General Industrial & Process Management<br />
Data Loggers cont’d.<br />
Data Loggers cont’d.<br />
Hioki 3641-20-Kit of 8 Temperature & Humidity<br />
Loggers<br />
HIO,3641-20-KIT (4256)<br />
AU<br />
Kit of 8 x temperature and humidity loggers. Includes<br />
1 x RS232C and 1 x USB communication base,<br />
utility software, RS232C and USB interface cables.<br />
Environment conditions for operation -20 to 70ºC,<br />
80%RH (no condensation) Accuracy: Temperature -40 to<br />
-0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC, 35.1 to 70ºC ±1ºC. Humidity typical between<br />
±5 to ±10% depends on temperature and humidity range. 8000 data points x<br />
2 channels, recording interval 2,5,10,15,20,30s and 1,2,5,10,15 ,20,30,60min.<br />
Hioki 8421-01 16 Channel Data Logger with Colour Display<br />
HIO,8421-01 (4270)<br />
AU<br />
16 analogue, 4 pulse input channels data logger with colour<br />
display, PCMCIA card slot, LAN interface built in, TCP/IP communication<br />
supports real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVDC,<br />
1VDC, 10VDC, 60VDC, 1 to 5VDC fs. Thermocouples K,E, J, T, N, W (WRe5<br />
to 26) R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100<br />
-200 to 800ºC. Pulse input, accumulation 50,000 counts fs, 500,000 counts<br />
fs, 5M counts fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s)<br />
fs. Recording interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20,<br />
30s, 1, 2 & 5min. Max sampling rate is dependent upon type of input signal.<br />
Internal Memory 8Mb, 256Mb Flashcard, 9334 logger communicator<br />
software, 9642 LAN cable, 9641 pulse signal input cable all supplied.<br />
Hioki 8421-51 16 Channel Data Logger with Colour Display<br />
HIO,8421-51 (4271)<br />
AU<br />
16 analogue, 4 pulse input channels data logger with colour display, PCM-<br />
CIA card slot, LAN interface built in, TCP/IP communication supports real<br />
time PC logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1VDC,<br />
10 VDC, 60VDC, 1-5VDC f.s. Thermocouples K, E, J, T, N, W (WRe5-26),<br />
R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100 -200<br />
to 800ºC. Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s,<br />
100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval<br />
selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min,<br />
2min, 5min. Max sampling rate is dependent upon type of input signal.<br />
Internal Memory 16MW, 512MB PCMCIA FLASH card, 9334 Logger<br />
Communicator software, 9642 LAN cable, 9641 pulse signal input<br />
cable all supplied. Improved common mode rejection -100dB or better<br />
when 50/60Hz, 140dB or better when 50Hz, using ch1 to ch16, interval 5s,<br />
digital filter 50Hz selected. Faster sampling when using Pt100, improved<br />
temperature characteristics.<br />
Hioki 8422-51 32 Channel Data Logger<br />
HIO,8422-51 (4273)<br />
AU<br />
32 analogue, 4 pulse input channels data logger with colour display, PCMCIA<br />
card slot, LAN interface built in, TCP/IP communication supports real time PC<br />
logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1 VDC, 10 VDC, 60<br />
VDC, 1-5V DC f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, B, -100 to<br />
100ºC, -200 to 500ºC, -200 to 2,000ºC, Pulse input, accumulation 50,000C<br />
f.s, 500,000C f.s, 5MC f.s, 100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s)<br />
f.s. Recording interval is selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s,<br />
10s, 20s, 30s, 1min, 2min, 5min. Max sampling rate is dependent upon type<br />
of input signal. Internal Memory 8MB, 512MB PCMCIA FLASH card, 9334<br />
Logger Communicator software, 9642 LAN cable, 9641 pulse signal input<br />
cable all supplied.<br />
Hioki Kit of Three 9322 Differential Probe High Voltage<br />
True RMS Interface<br />
HIO,9322-KIT (4119)<br />
AU<br />
Used with many memory recorders, eg. Hioki 8835. Operating modes 3.<br />
DC mode for waveform monitor output DC to 3MHz, AC mode detection of<br />
power surge noise 1kHz to 10MHz. Rectified true RMS output of DC & AC<br />
voltages. 40Hz to 100kHz response speed 200ms or less. Max voltage DC<br />
2kV, AC 1kV CATII, AC/DC 600V CATIII, balanced differential input 1/1,000<br />
divider.<br />
Testo 175-H1 Temperature<br />
& Humidity Logger<br />
TES,175-H1 (4251)<br />
AU<br />
Large display. 3 year battery life, 1 million sample memory. RH<br />
0 ~100% ±2%, temperature -20~50ºC ±-0.4ºC . Includes USB<br />
interface to download data<br />
Testo 177-H1 Logger with Display<br />
TES,177-H1<br />
MY<br />
Parameters: humidity/temperature/dew point. Sensors: humidity sensor/<br />
NTC (internal). Number of channels: 4. Measuring range: 0 to 100%RH and<br />
-20 to 70ºC (internal). Memory: 48,000 readings.<br />
Testo 177-T4 Logger with Display<br />
TES,177-T4<br />
MY<br />
Parameters: temperature (C/F). Sensors: thermocouple type-K. Number<br />
of channels: 4 (external). Measuring range: -100 to 1,000 ºC (external).<br />
Memory: 48,000 readings.<br />
See also Air Conditioning & Air Flow on page 62-63<br />
Pressure & Humidity Transducers<br />
Druck PTX1400 4Bar Pressure Transducer<br />
DRU,PTX1400-4 (4307)<br />
AU<br />
Output 4 to 20mA. Requires 9 to 36VDC. Supplied with 12V<br />
plug pack. Pressure input connector G ¼” female.<br />
Druck PTX1400-25 25Bar Pressure Transducer 4 to 20mA<br />
DRU,PTX1400-25 (4302)<br />
AU<br />
Output 4 to 20mA output, 0 to 25Bar input. Requires 9 to 28VDC, supplied<br />
with 12V, 500mA power pack.<br />
Druck PTX 1400 600Bar Pressure Transducer<br />
DRU,PTX1400-600 (4305)<br />
Output 4 to 20mA. Requires 9 to 32VDC, supplied with 12V plug pack.<br />
Fluke PV350 Vacuum/Pressure Indicator<br />
FLU,PV350 (4321)<br />
AU<br />
Can be used with a digital multimeter to act as an<br />
indicator. Range, pressure to 4137kPa and vacuum 0 to<br />
76cmHg. Results in either psi or kPa. Connector 1/2”NPT<br />
(m). Cable 2.4m provided. Battery powered.<br />
Pressure Vacuum Gauges/Recorders<br />
Crystal XP2i Digital Logging<br />
Pressure Gauge 7Bar NATA calibrated<br />
CRY,XP2I-100-NATA (4341)<br />
AU<br />
Range 7Bar resolution 0.1mBar. Accuracy 1.4 to 7Bar<br />
±0.1% of reading. 0 to 1.4Bar ±1.4mBar. Vacuum<br />
±17.5mBar. Has a 6000 point logging capability. Logging<br />
intervals from 1s up can be set. Logs either actual<br />
pressure, average pressure or average pressure with max<br />
and min. Also logs on demand. ¼″ NPT connector.<br />
Crystal XP2i Digital Logging<br />
Pressure Gauge 20Bar NATA calibrated<br />
CRY,XP2I-300-NATA (4341)<br />
AU<br />
Range 20Bar resolution 1mBar. Accuracy 4 to 20Bar<br />
±0.1% of reading. 0 to 4Bar ±4mBar. It Has a 6000 point<br />
logging capability. Logging intervals from 1s up can be set.<br />
Logs either actual pressure, average pressure or average<br />
pressure with max and min. Also logs on demand.<br />
AU<br />