Central Inverters from SMA:<br />

High Technology for Solar Power Stations<br />

Larger, more powerful, more efficient<br />

– the success of photovoltaics has led<br />

to constantly growing solar power<br />

plant sizes in recent years. With the<br />

<strong>Sunny</strong> Central product line, SMA<br />

offers central inverters intended specifically<br />

for high-performance class<br />

installations. Thanks to their particular<br />

features, such as high efficiency, string<br />

monitoring, team capability, medium<br />

voltage feed, and the possibility of<br />

outdoor installation, <strong>Sunny</strong> Centrals<br />

are optimally suited for deployment<br />

in solar power plants with a homogeneous<br />

structure.<br />

An Investment That Pays Off<br />

From the 100 kW <strong>Sunny</strong> Central up<br />

to the first 1 megawatt solar inverter<br />

in series production, SMA <strong>Sunny</strong><br />

Centrals achieve the best efficiency<br />

in this performance bracket, and are<br />

therefore particularly economical.<br />

With the <strong>Sunny</strong> Central 100, it was<br />

even possible to improve efficiency to<br />

97.6 percent by utilizing innovative<br />

transformer technologies. Many of<br />

the SMA central inverters can operate<br />

without a low-voltage transformer. The<br />

advantage: higher efficiency through<br />

direct feed into the medium-voltage<br />

grid.<br />

Central inverters with their own weatherproof<br />

housings permit installation<br />

outdoors immediately adjacent to the<br />

generator. As a result, long transmission<br />

distances and construction measures<br />

are eliminated.<br />

Proven Reliability and<br />

Long Service Life<br />

<strong>Sunny</strong> Centrals are designed for a<br />

lifespan of at least 20 years, because<br />

maximum investment security is only<br />

ensured when inverters operate reliably<br />

and faultlessly over a long period<br />

of time. SMA system monitoring provides<br />

additional operational security:<br />

through comprehensive communication<br />

interfaces with which operators<br />

can monitor their <strong>Sunny</strong> Centrals from<br />

any PC, via the Internet, anywhere in<br />

the world. Possible output fluctuations<br />

can thus be recognized and corrected<br />

early.<br />

Comprehensive Service<br />

Around the World<br />

SMA not only has long years of experience<br />

in the implementation of<br />

large solar power plants, but can<br />

also offer the appropriate provision<br />

of service for every application. The<br />

customer has a choice among various<br />

service concepts: from service and<br />

maintenance as needed, up to an “allaround,<br />

worry-free package” with a<br />

service, maintenance, and technical<br />

availability warranty; facility operators<br />

are in good hands with SMA.<br />

Product Overview <strong>Sunny</strong> Central<br />

<strong>Sunny</strong> Central 400MV<br />

<strong>Sunny</strong> Central 500MV<br />

<strong>Sunny</strong> Central 700MV<br />

<strong>Sunny</strong> Central 1000MV / 1120MV<br />

<strong>Sunny</strong> Central 100HE<br />

<strong>Sunny</strong> Central 200HE<br />

<strong>Sunny</strong> Central 250HE<br />

<strong>Sunny</strong> Central 350HE<br />

<strong>Sunny</strong> Central 500HE / 560HE<br />

<strong>Sunny</strong> Central 100i <strong>Sunny</strong> Central 150i <strong>Sunny</strong> Central 200i <strong>Sunny</strong> Central 250i<br />

<strong>Sunny</strong> Central 350i<br />

<strong>Sunny</strong> Central 100o<br />

<strong>Sunny</strong> Central 100LV / 125LV<br />

49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!