Railway-EMC-Standards prEN 50121-X - EMC Test NRW GmbH
Railway-EMC-Standards prEN 50121-X - EMC Test NRW GmbH
Railway-EMC-Standards prEN 50121-X - EMC Test NRW GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Changes in <strong>prEN</strong> <strong>50121</strong>-4<br />
<strong>EMC</strong><br />
TEST <strong>NRW</strong><br />
EN <strong>50121</strong>-4 : 2000<br />
<strong>prEN</strong> <strong>50121</strong>-4 : 2006<br />
Comment<br />
Radiated emission according<br />
to EN 50081-2<br />
Radiated emission according to<br />
EN 61000-6-4<br />
No change in<br />
requirements !<br />
Conducted emission<br />
according to EN 50081-2 and<br />
EN 61000-3-x<br />
Conducted emission according to<br />
EN 61000-6-4 and EN 61000-3-x<br />
No change in<br />
requirements !<br />
www.emc-test.de<br />
Radiated immunity according<br />
to EN 61000-4-3<br />
80-1000 MHz with 10V/m ;<br />
and ENV 50204<br />
900±5 MHz with 10 V/m<br />
Magnetic fields test according<br />
to EN 61000-4-8 with 50Hz,<br />
100 A/m<br />
Radiated immunity according to<br />
EN 61000-4-3<br />
80-1000 MHz with 10V/m<br />
800-1000 MHz with 20 V/m<br />
1400-2100 MHz with 10 V/m<br />
2100-2500 MHz with 5 V/m<br />
Magnetic fields test according to<br />
EN 61000-4-8 with 0/16,7/50Hz,<br />
100 A/m AC-system and 300 A/m<br />
DC-system<br />
Change of test procedure<br />
for 900 MHz and<br />
expansion of frequency<br />
range up to<br />
2,5 GHz !<br />
Additional test with higher<br />
expenditure of time !<br />
EN 61000-4-9 with 300 A/m<br />
EN 61000-4-9 with 300 A/m<br />
6<br />
Conducted immunity<br />
according to EN 61000-4-2/-4/-<br />
5/-6<br />
Conducted immunity according to<br />
EN 61000-4-2/-4/-5/-6/-12<br />
No change in<br />
requirements !<br />
15.09.2006 Uwe Rörden Revision <strong>prEN</strong> <strong>50121</strong>-X : 2006