1,100μF. Temperature t/c B,<br />

C, E, J, K, L, N, R, S, T, U, RTD Pt385 100Ω, Pt3926 100Ω, Pt3916 100Ω,<br />

Pt385 200Ω, Pt385 500Ω, Pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.<br />

Genrad 1433B 1.1MΩ 6 Decade Resistance<br />

GR,1433B-NATA (4702)<br />

Six decades by 1Ω to 1.1MΩ. Accuracy 0.01%. NATA calibrated.<br />

Genrad 1433F 111k 7 Decade Resistance Box<br />

GR,1433F-NATA (4704)<br />

AU<br />

Seven decades by 0.01Ω to 111k. Accuracy 0.01% +0.002Ω. Useful for<br />

platinum resistance thermometer calibration. NATA calibrated.<br />

Genrad 1433-20 11.1111kΩ<br />

6 Decade Resistor<br />

GR,1433-20<br />

MY<br />

Six decades by 0.01Ω per step to<br />

11.1111kΩ. High accuracy 0.01% up to 10MΩ steps. Low temperature<br />

coefficient, 5ppm/˚C. Good frequency characteristics, excellent stability<br />

(10ppm/yr, 25ppm/3yrs), low zero resistance (1MΩ per decade). May be used<br />

for RTD stimulation. Rack mount option.<br />

Logic Analysers/PROM Programmers<br />

HP 1662A 68 Channel Logic Analyser<br />

HP,1662A (1570)<br />

MY<br />

Timing analysis 250MHz all channels, 500MHz half channels. Transitional:<br />

125MHz all channels, 250MHz half channels. Glitch: 125MHz half<br />

channels. State analysis to 100MHz on all channels. Memory 4k/channel,<br />

8k/channel in half-channel modes. 4 clock channels available. HPIB &<br />

RS232C ports. In-built DOS format FDD used to load inverse assemblers<br />

& transfer measurement data to a computer. Compatible with most HP<br />

preprocessors & inverse assemblers.<br />

Gauss/Tesla Meters<br />

FW Bell Gauss/Tesla Meter<br />

BEL,4190 (1969)<br />

AU<br />

Handheld digital ELF gauss meter. Maintains<br />

accuracy regardless of orientation. Applications<br />

include detecting magnetic field emissions from<br />

overhead AC power lines, video display terminals,<br />

office equipment and household appliances.<br />

Analogue o/p, data logging, auto range 0.1 to 1999<br />

mG, minimum resolution 0.1mG/.01 uT.<br />

AU<br />