General Industrial & Process Management<br />

www.techrentals.com.au<br />

Industrial Process Calibrators cont’d.<br />

Industrial Process Calibrators cont’d.<br />

Druck DPI610-20IS 20Bar Pressure Calibrator<br />

DRU,DPI610-20IS<br />

MY<br />

Ranges -1 to 20Bar. Accuracy 0.025% fs all ranges. Integral combined<br />

pressure/vacuum pump. Dual readout: input & output. 4 to 20mA loop test:<br />

auto step and ramp. RS232 interface and fully documenting version. Remote<br />

pressure sensors. Intrinsically safe version.<br />

Druck DPI610-400-NATA 400Bar Pressure Calibrator<br />

DRU,DPI610-400-NATA (4758)<br />

AU<br />

DRU,DPI610-400<br />

MY<br />

Hydraulic pressure calibrator including pump and current voltage standard.<br />

Pressure range 0 to 400Bar ±0.025%fs. Voltage input 50VDC, ±0.05%rdg,<br />

±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature -10 to<br />

40ºC ±1ºC (ambient) switch open/closed. Voltage output 10VDC ±0.1% or 24V<br />

±5%. Current output 0 to 24mA, ±0.05% rdg, ±0.01%fs. Data logger stores<br />

up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes<br />

flexible hose kit. Pump includes screw adjustment.<br />

Druck DPI615-20-NATA 20Bar<br />

Pressure Calibrator<br />

DRU,DPI615-20-NATA (4756)<br />

AU<br />

Pneumatic pressure calibrator including pump and<br />

current voltage standard. Pressure range 0 to 20Bar<br />

±0.025% FS. Voltage input ±50VDC ±0.05% rdg<br />

± 0.004% FS. Current input ±55mA ±0.05%rdg<br />

±0.004%FS. Temperature -10 to 40ºC ±1ºC (ambient)<br />

switch open/closed. Voltage output 10VDC ±0.1% or<br />

24V ±-5%. Current output 0 to 24mA ±0.05%rdg<br />

±0.01%FS. Data logger stores upto 10,000 values. mA ramp configurable.<br />

Pressure port G 1/8 female, includes flexible hose. Pump includes screw<br />

adjustment.<br />

Druck PV411A Multifunction Hand Pump Kit<br />

DRU,PV411A (4771)<br />

AU/MY<br />

Provides up to 700Bar hydraulic, 40Bar pneumatic<br />

pressures and vacuum to -950 mBar. Built-in stroke<br />

adjuster, lower pressure fine control and tamper proof<br />

overpressure protection.<br />

Druck UPS III-IS Intrinsically Safe Loop Calibrator<br />

DRU,UPS III-IS (4777)<br />

AU<br />

Measure or source 0 to 24mA and provide 24V loop power.<br />

50 VDC measurement and continuity. Accuracy 0.015% of<br />

reading, Hart compatible. Dual mA and % readout, linear<br />

or flow. It is an essential tool for loop testing, instrument<br />

maintenance and valve set-up, with an easy-to-read<br />

display and simple-to-use time saving features.<br />

Emerson Process Management 375<br />

Field Communicator<br />

EME,375 (4781)<br />

AU/MY<br />

Will configure, test, and diagnose your<br />

HART® and Foundation FieldBus devices.<br />

Able to communicate with any device, by<br />

any manufacturer. Intrinsically safe. Easy<br />

upgrade over the Internet. Interfaces with<br />

AMS PC Suite Software.<br />

Emerson 475 Hart Communicator<br />

EME,475 (4779)<br />

AU/MY<br />

Will configure, test, and diagnose your HART® and<br />

Foundation FieldBus devices. Able to communicate with<br />

any device, by any manufacturer. Intrinsically safe. Easy<br />

upgrade over the Internet. Interfaces with AMS PC Suite<br />

Software.<br />

Softing BC-600-PB Profibus Tester 4<br />

SOF,PROFIBUS-4 (4775)<br />

AU<br />

Allows full testing of live PROFIBUS segments with<br />

minimum influence on their operation. Detects transient<br />

faults that occur sporadically. Test for non operation PLCs<br />

or suspicious devices. Simultaneous analysis of both bus<br />

physics and bus communication. Master simulator and<br />

Topology scan. Expert tests: frame, oscillogram analysis<br />

and trigger input/output. Long term trend measuring,<br />

preventive maintenance and detailed test reporting.<br />

Fitting Set with 700Bar Hose<br />

FIT,HP<br />

MY<br />

Fitting set (max pressure = 10,000psi) for pressure calibrators. Female<br />

connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP & NPT; 3/8 inch BSP &<br />

NPT; 1/2 inch BSP & NPT.<br />

Fitting Set With 20Bar Hose<br />

FIT,LP<br />

MY<br />

Fitting set (max pressure = 10,000psi) for pressure calibrators. Female<br />

connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP & NPT; 3/8 inc BSP &<br />

NPT; 1/2 inch BSP & NPT.<br />

Fluke 70Bar Pressure Transducer to suit Fluke<br />

Calibrators 725 & 744<br />

FLU,700P08-70BAR (4764)<br />

AU<br />

For use with the Fluke 744 & 725 industrial calibrators.<br />

Pneumatic system range 0 to 70Bar, resolution<br />

7mBar, reference uncertainty 0.025%. Connection 1/4<br />

NPT and 1/4 ISO. Includes 700PTP-1 pressure pump.<br />

(Note the pump will operate to 41Bar).<br />

Fluke 690Bar Pressure Transducer to suit<br />

Calibrators 744 & 725<br />

FLU,700P31-690BAR (4765)<br />

AU<br />

For use with the Fluke 744 & 725 industrial calibrators.<br />

Range 0 to 690Bar, reference uncertainty .025%.<br />

Connection 1/4 NPT and 1/4 ISO Includes 700LTP-1<br />

pressure pump.<br />

Fluke 7Bar Pressure Transducer & Pump to suit FLU,744 & FLU,725<br />

FLU,700PD6-7BAR (4763)<br />

AU<br />

For use with the Fluke 744 & &25 industrial calibrators. Range 100 to 690kPa,<br />

reference uncertainty .025%. Connection 1/4 NPT and 1/4 ISO Includes<br />

700LTP-1 pressure pump.<br />

Fluke 718 300G Pressure Calibrator<br />

FLU,718-300G (4793)<br />

AU<br />

Pressure source and milliamp measurement. Pressure<br />

specs -83 to 2068kPa ±0.05% of range. Max pressure<br />

2.6MPa. Current specs: 0.0001mA resolution,<br />

accuracy 0.015%. Calibrate P/I (pressure to current)<br />

transmitters, measures pressure via a 1/8 inch NPT<br />

pressure fitting and an internal pressure sensor, source<br />

pressure, measure current up to 24mA, simultaneously<br />

display pressure and current measurements, supplies<br />

loop voltage, calculates percentage in percent mode,<br />

calculates mA error in percent error mode.<br />

Fluke 719 2Bar-30G Pressure Calibrator including Electric Pump<br />

FLU,719-30G (4795)<br />

AU<br />

2Bar, includes pump and precision 4 to 20mA measurement and source<br />

capability. The pump in this instrument is electric. Uncertainty 0.025%.<br />

Precision pressure adjustment vernier. Range -850mBar to 2Bar. Resolution<br />

0.1mBar. 4 to 20mA resolution .001mA .015%rdg + 2 counts.<br />