Intelligent Spindles<br />

Accessories<br />

Power Table<br />

Overview of possible numbers of channels<br />

The maximum number of DGD Intelligent Spindles<br />

per mPro400GC <strong>Control</strong>ler depends on load. When<br />

caculating the maximum number of spindles, please<br />

consider the following conditions:<br />

■ Maximum speed at 20% of maximum torque (at<br />

1BTSE, 2BTSE, 3BTSE and 4BTSE)<br />

■ Final tightening stage up to 500 Nm Maximal Speed<br />

50 rpm at maximum torque (at 1BTSE, 2BTSE, 3BTSE<br />

and 4BTSE-4B500A...)<br />

■ Final tightening stage over 500 Nm Maximal Speed 20<br />

rpm at maximum torque (at 4BTSE-4B660A..., 4BTSE-<br />

4B660A-4VK4MS, 4BTSE-4B360A-4Z1250A and<br />

4BTSE-4B460A-4Z1600A)<br />

If higher settings are chosen, number of channels should be<br />

reduced.<br />

If different spindle types are used at the controller, the number of<br />

channels will be individually defined.<br />

Please contact <strong>Apex</strong> <strong>Tool</strong> <strong>Group</strong>.<br />

<strong>Control</strong> Type<br />

Maximum number of DGD Intelligent Spindles<br />

1BTSE… 2BTSE… 3BTSE… 4BTSE…<br />

Number of<br />

cables to<br />

fastening<br />

control<br />

Comments<br />

CPM3 16 6 6 6 1 OC=Outside <strong>Control</strong>ler<br />

CPM3 16 6 6 6 1 H=With Archnet<br />

CPM6 32 12 12 12 2 Archnet Hub Included<br />

CPM9 ... 18 18 18 3 Archnet Hub Included<br />

<strong>Control</strong> Panel ... 32 32 32 ... Archnet Hub Included<br />

Power Distribution System<br />

The Power Distribution System is used in conjunction<br />

with the Intelligent Spindles. This system is used for<br />

power distrbution. Includes standard hardware such as<br />

E stop circuitry, 24VDC power supply, line filter, CPM,<br />

necessary relays, disconnect and viewing window.<br />

External power transformer is required.<br />

Power Distribution<br />

System<br />

CPM3<br />

CPM6<br />

CPM9<br />

Part No.<br />

PDB-CPS3<br />

PDB-CPS6<br />

PDB-CPS9<br />

CPM3 With Internal Power<br />

Transformer and Without<br />

Viewing Window<br />

Contact your local Application Center<br />

for more information.<br />

CPS6 / CPS9 With<br />

mPro400-SG and<br />

Internal Power Transformer<br />

Contact your local Application Center<br />

for more information.<br />

Power <strong>Control</strong> Package<br />

Each Power <strong>Control</strong> Package consists of the following:<br />

• mPro400 GC-M Global <strong>Control</strong>ler<br />

• PDB-CPS X power distribution box<br />

with viewing window<br />

• Power transformer<br />

• Aluminum stand<br />

Part Number<br />

MPRO400GCMPDBCPS3A<br />

MPRO400GCMPDBCPS3T<br />

MPRO400GCMPDBCPS6A<br />

MPRO400GCMPDBCPS6T<br />

MPRO400GCMPDBCPS9A<br />

MPRO400GCMPDBCPS9T<br />

T=PLC Siemens S7 for additional I/O<br />

Torque <strong>Transducer</strong> Verification Fixture<br />

(TTVF)<br />

Fast, accurate, cost effectiv e way to verify your torque<br />

transducer on the assembly line measure. Included is<br />

a joint simulator, slip ring torque transducer and spindle<br />

adapter. The joint simulator can be mounted to a tooling<br />

plate or mounted to the spindle directly. Any data<br />

recorder with the proper interface can be used.<br />

Torque Range<br />

(Nm)<br />

Part No.<br />

2-23 579900PT-23<br />

6-68 579900PT-68<br />

20-200 579900PT-200<br />

50-500 579900PT-500<br />

100-1000 579900PT-1000<br />

89