CONCERTINA FOIL BATTS TM - SUB-FLOOR<br />
QUICK AND EASY TO INSTALL<br />
EASY TO RETROFIT<br />
Total R-value of the structure (R T ) is the sum of all component R-values, including the internal airspaces and the surface air films<br />
on either side of the structure. NB: Framing timbers are excluded from the Total R-value (R T ), as per AS/NZS 4859.1:2002.<br />
SUB - FLOOR - <strong>SmartFrame</strong> JOISTS<br />
ENCLOSED BUILDING PERIMETER<br />
SFREBP-1<br />
SUB - FLOOR - SmartJOIST<br />
ENCLOSED BUILDING PERIMETER<br />
SFREBP-2<br />
Brick veneer walls and/or close weave shade cloth behind base boards.<br />
Brick veneer walls and/or close weave shade cloth behind base boards.<br />
Perforated CONCERTINA FOIL BATT<br />
for floors - Over-lapped and stapled<br />
MIN 90 mm<br />
depth <strong>SmartFrame</strong><br />
LVL floor joists<br />
Perforated CONCERTINA FOIL BATT<br />
for floors - Over-lapped and stapled<br />
<strong>SmartFrame</strong><br />
SJ200 & SJ240<br />
I-Joists<br />
Non ventilated<br />
air-space MIN 90 mm<br />
Non ventilated<br />
air-space 90 mm<br />
Non -<br />
ventilated<br />
air-space<br />
(still air)<br />
soil<br />
<strong>SmartFrame</strong> LVL bearer<br />
Stumps<br />
WINTER R T<br />
R T 3.0*<br />
SUMMER<br />
R T 1.5<br />
Non ventilated<br />
air-space<br />
(still air)<br />
soil<br />
Stumps<br />
WINTER<br />
R T 3.0*<br />
SUMMER<br />
R T 1.5<br />
Adapted from Wren Industries Pty Ltd.- TF1 from WREN DD-1<br />
To view WREN DD-1 see www.concertinafoilbatts.com<br />
LINK Thermal Performance<br />
Adapted from Wren Industries Pty Ltd.- TF1 from WREN DD-1<br />
To view WREN DD-1 see www.concertinafoilbatts.com<br />
LINK Thermal Performance<br />
SUSPENDED FLOOR - RED ALERT JOISTS<br />
OPEN BUILDING PERIMETER WITH<br />
CLOSED JOIST CAVITIES<br />
SFROBP-1<br />
SUSPENDED FLOOR - SmartJoist<br />
- OPEN BUILDING PERIMETER<br />
WITH CLOSED JOIST CAVITIES<br />
SFROBP-2<br />
Perforated CONCERTINA FOIL BATT<br />
for floors - Over-lapped and stapled<br />
Non ventilated 50 mm<br />
Non ventilated 50 mm<br />
Ventilated sub-floor air-space<br />
Continuous lining material to create a<br />
still air joist cavity (with small gaps or<br />
perforation holes for drainage and breathing)<br />
Examples - standard RFL roll foil - foil<br />
side down or fibre cement sheet<br />
Minimum of 100 mm<br />
depth <strong>SmartFrame</strong><br />
LVL floor joists<br />
WINTER<br />
R T 2.8*<br />
SUMMER<br />
R T 1.2<br />
Perforated CONCERTINA FOIL BATT<br />
for floors - Over-lapped and stapled<br />
Non ventilated<br />
air-space 100 mm<br />
Non ventilated<br />
air-space<br />
Ventilated sub-floor air-space<br />
Continuous lining material to create a<br />
still air joist cavity (with small gaps or<br />
perforation holes for drainage and breathing)<br />
Examples - standard RFL roll foil - foil<br />
side down or fibre cement sheet<br />
<strong>SmartFrame</strong><br />
SJ200 & SJ240<br />
I-Joists<br />
WINTER<br />
R T 2.8 *<br />
SUMMER<br />
R T 1.2<br />
Adapted from Wren Industries Pty Ltd.- TF2 from WREN DD-1<br />
To view WREN DD-1 see www.concertinafoilbatts.com<br />
LINK Thermal Performance<br />
Adapted from Wren Industries Pty Ltd.- TF2 from WREN DD-1<br />
To view WREN DD-1 see www.concertinafoilbatts.com<br />
LINK Thermal Performance<br />
* R T value is dependent upon depth of non-ventilated airspace. For R T values for alternative joist depths, contact Wren Industries Pty Ltd<br />
Perforated CONCERTINA FOIL<br />
BATTS TM allow moisture<br />
drainage and maximum<br />
breathing of timber flooring,<br />
and combined with still<br />
airspaces, produce high and<br />
consistent thermal<br />
performance, reflecting 97%<br />
of radiant heat back to the<br />
floor.<br />
FOIL BATTS do not absorb<br />
or retain heat and therefore<br />
do not create warm cosy<br />
nesting environments for<br />
rodents or pests.<br />
“BREATHING” AIRSPACES<br />
ALLOWS GLUEING OF SHEETING<br />
<strong>SmartFrame</strong> Sub-floor <strong>Design</strong> <strong>Guide</strong> 6