Chillers Catalogue - Ctarefrigeracion.com
Chillers Catalogue - Ctarefrigeracion.com
Chillers Catalogue - Ctarefrigeracion.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
RAK.C<br />
AIR COOLED WATER CHILLER<br />
R407C Ecological gas<br />
Solutions<br />
B Base<br />
Versions<br />
ST Standard<br />
LN Low noise<br />
Equipment<br />
AS standard equipment<br />
DS Desuperheater<br />
HR Total heat recovery<br />
BT Fluid low temperature (down to -8°C)<br />
LT Fluid low temperature (down to -25°C) with R404A<br />
Main features<br />
Housing<br />
Base made of painted galvanised steel; panels made of galvanised<br />
steel externally coated with plastic (PVC) film and mounted on aluminium<br />
profiles to ensure total weathering resistance. Panels are<br />
internally lined to reduce the noise level (LN Accessories only).<br />
Compressor<br />
Reciprocating SEMIHERMETIC type, fixed on vibration isolation<br />
mountings; <strong>com</strong>plete with oil pump, crankcase electrical heater,<br />
electronic protection, intercepting valves on suction and discharge<br />
(mod. 015-20 HP); flexible joints on suction and discharge.<br />
Fan<br />
Centrifugal type with two suctions, coupled to the three phases<br />
motor by V-belt and pulley. The fans have forward curved blades in<br />
order to get the best performances in terms of efficiency and noise<br />
level.<br />
Air heat exchanger<br />
Finned coil made with copper pipes and aluminium fins offering a<br />
high exchange surface area.<br />
Water heat exchanger<br />
Shell and tube type, thermally insulated by vapour-proof closed cell.<br />
Electrical board<br />
Switchboard to standards IEC 204-1/EN60204-1, <strong>com</strong>plete with contactor<br />
and protection for <strong>com</strong>pressor and fans. Main isolator and<br />
door interlock safety device.<br />
Control<br />
The microprocessor controls the unit capacity by timing the <strong>com</strong>pressors<br />
and checks the operating alarms with the possibility to<br />
connect to BMS.<br />
Refrigerant circuit<br />
Filter dryer, moisture-liquid sight glass, solenoid valve, intercepting<br />
valve on the liquid line, thermostatic expansion valve with external<br />
equaliser, HP and LP pressure switches.<br />
Accessories<br />
Spring vibration isolation.<br />
Vibration isolation mountings.<br />
Low ambient device by motorised dampers<br />
Part-winding soft start.<br />
Additional capacity step on <strong>com</strong>pressor/s<br />
Compressor suction intercepting valve.<br />
Remote control panel<br />
Max and min voltage relay.<br />
Evaporator electrical heater<br />
Refrigerant gas HP and LP pressure gauges<br />
Total heat recovery - 100% (HR equipments)<br />
Electromechanical flow switch<br />
Pumping group, 1 pump.<br />
Automatic water filling valve (closed circuit)<br />
Air flow separate <strong>com</strong>pressor room<br />
Coil protection grille.<br />
44<br />
www.euroklimat.it