Download - Tech-Rentals
Download - Tech-Rentals
Download - Tech-Rentals
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Environmental, OHS, Chemical & Laboratory<br />
www.techrentals.com.au<br />
Water Quality, pH Meters<br />
& Electrochem cont’d.<br />
Hydrolab Minisonde 5 Multiprobe<br />
Water Logger<br />
HYD,MS5 (6020)<br />
AU<br />
Miniosonde 5 multiprobe water/borehole logger,<br />
including ‘Surveyor’ data collection system with<br />
GPS. Includes sensors for Dissolved Oxygen<br />
(HACH LDO), Conductivity, pH, Redox (ORP),<br />
Turbidity (Self-Cleaning), Temperature, Depth (0<br />
to 25m) and GPS position. Includes the surveyor<br />
data aquisition system so no laptop is needed for<br />
download or data collection. Includes a 25m cable.<br />
ISCO 6700 Series Water Sampler<br />
ISCO,6712 (6057)<br />
AU<br />
Advanced water sampler for fully programmed<br />
collection. Samples are collected in up to 24<br />
disposable plastic containers based on time, flow,<br />
and/or parameter set points. Fitted with NEMA 4X,6<br />
(IP67) sealed controller featuring an exclusive,<br />
built-in pump.<br />
Isco 6700 Series Water Sampler with Bubbler<br />
Flow Module<br />
ISK,6700-730 (6056)<br />
AU<br />
Advanced water sampler for fully programmed<br />
collection. Samples can be collected in 1, 2, 8, or 24,<br />
1 litre disposable sample containers based on time,<br />
flow, and/or parameter set points. Fitted with NEMA<br />
4X,6 (IP67) sealed controller featuring an exclusive,<br />
built-in pump, flash memory for easy programming<br />
changes, and a plug-in module port for connection of a flow meter module or<br />
parameter measurement module to enhance monitoring capabilities. Provided<br />
with bubbler flow module. Sample bottles available. Run from rechargeable<br />
12V sealed batteries.<br />
OTT KL010-150 Ground-water Depth Measurement Contact Gauge 150m<br />
OTT,KL010-150 (6065)<br />
AU<br />
Contact gauge for portable depth to water measurement. Used for wells,<br />
observation pipes, bore holes and control pumping tests. 150m depth of tape.<br />
as soon as the probe touches the water surface an acoustic signal beeps and<br />
the lamp on the instrument lights up. The depth is read from the measuring<br />
tape in meters.<br />
Solinist Oil/Water Interface Meter<br />
SOL,122 (6066)<br />
AU<br />
Used for bore determination of LNAPL or DNAPL levels. Flat tape on a reel<br />
when lowered down a bore hole a light and tone indicate the LNAPL (Light<br />
Non-Aqueous Phase Liquid) layer or the DNAPL (Dense Non-Aqueous Phase<br />
Liquid) level. The level is measured from the 50m tape.<br />
TPS 90FL-T Water Quality Meter<br />
TPS,90FL-T (6028)<br />
AU<br />
Field meter and logger for water<br />
quality measurements. Configured with<br />
independent probes for pH, conductivity/<br />
salinity[TDS]/temperature,<br />
dissolved<br />
oxygen[DO] and turbidity. Cables 5m with<br />
probe holder and safety harness. LCD display<br />
readout with simultaneous display of all measurements. Manual, “notepad”<br />
storage or automated data logging for up to 1,808 sets of readings by time<br />
and date. RS232C interface, with WinTPS software included. Supplied with<br />
rechargeable battery, and clip-lead for operation from a 12V source such as<br />
a car-battery.<br />
Water Quality, pH Meters<br />
& Electrochem cont’d.<br />
TPS Conductivity Probe With Cell K=0.1<br />
TPS,LOW K PROBE ( 6016)<br />
AU<br />
Plastic-bodied conductivity and temperature sensor for WP series meters.<br />
With k=0.1 and automatic temperature compensation ATC. For precision<br />
measurement at low conductivity levels. Minimum range with WP-84 2 uS/cm<br />
to 2,000uS/cm. Temperature range -10 to 60°C. Fitted with 5m cable.<br />
TPS Redox Electrode<br />
TPS,REDOX (6004)<br />
AU<br />
Silver/chloride Redox electrode for use with TPS LC80A Ph meter. Supplied<br />
with 2 bottles of Zobell solution for calibration. 1:1 dilution gives approx.<br />
231mV.<br />
TPS WP-80 pH and Temperature<br />
Meter<br />
TPS,WP-80 (6003)<br />
AU<br />
Portable hand-held meter for pH, mV and<br />
temperature. Supplied with combination pH<br />
electrode and separate temperature sensor on<br />
1m cables. Operating ranges 0 to 14pH and<br />
-10 to 120ºC (automatic sensor recognition<br />
with auto pH correction 0 to 100ºC). Case water resistant to IP67, connectors<br />
to IP65. Menu driven, with alphanumeric display. Auto storage of time and date<br />
of last calibration for GLP. Memory for 2400 readings of data, time and date,<br />
for Notepad results collection, or for AutoLog with logging intervals between<br />
1s and 90h. Fitted with RS232C interface and supplied with downloadsoftware,<br />
charger and solutions. Rechargeable NiMH battery gives up to<br />
50h operation.<br />
TPS WP-80 pH and Temperature Meter<br />
for Testing Meat<br />
TPS,WP-80M (6002)<br />
AU<br />
Portable hand-held meter for pH, mV and temperature.<br />
The instrument is capable of applying Bendalls<br />
equation to the pH reading for Meat Standards Australia<br />
grading requirements. Supplied with combination pH<br />
electrode and separate temperature sensor on 1m<br />
cables. Operating ranges 0~14pH and -10~120ºC<br />
[automatic sensor recognition with auto pH correction 0~100ºC]. Case water<br />
resistant to IP67, connectors to IP65. Menu driven, with alphanumeric display.<br />
Auto storage of time and date of last calibration for GLP. Memory for 2400<br />
readings of data, time and date, for Notepad results collection, or for AutoLog<br />
with logging intervals between 1s and 90h. Fitted with RS232C interface and<br />
supplied with download-software, charger and solutions. Rechargeable NiMH<br />
battery gives up to 50h operation.<br />
TPS WP-82 Dissolved Oxygen<br />
Meter<br />
TPS,WP-82 (6009)<br />
AU<br />
Portable hand-held dissolved oxygen and<br />
temperature meter. Operating ranges 0<br />
to 20ppm, 0 to 240% saturation, 0 to 45%<br />
gaseous and ppm with salinity correction.<br />
temperature range -10 to 120°C. Case water<br />
resistant to IP67, connectors to IP65, with<br />
3m detachable cable and ED1 electrode.<br />
Menu driven, with alphanumeric display.<br />
Auto storage of time and date of last calibration for GLP. RS232C interface,<br />
and memory for 150 readings of data, time and date, for Notepad results<br />
collection, or for AutoLog results collection with logging intervals between<br />
1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied<br />
with download-software, charger and solutions.<br />
72