<strong>Thermoelectric</strong> <strong>Module</strong>s<br />

PRODUCT SELECTION GUIDE


INTRODUCTION<br />

Principles of Operation<br />

A practical thermoelectric module generally consists of two or more elements of n and p-type doped semiconductor<br />

material that are connected electrically in series and thermally in parallel. These thermoelectric elements and their<br />

electrical interconnects typically are mounted between two ceramic substrates. A variety of different shapes, substrate<br />

materials, metallization patterns and mounting options are available.<br />

The schematic diagram above shows a typical thermoelectric module assembly. Both N-type and P-type Bismuth<br />

Telluride thermoelectric materials are used in a thermoelectric cooler. This arrangement causes heat to move<br />

through the module in one direction only while the electrical current moves back and forth alternately between the<br />

top and bottom substrates through each N and P element. N-type material is doped so that it will have an excess of<br />

electrons and P-type material is doped so that it will have a deficiency of electrons. The extra electrons in the N<br />

material and the “holes” resulting from the deficiency of electrons in the P material are the carriers which move the<br />

heat energy through the thermoelectric material. Most thermoelectric cooling modules are fabricated with an equal<br />

number of N-type and P-type elements where one N and P element pair form a thermoelectric “couple.” For example,<br />

the module illustrated above has two pairs of N and P elements and is termed a “two-couple module”.<br />

Cooling capacity (heat actively pumped through the thermoelectric module) is proportional to the magnitude of the<br />

applied DC electric current and the thermal conditions on each side of the module. By varying the input current<br />

from zero to maximum, it is possible to regulate the heat flow and control the surface temperature.<br />

Advantages of <strong>Thermoelectric</strong> <strong>Module</strong>s<br />

■ No moving parts<br />

■ Small and lightweight<br />

■ Maintenance-free<br />

■ Acoustically silent and electrically “quiet”<br />

■ Heating and cooling with the same module (including temperature cycling)<br />

■ Wide operating temperature range<br />

■ Highly precise temperature control (to within 0.1°C)<br />

■ Operation in any orientation, zero gravity and high G- levels<br />

■ Environmentally friendly<br />

■ Sub-ambient cooling<br />

■ Cooling to very low temperatures (-80°C)<br />

2


APPLICATIONS<br />

Electronics Cooling<br />

Electronics package cooling<br />

Integrated circuit coolers<br />

Lasers and Telecommunications<br />

Laser diode coolers<br />

Precision device cooling (lasers, microprocessors etc.)<br />

Automotive<br />

Climate controlled seats<br />

Medical / Biomedical / Pharmaceutical<br />

Thermal cycling devices (e.g. PCR Cyclers and blood analyzers)<br />

Laboratory cold plates<br />

Tissue preparation and storage<br />

Dewpoint hygrometers<br />

Electrophoresis cell coolers<br />

Cold chambers<br />

Constant temperature baths<br />

Semiconductor<br />

Silicon wafer cooling<br />

Wafer thermal characterization<br />

Instrumentation, Sensors and Detectors<br />

Charge Coupled Device (CCD) Cooling<br />

Charge Induced Device (CID) cooling<br />

Infrared detectors<br />

Thermal Management<br />

Compact heat exchangers<br />

Immersion coolers<br />

Space Cooling<br />

Small portable and stationary refrigeration<br />

Wine and beverage coolers<br />

Food coolers<br />

Aerospace / Military / Defense<br />

Infrared seeking missiles<br />

Thermal viewers<br />

Night vision equipment<br />

Thermal weapons sights<br />

Power Generation<br />

Remote power systems<br />

Consumer appliances (insect control)<br />

3


H<br />

TEC TEC NUMBERING SYSTEM SYSTEM<br />

The following symbols are used in the tables:<br />

Imax = Maximum input current in amperes<br />

Qmax = Maximum heat pumping capacity in watts at DT = 0<br />

Vmax = Maximum DC input voltage in volts at Imax and DTmax with Th = 50°C<br />

DTmax = Maximum temperature differential in °C at a zero heat load (Q = 0)<br />

W<br />

H<br />

Type 1 Type 2<br />

L1<br />

Multistage Type 1 — “CASCADE”<br />

W1<br />

6300 / 127 / 060AX<br />

1. 2. 3. 4. 5. 6. 7.<br />

1. <strong>Product</strong> Line<br />

63 = 150°C Maximum temperature<br />

95 = 200°C Maximum temperature<br />

2. Shape<br />

0 = Standard module<br />

1 = Undesignated<br />

2 = 2 stage module<br />

3 = 3 stage module<br />

3. Classification number<br />

0 = Standard module<br />

1 = Small size module<br />

2 = Miniature module<br />

3 = <strong>Module</strong>s configured<br />

for laser diode applications<br />

4 = High current module<br />

4. Number of couples<br />

5. Maximum current<br />

0.1 Ampere increments<br />

L2<br />

L1<br />

W2<br />

H<br />

W<br />

H<br />

W1<br />

L2<br />

4<br />

L1<br />

Multistage Type 2<br />

L2<br />

6. Substrate specification<br />

A. Standard tolerance—plain ceramic surface<br />

(lapped)<br />

■ Miniature module<br />

(+0.15mm height tolerance)<br />

■ Standard module<br />

(+0.25mm height tolerance)<br />

■ 2 stage module<br />

(+0.35mm height tolerance)<br />

B. Tight tolerance – plain ceramic surface (precision<br />

lapped)<br />

■ Miniature module (No specification)<br />

■ Standard module<br />

(+0.025mm height tolerance)<br />

■ 2 stage module<br />

(+0.25mm height tolerance)<br />

H. Solderable metalized ceramic on<br />

hot side external surface<br />

M. Solderable metalized ceramic on<br />

both hot and cold side external surface<br />

7. Options<br />

S = RTV seal<br />

L1<br />

W2<br />

Type 2 thermoelectric modules feature<br />

a “porch” for easy attachment of leads.<br />

This makes the L2 dimension slightly<br />

longer than the L1 dimension. Please<br />

call for exact L2 measurements for the<br />

modules that you are interested in.<br />

MATERIALS AND<br />

SPECIFICATIONS<br />

ARE SUBJECT<br />

TO CHANGE<br />

WITHOUT NOTICE.


<strong>Thermoelectric</strong> <strong>Module</strong> <strong>Product</strong> <strong>Selection</strong> <strong>Guide</strong><br />

Single Stage <strong>Module</strong>s<br />

1.2A Models<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150°C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6300/007/012 9500/007/012 1.2 0.6 0.9 70 1 4.01 4.01 2.33<br />

6300/018/012 9500/018/012 1.2 1.6 2.5 70 2 6.05 6.05 7.62 2.59<br />

6302/031/012 9502/031/012 1.2 2.8 4.3 70 1 7.98 7.98 2.08<br />

6302/065/012<br />

1.8A Models<br />

9502/065/012 1.2 5.8 8.9 70 1 12.10 11.20 2.59<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6300/007/018 9500/007/018 1.8 0.9 0.9 70 1 4.01 4.01 2.03<br />

6300/018/018 9500/018/018 1.8 2.4 2.5 70 2 6.05 6.05 7.62 2.28<br />

6302/023/018 9502/023/018 1.8 3.1 3.2 70 1 6.05 7.98 1.77<br />

6302/029/018 9502/029/018 1.8 3.9 4.0 70 1 6.05 9.91 1.77<br />

6302/031/018 9502/031/018 1.8 4.1 4.3 70 1 7.98 7.98 1.77<br />

6302/065/018<br />

3.0A Models<br />

9502/065/018 1.8 8.7 8.9 70 1 12.10 11.20 2.28<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6301/017/030 9501/017/030 3.0 3.8 2.3 72 1 11.50 11.50 3.18<br />

6301/023/030 9501/023/030 3.0 5.2 3.2 72 1 7.39 22.40 3.18<br />

6301/031/030 9501/031/030 3.0 7.0 4.3 72 1 15.10 15.10 3.18<br />

6301/071/030 9501/071/030 3.0 16.0 9.8 72 1 22.4 22.40 3.18<br />

6301/127/030<br />

4.0A Models<br />

9501/127/030 3.0 29.0 17.5 72 1 29.7 29.70 3.94<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6300/017/040 9500/017/040 4.0 5.1 2.3 72 1 15.01 15.10 4.16<br />

6301/017/040 9501/017/040 4.0 5.1 2.3 72 1 11.50 11.50 3.18<br />

6301/023/040 9501/023/040 4.0 6.9 3.2 72 1 7.39 22.40 3.18<br />

6300/031/040 9500/031/040 4.0 9.3 4.3 72 1 20.00 20.00 4.16<br />

6301/031/040 9501/031/040 4.0 9.3 4.3 72 1 15.10 15.10 3.18<br />

6301/033/040 9501/033/040 4.0 4.8 4.5 72 1 15.90 22.40 3.37<br />

6300/035/040 9500/035/040 4.0 10.0 4.8 72 1 15.10 29.80 4.16<br />

6300/071/040 9500/071/040 4.0 21.0 9.8 72 1 29.80 29.80 4.16<br />

6301/071/040 9501/071/040 4.0 21.0 9.8 72 1 22.40 22.40 3.18<br />

6300/127/040 9500/127/040 4.0 38.0 17.5 72 1 39.70 39.70 4.16<br />

6301/127/040 9501/127/040 4.0 38.0 17.5 72 1 29.70 29.70 3.94<br />

Tabulated specifications are derived from the average performance of actual modules operating<br />

in ambient air at sea level. Temperature differential is the difference in temperature between two copper plates attached<br />

to the hot and cold module face plate using zinc-oxide-loaded silicone grease at the plate-to-module interfaces.<br />

<strong>Product</strong>s available from stock. For other products please call for delivery information.<br />

5


<strong>Thermoelectric</strong> <strong>Module</strong> <strong>Product</strong> <strong>Selection</strong> <strong>Guide</strong><br />

Single Stage <strong>Module</strong>s<br />

6.0A Models<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6300/017/060 9500/017/060 6.0 7.6 2.3 72 1 15.10 15.10 4.16<br />

6300/031/060 9500/031/060 6.0 14.0 4.3 72 1 20.00 20.00 4.16<br />

6300/035/060 9500/035/060 6.0 16.0 4.8 72 1 15.10 29.80 4.16<br />

6300/071/060 9500/071/060 6.0 32.0 9.8 72 1 29.80 29.80 4.16<br />

6300/127/060 9500/127/060 6.0 57.0 17.5 72 1 39.70 39.70 4.16<br />

6301/127/060 9501/127/060 6.0 57.0 17.5 72 1 29.70 29.70 3.61<br />

6300/128/060<br />

8.5A Models<br />

9500/128/060 6.0 57.0 17.6 72 2 39.70 39.70 42.80 4.16<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6300/017/085 9500/017/085 8.5 11.0 2.3 72 1 15.10 15.10 3.94<br />

6300/031/085 9500/031/085 8.5 20.0 4.3 72 1 20.00 20.00 3.94<br />

6300/035/085 9500/035/085 8.5 22.0 4.8 72 1 15.10 29.80 3.94<br />

6300/063/085 9500/063/085 8.5 40.0 8.7 72 1 39.70 39.70 3.94<br />

6300/071/085 9500/071/085 8.5 45.0 9.8 72 1 29.80 29.80 3.94<br />

6300/127/085 9500/127/085 8.5 80.0 17.5 72 1 39.70 39.70 3.94<br />

6300/128/085 9500/128/085 8.5 80.0 17.6 72 2 39.70 39.70 42.8 3.94<br />

9.0A Models<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6300/031/090 9500/031/090 9.0 22.0 4.3 72 1 29.80 29.80 4.65<br />

10.0A Models<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6301/063/100 9501/063/100 10.0 47.0 8.7 72 1 20.10 39.70 3.64<br />

6301/127/100 9500/127/100 10.0 95.0 17.5 72 1 39.70 39.70 3.64<br />

12.0A Models<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6304/071/120 9504/071/120 12.0 63.0 9.8 72 1 40.10 40.10 4.65<br />

15.0A Models<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6300/031/150 9500/031/150 15.0 35.0 4.3 72 1 29.80 29.80 4.60<br />

6304/071/150 9504/071/150 15.0 79.0 9.8 72 1 40.10 40.10 4.65<br />

24.0A Models<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6304/031/240 9504/031/240 24.0 55.0 4.3 72 1 39.70 39.70 4.62<br />

6


<strong>Thermoelectric</strong> <strong>Module</strong> <strong>Product</strong> <strong>Selection</strong> <strong>Guide</strong><br />

High Power <strong>Module</strong>s<br />

TE MODULE NUMBER Imax Qmax Vmax DTmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C)s W L1 L2 H<br />

6305/071/240 9505/071/240 24.0 127.0 9.8 72 1 59.00 59.00 3.90<br />

6300/090/300 9500/090/300 30.0 202.0 12.4 72 2 46.00 83.00 87.50 4.62<br />

630X/127/150 950X/127/150 15.0 142.0 17.5 72 1 40.00 40.00 3.45<br />

630X/131/150 950X/131/150 15.0 147.0 18.0 72 1 30.00 60.00 3.45<br />

6300/180/085 9500/180/085 8.5 114.0 24.8 72 2 38.50 60.00 65.00 3.94<br />

6300/241/060 9500/241/060 6.0 108.0 33.1 72 1 55.00 55.00 4.16<br />

Miniature <strong>Module</strong>s for Laser Diode and Optoelectronics Applications<br />

TE MODULE NUMBER Imax Qmax Vmax Dtmax Type DIMENSIONS (mm)<br />

200° C (A) (W) (V) (°C)s W L1 L2 H<br />

9503/018/012M 1.2 1.6 2.5 70 2 6.05 6.20 7.19 1.64<br />

9503/018/018M 1.8 2.4 2.5 70 2 6.05 6.20 7.19 1.64<br />

9503/023/018M 1.8 3.1 3.2 70 1 6.05 8.18 1.64<br />

9503/029/018M 1.8 3.9 4.0 70 1 6.05 10.20 1.64<br />

9503/031/018M 1.8 4.1 4.3 70 1 7.98 7.98 1.64<br />

9503/035/018M 1.8 4.7 4.8 70 1 6.05 12.20 1.64<br />

9503/018/020M 2.0 2.6 2.5 70 2 6.05 6.20 7.19 1.64<br />

9503/035/025M 2.5 6.5 4.8 70 1 6.05 12.20 1.64<br />

<strong>Module</strong>s with Center Holes<br />

TE MODULE NUMBER Imax Qmax Vmax Dtmax Type DIMENSIONS (mm)<br />

200° C (A) (W) (V) (°C)s W L H Hole Dia.<br />

9506/023/030B 3.0 5.2 3.2 72 1 15.10 15.10 3.18 6.7<br />

9506/023/040B 4.0 6.9 3.2 72 1 15.10 15.10 3.18 5.0<br />

9504/023/040B 4.0 6.9 3.2 72 1 18.0 18.0 3.18 8.0<br />

9500/125/060B<br />

Long Life <strong>Module</strong>s<br />

6.0 56.0 17.2 72 1 39.70 39.70 3.80 4.7<br />

TE MODULE NUMBER Imax Qmax Vmax Dtmax Type DIMENSIONS (mm)<br />

150° C (A) (W) (V) (°C)s W L1 L2 H<br />

7001/127/040B 4.0 34.0 17.5 72 1 39.70 39.70 3.94<br />

7000/127/060B 6.0 51.0 17.5 72 1 39.70 39.70 4.16<br />

7000/127/085B 8.5 72.0 17.5 72 1 39.70 39.70 3.94<br />

7000/031/150B 15.0 31.0 4.3 72 1 29.80 29.80 4.60<br />

7004/071/150B 15.0 71.0 9.8 72 1 40.10 40.10 4.65<br />

2 Stage <strong>Module</strong>s (Mulitstage)<br />

TE MODULE NUMBER Imax Qmax Vma Dtmax Type DIMENSIONS (mm)<br />

150° C 200° C (A) (W) (V) (°C) W1 L1 W2 L2 H<br />

6320/157/035 9520/157/035 3.5 11.0 18.2 106 1 20.00 20.00 39.6 39.60 7.39<br />

6320/185/065 9520/185/065 6.5 37.0 17.9 95 1 29.80 29.80 39.7 39.70 6.99<br />

6320/157/070 9520/157/070 7.0 24.0 17.3 106 1 20.00 20.00 39.7 39.70 6.99<br />

6320/094/230 9520/094/230 24.0 74.0 8.2 88 2 45.20 54.10 45.2 45.10 7.49<br />

6320/118/080 9520/118/080 8.0 21.0 12.8 106 1 15.00 20.00 30.00 40.00 6.40<br />

6320/197/080 9520/197/080 8.0 52.0 17.8 91 1 29.80 29.80 39.70 39.70 6.45<br />

3 Stage <strong>Module</strong>s (Mulitstage)<br />

TE MODULE NUMBER Imax Qmax Vma Dtmax Type DIMENSIONS (mm)<br />

200° C (A) (W) (V) (°C) W1 L1 W2 L2 W3 L3 H<br />

6330/119/045M 4.5 9.7 8.6 111.0 1 15.20 15.20 20.00 20.00 29.80 29.80 9.20<br />

6330/228/045M 4.5 18.0 16.4 111.0 1 20.00 20.00 29.80 29.80 39.70 39.70 9.82<br />

7


YOUR LOCAL DISTRIBUTOR<br />

© All material copyright of <strong>Ferrotec</strong> Corporation<br />

Version: 092001<br />

SALES LOCATIONS<br />

USA______________________________<br />

<strong>Ferrotec</strong> (USA) Corporation<br />

40 Simon Street<br />

Nashua<br />

NH-03060-3075<br />

USA<br />

Tel: (603) 883 9800<br />

Fax: (603) 883 2308<br />

http://www.ferrotec.com<br />

info@ferrotec.com<br />

GERMANY (EUROPEAN HEADQUARTERS) ____<br />

<strong>Ferrotec</strong> GmbH<br />

Hohes Gestade 14<br />

72622 Nürtingen<br />

Germany<br />

Tel: +49 7022 9270 0<br />

Fax: +49 7022 9270 10<br />

http://www.ferrotec.com<br />

gmbh@ferrotec.com<br />

UNITED KINGDOM AND IRELAND __________<br />

<strong>Ferrotec</strong> (UK) Ltd.<br />

Talisman Business Centre<br />

Bicester<br />

Oxon. OX26 6HR<br />

United Kingdom<br />

Tel: +44 1869 363200<br />

Fax: +44 1869 363201<br />

http://www.ferrotec.com<br />

info@ferrotec.co.uk<br />

CORPORATE HEADQUARTERS<br />

<strong>Ferrotec</strong> Corporation<br />

1-4-14 Kyobashi<br />

Chuo-ku<br />

Tokyo 104-0031<br />

Japan<br />

http://www.ferrotec.co.jp

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!