Meet <strong>Element</strong> 2.0<br />

Upon it’s introduction to the market a little over three years ago; the <strong>Element</strong>, <strong>Visionaire</strong> <strong>Lighting</strong>’s flagship LED fixture,<br />

simply took off.Now, after hundreds of <strong>Element</strong> projects have been installed around the globe, we’re taking our bestselling<br />

LED luminaire and making it even better.<br />

What’s New?<br />

The <strong>Element</strong> <strong>II</strong>’s quality is visually apparent as soon as it is table‐topped alongside a competitor’s fixture.<br />

Enhanced areas include:<br />

• Aluminum end caps, which are die cast for strength; and enhanced with design elements for a pleasingly<br />

sophisticated look.<br />

• Additional, advanced optics that leap ahead of the competition; giving the <strong>Element</strong> <strong>II</strong> the leading edge in nearly every<br />

desired application.<br />

• More housing sizes for increased scale-ability.<br />

• Two new low-profile end mount arms designed to enhance the beauty of the <strong>Element</strong> <strong>II</strong> while adding function for<br />

higher lumen lighting applications.<br />

<strong>Visionaire</strong> <strong>Lighting</strong>’s Evolution C<br />

Technology Is All About Performance<br />

The <strong>Element</strong> <strong>II</strong> incorporates the flexible Vision bar<br />

technology which allows for LED fixture selection<br />

from 24 LEDs all the way to 288 LEDs in 24 LED<br />

increments<br />

We at <strong>Visionaire</strong> <strong>Lighting</strong> have pioneered the highest<br />

benchmark for Solid State <strong>Lighting</strong> (SSL) technology<br />

in the industry.<br />

We call this benchmark Evolution C; and we have<br />

officially incorporated it into this release of our newest,<br />

<strong>Element</strong> <strong>II</strong> family of LED luminaires.<br />

Evo/C is the kind of comprehensive approach that only<br />

a lighting manufacturer with a decade-plus of production can advance.<br />

Evo/C is more than just the lumen output of LEDs -- it’s more than the driver -- and it’s more than the housing.<br />

Evo/C is synergy. It’s picking the best of everything; and constructing parts in-house when what is available isn’t<br />

good enough.<br />

Evo/C is hiring the smartest engineers in the business to design, build, test; then re-test until a fixture meets <strong>Visionaire</strong>’s<br />

exacting standards.<br />

Evo/C is about vertical integration within our own plant - Made in the USA.<br />

2.


PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF<br />

VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.<br />

NEXT ASSY<br />

APPLICATION<br />

USED ON<br />

DIMENSIONS ARE IN INCHES<br />

TOLERANCES:<br />

FRACTIONAL<br />

ANGULAR: MACH 1 BEND 1<br />

TWO PLACE DECIMAL .03<br />

THREE PLACE DECIMAL .015<br />

INTERPRET GEOMETRIC<br />

TOLERANCING PER:<br />

MATERIAL<br />

FINISH<br />

DO NOT SCALE DRAWING<br />

DRAWN<br />

CHECKED<br />

ENG APPR.<br />

MFG APPR.<br />

Q.A.<br />

COMMENTS:<br />

NAME<br />

DATE<br />

19645 RANCHO WAY , RANCHO DOMINGUEZ, CA 90220<br />

8 7 6<br />

PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF<br />

VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.<br />

D<br />

PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF<br />

VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.<br />

More Tailored Mounting Options For Maximum Versatility<br />

Bolt-on arm<br />

D<br />

8 7 6 5 4 3 2 1<br />

C<br />

Mast arm<br />

Wall mount<br />

8 7 5<br />

6 4 3 2 1<br />

D<br />

8 7 6<br />

PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF<br />

VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.<br />

Pendant mount<br />

D<br />

D<br />

B<br />

D<br />

Bolt-on arm Quick Mount<br />

C<br />

C<br />

Mast Arm Fitter End Mount<br />

A<br />

C<br />

C<br />

C<br />

A<br />

B<br />

End Mount (Side)<br />

End Mount (Front)<br />

B<br />

Ceiling mount<br />

B<br />

B<br />

8<br />

7<br />

6<br />

B<br />

A<br />

UNLESS OTHERWISE SPECIFIED:<br />

JRTAPIA 5/26/11<br />

TITLE:<br />

VISIONAIRE LIGHTING<br />

XX<br />

A<br />

A<br />

8<br />

7<br />

6<br />

5<br />

4<br />

--<br />

PER ORDER --<br />

3<br />

SIZE<br />

DWG. NO.<br />

REV<br />

UNLESS OTHERWISE SPECIFIED:<br />

ELEMENT B <strong>II</strong>- ROUND MAF<br />

SCALE: DIMENSIONS NTS WEIGHT:<br />

ARE IN INCHES SHEET 1<br />

DRAWN<br />

OF 1<br />

TOLERANCES:<br />

2<br />

FRACTIONAL ±<br />

1<br />

CHECKED<br />

ANGULAR: ± 1 °<br />

ENG APPR.<br />

TWO PLACE DECIMAL ± .03<br />

THREE PLACE DECIMAL ± .015 MFG APPR.<br />

NAME<br />

DATE<br />

TITLE:<br />

VISIONAIRE LIGHTING<br />

19645 RANCHO WAY , RANCHO DOMINGUEZ, CA 90220<br />

A<br />

INTERPRET GEOMETRIC<br />

TOLERANCING PER:<br />

MATERIAL<br />

FINISH<br />

DO NOT SCALE DRAWING<br />

A<br />

Q.A.<br />

COMMENTS:<br />

SIZE<br />

B<br />

DWG. NO. REV<br />

EL2-MA<br />

SCALE: 1:4 WEIGHT:<br />

SHEET 1 OF 1<br />

Q1<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

8<br />

7<br />

3.<br />

6


TESTED FOR LIFE<br />

The secret to the <strong>Element</strong> <strong>II</strong>’s advanced efficiency is<br />

superior heat reduction.<br />

To get there, we built a powerhouse of a heat sink, and<br />

designed it to make maximum use of the Venturi Effect.<br />

Sinking the Heat – Successfully<br />

In LED luminaires, the most critical areas to cool are the<br />

junction points where the LEDs meet the circuit board.<br />

The heat sink is used to draw heat away from these<br />

points.<br />

The <strong>Element</strong> <strong>II</strong>’s extruded aluminum heat sink is<br />

substantial.<br />

With a maximized fin ratio and precisely-mapped<br />

channel distributions; thermal build-up peels away<br />

from the <strong>Element</strong> <strong>II</strong>’s junction points, allowing for cooler<br />

operation.<br />

Feel the Breeze – the Venturi Effect<br />

The Venturi Effect dictates that, with increased air flow,<br />

heat transfer rates increase exponentially, removing heat<br />

at ever-faster rates.<br />

Hold your hand over the <strong>Element</strong> <strong>II</strong>, and feel it — that<br />

rush of air rising up through the fixture, and out the top.<br />

Engineering for this effect cools LEDs, drivers and<br />

internal components; allowing the <strong>Element</strong> <strong>II</strong> to:<br />

• Withstand higher ambient temperatures.<br />

• Withstand higher drive currents.<br />

• Achieve a low thermal resistance rating.<br />

• Extend LED life.<br />

This effect doesn’t occur with external, decorative heat<br />

sinks -- like those found in competing products.<br />

Combining heat sink technology with the Venturi Effect<br />

produces a superior, long-lasting product with increased<br />

light output.<br />

6.


<strong>Element</strong> <strong>II</strong>, Size 1<br />

Drive current of 350mA yields an L 70 of 150,000 hours.<br />

Drive current of 530mA yields an L 70 of 100,000 hours.<br />

<strong>Element</strong> <strong>II</strong>, Size 2<br />

Drive current of 350mA yields an L 70 of 150,000 hours.<br />

Drive current of 530mA yields an L 70 of 100,000 hours.<br />

<strong>Element</strong> <strong>II</strong>, Size 3<br />

Drive current of 350mA yields an L 70 of 150,000 hours.<br />

Drive current of 530mA yields an L 70 of 100,000 hours.<br />

<strong>Element</strong> <strong>II</strong>, Size 4<br />

Drive current of 350mA yields an L 70 of 150,000 hours.<br />

Drive current of 530mA yields an L 70 of 100,000 hours.<br />

<strong>Element</strong> <strong>II</strong>, Size 5<br />

Drive current of 350mA yields an L 70 of 150,000 hours.<br />

7.


Evolution C<br />

Pioneering the Benchmark for Ultimate<br />

LED Performance<br />

<strong>Visionaire</strong> <strong>Lighting</strong>’s Evolution C benchmark of luminaires<br />

features the highest-lumen-output Light Emitting Diodes<br />

on the market, outfitted with our proprietary, cutting edge<br />

optics (patents pending).<br />

Here’s why:<br />

1. Highest available lumens per watt for maximum<br />

efficiency.<br />

2. Improved CRI (Color Rendering Index) for truer colors.<br />

3. Tighter color binning for maximum Kelvin uniformity.<br />

4. Lower forward voltages means lower system watts for<br />

increased efficiency (Lumens/Watt).<br />

5. Longer life for 350 and 530 mA.<br />

6. Marginal decreases in efficiency between 350 and<br />

530 mA.<br />

The <strong>Element</strong> <strong>II</strong>’s VisionBar TM LED light assemblies come in<br />

multiples of 24 (minimum 24 to maximum 288 LEDs), and<br />

are field replaceable.<br />

No other outdoor lighting manufacturer can offer your project<br />

more efficient, cost-effective and application-specific LED<br />

lighting solutions.<br />

Superior Kelvin and CRI<br />

The <strong>Element</strong> <strong>II</strong> is offered in two highly desirable<br />

Kelvin temperatures, 4000K and 5500K. We<br />

have selected these two Kelvin temperatures as<br />

standard because 4000K matches the Kelvin of<br />

typical metal halide fixtures and 5500K yields a<br />

bluer white color which enhances car dealerships<br />

and lower wattage applications. Both Kelvins<br />

have similar lumen output. The CRI of the 4000K<br />

LEDs are 70 and the CRI of the 5500K LEDs are<br />

75. Please consult factory for additional Kelvin<br />

temperatures which can be ordered as well as<br />

LEDs with higher CRIs.<br />

The Color Rendering Index, or CRI, is a measure of<br />

the quality of color light as the human eye sees it.<br />

Driver Power<br />

The <strong>Element</strong> <strong>II</strong> is powered by a choice of 350 or 530<br />

mA high‐performance Constant Current Philips<br />

Advance Xitanium LED drivers, which accept<br />

120v thru 277v, 50 Hz to 60 Hz, input. Power<br />

factor of 90%. Rated for -40 oC operations.<br />

Expected life of the driver ranges from 100,000 to<br />

150,000 hours.<br />

1) The LED driver reduces output power to LEDs<br />

if its maximum allowable case temperature is<br />

exceeded.<br />

2) The LED driver complies with UL standard<br />

UL1012.<br />

3) The LED driver has a Class A sound rating.<br />

4) The LED drivers comes dimming enabled with<br />

a 0-10 volt input.<br />

5) The LED driver has a THD (Total Harmonic<br />

Distortion) of less than 20%.<br />

8.


Why Dim LEDs?<br />

Dimming LEDs saves energy at an approximate 1:1 ratio.<br />

This means by dimming the LEDs to 50% of their light<br />

output, the LEDs’ energy usage will decrease by nearly<br />

50%. Dimming LEDs also makes them run cooler, which<br />

extends the life of the driver, as well as doubling or tripling<br />

the LEDs lumen maintenance. Select the dimming type,<br />

then schedule settings and, in the case of Dual Circuit,<br />

add optional motion sensor. LED luminaires really earn<br />

their worth when controls are applied. Consider choosing<br />

one of the following options to achieve the ultimate return<br />

on your investment.<br />

1. Analog 0 – 10 Volt<br />

A pre-installed 0 - 10 volt driver enables the fixture to be<br />

operated by a separately-provided control system.<br />

2. Dual Circuit (DC)<br />

Separate driver circuits provide two levels of light<br />

(high and low) without requiring a controller. Can be tied to<br />

an optional motion sensor.<br />

3. Event-Based Dimming (EB)<br />

Luminaires arrive installed with controls that are preprogrammed<br />

to trigger up to five, timed events of varying<br />

dimming percentages.<br />

See the Event-Based Dimming Example Chart below.<br />

4. Wireless Controls (WC)<br />

Enables event-based dimming to be modified remotely<br />

after pre-programmed fixtures are installed.<br />

• Triggers up to 32 events.<br />

• Provides outage notifications.<br />

• Monitors energy consumption.<br />

Optional Motion Sensor<br />

Activity close to the luminaire triggers an event of 100%<br />

brightness lasting for several minutes. Afterwards,<br />

illumination returns to the level of the current event.<br />

Examples:<br />

• Two drivers → a 50% reduction in output.<br />

• Three drivers → a 33% or 67% reduction in output.<br />

9.


10.


Performance Starts with Optics that Outpace All Others<br />

<strong>Visionaire</strong> <strong>Lighting</strong>’s proprietary optics are the industry leader. Patent pending lens designs produced in-house simply<br />

can’t be duplicated by others. Painstakingly developed by our Photometrics team, these nine optic types give the<br />

<strong>Element</strong> <strong>II</strong> an edge; allowing us to manufacture fixtures that illuminate beautifully at lower wattages and wider pole<br />

spacings. To learn more, visit our Photometrics website section; or call us for layout assistance.<br />

A Superior Line-up of Optics<br />

pe I<br />

1<br />

e <strong>II</strong><br />

2e <strong>II</strong><br />

2<br />

-R<br />

-R<br />

e <strong>II</strong>I<br />

3e <strong>II</strong>I<br />

3<br />

-R<br />

-R<br />

Type V<br />

Type IV<br />

Type <strong>II</strong>I Type <strong>II</strong> Type I<br />

Optics Isolux Type Pattern I Best Application(s) Type <strong>II</strong> Type <strong>II</strong>I Key Feature(s) Type IV Type V<br />

1<br />

2<br />

3<br />

4<br />

5<br />

• One- and two-lane roadways. Enables pole spreads at six to eight times mounting height<br />

Type I<br />

Type <strong>II</strong> • Long Type pedestrian <strong>II</strong>I paths. Type IV to achieve Type intersection. V<br />

Type 1 I<br />

Type 2 <strong>II</strong> • Warehouse Type 3 <strong>II</strong>Iaisles.<br />

Type 4 IV Type 5 V<br />

1<br />

2<br />

3<br />

4<br />

5<br />

• Parking 2-R lots.<br />

3-R Best where sideways 4-A light is required 5W at light levels greater<br />

<strong>II</strong><br />

• Street-adjacent back lots. than one Footcandle.<br />

2-R<br />

3-R<br />

4-A<br />

5W<br />

2-R • Two-, three- 3-R and four-lane 4-A Optimal for staggered 5W light spacing requirements.<br />

roadways.<br />

4+CLS<br />

Type <strong>II</strong> Type <strong>II</strong>I Type IV Type V<br />

<strong>II</strong>-R<br />

2<br />

3<br />

4<br />

5<br />

Type <strong>II</strong>I Type IV • Four- Type to six-lane V roadways. 4+CLS Designed for side light, 45 o light, and forward<br />

• Cross walks.<br />

4+CLS<br />

Type 3<br />

light applications requiring light levels of one or<br />

<strong>II</strong>I<br />

Type 4<br />

<strong>II</strong>I<br />

IV<br />

Type 5<br />

V<br />

3<br />

• Site perimeters.<br />

more Footcandles.<br />

4<br />

5<br />

2-R<br />

3-R<br />

4-A<br />

• Shopping centers.<br />

5W<br />

Effective for forward-light applications that require a half a<br />

• Office complexes.<br />

Footcandle or more across distances.<br />

3-R IV<br />

4-A<br />

5W<br />

3-R<br />

4-A<br />

5W<br />

• Auto dealerships.<br />

Best where a combination of high Footcandles at low<br />

4+CLS<br />

• High-brightness inspection wattages are required.<br />

IV-A<br />

areas.<br />

Type IV<br />

Type 4<br />

IV+CLS<br />

4<br />

V<br />

4-A<br />

4-A<br />

V-W<br />

4+CLS<br />

4+CLS<br />

4+CLS<br />

Type 4+CLS<br />

V<br />

Type 5 V<br />

5<br />

5W<br />

5W<br />

• LEEDs projects.<br />

• High-clearance parking<br />

structures.<br />

• Low-clearance parking<br />

structures.<br />

• Outdoor parking areas.<br />

Useful for projects requiring pristine back light control and<br />

zero light trespass.<br />

Excellent for low mounting-height installations requiring<br />

minimums of one Footcandle.<br />

Best for 400+ wattage requirements, and retrofitting<br />

vertical lamp fixtures at typical 120x120 or<br />

180 x180 spacings.<br />

A = Automotive . R = Roadway . W = Wide . +CLS = with external Cutoff Louver Shield option.<br />

For additional LEEDS-qualifying shields, please consult factory.<br />

11.


Our new Type Five optic designed for large parking lots enables 400 watt fixtures to be replaced at a<br />

lower wattage without photopic light level sacrifice with improved uniformity.<br />

Twin <strong>Element</strong> <strong>II</strong> Fixtures - End Mount<br />

EL2-4-T5W-168LC-530-4000K<br />

275 system watts<br />

Type Five Wide distribution<br />

120 foot by 120 foot spacing<br />

33 foot mounting height<br />

Full cutoff<br />

12.


Our new Type Four optic with Cutoff Louver System is designed for the most stringent light trespass<br />

criteria, cutting the light behind the luminaire to .01 foot candles at 3/4 mounting height.<br />

Single <strong>Element</strong> <strong>II</strong> Fixture - Bolt-On Arm<br />

EL2-3-T4-120LC-530-4000K-CLS<br />

190 system watts<br />

Type Four distribution with Cutoff Louver System<br />

60 foot spacing<br />

25 foot mounting height<br />

Full cutoff<br />

13.


(LIFE) Let us Find the Perfect<br />

Balance for Your Specific<br />

Application<br />

The L70 test determines the point in an LED’s life<br />

when it reaches 70 percent of its initial output.<br />

<strong>Element</strong> <strong>II</strong> series LEDs have been determined to<br />

last 150,000+ hours in 40 o C environments when<br />

driven at 350 mA.<br />

At <strong>Visionaire</strong> <strong>Lighting</strong>, we have discovered that<br />

the secret to the perfect LED fixture fit is to<br />

determine the perfect balance between number of<br />

VisionBars TM and the milliamps to drive them at.<br />

More Lumens per Dollar<br />

In an exceptionally well-cooled fixture like the<br />

<strong>Element</strong> <strong>II</strong>, it becomes possible to drive fewer LEDs<br />

at higher milliamps. Fewer LEDs putting out more<br />

lumens creates the right amount of light for the job,<br />

while at the same time reducing the initial cost of<br />

the luminaire.<br />

14.


HID to LED Crossovers<br />

Return on Investment (ROI) per single fixture retrofit. A Brilliant Performer FINANCIALLY, TOO!<br />

Existing<br />

Wattage<br />

System<br />

Watts<br />

HPS<br />

Life Hours<br />

Proposed<br />

<strong>Element</strong> <strong>II</strong><br />

Configuration<br />

Street <strong>Lighting</strong> Crossovers<br />

System<br />

Watts<br />

LED L70<br />

Life Hours<br />

Watts<br />

Saved<br />

Energy<br />

Saved<br />

10 Year<br />

Energy<br />

Savings*<br />

10 Year<br />

Maintenance<br />

Payback**<br />

10 Year<br />

Total<br />

Savings**<br />

400 HPS 464 24,000 EL2-3-120LC-530 190 100,000 274 59% $1,434 $332 $1,766<br />

250 HPS 295 24,000 EL2-1-96LC-530 152 100,000 143 48% $750 $332 $1,082<br />

200 HPS 250 24,000 EL2-1-72LC-530 114 100,000 136 54% $710 $332 $1,042<br />

150 HPS 188 24,000 EL2-1-72LC-530 114 100,000 74 39% $380 $332 $712<br />

100 HPS 130 24,000 EL2-1-48LC-530 76 100,000 54 41% $270 $332 $602<br />

70 HPS 91 24,000 EL2-1-48LC-350 56 150,000 35 38% $170 $332 $502<br />

*Savings calculated on 12 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour.<br />

**Estimated cost of replacing 1 HPS lamp every 6 years, including equipment rental, parts and labor.<br />

Existing<br />

Wattage<br />

System<br />

Watts<br />

MH<br />

Life Hours<br />

Proposed<br />

<strong>Element</strong> <strong>II</strong><br />

Configuration<br />

Parking Lot <strong>Lighting</strong> Crossovers<br />

System<br />

Watts<br />

LED L70<br />

Life Hours<br />

Watts<br />

Saved<br />

Energy<br />

Saved<br />

10 Year<br />

Energy<br />

Savings*<br />

10 Year<br />

Maintenance<br />

Payback**<br />

10 Year<br />

Total<br />

Savings**<br />

400 MH 458 20,000 EL2-3-144LC-530 228 100,000 230 50% $1,500 $398 $1,898<br />

250 MH 295 20,000 EL2-1-96LC-530 152 100,000 143 48% $935 $398 $1,333<br />

175 MH 210 15,000 EL2-1-72LC-530 114 100,000 96 45% $630 $398 $1,028<br />

100 MH 129 20,000 EL2-1-48LC-530 76 100,000 53 41% $350 $398 $748<br />

70 MH 90 12,000 EL2-1-48LC-350 56 150,000 34 37% $220 $398 $618<br />

*Savings based on 12 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour.<br />

**Estimated cost of replacing 1 MH lamp every 5 years, including equipment rental, parts and labor.<br />

Existing<br />

Wattage<br />

System<br />

Watts<br />

MH<br />

Life Hours<br />

Parking Garage <strong>Lighting</strong> Crossovers<br />

Proposed<br />

<strong>Element</strong> <strong>II</strong><br />

Configuration<br />

System<br />

Watts<br />

LED L70<br />

Life Hours<br />

Watts<br />

Saved<br />

Energy<br />

Saved<br />

10 Year<br />

Energy<br />

Savings*<br />

10 Year<br />

Maintenance<br />

Payback**<br />

10 Year<br />

Total<br />

Savings**<br />

175 MH 210 15,000 EL2-1-48LC-530 76 100,000 134 64% $1,769 $500 $2,269<br />

175 MH 210 15,000 EL2-1-72LC-350 84 150,000 126 60% $1,663 $500 $2,163<br />

150 MH 188 15,000 EL2-1-48LC-530 76 100,000 112 60% $1,478 $500 $1,978<br />

150 MH 188 15,000 EL2-1-72LC-350 84 150,000 104 55% $1,373 $500 $1,873<br />

100 MH 129 20,000 EL2-1-48LC-350 56 150,000 73 57% $964 $500 $1,464<br />

70 MH 90 12,000 EL2-1-24LC-530 38 100,000 52 58% $686 $500 $1,186<br />

*Savings based on 24 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour.<br />

**Estimated cost of replacing 1 MH lamp every 2.5 years, including parts and labor.<br />

15.


D<br />

C<br />

B<br />

A<br />

8 7 6 5<br />

4 3 2 1<br />

PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF<br />

VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.<br />

8<br />

7<br />

6<br />

5<br />

NEXT ASSY<br />

APPLICATION<br />

4<br />

USED ON<br />

UNLESS OTHERWISE SPECIFIED:<br />

NAME DATE<br />

VISIONAIRE LIGHTING<br />

19645 RANCHO WAY , RANCHO DOMINGUEZ, CA 90220<br />

DIMENSIONS ARE IN INCHES DRAWN JRTAPIA 5/26/11<br />

TOLERANCES:<br />

FRACTIONAL<br />

CHECKED<br />

TITLE:<br />

ANGULAR: MACH 1 BEND 1<br />

ENG APPR.<br />

A<br />

TWO PLACE DECIMAL .03<br />

THREE PLACE DECIMAL .015 MFG APPR.<br />

INTERPRET GEOMETRIC<br />

Q.A.<br />

TOLERANCING PER:<br />

COMMENTS:<br />

MATERIAL<br />

--<br />

SIZE DWG. NO.<br />

REV<br />

FINISH<br />

PER ORDER --<br />

DO NOT SCALE DRAWING<br />

SCALE: NTS WEIGHT: SHEET 1 OF 1<br />

3<br />

2<br />

1<br />

D<br />

C<br />

B<br />

<strong>Area</strong><br />

A<br />

Front View<br />

A<br />

E<br />

Side View - EBOA<br />

C<br />

Fixture A B C D E Max. LEDs Lbs<br />

EL2-S 14” 14½” 4” 21½” n/a 72 30<br />

EL2-1 18” 14½” 4” 21½” 38” 96 34<br />

EL2-2 24” 14½” 4” 21½” 42” 144 38<br />

EL2-3<br />

EL2-4<br />

EL2-5<br />

28”<br />

32”<br />

38”<br />

14½”<br />

14½”<br />

14½”<br />

4”<br />

4”<br />

4”<br />

21½” 28½”<br />

21½” 32½”<br />

21½” 48½”<br />

144<br />

192<br />

288<br />

41<br />

62<br />

68<br />

B<br />

B<br />

D<br />

Side View<br />

BOLT-ON ARM<br />

Garage/Canopy<br />

A<br />

Top View<br />

A<br />

E<br />

Side View - EMAF<br />

C<br />

B<br />

Side View/End Cap<br />

XX<br />

ELEMENT B <strong>II</strong>- ROUND MAF<br />

Type I<br />

ype <strong>II</strong><br />

ype <strong>II</strong>I<br />

Model Optics Source Milliamps Kelvin Voltage Mounting Finish Options<br />

EL2-S<br />

Type <strong>II</strong><br />

Type <strong>II</strong> Type <strong>II</strong>I Type<br />

4000K<br />

IV<br />

120-277<br />

Type V<br />

# of LEDs mA<br />

Bolt-On Arm White<br />

(T1)<br />

1<br />

2<br />

3<br />

4*Neutral<br />

*Universal 5<br />

(BOA)<br />

(WH)<br />

24 (24LC) 350 530 white voltage<br />

48 (48LC) 350 530 (4K) (UNV) Wall Mount<br />

Type I<br />

Type <strong>II</strong><br />

<strong>II</strong><br />

Type <strong>II</strong>I<br />

Type IV<br />

Type V<br />

*Includes Cast Wall Plate<br />

1<br />

2 72 (72LC) 2-R<br />

3 350 3-R<br />

4 n/a 4-A 5500K<br />

5 480 5W<br />

(T2)<br />

(WM)<br />

(3) (5)<br />

*Cool (5)<br />

white<br />

Knuckle Mount<br />

Bronze<br />

EL2-1<br />

24 (24LC) 350 530 (55K) 347 (KM)<br />

(BZ)<br />

Type <strong>II</strong>-R<br />

2-R<br />

48 (48LC)<br />

3-R<br />

350 4-A<br />

530<br />

(8)<br />

(T2R)<br />

4+CLS<br />

5W<br />

Mast Arm Fitter<br />

72 (72LC) 350 530<br />

(MAF)<br />

Type <strong>II</strong><br />

Type <strong>II</strong>I<br />

<strong>II</strong>I 96 Type (96LC) IV Type 350 V 530<br />

(3) (5)<br />

Ceiling Mount Black<br />

2<br />

3<br />

4<br />

4+CLS 5<br />

(T3)<br />

(CM)<br />

(BK)<br />

EL2-2<br />

120 (120LC) 350<br />

144 350<br />

Pendant Mount<br />

Type <strong>II</strong>I<br />

Type IV<br />

Type (144LC) V<br />

*Specify pendant Iength<br />

2-R 3<br />

3-R 4<br />

4-A 5<br />

(T4)<br />

(3)<br />

5W<br />

(PM)<br />

EL2-3<br />

120 (120LC) 530<br />

Grey<br />

End Mount (GY)<br />

Type IV-A 144 (144LC) 530<br />

Bolt-On<br />

3-R<br />

4-A<br />

4+CLS 5W<br />

(T4A)<br />

(5)<br />

(EBOA)<br />

EL2-4<br />

168 (168LC) 350 530<br />

End Mount<br />

Type IV<br />

Type V<br />

*Requires 2-3/8”<br />

Silver Metallic<br />

4<br />

4+CLS<br />

(T5)<br />

5 192 (192LC) 350 530<br />

horizontal tenon<br />

(3) (5)<br />

(EMAF)<br />

(SL)<br />

*End mount only<br />

EL2-5<br />

*End 4-A mount only<br />

4+CLS<br />

Type V-W<br />

(T5W)<br />

216 (216LC)<br />

240 (240LC)<br />

264 (264LC)<br />

288 (288LC)<br />

350<br />

350<br />

350<br />

350<br />

(3)<br />

Custom Color<br />

(CC)<br />

Photocell & Receptacle<br />

*Specify voltage<br />

(PCR120) (PCR208)<br />

(PCR240) (PCR277)<br />

Photo Receptacle (PER)<br />

*With shorting cap<br />

Button Type Photocell<br />

*Specify voltage<br />

(PC120) (PC208)<br />

(PC240) (PC277)<br />

Round Pole Plate Adaptor<br />

For 4ӯ Pole (RPP4)<br />

For 5ӯ Pole (RPP5)<br />

<strong>Element</strong> Conduit Box<br />

(ECB)<br />

Cutoff Louver System<br />

(CLS)<br />

Vandal Resistant Shield<br />

(VRS)<br />

Dual Circuit<br />

(DC)<br />

Motion Sensor<br />

(MS)<br />

Dimming/Controls<br />

*Consult factory<br />

16.


Housing<br />

• The fixture housing is heavy-duty, extruded aluminum, with<br />

heat radiating fins. A perforated aluminum top cover, beneath<br />

a protective debris guard, protects the heat radiating fins<br />

from contaminants and directs constant air flow over them for<br />

maximum cooling.<br />

Thermal Management<br />

• The <strong>Element</strong> <strong>II</strong> provides excellent overall thermal management<br />

by maximizing the fixture’s heat sink efficiency. This enables the<br />

<strong>Element</strong> <strong>II</strong> to withstand higher ambient temperatures and drive<br />

currents without degrading LED life. The <strong>Element</strong> <strong>II</strong> has a low<br />

thermal resistance rating. The heat radiating fins and perforated<br />

fixture components create superior thermal management results.<br />

• The L70 test determines the point in an LEDs life when it reaches<br />

70 percent of its initial output. <strong>Element</strong> <strong>II</strong> series LEDs have been<br />

determined to last 150,000+ hours in 40 o C environments when<br />

driven at 350 mA. See LED Data Chart for additional test results.<br />

Optical System<br />

• The highest lumen output LEDs available are utilized in the<br />

<strong>Element</strong> <strong>II</strong> series. IES Types <strong>II</strong>I and V distributions are standard.<br />

The LED VisionBar TM light assemblies come in multiples of 24<br />

(minimum 24 to maximum 288 LEDs) and are field replaceable.<br />

The optical system qualifies as IES full cutoff; and is Dark-Sky<br />

certified to restrict light trespass, glare and light pollution.<br />

Quali-Guard ® Finish<br />

• A Quali-Guard ® thermoset polyester powder coat painted finish<br />

is available in white and custom colors.<br />

Mounting - <strong>Area</strong><br />

•BOA- The cast aluminum Bolt-on Arm is shipped mounted to<br />

the fixture. A pole plate is supplied for mounting to the pole; which<br />

allows for quick and easy fixture installation with two set screws.<br />

•WM- Galvanized steel wall mount bracket can be secured<br />

directly to recessed junction box or the wall. The fixture is supplied<br />

with a shortened arm bracket to keep the fixture closer to the wall.<br />

•CM- Steel ceiling mount bracket can be secured directly to<br />

recessed junction box, or to the ceiling. The housing hanger<br />

bracket allows fixture to be suspended from ceiling bracket while<br />

making wiring connection. The housing bracket then attaches<br />

to the ceiling bracket via a tool-less latch. A tamper-proof screw<br />

can then secure the bracket.<br />

•KM- Knuckle Mount will mount over a 2⅜” horizontal or vertical<br />

tenon and is field adjustable in increments of 5°<br />

•MAF- Mast arm fitter is provided with a cast aluminum arm<br />

adaptor designed to slip fit over a 1¼” to 2” horizontal tenon<br />

(mast arm) and is adjustable +/- 5 degrees for fixture leveling.<br />

EPA Data<br />

Fixture<br />

with Arm<br />

EL2-S<br />

EL2-1<br />

.6<br />

.7<br />

.8<br />

.9<br />

1.3<br />

1.3<br />

1.1<br />

1.2<br />

1.1<br />

1.2<br />

1.1<br />

1.2<br />

An internal clamping device provides a secure attachment to the<br />

mast arm, eliminating the need to drill for thru-bolt attachment.<br />

•EBOA- End Mount version utilizing the same Quick Mount pole<br />

adaptor for a bolt-on application<br />

•EMAF- End Mount Mast Arm Fitter is provided with a cast<br />

aluminum arm adaptor designed to slip fit over a 2” horizontal<br />

tenon (mast arm) and is fully adjustable.<br />

A round pole plate adaptor is required for mounting to a 3”- 6”<br />

round pole.<br />

Mounting - Roadway<br />

• The <strong>Element</strong> <strong>II</strong> - Roadway is provided with a cast aluminum<br />

arm adaptor designed to slip fit over a 1¼” to 2⅜” horizontal tenon<br />

(mast arm) and is adjustable +/- 5 degrees for fixture leveling.<br />

An internal clamping device provides a secure attachment to the<br />

mast arm, eliminating the need to drill for thru-bolt attachment.<br />

Mounting - Garage/Canopy<br />

• Steel ceiling mount bracket can be secured directly to recessed<br />

junction box, or to the ceiling. The housing hanger bracket allows<br />

fixture to be suspended from ceiling bracket while making wiring<br />

connection. The housing bracket then attaches to the ceiling<br />

bracket via a tool-less latch. A tamper-proof screw can then<br />

secure the bracket.<br />

Electrical Assembly<br />

• The <strong>Element</strong> <strong>II</strong> is supplied with a choice of 350 or 530 mA<br />

high‐performance LED drivers that accept 120 v thru 277 v,<br />

50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40 o C<br />

operations.<br />

Solar Vision Pole TM Option<br />

• The <strong>Element</strong> <strong>II</strong> LED is compatible for use with <strong>Visionaire</strong> <strong>Lighting</strong>’s<br />

Solar Vision Pole TM . Power up to 100 watts (SMR-2 rigid panel)<br />

off‐the‐grid in any locale.<br />

Warranty<br />

• Five (5) year Limited Warranty on entire system, including finish.<br />

For full warranty information, visit <strong>Visionaire</strong><strong>Lighting</strong>.com.<br />

Options<br />

• Photocell & receptacle • Cutoff louver system<br />

• Photo receptacle<br />

• Vandal-resistant shield<br />

• Button type photocell • Dual circuit<br />

• Round pole plate adaptor • Motion sensor<br />

• <strong>Element</strong> conduit box<br />

• Dimming/Controls<br />

Please consult factory for custom options and available<br />

upgrades<br />

Listings<br />

• <strong>Element</strong> <strong>II</strong> is listed, suitable for wet locations.<br />

• LM79 and LM80.<br />

• IP65 Listed.<br />

• Dark‐Sky Friendly ® , full cutoff certified by the International<br />

Dark‐Sky Association.<br />

• Meets ANSI C136.31-2001 Vibration Standards at 2G when<br />

ordered with the MAF mounting option.<br />

• DLC Listed.<br />

• RoHS compliant.<br />

• Powder Coated Tough TM .<br />

EL2-2<br />

.8<br />

1.0<br />

1.3<br />

1.4<br />

1.4<br />

1.4<br />

EL2-3<br />

EL2-4<br />

End Mount Only<br />

EL2-5<br />

End Mount Only<br />

.9<br />

1.2<br />

1.3<br />

1.5<br />

1.5<br />

1.5<br />

1.2<br />

1.3<br />

1.6<br />

1.7<br />

2.4<br />

2.3<br />

2.6<br />

2.7<br />

2.6<br />

2.6<br />

2.7<br />

2.7<br />

17.


LED Data Chart<br />

# Bars # LEDs<br />

1<br />

EL2-1<br />

24<br />

Output<br />

mA<br />

Initial<br />

Lumens<br />

Type 1<br />

LED Data Chart for 5500K*<br />

Initial<br />

Lumens<br />

Type 2<br />

Initial<br />

Lumens<br />

Type 2R<br />

Initial<br />

Lumens<br />

Type 3<br />

Initial<br />

Lumens<br />

Type 4<br />

Initial<br />

Lumens<br />

Type 4A<br />

Initial<br />

Lumens<br />

Type 5<br />

Initial<br />

Lumens<br />

Type 5W<br />

System<br />

Watts<br />

120-277<br />

L 70<br />

Hours<br />

@ 40° C<br />

350 2263 2362 2226 2250 2262 2352 2375 2380 28 150,000<br />

530 2520 2841 2470 2776 2684 2691 3030 3047 38 100,000<br />

2<br />

EL2-1<br />

3<br />

EL2-1<br />

4<br />

EL2-1<br />

48<br />

72<br />

96<br />

350 4526 4724 4452 4501 4525 4704 4750 4760 56 150,000<br />

530 5042 5683 4940 5553 5368 5382 6087 6094 76 100,000<br />

350 6789 7086 6678 6483 6786 7056 7125 7140 84 150,000<br />

530 7563 8524 7410 8330 8052 8073 9128 9141 114 100,000<br />

350 9052 9448 8904 8645 9048 9408 9500 9520 112 150,000<br />

530 9923 11365 9880 11107 10736 10764 12174 12188 152 100,000<br />

5<br />

EL2-2<br />

120 350 11315 11810 11130 10212 11310 11760 11875 11900 140 150,000<br />

5<br />

EL2-3<br />

120 530 12405 14207 12350 13884 13440 13457 15216 15235 190 100,000<br />

6<br />

EL2-2<br />

144 350 13588 14172 13356 12255 13572 14112 14250 14280 168 150,000<br />

6<br />

EL2-3<br />

144 530 14885 17048 14820 15260 16128 16146 18260 18816 228 100,000<br />

7<br />

EL2-4<br />

8<br />

EL2-4<br />

168<br />

192<br />

350 15841 16534 15582 14297 15834 16464 16625 16640 196 150,000<br />

530 17367 19890 17290 17803 18788 18837 19418 21818 266 100,000<br />

350 18105 18896 17808 16341 18096 18816 19000 19040 224 150,000<br />

530 19847 22780 19760 20000 21472 21528 22191 24366 304 100,000<br />

9<br />

EL2-5<br />

216 350 20367 21258 20034 20560 20358 20168 21004 21420 252 150,000<br />

10<br />

EL2-5<br />

240 350 22630 23620 22260 22600 22620 23520 23008 23800 280 150,000<br />

11<br />

EL2-5<br />

264 350 24893 25982 24486 24640 24882 25872 25012 26180 308 150,000<br />

12<br />

EL2-5<br />

288 350 27176 28344 26712 26680 27144 28224 27016 28560 336 150,000<br />

Visit www.<strong>Visionaire</strong><strong>Lighting</strong>.com for up-to-the-minute chart information, including types not listed here.<br />

* For 4000K multiply values by 0.97<br />

03.07.12<br />

18.


A Product That’s Road Tested<br />

LED <strong>Lighting</strong> Facts Approved<br />

The LED <strong>Lighting</strong> Facts® is a program of the U.S. Department of Energy that<br />

showcases LED products for general illumination from manufacturers who commit to<br />

testing products and reporting performance results according to industry standards.<br />

For lighting buyers, designers, and energy efficiency programs, the LED <strong>Lighting</strong> Facts<br />

label provides information essential to evaluating products and identifying the best<br />

options.<br />

DesignLights Consortium TM Qualified<br />

The DesignLights Consortium’s mission is to help builders, architects, designers and<br />

commercial property owners implement improved design practices in all areas of the<br />

commercial lighting market. The DLC independently tests and rates fixtures. Approved<br />

fixtures may then qualify for funding from energy companies nationwide. Think of them<br />

as the EnergyStar of outdoor lighting. More at: www.designlights.org<br />

Dark-Sky Certified<br />

The <strong>Element</strong> <strong>II</strong>’s optical system qualifies as IES full cutoff; and is Dark-Sky certified to<br />

restrict light trespass, glare and light pollution. More at www.darksky.org<br />

ETL Certified<br />

The ETL Listed Mark is proof of product compliance to North American safety<br />

standards. Authorities Having Jurisdiction (AHJ’s) in 50 states and Canada and<br />

retailers accept the ETL Listed Mark as proof of product safety. Safety standard test<br />

practices conform to UL, ANSI, CSA, ASTM, NFPA, and NOM.<br />

IP65 Rated<br />

As defined in international standard IEC 60529, IP Code classifies and rates the<br />

degrees of protection provided against the intrusion of solid objects, dust, accidental<br />

contact, and water in mechanical casings and with electrical enclosures.<br />

RoHS Certified<br />

The RoHS directive aims to restrict certain dangerous substances commonly used in<br />

electronic equipment. Any RoHS compliant component must have 100ppm or less of<br />

mercury.<br />

ANSI Certified<br />

The <strong>Element</strong> <strong>II</strong> is ANSI C136.31-2001 certified for luminaire vibration at 2G.<br />