Chillers Catalogue - Ctarefrigeracion.com
Chillers Catalogue - Ctarefrigeracion.com
Chillers Catalogue - Ctarefrigeracion.com
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
RAK.W - RAK.W/PC<br />
WATER COOLED WATER CHILLER AND WATER TO WATER HEAT PUMP<br />
R407C Ecological gas<br />
Solutions<br />
B Base<br />
Versions<br />
ST Standard<br />
LN Low noise<br />
Equipment<br />
AS standard equipment<br />
DS Desuperheater<br />
HR Total heat recovery<br />
BT Fluid low temperature (down to -8°C)<br />
LT Fluid low temperature (down to -25°C) with R404A<br />
Main features<br />
Housing<br />
Frame made of painted galvanised steel heavy profiles to ensure<br />
total mechanical and corrosion resistance.<br />
Compressor<br />
Reciprocating SEMIHERMETIC type in tandem configuration, <strong>com</strong>plete<br />
with oil pump, crankcase electrical heater, thermal protection,<br />
intercepting valves on discharge.<br />
Water heat exchanger<br />
Shell and tube type, shell made of thick steel ; exchanger thermally<br />
insulated by vapour-proof closed cell (evaporator for cooling only<br />
unit; evaporator and condenser for heat pump unit).<br />
Electrical board<br />
Switchboard to standards IEC 204-1/EN60204-1, <strong>com</strong>plete with<br />
contactor and protection for <strong>com</strong>pressor. Main isolator and door<br />
interlock safety device.<br />
Control<br />
The microprocessor controls the unit capacity by timing the <strong>com</strong>pressors<br />
and checks the operating alarms with the possibility to connect<br />
to BMS.<br />
Refrigerant circuit<br />
Filter dryer, moisture-liquid sight glass, solenoid valve, intercepting<br />
valve on the liquid line, thermostatic expansion valve with external<br />
equaliser, HP and LP pressure switches.<br />
Heat pump<br />
Unit suitable for manual hydraulic circuit reverse cycle<br />
Accessories<br />
Spring vibration isolation.<br />
Part-winding soft start.<br />
Compressor suction intercepting valve.<br />
Remote control panel<br />
Max and min voltage relay.<br />
Evaporator electrical heater<br />
Upgrading electronic control<br />
Clock board.<br />
MODBUS interface electronic board<br />
LONWORKS interface electronic board<br />
Refrigerant gas HP and LP pressure gauges<br />
Total heat recovery - 100% (HR equipments)<br />
Electromechanical flow switch<br />
70<br />
www.euroklimat.it