MDUs are classified into the following categories:<br />

Classification<br />

Actual Premises <strong>Co</strong>unt<br />

Very Small 2 - 9<br />

Small 10-30<br />

Medium 31-60<br />

Large 61-110<br />

FDA >110<br />

Table 3 MDU Classifications<br />

Fibre allocations for MDUs are based on an assumption that the lower number in the actual<br />

premises count will generally be horizontal or “garden” MDUs (e.g. a set of detached dwellings<br />

grouped around a central driveway) and may also be semi-detached housing. This classification<br />

would also apply to semi-detached MDUs within a community, for example a rest-home or similar.<br />

For this example the same fibre allocation applied to SDU will be applied.<br />

For the range of MDUs from Small to Large, if contained within the same building or in close vicinity,<br />

a ratio of 1.5 fibres per residential dwelling is used. This can be applied as having 1 fibre for initial<br />

connection and the remaining fibres available for use for building services or future non-addressable<br />

locations.<br />

For FDA sized MDUs the fibre allocation is consistent with the 1.5 fibres per residential premise<br />

however the FDH requires connection to the DFN.<br />

For commercial buildings an allocation of the greater of 12 fibres per floor or two fibres per premises<br />

shall be applied and the LF <strong>Network</strong> should be designed so as to be able to provide any diverse<br />

connection requirements.<br />

Classification Actual Premises <strong>Co</strong>unt Fibre Allocations<br />

Very Small 2 – 9 1.5 per premises<br />

Small 10-30 1.5 per premises<br />

Medium 31-60 1.5 per premises<br />

Large 61-110 1.5 per premises<br />

FDA >110 1.5 per premises<br />

<strong>Co</strong>mmercial Per Floor The greater of 12 per floor or 2<br />

fibres per premises<br />

Table 4 MDU Fibre Allocation:<br />

Extra fibres shall be allocated as required for any specific connections (in building services, lift<br />