RAK.E<br />

AIR COOLED WATER CHILLER<br />

R407C Ecological gas<br />

Solutions<br />

B Base<br />

I Integrata<br />

Versions<br />

ST Standard<br />

LN Low noise<br />

Equipment<br />

AS standard equipment<br />

DS Desuperheater<br />

HR Total heat recovery<br />

BT Fluid low temperature (down to -8°C)<br />

LT Fluid low temperature (down to -25°C) with R404A<br />

Main features<br />

Housing<br />

Base made of painted galvanised steel; panels made of galvanised<br />

steel externally coated with plastic (PVC) film and mounted on aluminium<br />

profiles to ensure total weathering resistance. Panels are<br />

internally lined to reduce the noise level (LN Accessories only).<br />

Compressor<br />

Reciprocating SEMIHERMETIC type, fixed on vibration isolation<br />

mountings (2S); <strong>com</strong>plete with oil pump, crankcase electrical heater,<br />

electronic protection, intercepting valves on discharge ; flexible<br />

joints on suction and discharge (2S); in tandem configuration (4s).<br />

Fan<br />

Low speed, axial-flow fans fitted with accident-prevention protective<br />

grille; directly coupled motor with built-in thermal cutout and IP<br />

54 protection degree; aerodynamic housing and wing profile blades<br />

increase efficiency and decrease noise level.<br />

Air heat exchanger<br />

Finned coil made with copper pipes and aluminium fins offering a<br />

high exchange surface area.<br />

Water heat exchanger<br />

Shell and tube type, thermally insulated by vapour-proof closed cell.<br />

Electrical board<br />

Switchboard to standards IEC 204-1/EN60204-1, <strong>com</strong>plete with contactor<br />

and protection for <strong>com</strong>pressor and fans. Main isolator and<br />

door interlock safety device.<br />

Control<br />

The microprocessor controls the unit capacity by timing the <strong>com</strong>pressors<br />

and checks the operating alarms with the possibility to<br />

connect to BMS.<br />

Refrigerant circuit<br />

Filter dryer, moisture-liquid sight glass, solenoid valve, intercepting<br />

valve on the liquid line, thermostatic expansion valve with external<br />

equaliser, HP and LP pressure switches.<br />

Water circuit<br />

(Integrata): Automatic charging cock with gauge, safety valve,<br />

expansion tank, water pump, water tank.<br />

Accessories<br />

Spring vibration isolation.<br />

Modulating fan speed condensing control<br />

ON/OFF Fan condensing control (5°C)<br />

Part-winding soft start.<br />

Additional capacity step on <strong>com</strong>pressor/s (only 2S)<br />

Compressor suction intercepting valve.<br />

Remote control panel<br />

Max and min voltage relay.<br />

Evaporator electrical heater<br />

Upgrading electronic control<br />

Clock board.<br />

MODBUS interface electronic board<br />

LONWORKS interface electronic board<br />

Refrigerant gas HP and LP pressure gauges<br />

Total heat recovery - 100% (HR equipments)<br />

Electromechanical flow switch<br />

Pumping group, 1 pump.<br />

Additional stand-by water pump<br />

Automatic water filling valve (closed circuit)<br />

External water fittings<br />

Air flow separate <strong>com</strong>pressor room(standard)<br />

Coil protection grille.<br />

26<br />